    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-43 Standard Reliability 
    5
    Back Up Disk
    1. Type backup disk
     and  p ress En t e r to backup all changed files.
    2. Type test stored-data long
     and press 
    En t e r. This instructs the system to 
    verify the c onsistenc y of the MSS files (on the d isk and  removab le med ia).
    Return Replaced Equipment
    Return unused  G2 eq uip ment to Luc ent Tec hnolog ies ac c ord ing  to the 
    req uirements outlined  in:
    BCS/Material Log istic s, MSL/Attend ed  Stoc king  Loc ations
    Method s and Proc ed ures for Basic  Material Returns 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-44 High Reliability 
    5
    High Reliability
    Required Hardware
    The eq uip ment in Table 5-10 must be on-site before the upgrade begins. To 
    plac e a claim for missing equipment, as part of the Streamlined Implementation 
    p roc ess, c all 1-800-772-5409, or the numb er p rovid ed  b y your Luc ent 
    Tec hnolog ies rep resentative.
    Table 5-10. Required Hardware
    Equipment Description Quantity
    J58890A
    (PEC 6300-05X)Pro c e s s o r  Po r t  N e t w o r k 1
    J58890AF Exp ansion Control Carrier 1
    106647985 TN775B Maintenanc e 1
    103557294
    or
    103281788TN776 Exp ansion Interfac e
    TN570 Exp ansion Interfac e2 or 6 
    1
    2 or 6 1,2
    1. Use 2 for a hig h reliab ility system with 2 p ort networks; 6 with 3 port networks. Either 1
    or 4 Exp ansion Interfac es (EIs) ship loose with the EPN eq uip ment. The factory has
    installed  either 1 or 2 EIs in the new PPN.
    2. Req uired  port network interfaces in a Release 8 system with the op tional p ac ket bus.
    J58890TO-1 L1 Removab le Med ia 4
    407439975 20-Foot Multi-mod e Fib er Op tic  Cab le 1 or 3 
    3
    3. Use 2 or 6 if the PPN and EPN(s) are remotely loc ated . The fib er that p reviously
    connec ted  an up g raded  G2 universal module (not a trad itional mod ule) to the G2 TMS
    has the c orrec t transc eiver connectors and , therefore, c an b e reused.
    106455348
    or
    1064553639823-A Lig htwave Transc eiver
    9823-B Lig htwave Transc eiver2 or 6 4
    2 or 6 5
    4. One p air for eac h fiber c onnec tion. For eac h c onnec tion, install one 9823-typ e
    lig htwave transc eiver in an EPN and  1 in the PPN. A 9823-typ e transceiver c an b e
    reused  from eac h upg raded  G2 universal mod ule. Add itional transceivers also ship
    loose with the EPN equipment. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-45 High Reliability 
    5
    Required Tools
    The following tools and  items may b e req uired  d uring  the up g rad e:
    nHig h-intensity flashlig ht or AC d rop  lig ht
    n3/8-inc h flat-b lad e sc rewd river with a 10-inc h shank (minimum)
    n5/16-inc h and  1/4-inc h soc kets with a ratc het and  10-inc h extension
    nLong -nose p liers to d isc onnec t ground  straps and  straig hten b ac kplane 
    pins
    nStatic -p roof or orig inal c irc uit p ac k p ac kag ing  for transp orting  c irc uit 
    packs
    nLab els for id entifying  the p ort c irc uit p ac ks and  c ab les attac hed  to the 
    rear of c ab inets
    nTwelve sp are #12 and  #10 self-tap p ing  sc rews
    nFour sp are c arrier g round  strap s
    nWrist ground strap
    nRep air kit for b ac kp lane p ins (KS-22876 L2 or eq uivalent)
    nOne c op y of eac h of the following  manuals:
    — DEFINITY Enterp rise Communic ations Server Release 8 
    Maintenanc e for R8r
    — DEFINITY Enterp rise Communic ations Server Release 8 
    Ad ministrator’s Guid e
    Follow Routine Preventive Maintenance
    Follow routine p reventive maintenanc e p roc ed ures on the system to b e 
    up g rad ed . For information ab out the p roc ed ures and  nec essary eq uip ment, refer 
    to the “ Preventive Maintenanc e”  sec tion in 
    DEFINITY Enterp rise Communic ations 
    Server Release 8 Maintenanc e for R8r
    .
    Label Cables
    To make rec onnec ting  the c ab les simp ler and  more reliable, lab el b oth end s of 
    the c onnec tor c ables assoc iated with the c arrier to b e removed . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-46 High Reliability 
    5
    Check Link Status
    1. Type display communication-interface links
     and p ress En te r. Write d own 
    all enab led  links.
    2. Type status link
     
    number and  p ress En t e r. Rep eat this step  for all links.
    3. Write d own whic h links are in servic e.
    Disable TTI
    !CAUTION:
    If you d o not d isab le the TTI, the translations c an b e c orrup ted .
    1. Make sure the ISDN is in servic e. If not, attempt to b usy out and release 
    the ISDN D-c hannel/link. This will b ring  the ISDN trunks b ac k into servic e.
    2. Type change system-parameters features
     and press 
    En t e r. 
    3. On the sec ond  sc reen, set the Enabled?
     field  to n
     to p revent the TTI 
    feature from ac tivating .
    Power Down G2 System
    At the power d istribution unit, set the main c irc uit b reaker to OFF.
    Install Power-Failure Transfer Ground Wire
    !CAUTION:
    To avoid  c ontaminating  sing le-p oint g round , d o not c onnec t the g round  wire 
    while the system is p owered  up .
    1. Connec t a 10 AWG (#25) (2.6 mm2) wire to p in 49 of the c onnec ting  b loc k 
    or to pin 49 of the CAP (c ab le ac c ess p anel) on the p ower-failure transfer 
    p anel.
    2. Route the op p osite end  of the wire to an ap p roved  g round  and  c onnec t. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-47 High Reliability 
    5
    Disconnect Cables
    1. With the c ab le retainer in front of you and  the p art numb er visib le (4B or 
    4C), loc ate the slot that is almost vertic al. This slot is ad jac ent to the p art 
    numb er. Insert a #2 flat b lad e sc rewd river into the slot and  twist. The 
    retainer will snap  op en easily. Remove the c able.
    2. Disc onnec t the c ab les assoc iated  with the c arrier to b e removed .
    3. Remove the rear d oors from the c ab inet.
    4. Remove all of the rear p anels. Two d ifferent typ es of sc rews hold  the 
    p anels to the c ab inet. Remove the #10 sc rews with a sc rewd river or a 
    1/4-inc h soc ket. Remove the #12 sc rews with a sc rewd river or a 5/16-inc h 
    soc ket.)
    Remove Circuit Packs from Module Control 
    Carrier A
    1.To ensure that p ower units in the “ A”  c arrier are p rop erly rep lac ed , lab el 
    eac h p ower unit with its slot number.
    2. Disc onnec t the p ower c ords from the p ower units in the “ A”  c arrier.
    3. Remove all c irc uit p ac ks and  p ower units from c arrier “ A.”  Store the c irc uit 
    p ac ks in the static -p roof p ac kag ing .
    4. Remove the c irc uit p ac k b lanks from the emp ty slots.
    5. Remove the front trim p late from the “ A”  c arrier b y p ulling  it straig ht off.
    Remove CURL from Module Control Carrier A
    Remove the CFY1 c urrent limiter (CURL) from the p in-field  b loc k marked  “ CURL”  
    on the “ A”  c arrier. The CURL will b e reused  in the Release 8 EPN.
    NOTE:
    Verify that the CURL meets the minimum usab le vintag e req uirements.
    Remove Module Control Carrier A
    NOTE:
    Note the p osition of eac h TDM/LAN c ab les b efore disc onnec ting .
    1. Disc onnec t b oth TDM/LAN c ab les from the “ A”  c arrier. See Figure 5-10
    . 
    Leave the other end  c onnec ted  to the “ C”  c arrier. 
    !CAUTION:
    When removing the TDM/LAN c ab les from a previously up g rad ed  
    c arrier, b e c areful that none of the short p iec es of shrink tub ing c ome 
    off the 4 c orner p ins of the p in-field  b loc k. Otherwise, when the new 
    eq uip ment is c onnec ted, -48 volts c ould  short to g round . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-48 High Reliability 
    5
    2. On p ort c arrier J58890BB-1, c onnec t the TDM c ab le or TDM terminator to 
    Slot 02. On p ort c arriers J58890BB-2 and  J58890BB-3, c onnec t the TDM 
    c ab les to Slot 01.
    Figure 5-10. TDM/LAN Connections for High Reliability System Figure Notes
    1.Port Carrier (“ C” Position)
    2. ZAHF4 TDM/LAN Terminator
    3. TDM/LAN Cab le (WP91716 L6)
    4. Mod ule Control Carrier (“ A”  Position)
    5. Port Carrier (“ D” Position)6 . Po r t  C a rr i e r  ( “ E”  Po si t io n )
    7. Slot 21
    8. Slot 01
    9. TDM/LAN Cable (WP91716 L7) 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-49 High Reliability 
    5
    3.Disc onnec t the 16 g round  strap s from the top  and  b ottom of the “ A”  
    c arrier. See Figure 5-11
    . These strap s rec onnec t to the new “ A”  c arrier.
    Figure 5-11. Locations of Ground Jumpers Figure Notes
    1. Rear of Cab inet
    2. Port Carrier (“ C” Position)
    3. Ground  Jump ers4. Mod ule Control Carrier (“ A”  Position)
    5. Port Carrier (“ D”  Position) 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-50 High Reliability 
    5
    4.Disc onnec t the “ P1”  and  “ P2”  c ab les from the “ A”  c arrier. See Figure 5-12. 
    5. Slid e the latc h up , and  d isc onnec t the “ P1”  c ab le from the “ B”  c arrier. 
    Figure 5-12. Location of P1 and P2 Connectors
    6. Remove the fan trim p late by p ulling  it straig ht off.
    7. Clean or rep lac e the air filter (403326820) if nec essary.
    8. In the front of the c arrier, remove the 4 sc rews (top 2 first) hold ing  the “ A”  
    c arrier to the c ab inet frame. Use a long  hand le sc rewdriver or 5/16-inc h 
    soc ket with a 10-inc h (25 c m) extension.
    9. Behind  the c arrier, remove the 2 sc rews hold ing  the “ A”  c arrier’s rear 
    c onnec tor p anel to the c ab inet frame.
    10. Slid e the c arrier forward  1 to 2 inc hes (2.5 to 5 c m). Be sure that no c ab les 
    or wiring  harnesses are c aug ht on the c ab inet/c arrier framework.
    !CAUTION:
    Cab les and  wiring harnesses c an be d amag ed  if they c atc h on the 
    framework and  if too muc h pressure is ap p lied  in removing  the 
    carrier.
    11. Remove the c arrier b y slid ing  it out the front of the c ab inet. Figure Notes
    1. Rear of Control Carrier
    2. P2 Connec tor3. P1 Connec tor 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-51 High Reliability 
    5
    Unpack and Inspect Expansion Control Carrier
    1. Insp ec t the new J58890AF Exp ansion Control Carrier for any d amag e. 
    Also verify that the b ac kp lane p ins are not b ent.
    2. Plac e the exp ansion c ontrol c arrier on the floor so that the rear of the 
    carrier faces up.
    3.Install the CFY1 c urrent limiter (CURL) on the “ A”  c arrier to the p in-field  
    b loc k marked  “ CURL.”  Install the CURL with the c omp onents on the left.
    4. At the rear c onnec tor p anel, d etermine whic h c onnec tors will have a c ab le 
    attac hed , and  install a 4B c ab le retainer on eac h of these c onnec tors.
    Install New Expansion Control Carrier A
    1. Install the c arrier in p osition “ A”  b y alig ning  the p lastic  alig nment tip s on 
    the top  rear of the c arrier with the sc rew holes in the c ab inet. These 
    alig nment tip s sup p ort the c arrier while installing  the sc rews. Ensure that 
    the p ower c ord s are prop erly p lac ed  in the slots at the sid es of the c arrier.
    2. Fasten the c arrier into p osition with the 4 self-tap p ing  sc rews saved  from 
    the removal of the old  c arrier.
    !CAUTION:
    Carefully realig n the thread s on the self-tap ping  sc rews b y turning  
    them c ounterc loc kwise 1 turn b efore tig htening  them to avoid  
    stripping the threads out of the framework.
    3. Behind  the c arrier, rep lac e the 2 sc rews saved  from the removal of the old  
    carrier.
    4. Connec t the “ P2”  and  “ P1”  c ab les to the “ A”  c arrier. See Figure 5-12
    . 
    Snap  the c onnec tor loc k into p lac e to ensure the c onnec tion is p rop erly 
    mad e.
    5. Connec t the “ P1”  c ab le to the “ C”  c arrier. Snap  the c onnec tor loc k into 
    p lac e to ensure the c onnec tion is p rop erly mad e.
    6. Connec t the 8 g round  strap s from the “ D”  c arrier to the new “ A”  c arrier 
    See Figure 5-11
    . These straps were left c onnec ted  to the “ D”  c arrier.
    7. Connec t the 8 g round  strap s from the “ C”  c arrier to the new “ A”  c arrier. 
    These strap s were left c onnec ted  to the “ C”  c arrier.
    8. For an AC-powered system, install the 2 new carrier ground straps. One 
    strap  c onnec ts g round  point “ 1”  to the A-c arrier frame (rig ht sid e), and the 
    other c onnec ts ground  p oint “ 8”  to the A-c arrier frame (left sid e).
    NOTE:
    DC-p owered  c arriers d o not use these c arrier g round  strap s. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-52 High Reliability 
    5
    9.Connec t the remaining end  of the TDM/LAN c able (b etween the “ A”  and  
    “ D”  c arriers) to the pin-field  bloc k marked  “ TDM”  on the rig ht sid e of the 
    “A” carrier. See Figure 5-13
     and Table 5-11. The other end  remained  
    c onnec ted  to the “ D”  c arrier when the old c arrier was removed .
    10. Connec t the remaining end  of the TDM/LAN c able (b etween the “ A”  and  
    “ C”  c arriers) to the p in-field  b loc k marked  “ TDM”  on the left sid e of the “ A”  
    c arrier. The other end remained  c onnec ted  to the “ C”  c arrier when the old  
    carrier was removed .
    11. On p ort c arrier J58890BB-1, c onnec t the TDM c ab le or TDM terminator to 
    Slot 02. On p ort c arriers J58890BB-2 and  J58890BB-3, c onnec t the TDM 
    c ab les to Slot 01. 
    						
    All Lucent Technologies manuals Comments (0)