Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Fiber Link Administration A-1 Administer Fiber Links A DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 A Fiber Link Administration This ap p end ix desc rib es the step s req uired to ad minister fib er links on G3rV4 and later systems. Before starting the ad ministration p roc ess, verify the following : 1. Be sure all fiber op tic transc eivers and all fib er op tic c ab les are c orrec tly installed on the DS1 and /or DS1 c onverter c irc uit pac ks. 2. Verify c onnec tions to the Lig htg uid e Interc onnec t Units (LIUs) or shelves, to the fib er multip lexers, and to the outsid e world . Refer to Ap p end ix A in DEFINITY Enterp rise Communic ations Server Release 8 Installation and Test for Multic arrier Cabinets . Administer Fiber Links Ad minister system fib er link c onfig urations to matc h the hardware installed and ac c ord ing to the Fib er Op tic Cab le Running List. NOTE: Fib er link ad ministration interac ts with or d ep end s up on other system features that must b e ad ministered b efore it. Fiber link ad ministration c reates translation d ata by id entifying the end p oint p airs for eac h link. End p oints c an b e: nAn Exp ansion Interfac e (EI) c irc uit p ac k nA Switc h Nod e Interfac e (SNI) c irc uit p ac k
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-2 Administer Fiber Links A Circuit Pack Form After installing the eq uip ment (inc lud ing c irc uit p ac ks), the c irc uit p ac ks must b e ad ministered before the fib er link is ad ministered . Refer to DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e for more information. The following information d esc ribes general c irc uit pac k ad ministration information: a. Use the Circ uit Pac ks form to ad minister c irc uit p ac ks to c arrier slots. Install or ad minister the c irc uit p ac ks (or assig ned using the Circ uit Pac ks form) b efore ad ministering voic e terminals, attend ant c onsoles, or trunks. b . Eac h p ag e of the form rep resents 1 c arrier in the c ab inet shown on the c ommand line. c . Refer to DEFINITY Communic ations System Generic 3 Planning and Config uration for more information about c irc uit pack administration and port assignment records. d . For initial installation, assig n c irc uit p ac ks to slots using the hard ware configuration layout record from the fac tory or Customer Services Org anization. Do not arb itrarily assig n c irc uit p ac ks to slots. e. If the c arrier typ e ad ministered on the Cab inet Ad ministration form d oes not matc h the p hysic al hard ware, question marks (??) may d isp lay in the Code fields. f. When a c irc uit p ac k in a slot d iffers from what has b een ad ministered on the form, a “ #” d isp lays b etween the “ Sfx” and “ Name” field s to ind ic ate a conflict. g . For Release 8r, the numb er of slot fields d isp layed represents ad ministrab le slots for the g iven c arrier typ e.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-3 Administer Fiber Links A Administer Fiber Links on Simplex Systems Ad minister the TN570 Exp ansion Interfac e and the TN574 or TN1654 DS1 Converter circuit packs. 1. Type change circuit packs and press En te r. Sc roll throug h the p ag es on the form until the c arrier c ontaining the new c irc uit p ac ks d isp lays on the sc reen. 2. Enter the c irc uit p ac ks into the ap p rop riate slot loc ations on the form. Press En t e r when finished . 3. Type list fiber and press En te r. All ad ministered fiber c onnec tions display. 4. If a p reviously used fib er link is to b e reused , enter add fiber and p ress En t e r. If this is a new fib er link, typ e add fiber next and press En t e r. The Fib er Link Ad ministration sc reen ap p ears. Eac h fib er link is id entified b y a fib er numb er. a. Type y or n in the field Is one endpoint remoted via DS1 Converter complex? and press En te r. b . Enter the loc ation of the TN570 and the TN574 or TN1654 c irc uit p ac ks for b oth ENDPOINT-1 and ENDPOINT-2. c . Sc roll to p ag e 2 of the form. Enter y as ap plic ab le, in eac h Facility Installed? field (A, B, C, and D). d . In the Bit Rate: field , typ e either 1.544 (T1) or 2.048 (E1). e. Enter the id le c od e in the Idle Code MSB (1) . . . . LSB (8): field . The default value is 11101000 . It is rec ommend ed that the d efault value b e used unless it b ec omes ab solutely nec essary to c hang e it. The “ MSB” means Most Sig nific ant Bit, the “ LSB” means Least Sig nific ant Bit. f. In the Line Coding: field, enter the line coding information. This information should matc h the line c od ing of the fac ility. For T1, examp le line c od ing is b8zs . For E1, examp le line c od ing is hdb3 . NOTE: If this d ata is not c orrec t, wid eb and errors (multimed ia c all hand ling ) may oc c ur. 5. For T1 sites, refer to ‘‘T1 Installations Only’’ . For E1 sites, refer to ‘‘E1 Installations Only’’.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-4 Administer Fiber Links A T1 Installations Only 1. The Framing Mode: field is d isp lay only and shows the hard ware setting . 2. The DS1CONV-1 Line Compensation: and the DS1CONV-2 Line Compensation: field s are d isp lay only and show the hard ware setting . 3. In the Facility A Circuit ID: field , enter an op tional fac ility name that is uniq ue to eac h fac ility (up to 40 alp hanumeric c harac ters). Press En t e r. 4. A d isp lay similar to the following ap p ears after the fib er link ad ministration is c omp leted : RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED . E1 Installations Only 1. Type y or n in the CRC? field . The “ CRC” means Cyc lic Red und anc y Chec k. This is an error d etec tion alg orithm. 2. The Line Termination: field is d isp lay only. A 75 (75 Ohms) or 120 (120 Ohms) typ ic ally d isp lays. 3. In the Facility A Circuit ID: field , enter an op tional fac ility name that is uniq ue to eac h fac ility (up to 40 alp hanumeric c harac ters). Press En t e r. 4. A d isp lay similar to the following ap p ears after the fib er link ad ministration is c omp leted : RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED . All Installations 1. When the system reset is finished, type status port-network 2 and press En t e r. The Port Network Status sc reen ap p ears. Verify that PNC Ac tive is “ up ” and that the Servic e State is “ in.” 2. A Sp an LED, on the front of the DS1 Converter c irc uit p ac k, must b e on for eac h ac tive fac ility ad ministered . For examp le, if Fac ility A and Fac ility B are ad ministered , then the top 2 Sp an LEDs on the c irc uit p ac k must be on (yellow). The yellow LEDs are on only if no p rob lems were enc ountered d uring the ad ministration of hard ware. Sp an LEDs assoc iated with non-ad ministered fac ilities (C and D, in this example) should b e off. 3. Perform a test c all, if d esired .
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-5 Administer Fiber Links A Administer Fiber Links on Duplex Systems All non-d up lic ated Switc h Nod e Interfac es to Switc h Nod e Interfac e fiber links are automatic ally dup lic ated . When PNC Dup lic ation is enab led on the System-Parameters Customer-Op tions form, the following ad ministration forms change: nCab inet Form — Ad d itional field s ap pear to allow ad ministration of switc h nod es to A-PNC and B-PNC sid es of the CSS. The B-PNC is the d up lic ated hard ware for the A-PNC. Either the A-PNC or the B-PNC c an p rovid e full c ustomized servic e. B-PNC c annot b e used in a simp lex PNC configuration. Pairing of switc h nodes is also defined here. nFiber Link Ad ministration Form — Ad d itional field s ap p ear to allow ad ministration of fib er links on the B-PNC sid e of the CSS. If an end p oint on the A-PNC sid e is ad ministered as an SNI, its c orresp ond ing end point on the B-PNC sid e is d etermined (if switc h nod es are p aired in the c ab inet form p rior to this ad ministration) and d isp layed . However, ad ministration of the d uplic ate B-PNC link is not enforc ed until d up lic ation is in full op eration. nDup lic ation-Related System-Parameters Form — An ad d itional field ap p ears to enable op eration of PNC d uplic ation. 1. Type change system-parameters customer-options and press En te r. On Pag e 2 of the form, set the PNC Duplication? field to y . Press En t e r. 2. Type change system-parameters duplication and press En t e r. Chang e the Enable operation of PNC duplication? field to y . Press En te r. 3. Type status pnc and p ress En t e r. Verify the Duplicated ? field is yes . 4. Type list fiber and press En te r. All ad ministered fiber c onnec tions display. 5. If a p reviously used fib er link is to b e reused , typ e add fiber and p ress En t e r. If this is a new fib er link, typ e add fiber next and press En t e r. 6. The Fib er Link Ad ministration form app ears. On Pag e 1 of the form: a. Enter the Board Location: for Endpoint-1 and Endpoint-2. This is the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of an SNI or EI c irc uit p ac k that is the first end p oint of the fib er link. Rep eat for the remaining end p oints. b. The Board Type field is d isp lay only and shows the typ e of c irc uit pack in Endpoint-1. c . In the DS1CONV Board Location : field, enter the c abinet, c arrier, and slot that id entifies the p hysic al loc ation of DS1 Converter c irc uit p ac k in the first end p oint of the d up lic ate fib er link. End p oint-1’s d up lic ate along with End p oint-2’s d uplic ate make up the d up lic ate fib er link c alled the B-PNC link.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-6 Administer Fiber Links A d. The DS1CONV Board Type : field is display only and shows the type of DS1 Converter c irc uit p ac k in End p oint-1. The c irc uit p ac k type in End p oint-1 (A-PNC) and End p oint-1 (B-PNC) must matc h. e. In the Is one endpoint remoted via a DS1 Converter Complex? field , typ e y to sp ec ify that a DS1 Converter c omplex is used to remote 1 end point. If y is entered , ad minister the A-PNC DS1 Converter Board Loc ation on Pag e 1. The A-PNC DS1 Converter Board Type d isp lays. 7. On Pag e 2 of the form: a. Administer the A-PNC DS1 Converter (DS1CONV) Attributes. b . Enter the DS1 Converter Fac ilities information. In the Facility Installed? field , typ e y for all installed fac ilities (A, B, C, and D). c . In the Bit Rate : field, type 1.544 for T1 op eration or 2.048 for E1 op eration. NOTE: One b it rate ap p lies for all fac ilities within the same DS1 Converter c omplex. The Bit Rate: field d isp lays only und er Fac ility A. d . Enter the id le c od e in the Idle Code MSB (1) . . . . LSB (8): field . The default value is 11101000 . It is rec ommend ed that the d efault value b e used unless it b ec omes ab solutely nec essary to c hang e it. The “ MSB” means Most Sig nific ant Bit, the “ LSB” means Least Sig nific ant Bit. e. Enter the app rop riate d ata in the Line Coding: field . This d ata should matc h the line c od ing of the fac ility. For T1, examp le line coding is b8zs . For E1, example line c od ing is hdb3 . f. Sc roll to Pag e 3 and mod ify the field s as need ed for the B-PNC. NOTE: If this d ata is not c orrec t, wid eb and errors (suc h as multimed ia c all hand ling ) may oc c ur. 8. For T1 sites, refer to ‘‘T1 Installations Only’’ . For E1 sites, refer to ‘‘E1 Installations Only’’.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-7 Administer Fiber Links A T1 Installations Only 1. The Framing Mode: field is d isp lay only and shows the hard ware setting . 2. The DS1CONV-1 Line Compensation: and the DS1CONV-2 Line Compensation: field s are d isp lay only and show the hard ware setting . 3. In the Facility A Circuit ID: field , enter an op tional fac ility name that is uniq ue to eac h fac ility (up to 40 alp hanumeric c harac ters). Press En t e r. 4. A d isp lay similar to the following ap p ears after the fib er link ad ministration is c omp leted : RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED . E1 Installations Only 1. Type y or n in the CRC? field . The “ CRC” means Cyc lic Red und anc y Chec k. This is an error d etec tion alg orithm. 2. The Line Termination: field is d isp lay only. A 75 (75 Ohms) or 120 (120 Ohms) typ ic ally d isp lays. 3. In the Facility A Circuit ID: field , enter an op tional fac ility name that is uniq ue to eac h fac ility (up to 40 alp hanumeric c harac ters). Press En t e r. 4. A d isp lay similar to the following ap p ears after the fib er link ad ministration is c omp leted : RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED . All Installations 1. When the system reset is finished, type status port-network 2 and press En t e r. The Port Network Status sc reen ap p ears. Verify that PNC Ac tive is “ up ” and that the Servic e State is “ in.” 2. A Sp an LED, on the front of the DS1 Converter c irc uit p ac k, must b e on for eac h ac tive fac ility ad ministered . For examp le, if Fac ility A and Fac ility B are ad ministered , then the top 2 Sp an LEDs on the c irc uit p ac k must be on (yellow). The yellow LEDs are on only if no p rob lems were enc ountered d uring the ad ministration of hard ware. Sp an LEDs assoc iated with non-ad ministered fac ilities (C and D, in this example) should b e off. 3. Perform a test c all, if d esired .
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-8 Administer Fiber Links A Fiber Link Administration Form This form ad ministers fib er links, eac h of whic h is identified b y a fiber numb er. NOTE: Fib er link ad ministration only ap p lies to R5r and later c onfig urations. Port networks (PNs) are c onnec ted via d irec t fib er link c onnec tions or throug h a c enter stag e switc h (CSS) to p rovid e the interc onnec tion of p ort networks req uired for voic e/d ata information transfer. The CSS is c omp osed of switc h nod es that c an b e interc onnec ted in one or two levels to provid e Port Network Connec tivity (PNC). The CSS p rovides c irc uit-switc hed c onnec tivity for voic e and d ata c ommunic ations as well as pac ket-switc hed c onnec tivity. Fib er link ad ministration p ermits an ad ministration of translation d ata assoc iated with a switc h c onnec tion (suc h as op tic al fiber, metallic c able, or DS1CONV c irc uit packs and DS1 facility links between two endpoints). The two fiber endpoints can be: nAn exp ansion interfac e (EI) c irc uit p ac k nA switc h nod e interfac e (SNI) c irc uit p ac k NOTE: Only one ad ministrative terminal c an ad minister fiber links at a time; others c an d isp lay fib er link information. Administration commands Use the following c ommand s to ad minister the Fiber Link Ad ministration form. Action Object Qualifier 1 1. Brac kets [ ] ind ic ate the q ualifier is optional. Sing le q uotes (‘ ’) indic ate the text insid e the q uote must b e entered exactly as shown or an ab b reviated form of the word may be entered . ad d fib er-linklink numb er or [‘next’] c hang e fib er-link link numb er d isp lay fib er-link link numb er list fib er-link link numb er remove fib er-link link numb er
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-9 Administer Fiber Links A PNCs have three d ifferent reliab ility c onfig urations (one for eac h system reliability configuration) as follows: Simplex PNC For Simp lex PNC, PNC Dup lic ation is d isab led on the System-Parameters Customer-Op tions form and Op eration of Dup lic ation is d isab led on the Dup lic ation-Related System-Parameters form. Administration of PNC Duplication The PNC Dup lic ation feature is enab led on the System-Parameters Customer-Op tions form and Op eration of Dup lic ation is enab led on the Dup lic ation-Related System-Parameters form. When PNC Dup lic ation is enab led on the System-Parameters Customer-Op tions form, the following ad ministration forms c hang e: nCab inet form — Ad d itional field s ap p ear to allow ad ministration of switc h nod es to A-PNC and B-PNC sid es of the CSS. The B-PNC is the d up lic ated hard ware for the A-PNC. Either the A-PNC or the B-PNC c an p rovid e full c ustomized servic e. B-PNC c annot b e used in a simp lex PNC configuration. Pairing of switc h nodes is also defined here. nFi b e r L i n k f o r m — Ad d itional field s ap p ear to allow administration of fib er links on the B-PNC sid e of the CSS. If an end p oint on the A-PNC side is ad ministered as an SNI, its c orresp ond ing endp oint on the B-PNC sid e is d etermined (if switc h nodes are paired in the c ab inet form p rior to this ad ministration) and d isp layed . However, ad ministration of the d up lic ate B-PNC link is not enforc ed until dup lic ation is in full op eration. nDup lic ation-Related System-Parameters form — An ad d itional field ap p ears to enable op eration of PNC d uplic ation. System Configuration PNC Stand ard Reliability Simp lex Fibers Hig h Reliab ility Simp lex Fibers to Exp ansion Port Networks and Dup lic ated Fib ers b etween Proc essor Port N e t w o rk s (PPN ) a n d Sw it c h N o d e s Critical Reliab ility Dup licated Fib ers
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-10 Administer Fiber Links A Form instructions Page 1 of the form Screen 6-1. Fiber Link Administration form Basic Fiber Link Administration. The following fields appear: nFiber Link # — Disp lay-only field . From the c ommand line, enter a 1- to 3-d ig it numb er to uniq uely id entify a switc h c onnec tion in the system and its d up lic ate if ap prop riate. nBoard Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of an SNI or EI b oard that is the first endp oint of the fib er link. nBoard Type — Disp lay-only field showing the typ e of c irc uit p ac k in Endpoint-1. nBoard Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of an SNI or EI b oard that is the sec ond end point of the fib er link. nBoard Type — Disp lay-only field showing the typ e of c irc uit p ac k in Endpoint-2. nIs one endpoint remoted via a DS1 Converter Complex? — En t e r y to sp ec ify that a DS1 Converter c omp lex is used to remote one end p oint. If a y is entered , A-PNC DS1 Converter c irc uit p ac k Loc ation must b e ad ministered on Pag e 1. A-PNC DS1 Converter c irc uit pac k Typ e d isp lays. A-PNC DS1 Converter (DS1CONV) Attrib utes must b e ad ministered on Pag e 2 of this form. Page 1 of 1 FIBER LINK ADMINISTRATION Fiber Link #: 1 Is one endpoint remoted via a DS1 Converter Complex? ___ ENDPOINT-1 ENDPOINT-2 (A-PNC) (A-PNC) Board Location: _____ Board Location: _____ Board Type: xxx Board Type: xxx