    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
    1-5 Task Tables 
    1
    Verify Interchange (H/C only)1-15
    Upgrade other carrier (H/C only)1-15
    Affix position label(s)1-15
    Verify software version1-16
    Save Translations1-16
    Save Announcements (if necessary)1-16
    Restore Disk1-16
    Upgrade Software1-17
    Reset SPE status (H/C only)1-17
    List Configuration Control1-17
    Set Daylight Savings Rules1-18
    Set Date and Time1-19
    Set Core Dump Vector1-20
    Enable TTI1-20
    Release MMI (H/C only)1-21
    Resolve Alarms1-21
    Check Link Status1-21
    Enable Scheduled Maintenance1-21
    Enable Customer Options and Alarm Origination to INADS1-21
    Check SPE status (H/C only)1-22
    Save Translations1-22
    Save Announcements (if necessary)1-22
    Back Up Disk1-23
    Return Replaced Equipment1-23
    Continued on next page
    Table 1-2. Tasks to upgrade the software and hardware  — Continued
    ÖTask Description Page 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
    1-6 Upgrade the software and hardware 
    1
    Upgrade the software and hardware
    Check SPE
    1. Type status spe
     and press En t e r to c hec k the health of the SPE. 
    For hig h or c ritic al reliab ility systems:
    nTh e  Standby Refreshed
     field  shows yes
    nTh e  Standby Shadowing
     field  shows on
    nTh e  Standby Handshake
     field  shows up
    Save Translations
    1. Type save translation
     and press En te r to write all translation information 
    from memory to the d isk, whic h takes ab out 2 minutes.
    Save Announcements (if necessary)
    NOTE:
    The TN750C Announc ement c irc uit p ac k stores announc ements in 
    nonvolatile memory; saving  the announc ements is op tional.
    1. If the PPN c ontains a TN750/B Announc ement c irc uit p ac k, typ e display 
    announcements
     and  p ress 
    En te r.
    2. If administered  rec ord ed  announc ements are listed , typ e save 
    announcements 
    cabinet carrier slot and press En t e r. For example, 
    01
    D03. This takes ab out 30 minutes.
    NOTE:
    For some software load s, type save announcements from cabinet 
    carrier slot
    . Typ e help
     and  p ress En t e r for c omp lete c ommand 
    usag e.
    Back Up Disk
    1. Type backup disk
     and  p ress En t e r to write all information from the d isk to 
    the b ac kup  tap e. This takes 30 to 40 minutes.  
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
    1-7 Upgrade the software and hardware 
    1
    Disable Scheduled Maintenance and Alarm 
    Origination to INADS
    1. To p revent sc hed uled  d aily maintenanc e from interfering  with the up d ate 
    or up g rad e, typ e change system-parameters maintenance
     and  p ress 
    En t e r.
    2. If sc heduled maintenanc e has b eg un, set the Stop Time
     field  to 1 minute 
    after the c urrent time.
    or
    If sc hed uled  maintenanc e has not
     b eg un, set the Start Time
     field  to a 
    time after the upgrade is completed. For example, if you start the upgrade 
    at 8:00 p .m. and  the up g rad e takes 90 minutes, set the Start Time
     field  
    to 21:30.
    !CAUTION:
    If you d o not d isab le Alarm Orig ination, the system may g enerate 
    alarms, resulting  in unnec essary troub le tic kets.
    3. Type neither 
    in the Alarm Origination to OSS Numbers 
    field and 
    p ress 
    En t e r .
    NOTE:
    For some software load s, set the Alarm Origination 
    Activated
     field  to n 
    and 
    set the Cleared Alarm Notification 
    and  Restart Notification
     fields to disable
     or n
     b efore 
    pressing 
    En t e r. 
    Reconfigure the Tape (G3rV2, V3 R31.0 and 
    Earlier)
    NOTE:
    Do not issue the list configuration software 
    command before 
    reconfiguring the removable media.
    For some software load s, use 3-mem
     instead  of large
    If stand ard  reliab ility:
    1. Type configure tape large
     and press 
    En te r to reconfigure the bac kup 
    removab le med ia for the 2 TN1650B Memory c irc uit pac ks. This c ommand  
    takes ab out 1 minute to c omp lete. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
    1-8 Upgrade the software and hardware 
    1
    If hig h or c ritic al reliab ility:
    1. Type configure tape spe-a large
     and press 
    En t e r to rec onfig ure the 
    removable media in c ontrol c arrier “ A”  for 2 TN1650B Memory c irc uit 
    p ac ks. This c ommand  takes ab out 1 minute to c omp lete.
    2. Type configure tape spe-b large
     and  p ress 
    En te r to rec onfigure the 
    removab le media in c ontrol c arrier “ B”  for 2 TN1650B Memory c irc uit 
    p ac ks. This c ommand  takes ab out 1 minute to c omp lete.
    Check Link Status
    1. Type display communication-interface links
     and p ress En te r. Write d own 
    all enab led  links.
    2. Type status link
     
    number and  p ress En t e r. Rep eat this step  for all links.
    3. Write d own whic h links are in servic e.
    Disable TTI
    NOTE:
    Do this step only if the Terminal Translation Initialization (TTI) is enab led .
    !CAUTION:
    If you d o not d isab le the TTI, the translations c an b e c orrup ted .
    Make sure the ISDN is in servic e. If not, try to b usy out and  release the ISDN 
    D-c hannel/link to b ring  the ISDN trunks b ac k into servic e.
    1. Type change system-parameters features
     and press 
    En t e r. 
    2. On 
    the sec ond  sc reen, set the TTI Enabled?
     field to n 
    to d e-ac tivate the 
    TTI feature.
    Check Disk Drive
    1. Type list configuration control
     and press En t e r to c hec k the vintag e of the 
    d isk drive. If the d rive is V4 or later, g o to Check TTI Status
    .
    or
    If the d rive is 
    not V4 or later, g o to Install Disk Drive (if not TN1657 V4 or 
    earlier). 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
    1-9 Upgrade the software and hardware 
    1
    Install Disk Drive (if not TN1657 V4 or earlier)
    !CAUTION:
    When rep lac ing  any hardware, b e sure to g round  yourself against 
    elec trostatic  d isc harg e (ESD) b y wearing  a g round ed  wrist strap .
    !CAUTION:
    If a hig h or c ritic al reliab ility system, rep lac e and  restore the d isk d rives one 
    a t  a  t i m e  s t a r t in g  w it h  t h e  s t a n d b y  SPE.  N e v e r  re p la c e  t h e  a c t iv e  a n d  
    stand b y d isk drives at the same time.
    1. Type busyout host-adapter
     [a 
    | b
    ] 
    and press En t e r  to p revent other 
    ap p lic ations from ac c essing  the d isk or removab le med ia.
    2. Remove the existing  TN1657 Disk Drive c irc uit p ac k and  p lac e it in 
    antistatic  material.
    3. Insert a new TN1657 c irc uit p ac k into the DISK DRIVE slot.
    4. To p rop erly seat the c irc uit p ac k, p ush firmly on the front of the fac ep late 
    until the latc h reac hes the b ottom rail of the c arrier. Then c lose the latc h 
    until it is fully engaged.
    5. Type release host-adapter 
    [a 
    | b
    ] and  p ress 
    En te r  to release the d isk from 
    the maintenanc e-b usyout c ond ition and  p ut it b ac k into servic e.
    6. Type reset host-adapter 
    [a 
    | b
    ] 
    and press 
    En te r to allow the d isk to sp in 
    up .
    7. Type status spe
     and press 
    En t e r to verify that the d isk is now in servic e.
    NOTE:
    If the disk fails to return to servic e, rep eat Step s 1, 3, 4, and  5.
    For hig h or c ritic al reliab ility, rep eat step s 1 throug h 7 on the ac tive c arrier.
    Restore Disk
    NOTE:
    Until this c ommand finishes, the system p rovid es no user feed b ac k on the 
    manag ement terminal sc reen. Do not p ress 
    En t e r while the c ommand  
    exec utes. Doing  so c auses the terminal sc reen to c lear as the c ommand 
    finishes; erasing any suc c ess or failure messag es the system may p rovid e.
    If stand ard  reliab ility:
    1. Type restore disk full 
    and  p ress 
    En te r to c op y the information on the 
    removab le media to d isk, whic h takes ab out 30 minutes.
    If hig h or c ritic al reliab ility:
    1. Type restore disk full both
     and press 
    En t e r.  
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
    1-10 Upgrade the software and hardware 
    1
    Check TTI Status 
    1. Type status TTI
     and  p ress En te r. Wait until the Percent Complete
     field  
    shows 100%
    .
    Busyout MMI Circuit Packs (H/C only)
    !CAUTION:
    Multimed ia-to-voic e station c alls are not p reserved  on an up g rade. Failure to b usy-out 
    the TN787 Multimed ia Interfac e (MMI) c irc uit p ac ks results in unusab le TN787 and  
    TN788 Multimed ia Voic e Cond itioner p orts.
    1. Type display system-parameters customer-options
     and press En t e r. On 
    sc reen 2 und er the Multimed ia Call Hand ling  (MMCH) op tions, c hec k the 
    Basic
     and  Enhanced
     fields. 
    2. If either the Basic
     or Enhanced
     field  is y
    , typ e list configuration all
     and 
    p ress 
    En t e r  to loc ate all MMI (TN787) c irc uit p ac ks.
    3. If there are MMI c irc uit p ac ks, typ e busyout board 
    cabinet carrier slot 
    and  p ress 
    En t e r to remove the c irc uit p ac ks from servic e.
    Lock the active SPE (H/C only)
    1. Type status spe
     and press En t e r to d etermine whic h c ontrol c arrier is 
    ac tive or ob serve the c ontrol c arrier LEDs.
    NOTE:
    For hig h or c ritic al reliab ility systems, we rec ommend  that you 
    rep lac e the c irc uit pac ks in the stand b y c arrier first.
    !CAUTION:
    When rep lac ing  any hardware, b e sure to g round  yourself against 
    elec trostatic  d isc harg e (ESD) b y wearing  a g round ed  wrist strap .
    2. Move the SPE-SELECT switc hes on b oth Dup lic ation Interfac e (DUPINT) 
    circuit packs, 
    one at a time, to the ac tive c arrier.  
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
    1-11 Upgrade the software and hardware 
    1
    Check the active tone-clock (H/C only)
    1. Type status port-network 1
     and  verify that the Tone-Cloc k is in the same 
    c a r r ie r a s  t h e  a c t i v e  SPE a n d  t h a t  t h e  Service State
     field  shows in
    .
    NOTE:
    This takes 1 minute to c omp lete. If the servic e state is inc orrec t, 
    rep eat the c ommand  until this c ond ition is met.
    If the ac tive Tone-Cloc k has not migrated  to the ac tive c arrier after 
    1 minute, then a Tone-Cloc k p rob lem exists. Refer to the TDM-CLK 
    Maintenanc e Ob jec ts sec tion of the 
    DEFINITY Enterp rise Communic ations 
    Server Release 8 Maintenanc e for R8r
     b ook to resolve any p rob lems.
    Power Down the Processor Carrier
    !CAUTION:
    Do not p ower d own the whole c ab inet; it is not nec essary.
    For stand ard  reliab ility, p ower d own the p roc essor c arrier. This c auses a servic e 
    interrup tion.
    For high or critical reliability, power down the standby carrier.
    1. To power down the processor carrier, remove the power plug from the 
    left 
    sid e
     of the c arrier then remove the p ower p lug  from the right side of the 
    carrier. 
    Remove the Circuit Packs
    NOTE:
    More detailed  information on removing and  add ing  c irc uit p ac ks is in 
    Chapter 6, ‘‘Adding or Removing Cabinet Hardware’’
    .
    1. Remove the b lank fac ep late next to the MSSNET slot in the c arrier.
    2. Remove the UN332B circuit pack from the carrier and place it in antistatic  
    packing material.
    3. Remove the tap e from the tap e d rive.
    4. Remove the TN1656 tap e d rive and  p lac e it in antistatic  p ac king  material.  
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
    1-12 Upgrade the software and hardware 
    1
    Install the Circuit Packs
    NOTE:
    To p rop erly seat a c irc uit p ac k, p ush firmly on the front of the fac eplate until 
    the latc h reac hes the b ottom rail of the c arrier. Then c lose the latc h until it is 
    fully engaged.
    1. Insert the TN1650B memory c irc uit p ac k in memory slot 3.
    NOTE:
    If a hig h or c ritic al reliab ility system, install the TN1650B at the same 
    time as the op tic al d rive. Note that add ing  memory to the stand by 
    SPE c a u s e s a n  e rro r  b e c a u s e  t h e  m e m o r y n u m b e r b e t w e e n  t h e  
    standb y and  ac tive c arriers does not matc h.
    2. Insert the UN332C c irc uit p ac k into the MSSNET slot.
    3. Rep lac e the b lank fac ep late next to the MSSNET c irc uit p ac k.
    4. Insert the TN2211 optical drive (Figure 1-1
    ) into the rig ht most TAPE DRIVE 
    slot. It only takes up 2 slots.
    5. Plac e a b lank fac eplate over the left most TAPE DRIVE slot.
    Figure 1-1. TN2211 Optical Drive
    Red
    Green
    Yellow
    fpdf2211 KLC 010600TN2211 OPTICAL DRIVE 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
    1-13 Upgrade the software and hardware 
    1
    6. Plac e the formatted  removab le med ia, lab el fac ing  left, into the op tic al 
    drive.
    NOTE:
    Make sure the formatted removab le med ia is not write-p rotec ted 
    b efore p lac ing  it into the op tic al drive 
    (see Figure 1-2).
    Figure 1-2. Make sure the disk is not write-protected.
    !CAUTION:
    The removab le media has a slid ing , metal c over to p rotec t the 
    surfac e of the d isk. DO NOT TOUCH THE DISK (
    Figure 1-3).
    Figure Notes
    1. Not Write-p rotec ted 2. Write-p rotec ted
    h1dfdsk KLC 112499
    12 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
    1-14 Upgrade the software and hardware 
    1
    Figure 1-3. Do not touch the disk inside the cartridge.
    Power Up the Processor Carrier
    1. To restore p ower to the p roc essor c arrier, insert the p ower p lug  on the 
    right side of the c arrier then insert the p ower p lug  on the left sid e of the 
    carrier.
    If hig h or c ritic al reliab ility:
    2 . M o n it o r t h e  SPE a s  it  re b o o t s b y  o b se r vi n g  t h e  L ED s  a n d  t h e  t e r m in a l.  I t  is  
    p owered  up  when the YELLOW LED on the Proc essor c irc uit p ac k b links 
    in a stead y state, whic h takes ab out 10 minutes.
    Unlock the Active SPE (H/C only)
    1. Move the SPE SELECT switc hes to the AUTO position one at a time.
    2. Wait 10 minutes.
    !CAUTION:
    Allow 10 minutes after unlocking to make sure the standby SPE has 
    fully returned  to servic e.
    640MB
    2048BYTES
    /S
    EC
    TO
    R
    h1dfdsk1 KLC 091799 
    						