    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-69 Add IP Interface Assembly 
    6
    11. Typ e d omain name in the Domain
     field .
    12. If using  DNS, c lic k 
    Add  under the DNS Service Search Order
     field  and 
    type its IP ad d ress.
    13. Clic k on the WINS Ad dress tab . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-70 Add IP Interface Assembly 
    6
    14. Make sure the [ 2]  DEC shows in the Adapter
     field.
    15. If WINS server is availab le, typ e its IP ad d ress in the Primary WINS 
    Server
     field .
    16. If DNS is availab le, selec t Enable DNS for Windows Resolution
    .
    17. If the network uses an imp orted LMHOSTS file, selec t Enable LMHOSTS 
    Lookup 
    and Import LMHOSTS
     and c lic k OK
    .
    18. If the following  d ialog  b ox op ens, c lic k Ye s
    :
    At least one of the adapter cards has an empty primary 
    WINS address. Do you want to continue?
    19. Clic k the Bindings
     tab  to effec t the c hang es.
    NetBIOS Interface, Server, and Workstation should now be enabled. If any 
    are d isab led  (a red  c irc le with a line throug h it), review the p revious 
    network-c onfig uration step s for omissions or errors.
    20. Clic k Close
    . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-71 Add IP Interface Assembly 
    6
    If administered  remotely throug h p c ANYWHERE:
    21. Clic k on the p c ANYWHERE Restart Host Comp uter b utton on the toolb ar 
    to restart the c omputer.
    If administered  loc ally on a monitor, keyb oard, and  mouse:
    21. Clic k Ye s
     in the d ialog  b ox to restart the c omp uter. 
    !WARNING:
    When c onnec ted  remotely via p c ANYWHERE, only use the p c ANYWHERE 
    Restart Host Computer b utton on the toolb ar to restart Wind ows NT.
    Check Network Services
    When the server restarts, make sure that the req uired  network servic es have 
    started c orrec tly. If you see an error d ialog  b ox, then the network servic es d id  not 
    start c orrec tly. Also, c hec k the NT Event Log.
    1. Click on My Computer > Control Panel > Network > Services. 
    Make 
    sure that the following  servic es are listed:
    nComp uter Browser
    nMic rosoft Internet Information Server 2.0
    nNetBIOS Interfac e
    nRPC Config uration
    nSe r ve r
    nWorkstation
    2. Click the Protocols 
    tab , and examine the Network Protoc ols. TCP/IP 
    p rotoc ol should  b e the only one listed .
    3. Click OK
    .
    Test the External Connection to the LAN
    To test the external IP c onnec tions, p ing  the IP Interfac e server and  p ing  a known 
    c omp uter c onnec ted  to your network.
    1. Click Start > Programs > Command Prompt
    .
    2. Type ping 
    nnn.nnn.nnn.nnn (whic h is your IP ad d ress).
    nIf everything  is c onfigured  c orrec tly, the system respond s with the 
    following message:
    Reply from nnn.nnn.nnn.nnn: bytes=32 time
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-72 Add IP Interface Assembly 
    6
    3. At the c ommand p romp t, type ping nnn.nnn.nnn.nnn (whic h is the IP 
    ad d ress of your g ateway). 
    nIf everything  is c onfigured  c orrec tly, the system respond s with the 
    following message:
    Reply from nnn.nnn.nnn.nnn: bytes=32 time Settings > Control Panel > 
    Network
    . Selec t the Adapters
     tab  and  hig hlight the [ 2]  DEC 
    ad ap ter.
    nClic k Properties > Change
    . 
    nFrom the Duplex Mod e d ropd own menu, selec t a setting  that 
    matc hes the switc h/hub  that the TN802B c onnec ts to. For examp le, 
    10BaseT Full Dup lex or 10BaseT No Link Test
    4. At the c ommand p romp t, type ping 
    nnn.nnn.nnn.nnn (whic h is the IP 
    ad d ress of another external c omp uter beyond  the g ateway). 
    nIf you have c onnec tivity, the system respond s with the following  
    messag e:
    Reply from nnn.nnn.nnn.nnn: bytes=32 time Programs > Command Prompt
    .
    2. Type ping 
    192.11.13.9 (whic h is the IP ad d ress of the internal IP Interfac e 
    server). 
    nIf everything  is c onfigured  c orrec tly, the system respond s with the 
    following message:
    Reply from 192.11.13.9: bytes=32 time
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-73 Add IP Interface Assembly 
    6
    3. At the c ommand  p romp t, typ e ping 192.11.13.8 (whic h is the IP ad d ress of 
    the internal p roc essor). 
    nIf you have c onnec tivity, the system respond s with the following  
    messag e:
    Reply from 192.11.13.8: bytes=32 time
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-74 Add IP Interface Assembly 
    6
    Connect the Monitor, Keyboard, and Mouse
    1. Attac h a VGA monitor to the VGA c onnec tor of the TN802 IP Interfac e 
    external c ab le assemb ly.
    2. Attac h the keyb oard  to the KEYBOARD c onnec tor of the external c ab le 
    assemb ly.
    3. Attach the mouse to the MOUSE connector of the external c able 
    assemb ly.
    4. Plug  the monitor into an AC p ower rec ep tac le and  turn it on.
    5. If upg rad ing  loc ally, reb oot Wind ows NT b y p ressing  the rec essed  reset 
    b utton on the fac ep late (see Figure 6-26
    ) of the TN802B IP Interfac e until 
    the LCD shows a flashing  MSHUT *
    . When the flashing stops and the 
    asterisk d isap p ears (ab out 2 min), it is safe to remove the c irc uit p ac k.
    6. After the TN802B is shut d own, reseat the c irc uit p ac k to restart the 
    system.
    7. Log in using ctrl alt del
    Upgrading IP trunks (R7) to H.323 trunks
    If there are existing  IP trunk c onnec tions that you want to up g rad e to H.323 trunk 
    c onnec tions, d o the following  step s. Otherwise, g o to ‘‘Upgrade to TN802B (R8)’’ 
    on page 6-76
    To upg rad e an existing  IP trunk (R7) to an H.323 trunk (R8) req uires first g etting  
    IP information from the existing  TN802 b efore up g rad ing the TN802 to TN802B.
    1. Click on My Computer > Control Panel > Network
    .
    2. Click the Protocols
     tab .
    3. Select TCP/IP Protocol 
    from the list.
    4. Click the Properties
     op tion in the Network wind ow. Write d own the IP 
    ad d ress, sub net ad d ress, and  g ateway ad d ress shown for ad ap tor [2] 
    (see example b elow).
    NOTE:
    Do not use the ad d resses for ad ap ter [ 1] . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-75 Add IP Interface Assembly 
    6
    5. When d one, c lic k OK, OK
    . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-76 Add IP Interface Assembly 
    6
    Upgrade to TN802B (R8)
    NOTE:
    The upg rad e takes ab out 20 minutes.
    1. Insert the flash d isk into the rig ht most slot on the TN802 IP trunk. On the 
    monitor, a d ialog  b ox assig ns a d rive letter with the removab le med ia 
    d esig nation; the d efault is D:. 
    2. Rig ht c lic k on Start > Explore
     to op en the Wind ows NT Exploring  p ane 
    and  selec t the d rive letter ind ic ated in step  1.
    3. Double-clic k on Medpro 
    and  selec t the Setup  ic on.
    4. Follow the Install Shield  p roc ed ure to transfer all the nec essary files to the 
    TN802 IP Interfac e. 
    NOTE:
    In the Finish d ialog  b ox, selec t I will restart later
    . Do not 
    select Restart computer
    .
    This would  b e a g ood  time to read  the Read me.txt file.
    5. Click on Start > Settings > Control Panel > Services
    .
    6. Select IP Trunk 
    and click on Startup
    .
    NOTE:
    Do not c lic k on Start.
    7. Under Startup Type, select Disabled
     and  c lic k OK
     to d isab le IP Trunk 
    mod e.
    NOTE:
    If IP trunk and  Med Pro servic es are b oth set to automatic , the 
    TN802B d efaults to IP Trunk and  MedPro features c annot be used .
    8. Select MedPro 
    and c lic k on Startup
    .
    NOTE:
    Do not c lic k on Start.
    9. Under Startup Type, select Automatic
     and  c lic k OK
     to enab le Med Pro 
    mod e. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-77 Add IP Interface Assembly 
    6
    10. Clic k Start > Shut Down
     and  selec t Restart the computer?
    or on the TN802:
    Press the rec essed  reset b utton on the fac ep late (see Figure 6-26
    ) until 
    the LCD shows a flashing  MSHUT *
    . When the flashing stops and the 
    asterisk d isap p ears (ab out 2 min), reseat the c irc uit p ac k to restart the 
    system.
    or on the SAT:
    a. Type busyout board 
    UUCSS 
    and press En te r .
    b. Type reset board
     
    UUCSS and  p ress En te r. 
    c . Typ e release b oard  
    UUCSS and  p ress En te r. 
    Onc e the system is c omp letely initialized , the LCD read s MEDPRO *
    .
    !WARNING:
    When c onnec ted  remotely via p c ANYWHERE, only use the 
    p c ANYWHERE Restart Host Comp uter button on the toolb ar to 
    restart Wind ows NT.
    11. Affix the new TN802B lab el to the c irc uit p ac k.
    12. Disc onnec t the monitor, keyb oard , and  mouse. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-78 Add IP Interface Assembly 
    6
    Circuit Pack Verification
    1. Type change circuit-pack
     and  p ress En te r.
    2. Chec k the Cod e c olumn to see if it says DSMAPD or Med Pro.
    .
    3. To c orrec t it, g o to the entry just above the TN802B that says DSMAPD.
    4. Type MEDPRO, and press 
    En t e r. Changing  the one entry automatic ally 
    c hang es the entry ab ove it. If it is in IP Trunk mode, you g et the following 
    error message:
    MedPro type requires TN802 with application. Type 
    MEDPRO on circuit-packs form.
    5. To c omp lete the ad ministration, refer to the 
    DEFINITY ECS Release 8 
    Network Connec tivity
     b ook.
    change circuit-packs                                            Page   1 of   5 
                                  CIRCUIT PACKS                                     
            Cabinet: 1                            Carrier: A
                                             Carrier Type: processor        
     Slot Code  Sf Mode   Name               Slot Code  Sf Mode   Name
    11: MEDPRO RESERVED-IP
    01: TN754  DIGITAL LINE  12: MEDPRO  RESERVED-IP
    02: TN758  POOLED MODEM  13: TN802  B  MAPD BOARD
    03: TN2144  ANALOG LINE  14: 
    04: TN746  B  ANALOG LINE  15: 
    05 16:         
    06: TN771  C  MAINTENANCE/TEST  
    07: TN464  F  DS1 INTERFACE     
    08: TN2140  E&M TIE TRUNK     
    09: TN767  E  DS1 INTERFACE     
    10: TN799  B  CONTROL-LAN       
      # indicates circuit pack conflict. 
    						