    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							Fiber Link Administration 
    A-1 Administer Fiber Links 
    A
    DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    A
    Fiber Link Administration
    This ap p end ix desc rib es the step s req uired  to ad minister fib er links on G3rV4 
    and  later systems.
    Before starting  the ad ministration p roc ess, verify the following :
    1. Be sure all fiber op tic  transc eivers and  all fib er op tic  c ab les are c orrec tly 
    installed  on the DS1 and /or DS1 c onverter c irc uit pac ks. 
    2. Verify c onnec tions to the Lig htg uid e Interc onnec t Units (LIUs) or shelves, 
    to the fib er multip lexers, and  to the outsid e world . Refer to Ap p end ix A in 
    DEFINITY Enterp rise Communic ations Server Release 8 Installation and  
    Test for Multic arrier Cabinets
    .
    Administer Fiber Links
    Ad minister system fib er link c onfig urations to matc h the hardware installed  and  
    ac c ord ing  to the Fib er Op tic  Cab le Running  List. 
    NOTE:
    Fib er link ad ministration interac ts with or d ep end s up on other system 
    features that must b e ad ministered  b efore it. 
    Fiber link ad ministration c reates translation d ata by id entifying  the end p oint p airs 
    for eac h link. End p oints c an b e:
    nAn Exp ansion Interfac e (EI) c irc uit p ac k
    nA Switc h Nod e Interfac e (SNI) c irc uit p ac k 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-2 Administer Fiber Links 
    A
    Circuit Pack Form
    After installing  the eq uip ment (inc lud ing  c irc uit p ac ks), the c irc uit p ac ks must b e 
    ad ministered  
    before the fib er link is ad ministered . Refer to DEFINITY Enterp rise 
    Communic ations Server Release 8 Ad ministrator’s Guid e
     for more information.
    The following information d esc ribes general c irc uit pac k ad ministration 
    information:
    a. Use the Circ uit Pac ks form to ad minister c irc uit p ac ks to c arrier slots. 
    Install or ad minister the c irc uit p ac ks (or assig ned  using the Circ uit Pac ks 
    form) b efore ad ministering  voic e terminals, attend ant c onsoles, or trunks.
    b . Eac h p ag e of the form rep resents 1 c arrier in the c ab inet shown on the 
    c ommand  line. 
    c . Refer to 
    DEFINITY Communic ations System Generic  3 Planning  and 
    Config uration
     for more information about c irc uit pack administration and 
    port assignment records.
    d . For initial installation, assig n c irc uit p ac ks to slots using the hard ware 
    configuration layout record from the fac tory or Customer Services 
    Org anization. Do not arb itrarily assig n c irc uit p ac ks to slots.
    e. If the c arrier typ e ad ministered  on the Cab inet Ad ministration form d oes 
    not matc h the p hysic al hard ware, question marks (??) may d isp lay in the 
    Code fields.
    f. When a c irc uit p ac k in a slot d iffers from what has b een ad ministered on 
    the form, a “ #”  d isp lays b etween the “ Sfx”  and “ Name”  field s to ind ic ate a 
    conflict.
    g . For Release 8r, the numb er of slot fields d isp layed  represents 
    ad ministrab le slots for the g iven c arrier typ e.  
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-3 Administer Fiber Links 
    A
    Administer Fiber Links on Simplex Systems 
    Ad minister the TN570 Exp ansion Interfac e and  the TN574 or TN1654 DS1 
    Converter circuit packs. 
    1. Type change circuit packs
     and press 
    En te r. Sc roll throug h the p ag es on 
    the form until the c arrier c ontaining the new c irc uit p ac ks d isp lays on the 
    sc reen. 
    2. Enter the c irc uit p ac ks into the ap p rop riate slot loc ations on the form. 
    Press 
    En t e r when finished .
    3. Type list fiber
     and press 
    En te r. All ad ministered  fiber c onnec tions display. 
    4. If a p reviously used  fib er link is to b e reused , enter add fiber 
     
    and  p ress 
    En t e r. If this is a new fib er link, typ e add fiber next
     and press 
    En t e r. The Fib er Link Ad ministration sc reen ap p ears. Eac h fib er link is 
    id entified  b y a fib er numb er. 
    a. Type y
     or n
     in the field  Is one endpoint remoted via DS1 
    Converter complex?
     and press 
    En te r.
    b . Enter the loc ation of the TN570 and  the TN574 or TN1654 c irc uit 
    p ac ks for b oth ENDPOINT-1 and  ENDPOINT-2.
    c . Sc roll to p ag e 2 of the form. Enter y
     as ap plic ab le, in eac h 
    Facility Installed?
     field  (A, B, C, and  D). 
    d . In the Bit Rate:
     field , typ e either 1.544
     (T1) or 2.048
     (E1). 
    e. Enter the id le c od e in the Idle Code MSB (1) . . . . LSB 
    (8):
     field . The default value is 11101000
    . It is rec ommend ed  that 
    the d efault value b e used  unless it b ec omes ab solutely nec essary 
    to c hang e it. The “ MSB”  means Most Sig nific ant Bit, the “ LSB”  
    means Least Sig nific ant Bit. 
    f. In the Line Coding: 
    field, enter the line coding information. This 
    information should  matc h the line c od ing  of the fac ility. For T1, 
    examp le line c od ing  is b8zs
    . For E1, examp le line c od ing  is hdb3
    . 
    NOTE:
    If this d ata is not c orrec t, wid eb and  errors (multimed ia c all 
    hand ling ) may oc c ur. 
    5. For T1 sites, refer to ‘‘T1 Installations Only’’
    . For E1 sites, refer to ‘‘E1 
    Installations Only’’. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-4 Administer Fiber Links 
    A
    T1 Installations Only
    1. The Framing Mode:
     field  is d isp lay only and  shows the hard ware setting .
    2. The DS1CONV-1 Line Compensation:
     and the DS1CONV-2 Line 
    Compensation:
     field s are d isp lay only and  show the hard ware setting . 
    3. In the Facility A Circuit ID:
     field , enter an op tional fac ility name 
    that is uniq ue to eac h fac ility (up  to 40 alp hanumeric  c harac ters). Press 
    En t e r.
    4. A d isp lay similar to the following ap p ears after the fib er link ad ministration 
    is c omp leted : 
    RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED
    .
    E1 Installations Only
    1. Type y
     or n
     in the CRC?
     field . The “ CRC”  means Cyc lic  Red und anc y 
    Chec k. This is an error d etec tion alg orithm.
    2. The Line Termination:
     field  is d isp lay only. A 75 (75 Ohms) or 120 
    (120 Ohms) typ ic ally d isp lays.
    3. In the Facility A Circuit ID:
     field , enter an op tional fac ility name 
    that is uniq ue to eac h fac ility (up  to 40 alp hanumeric  c harac ters). Press 
    En t e r.
    4. A d isp lay similar to the following ap p ears after the fib er link ad ministration 
    is c omp leted : 
    RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED
    .
    All Installations
    1. When the system reset is finished, type status port-network 2
     and press 
    En t e r. The Port Network Status sc reen ap p ears. Verify that PNC Ac tive is 
    “ up ”  and that the Servic e State is “ in.”  
    2. A Sp an LED, on the front of the DS1 Converter c irc uit p ac k, must b e on for 
    eac h ac tive fac ility ad ministered . For examp le, if Fac ility A and  Fac ility B 
    are ad ministered , then the top  2 Sp an LEDs on the c irc uit p ac k must be on 
    (yellow). The yellow LEDs are on only if no p rob lems were enc ountered  
    d uring the ad ministration of hard ware. Sp an LEDs assoc iated  with 
    non-ad ministered  fac ilities (C and  D, in this example) should  b e off.
    3. Perform a test c all, if d esired . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-5 Administer Fiber Links 
    A
    Administer Fiber Links on Duplex Systems 
    All non-d up lic ated  Switc h Nod e Interfac es to Switc h Nod e Interfac e fiber links 
    are automatic ally dup lic ated . When PNC Dup lic ation is enab led  on the 
    System-Parameters Customer-Op tions form, the following  ad ministration forms 
    change:
    nCab inet Form — Ad d itional field s ap pear to allow ad ministration of switc h 
    nod es to A-PNC and  B-PNC sid es of the CSS. The B-PNC is the 
    d up lic ated  hard ware for the A-PNC. Either the A-PNC or the B-PNC c an 
    p rovid e full c ustomized  servic e. B-PNC c annot b e used  in a simp lex PNC 
    configuration. Pairing of switc h nodes is also defined here.
    nFiber Link Ad ministration Form — Ad d itional field s ap p ear to allow 
    ad ministration of fib er links on the B-PNC sid e of the CSS. If an end p oint 
    on the A-PNC sid e is ad ministered  as an SNI, its c orresp ond ing  end point 
    on the B-PNC sid e is d etermined  (if switc h nod es are p aired  in the c ab inet 
    form p rior to this ad ministration) and  d isp layed . However, ad ministration 
    of the d uplic ate B-PNC link is not enforc ed  until d up lic ation is in full 
    op eration.
    nDup lic ation-Related  System-Parameters Form — An ad d itional field  
    ap p ears to enable op eration of PNC d uplic ation.
    1. Type change system-parameters customer-options
     and press 
    En te r. On 
    Pag e 2 of the form, set the PNC Duplication?
     field  to y
    . Press 
    En t e r.
    2. Type change system-parameters duplication
     and press 
    En t e r. Chang e 
    the Enable operation of PNC duplication?
     field  to y
    . Press 
    En te r. 
    3. Type status pnc
     and  p ress 
    En t e r. Verify the Duplicated ?
     field  is yes
    .
    4. Type list fiber
     and press 
    En te r. All ad ministered  fiber c onnec tions display. 
    5. If a p reviously used  fib er link is to b e reused , typ e add fiber 
     
    and  p ress 
    En t e r. If this is a new fib er link, typ e add fiber next
     and press 
    En t e r. 
    6. The Fib er Link Ad ministration form app ears. On Pag e 1 of the form:
    a. Enter the Board Location: 
    for Endpoint-1 and Endpoint-2. This 
    is the c ab inet, c arrier, and  slot that id entifies the p hysic al loc ation 
    of an SNI or EI c irc uit p ac k that is the first end p oint of the fib er link. 
    Rep eat for the remaining end p oints.
    b. The Board Type
     field  is d isp lay only and  shows the typ e of c irc uit 
    pack in Endpoint-1.
    c . In the DS1CONV Board Location
    : field, enter the c abinet, c arrier, 
    and  slot that id entifies the p hysic al loc ation of DS1 Converter c irc uit 
    p ac k in the first end p oint of the d up lic ate fib er link. End p oint-1’s 
    d up lic ate along with End p oint-2’s d uplic ate make up  the d up lic ate 
    fib er link c alled the B-PNC link. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-6 Administer Fiber Links 
    A
    d. The DS1CONV Board Type
    : field  is display only and shows the 
    type of DS1 Converter c irc uit p ac k in End p oint-1. The c irc uit p ac k 
    type in End p oint-1 (A-PNC) and  End p oint-1 (B-PNC) must matc h.
    e. In the Is one endpoint remoted via a DS1 Converter 
    Complex?
     field , typ e y
     to sp ec ify that a DS1 Converter c omplex is 
    used  to remote 1 end point. If y 
    is entered , ad minister the A-PNC 
    DS1 Converter Board  Loc ation on Pag e 1. The A-PNC DS1 
    Converter Board Type d isp lays.
    7. On Pag e 2 of the form:
    a. Administer the A-PNC DS1 Converter (DS1CONV) Attributes.
    b . Enter the DS1 Converter Fac ilities information. In the Facility 
    Installed?
     field , typ e y
     for all installed  fac ilities (A, B, C, and D).
    c . In the Bit Rate
    : field, type 1.544
     for T1 op eration or 2.048
     for E1 
    op eration. 
    NOTE:
    One b it rate ap p lies for all fac ilities within the same DS1 
    Converter c omplex. The Bit Rate:
     field  d isp lays only und er 
    Fac ility A.
    d . Enter the id le c od e in the Idle Code MSB (1) . . . . LSB 
    (8):
     field . The default value is 11101000
    . It is rec ommend ed  that 
    the d efault value b e used  unless it b ec omes ab solutely nec essary 
    to c hang e it. The “ MSB”  means Most Sig nific ant Bit, the “ LSB”  
    means Least Sig nific ant Bit. 
    e. Enter the app rop riate d ata in the Line Coding: 
    field . This d ata 
    should  matc h the line c od ing of the fac ility. For T1, examp le line 
    coding is b8zs
    . For E1, example line c od ing  is hdb3
    . 
    f. Sc roll to Pag e 3 and  mod ify the field s as need ed  for the B-PNC.
    NOTE:
    If this d ata is not c orrec t, wid eb and  errors (suc h as 
    multimed ia c all hand ling ) may oc c ur. 
    8. For T1 sites, refer to ‘‘T1 Installations Only’’
    . For E1 sites, refer to ‘‘E1 
    Installations Only’’. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-7 Administer Fiber Links 
    A
    T1 Installations Only
    1. The Framing Mode:
     field  is d isp lay only and  shows the hard ware setting .
    2. The DS1CONV-1 Line Compensation:
     and the DS1CONV-2 Line 
    Compensation:
     field s are d isp lay only and  show the hard ware setting . 
    3. In the Facility A Circuit ID:
     field , enter an op tional fac ility name 
    that is uniq ue to eac h fac ility (up  to 40 alp hanumeric  c harac ters). Press 
    En t e r.
    4. A d isp lay similar to the following ap p ears after the fib er link ad ministration 
    is c omp leted : 
    RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED
    .
    E1 Installations Only
    1. Type y
     or n
     in the CRC?
     field . The “ CRC”  means Cyc lic  Red und anc y 
    Chec k. This is an error d etec tion alg orithm.
    2. The Line Termination:
     field  is d isp lay only. A 75 (75 Ohms) or 120 
    (120 Ohms) typ ic ally d isp lays.
    3. In the Facility A Circuit ID:
     field , enter an op tional fac ility name 
    that is uniq ue to eac h fac ility (up  to 40 alp hanumeric  c harac ters). Press 
    En t e r.
    4. A d isp lay similar to the following ap p ears after the fib er link ad ministration 
    is c omp leted : 
    RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED
    .
    All Installations
    1. When the system reset is finished, type status port-network 2
     and press 
    En t e r. The Port Network Status sc reen ap p ears. Verify that PNC Ac tive is 
    “ up ”  and that the Servic e State is “ in.”  
    2. A Sp an LED, on the front of the DS1 Converter c irc uit p ac k, must b e on for 
    eac h ac tive fac ility ad ministered . For examp le, if Fac ility A and  Fac ility B 
    are ad ministered , then the top  2 Sp an LEDs on the c irc uit p ac k must be on 
    (yellow). The yellow LEDs are on only if no p rob lems were enc ountered  
    d uring the ad ministration of hard ware. Sp an LEDs assoc iated  with 
    non-ad ministered  fac ilities (C and  D, in this example) should  b e off.
    3. Perform a test c all, if d esired . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-8 Administer Fiber Links 
    A
    Fiber Link Administration Form
    This form ad ministers fib er links, eac h of whic h is identified  b y a fiber numb er.
    NOTE:
    Fib er link ad ministration only ap p lies to R5r and  later c onfig urations.
    Port networks (PNs) are c onnec ted via d irec t fib er link c onnec tions or throug h a 
    c enter stag e switc h (CSS) to p rovid e the interc onnec tion of p ort networks 
    req uired for voic e/d ata information transfer. The CSS is c omp osed  of switc h 
    nod es that c an b e interc onnec ted  in one or two levels to provid e Port Network 
    Connec tivity (PNC). The CSS p rovides c irc uit-switc hed  c onnec tivity for voic e and  
    d ata c ommunic ations as well as pac ket-switc hed  c onnec tivity. Fib er link 
    ad ministration p ermits an ad ministration of translation d ata assoc iated  with a 
    switc h c onnec tion (suc h as op tic al fiber, metallic  c able, or DS1CONV c irc uit 
    packs and DS1 facility links between two endpoints). The two fiber endpoints can 
    be:
    nAn exp ansion interfac e (EI) c irc uit p ac k
    nA switc h nod e interfac e (SNI) c irc uit p ac k
    NOTE:
    Only one ad ministrative terminal c an ad minister fiber links at a time; 
    others c an d isp lay fib er link information.
    Administration commands
    Use the following  c ommand s to ad minister the Fiber Link Ad ministration form.
    Action Object Qualifier
    1
    1. Brac kets [  ]  ind ic ate the q ualifier is optional. 
    Sing le q uotes (‘ ’) indic ate the text insid e the q uote 
    must b e entered  exactly as shown or an 
    ab b reviated form of the word  may be entered .
    ad d fib er-linklink numb er or [‘next’]
    c hang e fib er-link link numb er
    d isp lay fib er-link link numb er
    list fib er-link link numb er
    remove fib er-link link numb er 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-9 Administer Fiber Links 
    A
    PNCs have three d ifferent reliab ility c onfig urations (one for eac h system reliability 
    configuration) as follows:
    Simplex PNC
    For Simp lex PNC, PNC Dup lic ation is d isab led  on the System-Parameters 
    Customer-Op tions form and  Op eration of Dup lic ation is d isab led  on the 
    Dup lic ation-Related  System-Parameters form.
    Administration of PNC Duplication
    The PNC Dup lic ation feature is enab led  on the System-Parameters 
    Customer-Op tions form and  Op eration of Dup lic ation is enab led  on the 
    Dup lic ation-Related  System-Parameters form. When PNC Dup lic ation is enab led  
    on the System-Parameters Customer-Op tions form, the following  ad ministration 
    forms c hang e:
    nCab inet form — Ad d itional field s ap p ear to allow ad ministration of switc h 
    nod es to A-PNC and  B-PNC sid es of the CSS. The B-PNC is the 
    d up lic ated  hard ware for the A-PNC. Either the A-PNC or the B-PNC c an 
    p rovid e full c ustomized  servic e. B-PNC c annot b e used  in a simp lex PNC 
    configuration. Pairing of switc h nodes is also defined here.
    nFi b e r  L i n k  f o r m  — Ad d itional field s ap p ear to allow administration of fib er 
    links on the B-PNC sid e of the CSS. If an end p oint on the A-PNC side is 
    ad ministered  as an SNI, its c orresp ond ing  endp oint on the B-PNC sid e is 
    d etermined  (if switc h nodes are paired  in the c ab inet form p rior to this 
    ad ministration) and  d isp layed . However, ad ministration of the d up lic ate 
    B-PNC link is not enforc ed  until dup lic ation is in full op eration.
    nDup lic ation-Related  System-Parameters form — An ad d itional field  
    ap p ears to enable op eration of PNC d uplic ation. System Configuration PNC
    Stand ard  Reliability Simp lex Fibers
    Hig h Reliab ility Simp lex Fibers to Exp ansion Port Networks and
    Dup lic ated  Fib ers b etween Proc essor Port 
    N e t w o rk s  (PPN )  a n d  Sw it c h  N o d e s
    Critical Reliab ility Dup licated  Fib ers 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-10 Administer Fiber Links 
    A
    Form instructions
    Page 1 of the form
    Screen 6-1. Fiber Link Administration form
    Basic Fiber Link Administration. 
    The following fields appear:
    nFiber Link #
     — Disp lay-only field . From the c ommand  line, enter a 1- to 
    3-d ig it numb er to uniq uely id entify a switc h c onnec tion in the system and 
    its d up lic ate if ap prop riate.
    nBoard Location
     — Enter the c ab inet, c arrier, and  slot that id entifies the 
    p hysic al loc ation of an SNI or EI b oard  that is the first endp oint of the fib er 
    link.
    nBoard Type
     — Disp lay-only field  showing  the typ e of c irc uit p ac k in 
    Endpoint-1.
    nBoard Location
     — Enter the c ab inet, c arrier, and  slot that id entifies the 
    p hysic al loc ation of an SNI or EI b oard  that is the sec ond  end point of the 
    fib er link.
    nBoard Type
     — Disp lay-only field  showing  the typ e of c irc uit p ac k in 
    Endpoint-2.
    nIs one endpoint remoted via a DS1 Converter Complex?
     — En t e r  y
     to 
    sp ec ify that a DS1 Converter c omp lex is used  to remote one end p oint. If a 
    y
     is entered , A-PNC DS1 Converter c irc uit p ac k Loc ation must b e 
    ad ministered  on Pag e 1. A-PNC DS1 Converter c irc uit pac k Typ e d isp lays. 
    A-PNC DS1 Converter (DS1CONV) Attrib utes must b e ad ministered  on 
    Pag e 2 of this form.
                                                                      Page 1 of 1
                               FIBER LINK ADMINISTRATION         
    Fiber Link #: 1
    Is one endpoint remoted via a DS1 Converter Complex? ___
    ENDPOINT-1                                ENDPOINT-2
                  (A-PNC)                                   (A-PNC)
               Board Location: _____ Board Location: _____
                   Board Type: xxx Board Type: xxx 
    						