    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-29 Install a New EPN Cabinet in an Existing System 
    6
    1. At the rear of the Port Carrier in p osition C in Cab inet 1, install a 9823A 
    lig htwave transc eiver onto Slot 2 (1C02). See Figure 6-16
    .
    2. Connec t a 20-foot fib er op tic  c ab le to the TX and  RX c onnec tors on the 
    transc eiver. Lab el the c ab le to make the c onnec tions to Cab inet 4 easier. 
    3. Route the fib er c ab le to the Port Carrier in position E in Cab inet 4. 
    4. At the rear of the Port Carrier in p osition E in Cab inet 4, install a 9823A 
    lig htwave transc eiver onto Slot 2 (4E02).
    5. Connec t the 20-foot fib er op tic  c ab le from the Port Carrier in Cabinet 1 to 
    the TX and RX c onnec tors on the transc eiver on the Port Carrier in Cab inet 
    4. Be sure the c ab le c onnec ted  to the TX c onnec tor on 1 transc eiver is 
    c onnec ted  to the RX c onnec tor on the other transc eiver and  vic e versa.
    6. At the rear of the Expansion Control Carrier in Cabinet 2, install a 9823A 
    lig htwave transc eiver onto Slot 1 (2A01).
    7. Connec t a 20-foot fib er op tic  c ab le to the TX and  RX c onnec tors on the 
    transc eiver. Be sure to lab el the c able.
    8. At the rear of the Switc h Nod e Carrier in p osition E in Cab inet 4, install a 
    9823A lig htwave transc eiver onto Slot 20 (4E20).
    9. Connec t the 20-foot fib er op tic  c ab le from Cab inet 2 to the TX and  RX 
    c onnec tors on the transc eiver on the Switc h Nod e Carrier in Cab inet 4. Be 
    sure the c ab le c onnec ted  to the TX c onnec tor on 1 transc eiver is 
    c onnec ted  to the RX c onnec tor on the other transc eiver and  vic e versa.
    10. At the rear of the Port Carrier in p osition D in Cab inet 1, install a 9823A 
    lig htwave transc eiver onto Slot 2 (1D02).
    11. Connec t a 20-foot fib er op tic  c ab le to the TX and  RX c onnec tors on the 
    transc eiver. Be sure to lab el the c able.
    12. Route the fib er c ab le to Switc h Nod e Carrier in p osition E in Cab inet 4.
    13. At the rear of the Switc h Nod e Carrier in p osition E in Cab inet 4, install a 
    9823A lig htwave transc eiver onto Slot 3 (4E03).
    14. Connec t the 20-foot fib er op tic  c ab le from Cab inet 1 to the TX and  RX 
    c onnec tors on the transc eiver on the Switc h Nod e Carrier in Cab inet 4. Be 
    sure the c ab le c onnec ted  to the TX c onnec tor on 1 transc eiver is 
    c onnec ted  to the RX c onnec tor on the other transc eiver and  vic e versa.
    15. Connec t an H600-278 Metallic  Cab le from Slot 1 in the Exp ansion Control 
    Carrier in Cab inet 4 (4A01) to Slot 19 on the Switc h Nod e Carrier in 
    p osition E in Cab inet 4 (4E19). 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-30 Install a New EPN Cabinet in an Existing System 
    6
    Figure 6-16. Switch-Connected Release 8r with SNC in EPN Figure Notes:
    1. Cab inet 1 (PPN)
    2. Cab inet 2, 3, and  5 through 16 (MCC or SCC EPNs)3. Cab inet 4 (MCC EPN 
    with One Switc h Nod e) 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-31 Install a New EPN Cabinet in an Existing System 
    6
    Switch-Connect New EPN to Existing PPN and
    EPN (Critical Reliability)
    For the following  c onnec tion examp le, the PPN c ab inet is c alled  Cab inet 1, the 
    first EPN c ab inet is c alled  Cab inet 2, and  the EPN c ab inet c ontaining  the Switc h 
    Nod e Carrier is c alled  Cab inet 4. 
    NOTE:
    For the following  examp le, ad d  links to PNs in alternating  ord er, for 
    examp le: 20 and  2, 19 and  3, 18 and  4, and so forth.
    1. At the rear of the Port Carrier in p osition C in Cab inet 1, install a lig htwave 
    transc eiver onto Slot 2 (1C02). See Figure 6-17
    .
    2. Connec t a 20-foot (6 m) fib er op tic  c ab le to the TX and  RX c onnec tors on 
    the transc eiver. Label the c ab le to make the c onnec tions to Cab inet 4 
    easier. 
    3. Route the fib er c able to the Switc h Nod e Carrier in p osition D in Cab inet 4. 
    4. At the rear of the Switc h Nod e Carrier in p osition D in Cab inet 4, install a 
    lig htwave transc eiver onto Slot 2 (4E02).
    5. Connec t the 20-foot (6 m) fib er op tic  c ab le from the Port Carrier in Cab inet 
    1 to the TX and  RX c onnec tors on the transc eiver on the Switc h Nod e 
    Carrier in Cab inet 4. Be sure the c ab le c onnec ted  to the TX c onnec tor on 
    1 transc eiver is c onnec ted  to the RX c onnec tor on the other transc eiver 
    and  vic e versa.
    6. At the rear of the Port Carrier in p osition D in Cab inet 1, install a lig htwave 
    transc eiver onto Slot 2 (1D02).
    7. Connec t a 20-foot (6 m) fib er op tic  c ab le to the TX and  RX c onnec tors on 
    the transc eiver. Be sure to lab el the c ab le.
    8. At the rear of the Switc h Nod e Carrier in p osition D in Cab inet 4, install a 
    lig htwave transc eiver onto Slot 2 (4D02).
    9. Connec t the 20-foot (6 m) fib er op tic  c ab le from the Port Carrier in p osition 
    D in Cabinet 1 to the TX and  RX c onnec tors on the transc eiver. Be sure to 
    lab el the c ab le.
    10. At the rear of the Port Carrier in p osition B in Cab inet 2, install a 9823A 
    lig htwave transc eiver onto Slot 2 (2B02).
    11. Connec t a 20-foot (6 m) fib er op tic  c ab le to the TX and  RX c onnec tors on 
    the transc eiver. Be sure to lab el the c ab le.
    12. At the rear of the Switc h Nod e Carrier in p osition D in Cab inet 4, install a 
    lig htwave transc eiver onto Slot 20 (4D20).
    13. Connec t the 20-foot (6 m) fib er op tic  c ab le from the transc eiver on the 
    Switc h Nod e Carrier p osition D in Cab inet 4. Be sure the c ab le c onnec ted  
    to the TX c onnec tor on 1 transc eiver is c onnec ted  to the RX c onnec tor on 
    the other transc eiver and  vic e versa. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-32 Install a New EPN Cabinet in an Existing System 
    6
    14. At the rear of the Exp ansion Control Carrier in p osition A in Cab inet 2, 
    install a lig htwave transc eiver onto Slot 1 (2A01).
    15. Connec t a 20-foot (6 m) fib er op tic  c ab le to the TX and  RX c onnec tors on 
    the transc eiver. Be sure to lab el the c ab le.
    16. At the rear of the Switc h Nod e Carrier in p osition E in Cab inet 4, install a 
    lig htwave transc eiver onto Slot 20 (4E20).
    17. Connec t the 20-foot (6 m) fib er op tic  c ab le from the transc eiver on the 
    Switc h Nod e Carrier p osition E in Cab inet 4. Be sure the c ab le c onnec ted  
    to the TX c onnec tor on 1 transc eiver is c onnec ted  to the RX c onnec tor on 
    the other transc eiver and  vic e versa.
    18. At the rear of the Port Carrier in p osition B in Cab inet 3, install a lig htwave 
    transc eiver onto Slot 2 (3A01).
    19. Connec t a 20-foot (6 m) fib er op tic  c ab le to the TX and  RX c onnec tors on 
    the transc eiver. Be sure to lab el the c ab le.
    20. At the rear of the Switc h Nod e Carrier in p osition E in Cab inet 4, install a 
    lig htwave transc eiver onto Slot 3 (4E03).
    21. Connec t the 20-foot (6 m) fib er op tic  c ab le from the transc eiver on the 
    Switc h Nod e Carrier p osition E in Cab inet 4. Be sure the c ab le c onnec ted  
    to the TX c onnec tor on 1 transc eiver is c onnec ted  to the RX c onnec tor on 
    the other transc eiver and  vic e versa.
    22. At the rear of the Exp ansion Control Carrier in p osition A in Cab inet 3, 
    install a lig htwave transc eiver onto Slot 2 (3B02).
    23. Connec t a 20-foot (6 m) fib er op tic  c ab le to the TX and  RX c onnec tors on 
    the transc eiver. Be sure to lab el the c ab le.
    24. At the rear of the Switc h Nod e Carrier in p osition D in Cab inet 4, install a 
    lig htwave transc eiver onto Slot 3 (4D03).
    25. Connec t the 20-foot (6 m) fib er op tic  c ab le from the transc eiver on the 
    Switc h Nod e Carrier p osition D in Cab inet 4. Be sure the c ab le c onnec ted  
    to the TX c onnec tor on 1 transc eiver is c onnec ted  to the RX c onnec tor on 
    the other transc eiver and  vic e versa.
    NOTE:
    Continue c onnec ting  the fib er c ab les in this manner until all fib er 
    c onnec tions are mad e. Be sure to ad d  links to PNs in alternating  
    ord er (20 and  2, 19 and  3, 18 and  4, and  so forth).
    26. Connec t an H600-278 Metallic  Cab le from Slot 1 in the Exp ansion Control 
    Carrier in Cab inet 4 (4A01) to Slot 19 on the Switc h Nod e Carrier in 
    p osition E in Cab inet 4 (4E19). 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-33 Install a New EPN Cabinet in an Existing System 
    6
    Figure 6-17. Switch-Connected Release 8r with SNC in EPN
    27. Connec t an H600-278 Metallic  Cab le from Slot 2 in the Port Carrier in 
    p osition B in Cab inet 4 (4B02) to Slot 19 on the Switc h Node Carrier in 
    p osition D in Cab inet 4 (4D19).
    NOTE:
    Both fib ers from eac h PN must c onnec t to the same slot numb er in 
    eac h Switc h Nod e Carrier. For examp le: if Slot 3A01 of EPN 3 
    c onnec ts to Switc h Nod e Carrier Slot 4E19, then Slot 3B02 of EPN 3 
    must c onnec t to Switc h Nod e Carrier Slot 4D19.
    28. Proc eed  to Appendix A, ‘‘Fiber Link Administration’’
     to add  the new fib er 
    links. Figure Notes:
    1. Cab inet 1 (PPN)
    2. Cabinet 4 (MCC EPN with One 
    Duplex Switc h Nod e)3.
    Cab inet 2, 3, and  5 throug h 16 (MCC or SCC 
    EPN s) 
    H600-278 Metallic  Cab le 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-34 Remove an EPN Cabinet from an Existing System 
    6
    Remove an EPN Cabinet from an 
    Existing System
    All Systems
    Before starting  the EPN removal p roc ess, p erform the following :
    NOTE:
    If you d o not d isab le the TTI, the translations c an be c orrup ted .
    1. Type change system-parameters features
     and  p ress 
    En te r . Use sc reen 2 
    to d isab le Terminal Translation Initialization (TTI) b y c hanging  the setting  to 
    n
    .
    2. Unadminister 
    all of the affec ted  trunks, attend ant c onsoles, voic e 
    terminals, and  d ata modules assoc iated  with the p ort c irc uit p ac ks in the 
    EPN c ab inet b eing  removed . These p ort-related  translations must b e 
    unad ministered  b efore removing  any hard ware. Refer to 
    DEFINITY 
    Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e
     for 
    more information.
    Unadminister Fiber Links (Simplex Systems)
    The fib er links routing  to and  from the EPN c ab inet b eing  removed  must be 
    unadministered before removing 
    any hard ware from the c ab inet. 
    !CAUTION:
    Failure to unad minister fib er links b efore removing  hard ware c auses 
    unnec essary alarm rep orts to INADS and  c auses errors that are very 
    d iffic ult to c lear.
    The fib er links are ad ministered  to matc h hard ware and  the Fib er Op tic  Cab le 
    Running  List. Fib er link ad ministration c reates translation d ata b y id entifying  the 
    end p oint pairs for eac h link. To p rop erly unad minister the fib er links, this 
    translation d ata must b e removed .
    1. Unadminister the TN570 Exp ansion Interfac e and the TN574 or TN1654 
    DS1 Converter c irc uit p ac ks. Typ e change circuit-packs
     and press 
    En t e r. 
    Sc roll throug h the sc reens until the c arrier c ontaining  the c irc uit p ac ks is 
    d isp layed . Remove the TN570 and  the TN574 or TN1654 c irc uit p ac ks 
    from the slot loc ations on the sc reen. Press 
    En te r when finished .
    2. Type list fiber
     and press 
    En te r. All ad ministered  fiber c onnec tions are 
    d isp layed . Make note of whic h fib er links are to b e removed . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-35 Remove an EPN Cabinet from an Existing System 
    6
    3. Type change fiber link
     and press En t e r. The Fib er Link Ad ministration 
    sc reen ap p ears. Use this sc reen to unad minister fib er links, eac h of whic h 
    is identified  b y a fiber numb er. 
    a. The Is one endpoint remoted via DS1 Converter 
    complex?
     field must remain administered.
    b . Remove the loc ation of the TN570 and  the TN574 or TN1654 c irc uit 
    p ac k for b oth ENDPOINT-1 and ENDPOINT-2.
    4. Sc roll to sc reen 2.
    a. Type no
    , as ap plic ab le, in eac h Facility Installed?
     field  (A, 
    B, C, and  D). 
    b. The Bit Rate:
     field  must remain ad ministered  if other fib er 
    c onnec tions assoc iated  with the fac ility will remain. 
    c . The id le c od e in the Idle Code MSB (1) . . . . LSB (8):
     
    field must remain administered. 
    d. The Line Coding: 
    field  must remain ad ministered . 
    5. For a T1 site, p roc eed  to ‘‘T1 Installations Only’’
    . For an E1 site, proc eed  to 
    ‘‘E1 Installations Only’’
    .
    T1 Installations Only
    1. The Framing Mode:
     field  is d isp lay only.
    2. The DS1CONV-1 Line Compensation:
     and the DS1CONV-2 Line 
    Compensation:
     fields are display only. 
    3. Remove the Facility Circuit ID:
     from the fac ilities b eing  
    unad ministered , if used . Press 
    En t e r.
    4. A d isplay similar to the following  ap p ears after the p roc ed ure is 
    completed: 
    RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED
    .
    E1 Installations Only
    1. The CRC?
     field must remain administered.
    2. The Line Termination:
     field is display only.
    3. Remove the Facility Circuit ID
     information from the fac ilities b eing  
    unad ministered , if used . Press 
    En t e r.
    4. A d isplay similar to the following  ap p ears after the p roc ed ure is 
    completed: 
    RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED
    . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-36 Remove an EPN Cabinet from an Existing System 
    6
    All Installations
    1. When the system reset is finished, type status port-network 2
     and press 
    En t e r. The Port Network Status sc reen ap p ears. Verify that PNC Ac tive is 
    “ up ”  and that the Servic e State is “ in.”  
    2. A Span LED, on the front of the DS1 Converter circuit pack, must be off for 
    eac h inac tive fac ility administered . For examp le, if Fac ility A and  Fac ility B 
    are unad ministered , then the top  2 Sp an LEDs on the c irc uit p ac k must b e 
    off. If the yellow LEDs are on, then p rob lems were enc ountered d uring the 
    unad ministration of hard ware. Sp an LEDs assoc iated  with ad ministered  
    fac ilities (C and  D, in this examp le) should  b e on.
    Removing the Hardware
    1. Be sure that you have unad ministered  the trunks, attend ant c onsoles, 
    voic e terminals, and  d ata mod ules assoc iated  with the p ort c irc uit pac ks 
    in the EPN c ab inet. 
    2. Remove the fib er op tic  c ab les from the fib er transc eivers at b oth end s of 
    the fib er sp an. Carefully c oil the fib er op tic  c ables. Avoid  b end ing  c ab les 
    to a rad ius smaller than 1.5 inc hes (3.8 c m).
    3. Remove the fib er transc eivers from the DS1 and /or DS1 c onverter c irc uit 
    p ac ks at b oth end s of eac h fib er sp an.
    4. Remove the 25-p air c ab les from the c onnec tor p anel on eac h c arrier of 
    the EPN. 
    5. Type remove cabinet 
      and  p ress 
    En t e r. This removes the EPN 
    c ab inet ad ministration.
    6. Remove the p ower c ord s from the p ower units in eac h c arrier in the EPN 
    and  remove the AC power c ord  or DC p ower wires.
    7. Chec k the ground ing  sc heme for the c ab inets. Perform the following :
    a. If any c ab inet ground  wires c onnec t in 
    series b etween the EPN 
    c ab inet and  any other c ab inet, remove the wires from the EPN 
    c ab inet and  c onnec t them to the next c abinet in the g round  p lane. 
    !CAUTION:
    Never leave c ab inets ungrounded . When a ground  wire is 
    removed  from a series-c onnec ted  c abinet, the g round  p lane 
    b ec omes op en with respec t to all sub seq uent c ab inets.
    b . If any c abinet g round  wires c onnec t in parallel to other c ab inets, or 
    c onnec t d irec tly to the AC p ower panel g round  or other ap proved  
    g round , remove the wire from eac h end  of the g round sp an.
    8. Carefully remove the EPN c ab inet. The c ab inet may weig h as muc h as 
    800 p ound s. Use c aution. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-37 Remove an EPN Cabinet from an Existing System 
    6
    9. Type change system-parameters features
     and  p ress En t e r. Use this 
    sc reen to c hang e the TTI field b ac k to its p revious setting  b efore the 
    up g rad e.
    10. When finished , p lac e d ust c overs over all exp osed  fib er c oup ling s that 
    remain after the fib er op tic  c ab les are removed .
    11. If any fib er op tic  c ab les were removed  from Lightg uide Interc onnec t Units 
    (LIUs) or Fib er Patc h Panels, remove the assoc iated  c able lab eling . This 
    will prevent c onfusion if existing  fib er is later moved.
    12. Return all unused equipment (not owned by the customer) to Lucent 
    Tec hnolog ies ac c ord ing  to the req uirements outlined in:
    BCS/Material Log istic s, MSL/Attend ed  Stoc king  Loc ations
    Method s and Proc ed ures for Basic  Material Returns
    13. If any messag e waiting  lamp s are on, skip  to ‘‘Troubleshooting’’ on page 
    6-40.
    Unadminister Fiber Links (Duplex Systems)
    The fib er links routing  to and  from the EPN c ab inet b eing  removed  must be 
    unadministered before removing 
    any hard ware from the c ab inet. 
    !CAUTION:
    Failure to unad minister fib er links b efore removing  hard ware c auses 
    unnec essary alarm rep orts to INADS and  c auses errors that are very 
    d iffic ult to c lear.
    The fib er links are ad ministered  to matc h hard ware and  the Fib er Op tic  Cab le 
    Running  List. Fib er link ad ministration c reates translation d ata b y id entifying  the 
    end p oint pairs for eac h link. To p rop erly unad minister the fib er links, this 
    translation d ata must b e removed .
    1. Type list fiber
     and press 
    En te r. All ad ministered  fiber c onnec tions are 
    d isp layed . Make note of the fib er links to b e removed . 
    2. Type change fiber link
     and press 
    En t e r. The Fib er Link Ad ministration 
    sc reen ap p ears. On sc reen 1:
    a. Remove the Board Location: 
    information for ENDPOINT-1 and  
    ENDPOINT-2. This is the c ab inet, c arrier, and  slot that id entifies the 
    p hysic al loc ation of an SNI or EI c irc uit p ac k that is the first 
    end p oint of the fib er link. Rep eat for the remaining  end points.
    b. The Board Type
     field  is display only. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-38 Remove an EPN Cabinet from an Existing System 
    6
    c . In the DS1CONV Board Location
    : field, remove the c ab inet, 
    c arrier, and  slot that id entifies the physic al loc ation of DS1 
    Converter c irc uit p ac k in the first end p oint of the d up lic ate fib er link. 
    End p oint-1’s d uplic ate along  with Endp oint-2’s d up lic ate make up  
    the d up lic ate fib er link c alled  the B-PNC link.
    d. The DS1CONV Board Type
    : field is a display only field. 
    e. The Is one endpoint remoted via a DS1 Converter 
    Complex?
     field  must remain ad ministered  if other fib er c onnec tions 
    assoc iated  with the fac ility will remain. 
    3. Sc roll to sc reen 2.
    a. Remove the DS1 Converter Fac ilities information. In the Facility 
    Installed?
     field , typ e no
     for all fac ilities (A, B, C, and  D) to b e 
    removed .
    b. The Bit Rate
    : field  must remain ad ministered . 
    c . The id le c od e in the Idle Code MSB (1) . . . . LSB (8):
     
    field must remain administered. 
    d. The data in the Line Coding: 
    field  must remain ad ministered . 
    4. For a T1 site, p roc eed  to ‘‘T1 Installations Only’’
    . For an E1 site, proc eed  to 
    ‘‘E1 Installations Only’’
    .
    T1 Installations Only
    1. The Framing Mode:
     field  is d isp lay only.
    2. The DS1CONV-1 Line Compensation:
     and the DS1CONV-2 Line 
    Compensation:
     fields are display only. 
    3. Remove the Facility Circuit ID
     information from the fac ilities b eing  
    unad ministered , if used . Press 
    En t e r.
    4. A d isplay similar to the following  ap p ears after the p roc ed ure is 
    completed: 
    RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED
    .
    E1 Installations Only
    1. The CRC?
     field must remain administered.
    2. The Line Termination:
     field is display only.
    3. Remove the Facility Circuit ID
     information from fac ilities b eing  
    unad ministered , if used . Press 
    En t e r.
    4. A d isplay similar to the following  ap p ears after the p roc ed ure is 
    completed: 
    RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED
    . 
    						