    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5r/R6r/R7r to R8r without Adding Memory 
    2-11 Upgrade the software and hardware 
    2
    Remove the Circuit Packs
    NOTE:
    More detailed  information on removing and  add ing  c irc uit p ac ks is in 
    Chapter 6, ‘‘Adding or Removing Cabinet Hardware’’
    .
    1. Remove the b lank fac ep late next to the MSSNET slot in the c arrier.
    2. Remove the UN332B circuit pack from the carrier and place it in antistatic  
    packing material.
    3. Remove the TN1656 tap e d rive and  p lac e it in antistatic  p ac king  material. 
    Install the Circuit Packs
    NOTE:
    To p rop erly seat a c irc uit p ac k, p ush firmly on the front of the fac eplate until 
    the latc h reac hes the b ottom rail of the c arrier. Then c lose the latc h until it is 
    fully engaged.
    1. Insert the UN332C c irc uit p ac k into the MSSNET slot.
    2. Rep lac e the b lank fac ep late next to the MSSNET c irc uit p ac k.
    3. Insert the TN2211 optical drive (Figure 2-1
    ) into the rig ht most TAPE DRIVE 
    slot. It only takes up 2 slots.
    4. Plac e a b lank fac eplate over the left most TAPE DRIVE slot.
    Figure 2-1. TN2211 Optical Drive
    Red
    Green
    Yellow
    fpdf2211 KLC 010600TN2211 OPTICAL DRIVE 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5r/R6r/R7r to R8r without Adding Memory 
    2-12 Upgrade the software and hardware 
    2
    5. Plac e the formatted  removab le med ia, lab el fac ing  left, into the op tic al 
    drive.
    NOTE:
    Make sure the formatted removab le med ia is not write-p rotec ted 
    b efore p lac ing  it into the op tic al drive 
    (see Figure 2-2).
    Figure 2-2. Make sure the disk is not write-protected.
    !CAUTION:
    The removab le media has a slid ing , metal c over to p rotec t the 
    surfac e of the d isk. DO NOT TOUCH THE DISK (see 
    Figure 2-3).
    Figure Notes
    1. Not write-p rotec ted 2. Write-p rotec ted
    h1dfdsk KLC 112499
    12 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5r/R6r/R7r to R8r without Adding Memory 
    2-13 Upgrade the software and hardware 
    2
    .
    Figure 2-3. Do not touch the disk inside the cartridge.
    Power Up the Processor Carrier
    1. To restore p ower to the p roc essor c arrier, insert the p ower p lug  on the 
    right side of the c arrier then insert the p ower p lug  on the left sid e of the 
    carrier.
    If hig h or c ritic al reliab ility:
    2 . M o n it o r t h e  SPE a s  it  re b o o t s b y  o b se r vi n g  t h e  L ED s  a n d  t h e  t e r m in a l.  I t  is  
    p owered  up  when the YELLOW LED on the Proc essor c irc uit p ac k b links 
    in a stead y state, whic h takes ab out 10 minutes.
    Unlock the Active SPE (H/C only)
    1. Move the SPE SELECT switc hes to the AUTO position one at a time.
    2. Wait 10 minutes.
    !CAUTION:
    Allow 10 minutes after unlocking to make sure the standby SPE has 
    fully returned  to servic e.
    640MB
    2048B
    Y
    T
    E
    S
    /S
    E
    C
    TO
    R
    h1dfdsk1 KLC 091799 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5r/R6r/R7r to R8r without Adding Memory 
    2-14 Upgrade the software and hardware 
    2
    Verify Interchange (H/C only)
    1. Type status spe
     and press En t e r to make sure the stand b y sid e is read y for 
    interc hange:
    nTh e  Standby Refreshed
     field  shows yes
    nTh e  Standby Shadowing
     field  shows on
    nTh e  Standby Handshake
     field  shows up
    I f  t h e  s t a n d b y  SPE d o e s n o t  f u ll y re t u r n  t o  se rv i c e ,  re f e r t o  t h e  STB Y-SPE 
    Maintenanc e Ob jec t sec tion in the 
    Maintenanc e b ook. 
    Upgrade Other Carrier (H/C only)
    To  u p g r a d e  t h e  o t h e r  c a r r ie r,  lo c k t h e  SPE s w i t c h e s o n  t h e  D U PI N T t o  t h e  o t h e r 
    carrier. 
    NOTE:
    The new ac tive c arrier resets (reset 1). Wait until the log in p romp t ap p ears, 
    then log  in.
    Rep eat the step s from Check the Active Tone-Clock (H/C only)
     through Verify 
    Interchange (H/C only).
    Affix position label(s) 
    1. Plac e the new strip  lab el(s) over the old  c arrier lab el(s).
    Verify software version
    NOTE:
    Th e  Tape Resident
     field  shows the software load  numb er. Write it d own 
    for use later.
    If stand ard  reliab ility:
    1. Type list configuration software-version 
    and press 
    En t e r to verify that the 
    removab le media c ontains the Release 8 software.
    If hig h or c ritic al reliab ility:
    1. Type list configuration software-version long
     and  p ress 
    En te r  to verify 
    that the removab le media c ontains the Release 8 software. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5r/R6r/R7r to R8r without Adding Memory 
    2-15 Upgrade the software and hardware 
    2
    Save Translations
    1. Type save translations tape 
    and press En t e r  to save translations to the 
    new removab le med ia, whic h takes ab out 2 minutes.
    Save Announcements (if necessary)
    1. Type save announce
     tape
     and press En te r to save announc ements to the 
    new removab le med ia.
    Restore Disk 
    If stand ard  reliab ility:
    1. Type restore disk full
     and  p ress 
    En te r to write the new software  to d isk. 
    Release 8 system software is now resident on the d isk.
    If hig h or c ritic al reliab ility:
    2. Type restore disk full both
     and press 
    En t e r to write the new software to 
    disk. 
    NOTE:
    This c ommand  may take up  to 25 minutes to c omp lete. Until this 
    c ommand  finishes, the system p rovid es no user feed b ac k on the 
    system ac cess sc reen. Do not p ress 
    En t e r while the c ommand  
    exec utes. Doing  so c lears the terminal sc reen as the c ommand  
    finishes, erasing any suc c ess or failure messag es the system may 
    provide.
    Upgrade Software 
    This c ommand  c op ies the software from the removab le med ia to the system d isk 
    and  takes ab out 15 minutes to c omp lete. 
    For stand ard  reliab ility:
    !CAUTION:
    All c alls are d rop p ed —this is a service interrup tion.
    1. Type upgrade software G3V8r.xx.x.xxx.x 
    (entire alp hanumeric  string of 
    new software version) and  p ress 
    En te r. At the prompt, press En t e r to save 
    translations. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5r/R6r/R7r to R8r without Adding Memory 
    2-16 Upgrade the software and hardware 
    2
    For hig h or c ritic al reliab ility:
    1. Type upgrade software G3V8r.xx.x.xxx.x no-calls 
    (entire alp hanumeric  
    string  of new software version) and  p ress 
    En te r. At the prompt, press En t e r 
    to save translations and  attemp t to p reserve c alls ac ross the interc hang e.
    For all reliabilities:
    2. After the system resets, log  in as craft
    . 
    3. Check for the Translation Corruption Detected
     message before 
    p roc eed ing  with the up g rad e. If c orruption is d etec ted , refer to No 
    Translations After Upgrade in Appendix B, ‘‘Troubleshooting  an Upgrade’’ 
    to c orrec t the p rob lem. 
    !CAUTION:
    Do not c ontinue with the up g rad e until the translations errors are 
    corrected. 
    Reset SPE status (H/C only)
    1. Type status SPE
     and press En te r. Wait until the Standby Handshake
     
    field displays up, which takes about 3 minutes.
    2. Type reset spe-standby 4
     and  p ress 
    En te r.
    NOTE:
    Yo u  c a n  c o n t i n u e  t h e  p ro c e ss  w h il e  t h e  SPE is  re se t t i n g .
    Set Daylight Savings Rules
    You c an set up  to 15 c ustomized  d aylig ht saving s time rules. If you have c ab inets 
    in several different time zones, you c an set up  rules for eac h on a loc ation b asis. 
    A d aylig ht saving s time rule sp ec ifies the exac t time when you want to transition 
    to and  from d aylig ht saving s time. It also sp ec ifies the inc rement at whic h to 
    transition. 
    NOTE:
    The d efault d aylig ht saving s rule is 0
    , no d aylig ht saving s.
    1. Type change daylight-savings-rules
     and press 
    En t e r. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5r/R6r/R7r to R8r without Adding Memory 
    2-17 Upgrade the software and hardware 
    2
    2. Type the appropriate start and stop information in the Change Day
    , 
    Month
    , Date
    , Time
    , and  Increment
     field s for eac h rule. (for examp le, 
    1:00
     eq uals one hour) 
    NOTE:
    You c an c hang e any rule exc ep t rule 0 (zero). You c annot delete a 
    d aylig ht saving s rule if it is in use on either the Loc ations or Date and 
    Ti m e  s c re e n s .
    3. When d one, p ress 
    En te r.
    Set Date and Time
    1. Type set time 
    and 
    press En t e r to b ring  up  the Date and  Time sc reen.
    .
     
    DAYLIGHT SAVINGS RULES
    Rule Change Day Month___Date Time____Increment
    0: No Daylight Savings
    1: Start: first Sunday
    ___ on or after April___ 1  at _2:00 01:00Stop:  first Sunday___ on or after October_ 25 at _2:002: Start: first _________ on or after _________ __ at __:__
    Stop:  first _________ on or after _________ __ at __:__
    3: Start: first______ on or after ____ __ at __:__
    Stop:  first ______ on or after ____ __ at __:__
    4: Start: first _____ on or after ____ __ at __:__
    Stop:  first ______ on or after ____ __ at __:__
    5: Start: first _____ on or after ____ __ at __:__
    Stop:  first ______ on or after ____ __ at __:__
    6: Start: first _____ on or after ____ __ at __:__
    Stop:  first ______ on or after ____ __ at __:__
    7: Start: first _____ on or after ____ __ at __:__
    Stop:  first ______ on or after ____ __ at __:__
     
                               DATE AND TIME
    DATE
     Day of the Week: Tuesday
    Month: FebruaryDay of the Month: 8 Year: 2000
    TIME
    Hour: 20 Minute: 30Second: XX Type: standardDaylight Savings Rule: 0 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5r/R6r/R7r to R8r without Adding Memory 
    2-18 Upgrade the software and hardware 
    2
    2. Typ e the d ay in Eng lish (Sund ay throug h Saturd ay) in the Day of the 
    Week:
     field. See Table 2-3
     for Eng lish d ay names When done, p ress Ta b to 
    move to next field .
    3. Typ e the c urrent month in Eng lish (January throug h Dec emb er) in the 
    Month:
     field . See Table 2-4
     for Eng lish month names. When d one, p ress 
    Ta b to move to next field .
    4. Typ e the d ay of month (1 throug h 31) in the Day of the Month:
     field  
    and  p ress 
    Ta b to move to the next field .
    5. Typ e the c urrent year in the Year:
     field  and p ress 
    TA B to move to the next 
    field .
    6. Typ e the c urrent hour for a 24-hour c loc k in the Hour:
     field  and p ress
     Ta b 
    to move to the next field .
    7. Typ e the c urrent minute (0 throug h 59) in the Minute:
     field  (sec ond s 
    c annot b e set). When d one, p ress 
    Ta b to move to next field
    Table 2-3. English Day of the Week Names
    Day Number Day Name
    1Sunday
    2 Mond ay
    3Tuesday
    4 Wed nesd ay
    5Thursday
    6Friday
    7Saturday
    Table 2-4. English Month Names
    Number Name Number Name
    1 January 7 July
    2February8August
    3 Marc h 9 September
    4 April 10 October
    5 May 11 Novemb er
    6 June 12 December 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5r/R6r/R7r to R8r without Adding Memory 
    2-19 Upgrade the software and hardware 
    2
    8. Type standard
     or daylight savings
     in the Type
     field , ac c ord ing  to the 
    c urrent time in the loc al time zone. For examp le, if c urrently on stand ard  
    time, typ e standard
    .
    9. Typ e the rule numb er in the Daylight Savings Rule
     field .
    10. When all the information is c orrec t, p ress 
    En t e r.
    11. Typ e display time 
    and press 
    En te r  to verify d ate and  time d ata.
    Set Core Dump Vector
    1. Type set vector f spe-maint
     and p ress En te r  to set the c ore d ump  vec tor to 
    p erform a c ore d ump  on any system restart. 
    Enable TTI
    NOTE:
    Do this step  only if the TTI is d isab led  and  you want it enab led .
    1. Type change system-parameters features
     and p ress 
    En te r to change the 
    TTI field  b ac k to its value b efore the up g rad e.
    Release MMI (H/C only)
    1. Type release board cabinet carrier slot 
    and press En te r to release the 
    c irc uit p ac ks, whic h were b usied  out earlier.
    Resolve Alarms
    1. Type display alarms
     and p ress En t e r to examine the alarm log . Resolve 
    any alarms that may exist using  
    DEFINITY Enterp rise Communic ations 
    Server Release 8 Maintenanc e for R8r
    . 
    Check Link Status
    1. Type display communication-interface links
     and press En te r. Compare it 
    with the earlier status.
    2. Type status link
     
    number and  p ress En t e r. Rep eat this step  for eac h link.
    Enable Scheduled Maintenance
    1. Type change system-parameters maintenance
     and press En t e r.
    2. Typ e the ap p rop riate time in the Start
     field to enab le sc heduled d aily 
    maintenanc e. Make sure the Save Translation
     field  is set to daily
    . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5r/R6r/R7r to R8r without Adding Memory 
    2-20 Upgrade the software and hardware 
    2
    Enable Customer Options and Alarm Origination 
    to INADS
    1. Get the DOSS order number of the upgrade from the project manager and 
    ask the reg ional Customer Software Ad ministration to c omp lete the step s 
    in the shad ed  b ox. See ‘‘Where to Call for Tec hnic al Sup p ort’’ on p ag e -xx
     
    for telep hone numb ers.
    NOTE:
    As p art of the system reg istration p roc ess, the INADS Datab ase 
    Ad ministrator enab les Alarm Orig ination.
    2. When ad ministration is c omp leted , log  in as craft
    .
    Check SPE status (H/C only)
    1. Type status SPE
     and press En te r. Wait until 
    nTh e  Standby Refreshed
     field  shows yes
    nTh e  Standby Shadowing
     field  shows on
    nTh e  Standby Handshake
     field  shows up
    Save Translations
    1. Type save translation
     and press En te r to c op y up g rad ed  translations to 
    the system d isk, whic h takes ab out 2 minutes.
    init login administration:
    1. Log in as init
    .
    2. Type change system-parameters customer-options
     and press 
    En te r 
    to verify that the c ustomer op tions are p roperly set.
    3. Go to sc reen 6, QSIG Op tional Features, and  set the Basic Call 
    Setup 
    field  to y
     if the customer was using Supplementary Services 
    Protoc ol b  or d  on an ISDN-PRI trunk g roup  b efore the up g rad e.
    4. Type change system-parameters offer-options
     and  p ress 
    En te r.
    5. If the Activate Offer
     field  is n
    , set it to y 
    and press 
    Ta b. A warning  
    messag e lets you know whether you need  to save translations and  
    reb oot to make the c hang e p ermanent.
    6. Press 
    En t e r to effec t the c hang es or Canc el if there were no c hang es.
    7. Contac t the req uester when d one. 
    						