Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-49 Add IP Interface Assembly 6 Connect the Modem NOTE: These instruc tions are for c onnec ting the U.S. Rob otic s modem sup p lied to U.S. c ustomers only. If using a d ifferent mod em, follow the manufac turer’s instruc tions on c onnec ting the mod em. 1. Connec t the RS232 p ort of the mod em to the MODEM c onnec tor of the TN802B external c ab le assembly. NOTE: Chec k the lab els near the c onnec tors; the MODEM and COM2 c onnec tors look the same. 2. Connec t an analog telephone line to the left most analog -line p ort on the mod em as shown in Figure 6-21 . 3. Make sure that the mod em’s DIP switc hes are set as shown in Figure 6-21 and Table 6-5. 4. Plug the mod em into an AC p ower outlet. 5. Turn on the mod em using the switc h on the front of the mod em. Figure 6-21. External Modem Connections for U.S. Robotics Modem Figure Notes 1. Connec t analog line here. 2. DIP switc h 5 must b e up .3. Connec t MODEM c onnec tor here. 4. Connec t p ower c onnec tor here. 12345678 modfrobo KLC 030499 234 1
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-50 Add IP Interface Assembly 6 Connect the Ethernet 1. Connec t the network c ab le to the ETHERNET c onnec tor on the TN802B external c ab le assemb ly. NOTE: You need a CAT5 or better c ab le for 100-Mb yte operation. Install the Circuit Packs !CAUTION: When add ing or rep lac ing any hard ware, b e sure to g round yourself against elec trostatic d isc harg e (ESD) b y wearing a g round ed wrist strap . NOTE: The TN799B and TN802B c irc uit p ac ks are hot-swap p ab le, so you d o not need to p ower d own the c arrier to install them. If you need to remove the TN802B IP Interfac e from the c arrier at a later time, shut down Wind ows NT first b y p ressing the rec essed reset button on the fac ep late (see Figure 6-22 ) of the TN802B IP Interfac e until the LCD shows a flashing MSHUT * . When the flashing stop s and the asterisk d isap p ears (ab out 2 min), it is safe to remove the c irc uit p ac k. Table 6-5. U.S. Robotics Modem Dip Switch Settings Dip Switch Setting Description 1UP DOWNData Terminal Read y normal Data Terminal Read y overrid e 2UP DOWNVe r b a l r e s u lt c o d e s Numeric result c od es 3UP DOWNSuppress result codes Disp lay result cod es 4UP DOWNEc ho offline c ommand s No ec ho, offline c ommand s 5UP DOWNAuto answer on first ring or higher if specified in NVRAM Auto answer off 6UP DOWNCarrier d etec t normal Carrier d etec t overrid e 7UP DOWNLoad NVRAM d efaults Load fac tory d efaults 8UP DOWNDumb mod e Sm a rt m o d e
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-51 Add IP Interface Assembly 6 Figure 6-22. TN802B IP Interface faceplate NOTE: If rep lac ing the existing TN799 c irc uit p ac k, remove it first and rep lac e it with the new one. 1. Insert the TN799B c irc uit p ac k into the p ort slot id entified earlier. NOTE: To p rop erly seat the c irc uit p ac k, p ush firmly on the front of the fac ep late until the latc h reac hes the bottom rail of the c arrier. Then c lose the latc h until it is fully eng ag ed . Figure Notes 1. LCD d isp lay 2. Reset b utton (rec essed ) 3. Red b oard status LED4. PCMCIA c ard slot 5. Yellow PCMCIA d isk-in-use LED 1 2 3 4 5 fpdfmapd KLC 030899
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-52 Add IP Interface Assembly 6 2. Insert the TN802B IP Interfac e into the rig ht most of the three slots you reserved for it (see Figure 6-23 ) and seat it p roperly. When you p lug in the TN802B IP Interfac e Assemb ly, the c irc uit p ac k starts to b oot and the LCD read s PC Boot . The c irc uit p ac k reboots automatic ally, and after ab out 3 to 4 minutes the LCD c hang es to IPTRK* , the d efault mod e, or MEDPRO* . If the TN802B is pre-ad ministered at the fac tory, it reb oots several times to initialize to Med Pro mode. If the TN802B is not p re-ad ministered , g o to ‘‘Administration Steps’’ on page 6-53 NOTE: For an initial installation, the TN802B IP Interfac e need s to b e administered first (see ‘‘Administer the IP Interface’’ on page 6-53 ). Figure 6-23. J58890MA-1 L30 IP Interface Assembly 456 789 1 0 1 11 21 3 1 41 51 6 ndfmapd KLC 031299 456 789 1 0 1 11 21 3 1 41 51 6 indfmapd KLC 031299
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-53 Add IP Interface Assembly 6 Administer the TN799B C-LAN Refer to the DEFINITY Enterp rise Communic ations Server Ad ministration for Network Connec tivity . Administer the IP Interface Ad ministration is usually d one remotely; c all your servic e rep resentative to start the process. Administration Steps NOTE: Refer to the DEFINITY Enterp rise Communic ations Server Ad ministration for Network Connec tivity for Release 8 for sp ec ific information. 1. Log in as craft . 2. Type change node-names and p ress En te r. 3. On sc reen 2, typ e in the node name and IP add ress for the TN802B. 4. Type change circuit-pack and p ress En te r. 5. Chec k the Cod e c olumn to see if the slots ab ove the TN802B say DSMAPD or MEDPRO. change node-names Page 2 of 6 NODE NAMES Name IP Address Name IP Address clan-a1 192.168.1 .31 . . . clan-b1 192.168.2 .31 . . . default 0 .0 .0 .0 . . . med-a1 192.168.1 .81 . . . . . . . . . . . . . . . . . . . . . . . . . . .
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-54 Add IP Interface Assembly 6 . 6. If not, typ e MEDPRO in the slot just ab ove TN802B slot and p ress En t e r. Chang ing the one entry automatic ally c hang es the entry ab ove it. If it is in IP Trunk mod e, you g et the following error messag e: MedPro type requires TN802 with application. Type MEDPRO on circuit-packs form. 7. Type change ip-interfaces and press En te r. 8. Typ e in the information for the TN802B IP Interfac e, 9. Set the Enabled field to y , and press En te r. NOTE: The c ustomer provid es the IP add ress, sub net mask, and g ateway address. At this time the TN802B LCD read s PC BOOT * , and ab out 3 to 4 minutes later read s MEDPRO * with the asterisk flashing change circuit-packs Page 1 of 5 CIRCUIT PACKS Cabinet: 1 Carrier: A Carrier Type: processor Slot Code Sf Mode Name Slot Code Sf Mode Name 11: MEDPRO RESERVED-IP 01: TN754 DIGITAL LINE 12: MEDPRO RESERVED-IP 02: TN758 POOLED MODEM 13: TN802 B MAPD BOARD 03: TN2144 ANALOG LINE 14: 04: TN746 B ANALOG LINE 15: 05 16: 06: TN771 C MAINTENANCE/TEST 07: TN464 F DS1 INTERFACE 08: TN2140 E&M TIE TRUNK 09: TN767 E DS1 INTERFACE 10: TN799 B CONTROL-LAN # indicates circuit pack conflict.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-55 Add IP Interface Assembly 6 . Test the External Connection to the LAN To test the external IP c onnec tions, p ing the IP Interfac e server, and p ing a known c omp uter c onnec ted to your network. If everything is c onfig ured c orrec tly, the Result c olumn on the Ping Results sc reen read s pass . If it read s abort , verify the IP-ad d ress information and c hec k the c onnec tivity, inc lud ing the cabling. 1. Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and p ress En t e r. Th e v a r i a b l e nnn.nnn.nnn.nnn is the IP ad d ress of the TN802B IP Interfac e and UUCSS is the c ab inet, c arrier, and slot of the TN802B IP Interfac e. 2. Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and p ress En t e r. Th e v a r i a b l e nnn.nnn.nnn.nnn is the IP ad d ress of the c ustomer’s g ateway and UUCSS is the c ab inet, c arrier, and slot of the TN802B IP Interfac e. change ip-interfaces Page 1 of 2 Network regions are interconnected? n En- Net abled Type Slot Code Sfx Node Name Subnet Mask Bcast/Gway Addr Rgn n C-LAN 01A09 TN799 clan-a1 255.255.255.0 192.168.1 .100 1 y MEDPRO 01A13 TN802 B med-a1 255.255.255.0 192.168.1 .21 1 n 255.255.255.0 . . . n 255.255.255.0 . . . n 255.255.255.0 . . . n 255.255.255.0 . . . n 255.255.255.0 . . . n 255.255.255.0 . . . n 255.255.255.0 . . . n 255.255.255.0 . . . n 255.255.255.0 . . . n 255.255.255.0 . . . n 255.255.255.0 . . . n 255.255.255.0 . . . n 255.255.255.0 . . . ping ip-address 192.168.10.21 PING RESULTS End-pt IP Port Port Type Result Time(ms) Error Code 192.168.10.21 01A13 MEDPRO PASS 10 1124
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-56 Add IP Interface Assembly 6 3. Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and p ress En t e r. Th e v a r i a b l e nnn.nnn.nnn.nnn is the IP ad d ress of another c omp uter b eyond the g ateway and UUCSS is the c ab inet, c arrier, and slot of the TN802B IP Interfac e. The TN802B IP Interfac e is now installed in the DEFINITY c arrier and c onnec ted to the IP network. Installing in IP Trunk Mode NOTE: IP Trunk mod e should only b e used to maintain c omp atib ility with existing Release 7 IP Trunk or ITS-E installations. We strong ly rec ommend that Med Pro mod e b e used whenever p ossib le. Prepare for Installation Have the following eq uip ment on site b efore your ship ment arrives: nA mouse, keyboard , and VGA monitor for use d uring the installation of the server. You also need AC p ower outlets for the mod em and monitor. nThree ad joining , unoc c up ied p ort slots in the DEFINITY ECS The TN802B IP Interfac e slid es into only 1 slot, b ut its fac ep late oc c up ies 3 slots. nA 10 BaseT or 10/100 BaseT Ethernet c onnec tion into the c ustomer’s loc al area network (LAN) nA valid , unused IP ad d ress on the c ustomer’s LAN that c an b e assig ned to the IP Interfac e server. You also need the sub net mask, d efault g ateway, d omain name, and so forth from the c ustomer’s network ad ministrator. nAn analog telep hone line reserved for the IP Interfac e d iag nostic mod em nA valid telep hone numb er reserved for the IP Interfac e d iag nostic mod em If non-U.S. c ustomer: nMod em c omp arab le to a U.S. Rob otic s, Inc . Sp ortster Mod el USR 33.6 EXT. nA c ab le from the mod em to the TN802B external c ab le assemb ly. We rec ommend that you p rotec t the c ab inet where the IP Interfac e is installed with an uninterrup tib le p ower system (UPS).
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-57 Add IP Interface Assembly 6 Check your Shipment When your DEFINITY ECS ord er arrives at the c ustomer’s site, c hec k the c ontents (see Table 6-6 ). 1. Insp ec t the ship p ing c arton for d amag e b efore op ening it. If the b ox is damaged, do not open it. Inform the ship p ing c omp any, and ask for instruc tions on filing a c laim. 2. If the b ox is und amag ed , c hec k the c ontents ag ainst the p ac king slip . Chec k the c ondition of eac h c omp onent, and note any d amag e or shortag es on the p ac king slip . The c arton should c ontain the following for eac h IP Interfac e ord ered : . The TN802B external c ab le assemb ly is a bund le of c ab les with an amp henol c onnec tor at the end of the b und le and various PC-typ e c onnec tors (VGA, Universal Serial Bus [ USB] , mouse, keyb oard , Ethernet, mod em, and COM2) at the end s of the ind ivid ual c ab les. See Figure 6-24 . Look for the lab el where the b und le enters the amp henol c onnec tor. Table 6-6. Required Hardware Comcode/Code Description Quantity J58890MA-1 L30 TN802B IP Interfac e Assemb ly 1 601939804 H600-512,G1 external c ab le assemb ly 1 407633999 U.S. Rob otic s Sp ortster external mod em, mod el numb er USR 33.6 EXT (U.S. c ustomers only) 1 1. For non-U.S. customers, you need a mod em c omparable to the U.S. Rob otic s Sp ortster and a serial c able. 1 601087091 20-ft DB-25 serial c ab le from modem to TN802B external c ab le assemb ly (U.S. c ustomers only) 2 1
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-58 Add IP Interface Assembly 6 Figure 6-24. TN802B IP Interface External Cable Assembly 3. Read and follow any d irec tions inserted into the p ac kag e b y the fac tory. Connect the Cables 1. Determine into whic h p ort slot you are p utting the TN802B IP Interfac e. NOTE: Make sure that at least 3 ad joining slots are free. 2. From the rear of the c ab inet, c onnec t the amp henol c onnec tor on the external c ab le assemb ly to the b ac kp lane c onnec tor c orrespond ing to that slot (the hig hest numbered c onnec tor of the 3 slots required ). Figure Notes 1. Amp henol c onnec tor to c onnec tor c orresp ond ing to TN802B slot 2. To VGA monitor 3. To USB (not used ) 4. To keyb oard5. To mouse 6. To ethernet 7. 25-p in male c onnec tor to mod em 8. 25-p in male c onnec tor to COM2 cbdfocto AWF 122398 2 1 345678