Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-19 Release 5/6si to Release 8r 3 Figure 3-3. TDM/LAN Connections for Release 5/6si EPN Figure Notes 1. AHF110 TDM LAN/Bus Terminator 2. Slot 17 3. TDM/LAN Cab le (WP91716 L3) 4. Slot 00 5. Slot 036. Slot 18 7.J58890H Port Cab inet (“ D” Po si t io n ) 8. J58890H Port Cab inet (“ C” Po si t io n ) 9. J58890H Port Cab inet (“ B” Position) 10. J58890NExp ansion Control Cab inet (“ A” Position)
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-20 Release 5/6si to Release 8r 3 Connect TDM/LAN Cables and ICC Cables 1. Route and c onnec t the TDM/LAN c ab les. If any of the Release 5/6si p ort c ab inets (b eing up g rad ed to Release 8r c ab inets) were orig inally R1V3 p ort c ab inets, use the following step s to route a c ab le b etween an R1V3 up p er c ab inet and c ab inet b eneath it. Do not run a new c ab le throug h the existing slot in the rear shelf of the up p er c ab inet. a. Loosen the 2 left c onnec tor p anel sc rews, then remove the other 2 c onnec tor p anel sc rews. b . Attac h the TDM/LAN c ab le to the b ac kp lane and slid e the c ab le b etween the c onnec tor panel and the rear shelf (not throug h the existing slot in the shelf). Route the c ab le along the b ottom of the c ab inet. c . Rep lac e and tig hten the c onnec tor p anel sc rews. 2. For a c ritic al reliab ility system, c onnec t the ICC c ab les as shown in Table 3-4, Figure 3-4, and Figure 3-5. NOTE: For a d up lic ated c ab inet, d o not use the ICC c ab les (H600-259 G1) removed from the dup lic ated Release 5/6si PPN. Use the new ICC c ab les (H600-248 G1) sup p lied with the up g rad e. 3.On the “ A” c arrier, verify the CFY1 c urrent limiter (CURL) c onnec ts to p infield b loc k “ 00” (see Figure 3-4 ). Table 3-4. Intercabinet Cable Connections Connect ICC Cables From To Carrier Pin-Field Block Carrier Pin-Field Block EPN J58890N ICCA J58890H ICCA ICCB ICCB
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-21 Release 5/6si to Release 8r 3 Figure 3-4. ICC Pinfield Blocks on J58890N Expansion Control Cabinet Figure 3-5. ICC Pinfield Blocks on J58890H Port Cabinet 114 25 12 24 00 00 20 19 20 19 0 3 2 1 2 1 2 1 ICCB ICCA TERM CURL Pinfield 5.00 4.006.00 0 3 2 100 3.00 24 2.001.00 0.00 ICCB ICCA
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-22 Release 5/6si to Release 8r 3 Interconnect Port Networks with Fiber Optic Cabling — Standard Reliability Release 8r After all fib er op tic eq uip ment is installed , refer to Chapter A, ‘‘Fiber Link Administration’’. 1. Keep trac k of whic h fib er attac hes to whic h c onnec tor on eac h lig htwave transc eiver. Lab el every c ab le installed . This sec tion p rovid es fig ures showing typ ic al examp les of these c onnec tions. The c onnec tors on the lightwave transc eivers are lab eled “ TX” (transmit) or “ RX” (rec eive), while the fib ers attac hing to eac h c onnec tor are numb ered either “ 1” or “2.” See Figure 3-7 . Collocated Port Networks For a stand ard reliab ility system with 1 c olloc ated EPN, use 1 fib er op tic c ab le and 2 lig htwave transc eivers to d irec tly c onnec t the networks. For a stand ard reliab ility system with 2 c olloc ated EPNs, use 3 fiber optic c ab les and 6 lig htwave transc eivers to d irec tly c onnec t the networks. NOTE: Based on floor p lan c onsid erations, the leng th of these c ab les may vary. 20-foot (6.1 m) c ab les are normally ad eq uate for a Release 8r with 2 PNs. For c olloc ated c ab inets, route the fib er op tic c ab les d irec tly from the PPN to eac h EPN c ab inet. Sinc e a Release 8r PPN c ab inet is c olloc ated with a Sing le-Carrier Cab inet stac k, the p referred routing is to run the c ab les down the c ab le tray and out the b ottom of the PPN c ab inet. The c ab les are then run to the EPN c ab inet and up the outsid e of the rear p anels to the d esired c arrier level. Fiber Remoted Port Networks For a stand ard reliab ility system with 1 fib er-remoted EPN, use 2 fib er op tic cables,2 lightwave transceivers, and 2 lightguide interface units (provided by the PSC ). For a stand ard reliab ility system with 2 fib er-remoted EPNs, use 6 fib er op tic c ab les, 6 lig htwave transc eivers, and 6 lig htg uid e interfac e units (p rovid ed b y the PSC).
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-23 Release 5/6si to Release 8r 3 DS1 CONV-Remoted Port Networks For a stand ard reliab ility system with 1 DS1 CONV-remoted EPN, use 2 DS1 CONV c irc uit p ac ks (TN1654), 2 DS1 Conv-to-EI c ab les (846448637 and /or 846448645), two H-600-348 c ables, from 1 to 4 p airs of Channel Servic e Units (CSUs), and from 1 to 4 p airs of MDF c ab les (p rovid ed with the CSUs). NOTE: The TN1654 requires the use of a TN573B Switc hed Nod e Interfac e c irc uit pack For a stand ard reliab ility system with 2 DS1 CONV-remoted EPNs, this arrang ement req uires: n6 DS1 CONV c irc uit p ac ks (TN1654) n6 DS1 CONV-to-EI c ab les (846448637 and /or 846448645) n6 H-600-348 c ab les n3, 6, 9, or 12 p airs of CSUs n3, 6, 9, or 12 p airs of wall-field c ab les (p rovided with CSUs) n5, 10, or 15 d B attenuators (sing le-mod e fib er only) For 1 or 2 Collocated Expansion Port Networks 1. Behind p ort c arrier B of the multic arrier PPN. See Figure 3-6 and Figure 3-7: a. Install a lig htwave transc eiver on the c onnec tor at slot 1B02. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver b . Connec t 1 end of the ap p rop riate fib er op tic c ab le to the lig htwave transc eiver at slot 1B02. c . Route the fib er optic c ab le from the lig htwave transc eiver to the c ab inet’s c ab le tray and d own out of the c ab inet to the EPN stac k. d . Carefully attac h the fib er op tic c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. 5d B Attenuator 106060718 10d B Attenuator 106060734 15d B Attenuator 106061021
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-24 Release 5/6si to Release 8r 3 2. Behind control cabinet A of EPN stack 2: a. Install a lig htwave transc eiver on the c onnec tor at slot 2A01. b . Connec t the other end of the fiber op tic c able from the PPN to the lig htwave transc eiver at slot 2A01. c . Carefully attac h the fib er op tic c ab le (with c ab le ties) to the rear c overs of the EPN stac k. d . Coil up the surp lus leng th of fib er op tic c ab le, and p lac e the c oil either in the c ab le manag er or on the b ottom shelf (hold ing the p ower sup p ly) of the PPN c ab inet. Figure 3-6. Standard Reliability Release 8r with 2 or 3 Port NetworksFigure Notes 1. Cabinet 1 PPN 2. Cabinet Stac k 2 EPN 1 3. Cabinet Stac k 3 EPN 24. From Cab inet 3 A1 to Cab inet 1 C2 5. From Cab inet 2 A2 to Cab inet 3 A2 6. From Cab inet 1 B2 to Cab inet 2 A1
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-25 Release 5/6si to Release 8r 3 Figure 3-7. Typical Fiber Optic Connections For 1 or 2 Fiber-Remoted Expansion Port Networks 1. Behind p ort c arrier B of the multic arrier PPN. See Figure 3-6 and Figure 3-8: a. Install a lig htwave transc eiver on the c onnec tor at slot 1B02. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver b . Connec t a fib er op tic c ab le to the transc eiver just installed . c . Route the c ab le to the c ab inet c ab le tray and out of the c ab inet throug h the c ab le manag er to the PDS c ross-c onnec t fac ility. d . Connec t the fib er c ab le to the lig htg uid e interfac e unit p rovided . e. Carefully attac h the fib er op tic c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. Figure Notes 1. Lightwave Transc eiver 2. To PPN Carrier B Slot 1B02 3. To EPN 1 Carrier A Slot 2A01 (Cab inet Stac k 2)4. Fiber Optic Cable 5. TX Connec tor 6. RX Connec tor cydff05 CJL 103196 RX TX 2211
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-26 Release 5/6si to Release 8r 3 2. Behind control cabinet A of EPN stack 2: a. Install a lig htwave transc eiver on the c onnec tor at slot 2A01. b . Connec t a fib er op tic c ab le to the transc eiver just installed . c . Route the c ab le d own the outsid e of the rear c overs and throug h the c ab le manag er to the PDS c ross-c onnec t fac ility. d . Connec t the fib er op tic c ab le to the lig htg uid e interfac e unit. e. Carefully attac h the fib er op tic c ab le (with c ab le ties) to the rear c overs of the EPN stac k. f. Coil up the surp lus fib er op tic c able and p lac e the c oil in the c ab le manag er. Figure 3-8. Fiber Optic Connections PPN to EPN1 Figure Notes 1. Lightwave Transc eiver 2. PPN Carrier B Slot 1B02 3. EPN 1 Carrier A Slot 2A01 (Cabinet Stac k 2) 4. Fiber Optic Cable5. Fib er Op tic Cross-Connec t Fac ility 6. Lig htg uid e Interfac e Unit (LIU) 7. TX Connec tor 8. RX Connec tor cydf013 CJL102396 RX TX 2 22 1 11 22 11
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-27 Release 5/6si to Release 8r 3 Interconnect Port Networks with Fiber Optic Cabling — High Reliability Release 8r 1. Keep trac k of whic h fib er attac hes to whic h c onnec tor on eac h lig htwave transc eiver. This sec tion p rovid es fig ures showing typ ic al ways of making these c onnec tions. The c onnec tors on the lightwave transc eivers are lab eled “ TX” (transmit) or “ RX” (rec eive), while the fib ers attac hing to eac h c onnec tor are numb ered “ 1” or “ 2.” See Figure 3-10 . Collocated Port Networks For a high reliab ility system with 1 c olloc ated EPN, use 1 fiber op tic c able and 2 lig htwave transc eivers, or 1 sing le-mod e fib er op tic c ab le and 2 sing le-mod e lig htwave transc eivers to d irec tly c onnec t the networks. For a hig h reliab ility system with 2 c olloc ated EPN, use 3 fib er op tic c ab les and 6 lig htwave transc eivers, or 3 sing le-mod e fib er op tic c ab les and 6 sing le-mod e lig htwave transc eivers to d irec tly c onnec t the networks. NOTE: Based on floor p lan c onsid erations, the leng th of these c ab les may vary. 20-foot (6.1 m) c ab les are normally ad eq uate for a Release 8r with 2 p ort networks. For c olloc ated c ab inets, route the fib er op tic c ab les d irec tly from the PPN to eac h EPN c ab inet. Sinc e a Release 8r PPN c ab inet is c olloc ated with a Sing le-Carrier Cab inet stac k, the p referred routing is to run the c ab les down the c ab le tray and out the b ottom of the PPN c ab inet. The c ab les are then run to the EPN c ab inet and up the outsid e of the rear p anels to the d esired c arrier. Fiber-Remoted Port Networks For a hig h reliability system with 1 fib er-remoted EPN, use 2 fib er op tic c ab les, 2 lig htwave transc eivers, and 2 lig htg uid e interfac e units (p rovid ed b y the PSC). For a hig h reliab ility system with 2 fiber-remoted EPNs, use 6 fib er op tic c ab les, 6 lig htwave transc eivers, and 6 lig htwave-interfac e units (p rovid ed by the PSC). DS1 CONV-Remoted Port Networks For a high reliab ility system with 1 DS1 CONV-remoted expansion p ort network, use 2 DS1 CONV c irc uit p ac ks (TN1654), 2 DS1 CONV-to-EI c ab les (846448637 and /or 846448645), 2 H-600-348 c ab les, from 1 to 4 pairs of c hannel servic e units (CSUs), and from 1 to 4 p airs of wall-field c ab les (p rovid ed with the CSUs). NOTE: The TN1654 requires a TN573B Switc h Nod e Interfac e c irc uit p ac k
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-28 Release 5/6si to Release 8r 3 For a high reliab ility system with 2 DS1 Conv-remoted exp ansion p ort networks, this arrang ement req uires: n6 DS1 Converter c irc uit p ac ks (TN1654) n6 DS1 Converter-to-EI c ab les (846448637 and /or 846448645) n6 H-600-348 c ab les n3, 6, 9, or 12 p airs of CSUs n3, 6, 9, or 12 p airs of wall-field c ab les (p rovided with CSUs) For 1 or 2 Collocated Expansion Port Networks 1. Behind p ort c arrier C of the multic arrier PPN. See Figure 3-9 and Figure 3-10: a. Install a lig htwave transc eiver on the c onnec tor at slot 1C02. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver b . Connec t 1 end of the ap p rop riate fib er op tic c ab le to the lig htwave transc eiver at slot 1C02. c . Route the fib er optic c ab le from the lig htwave transc eiver to the c ab inet’s c ab le tray and d own, out of the c ab inet, to the EPN stac k. d . Carefully attac h the fib er op tic c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. 2. Behind c ontrol c ab inet A EPN stac k 2: a. Install a lig htwave transc eiver on the c onnec tor at slot 2A01. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver b . Connec t the other end of the fiber op tic c able from the PPN to the lig htwave transc eiver at slot 2A01. c . Carefully attac h the fib er op tic c ab le (with c ab le ties) to the rear c overs of the EPN stac k. d . Coil up the surp lus fib er op tic c ab le, and p lac e the c oil either in the c ab le manager or on the b ottom shelf (holding the p ower supp ly) of the PPN c ab inet.