Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-23 Standard Reliability 5 Unpack and Inspect Expansion Control Carrier 1. Insp ec t the new J58890AF Exp ansion Control Carrier for any d amag e. Also verify that the b ac kp lane p ins are not b ent. 2. Plac e the exp ansion c ontrol c arrier on the floor so that the rear of the carrier faces up. 3.Install the CFY1 c urrent limiter (CURL) on the “ A” c arrier to the p in-field b loc k lab eled “ CURL” Install the CURL with the c omp onents on the left. 4. At the rear c onnec tor p anel, d etermine whic h c onnec tors will have a c ab le attac hed , and install a 4B c ab le retainer on eac h of these c onnec tors. Install New Expansion Control Carrier A 1. Install the c arrier in p osition “ A” b y alig ning the p lastic alig nment tip s on the top rear of the c arrier with the sc rew holes in the c ab inet. These alig nment tip s sup p ort the c arrier while installing the sc rews. Ensure that the p ower c ord s are prop erly p lac ed in the slots at the sid es of the c arrier. 2. Fasten the c arrier into p osition with 4 self-tap p ing sc rews saved from the removal of the old c arrier. NOTE: Carefully realig n the thread s on the self-tap p ing sc rews b y turning them c ounterc loc kwise 1 turn b efore tig htening them to avoid strip p ing the thread s out of the framework. 3. Connec t the “ P2” and “ P1” c ab les to the “ A” c arrier. See Figure 5-3 . Snap the c onnec tor loc k into p lac e to ensure the c onnec tion is p roperly mad e. 4. Connec t the 8 g round strap s from the “ C” c arrier to the new “ A” c arrier. See Figure 5-2 . 5. Connec t the 8 g round strap s from the “ D” c arrier to the new “ A” c arrier. 6. For AC-p owered systems, install the 2 new g round strap s. One strap c onnec ts ground p oint “ 1” to the “ A” c arrier frame (rig ht sid e), and the other c onnec ts ground p oint “ 8” to the “ A” c arrier frame (left sid e). NOTE: DC-p owered systems d o not use these c arrier g round strap s. 7. Connec t the remaining end of the TDM/LAN c able (b etween the “ A” and “ D” c arriers) to the pin-field bloc k marked “ TDM” on the rig ht sid e of the “A” carrier. See Figure 5-4 and Table 5-7. 8. Connec t the remaining end of the TDM/LAN c able (b etween the “ A” and “ C” c arriers) to the p in-field b loc k marked “ TDM” on the left sid e of the “ A” carrier.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-24 Standard Reliability 5 Figure 5-4. TDM/LAN Connections for Standard Reliability Release 8 EPN Figure Notes 1.Port Carrier (“ C” Position) 2. ZAHF4 TDM/LAN Terminator 3. TDM/LAN Cab le (WP91716 L6) 4. Mod ule Control Carrier (“ A” Position) 5. Port Carrier (“ D” Position)6 . Po r t C a rr i e r ( “ E” Po si t io n ) 7. Slot 21 8. Slot 01 9. TDM/LAN Cable (WP91716 L7) 10. Control Carrier (“ B” Position)
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-25 Standard Reliability 5 9. On p ort c arrier J58890BB-1, c onnec t the TDM c ab le or TDM terminator to Slot 02. On p ort c arriers J58890BB-2 and J58890BB-3, c onnec t the TDM c ab les to Slot 01. 10.Install the front trim p late on the “ A” c arrier. Install the fan trim plate. 11. Install the p ower units (removed from G2 universal module) into the “ A” c arrier. Do not interc hang e the p hysic al loc ations of the units. The 631AR1, 631WA1, 631DA1, or 644A install in the left sid e, while the 631BR1, 631WB1, 631DB1, or 645B install in the rig ht sid e. NOTE: In most c ases, the new Release 8 c arrier will c ontain the same p ower sup p lies as in the existing system. However, a Release 8 c arrier may c ontain a 649A Power Unit. If so, re-use the p ower units from the G2 power module. 12. If the exp ansion c ontrol c arrier c ontains a 631BR1, 631WB1, or 645B p ower unit, install the p reviously removed TN736 p ower unit in p ort slots “ 18” and “ 19” of the c arrier (ad jac ent to the 631BR1, 631WB1, or 645B). If the system is eq uip p ed for neon messag e waiting , a TN752 or TN755 power unit must be used. NOTE: The TN736 is not required when the 631DB1 or 645B p ower unit is used in the J58890AF-1 exp ansion c ontrol c arrier or the J58890BB-2 or J58890BB-3 p ort c arriers. It is req uired in the J58890BB-1 p ort c arrier, regard less of whic h 631 power unit is p rovid ed . Use the TN752 or TN755 if the system c ontains neon messag e waiting . 13. Connec t the white p ower c ord s to the p ower units. Table 5-7. TDM/LAN Connections J Number Carrier Type LHS Slot RHS Slot J58890BB-1 Port 21 02 J58890BB-2 Port 21 01 J58890BB-3 Port 21 01 J58890AF EPN Control “ A” 21 02
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-26 Standard Reliability 5 Install Circuit Packs 1. Install the new Release 8 control c irc uit p ac ks into c arrier “ A.” Use the new lab el and the annotated “ list c onfig uration all” (p rovid ed with the Release 8 removable med ia) as a g uid e. NOTE: Currently, the TN768 Tone-Cloc k c irc uit p ac k resid es in a p ort slot of the universal mod ule b eing up grad ed . Reloc ate this c irc uit p ac k to the “ TONE CLOCK” slot of c arrier “ A.” Luc ent Tec hnolog ies rec ommend s up grad ing to the TN2182 Tone-Cloc k. 2. Install c irc uit p ac k b lanks in slots not eq uip p ed with c irc uit p ac ks. 3. For a d irec tly-c onnec ted stand ard reliab ility Release 8 system with 2 p ort networks, ensure the PPN and this EPN are b oth eq uip p ed with a TN776 or TN570 Exp ansion Interfac e c irc uit p ac k. For a d irec tly-c onnec ted system with 3 p ort networks, ensure the PPN and eac h EPN have two TN776 or TN570 c irc uit p ac ks. Interconnect Port Networks Fiber op tic c abling terminated to 9823A lig htwave transc eivers c an interc onnec t PNs up to 4,900 feet (1493 m) ap art. Fib er op tic c ab ling terminated to 9823B lig htwave transc eivers c an interc onnec t PNs up to 25,000 feet (7620 m) ap art. The 300A fib er optic lightwave transc eiver c an interc onnec t PNs up to 115,000 feet (21.7 miles, 35 km) ap art. NOTE: These d istanc e limits are ap p roximate measurements of the ac tual fib er rig ht-of-way (not of the shortest linear d istanc e) b etween the 2 end points. NOTE: It is imp ortant to lab el every c ab le that you install. NOTE: Keep trac k of whic h fib er attac hes to whic h c onnec tor on eac h lig htwave transc eiver. This sec tion p rovides fig ures offering sug gested ways of making these c onnec tions. The c onnec tors on the lig htwave transc eivers are lab eled either “ TX” (transmit) or “ RX” (rec eive), while the fib ers attac hing to eac h c onnec tor are numb ered either “ 1” or “ 2.” A viab le fib er c onnec tion is only mad e when b oth fibers in eac h c ab le (“ 1” and “ 2” ) route from the “ TX” c onnec tor of a p ort network to the “ RX” c onnec tor of its ad jac ent p ort network. See Figure 5-6. NOTE: When finished , refer to Appendix A, ‘‘Fiber Link Administration’’ to ad minister the fiber links.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-27 Standard Reliability 5 Collocated Port Networks For a stand ard reliab ility system with 1 c olloc ated EPN, use 1 fib er op tic c ab le and 2 lig htwave transc eivers to d irec tly c onnec t the networks. For a stand ard reliab ility system with 2 c olloc ated EPNs, use 3 fiber optic c ab les and 6 lig htwave transc eivers to d irec tly c onnec t the networks. NOTE: Based on floor-p lan c onsid erations, the leng th of these c ab les may vary. 20 foot (6.1 m) c ables are normally ad eq uate for a Release 8 with 2 p ort networks. For c olloc ated c ab inets, route the fib er optic c ab les d irec tly from the PPN to the EPN c ab inet. If a “ DEFINITY style” PPN c ab inet is c olloc ated with another “ DEFINITY style” EPN c ab inet, the p referred routing is to run the c ab les up the c ab le tray and out the top of the PPN c abinet. The c ab les are then run to the other c ab inet, throug h the top of the c ab inet, and d own the c able tray to the desired carrier level. If a “ DEFINITY style” PPN c ab inet is c olloc ated with either a small c ab inet, med ium c ab inet, or sing le-c arrier c ab inet stac k, the p referred routing is to run the cables down the c ab le tray and out the bottom of the PPN c ab inet. The c ab les are then run to the EPN c ab inet and up the outsid e of the rear panels to the desired carrier level. Fiber-Remoted Port Networks For a stand ard reliab ility system with 1 fib er-remoted EPN, use 2 fib er op tic c ab les, 2 lig htwave transc eivers, and 2 lig htg uid e interc onnec t units (p rovid ed b y the PSC). For a stand ard reliab ility system with 2 fib er-remoted EPNs, use 6 fib er op tic c ab les, 6 lig htwave transc eivers, and 6 lig htg uid e interc onnec t units (p rovid ed b y the PSC). For fib er-remoted c ab inets, route the c ab les down the c ab le tray and out the b ottom of the c ab inet to the MDF where the lightg uide interc onnec t units are loc ated . In either c ase, use c ab le ties to sec ure the c ab le ag ainst the walls of the c ab le tray at the c ab le tie p ositions b uilt into the trays.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-28 Standard Reliability 5 For Either 1 or 2 Collocated Expansion Port Networks 1. Behind c ontrol c arrier A of PPN c ab inet 1 (see Figure 5-5, Figure 5-6, and Figure 5-7 ): nInstall a lig htwave transc eiver on the c ab le c onnec tor at slot 1A01. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver nConnec t 1 end of the fib er optic c ab le to the lightwave transc eiver, just installed , at slot 1A01. nCarefully attac h the fib er op tic c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. 2. Behind control carrier A of EPN c abinet 2: nInstall a lig htwave transc eiver on c ab le c onnec tor at slot 2A01. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver nConnec t the other end of the fiber op tic c able to the lig htwave transc eiver, just installed , at slot 2A01. nCarefully attac h the fib er op tic c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. nAt the top of the c ab inet, c oil up the surp lus fiber op tic c ab le and attac h it to the wall of the c able tray.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-29 Standard Reliability 5 For Two Collocated Expansion Port Networks 1. Behind control carrier A of PPN c abinet 1: nInstall a lig htwave transc eiver on c ab le c onnec tor at slot 1A02. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver nConnec t 1 end of the fib er optic c ab le to the lightwave transc eiver, just installed , at slot 1A02. nCarefully attac h the fib er op tic c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. 2. Behind control carrier A of EPN c abinet 3: nInstall a lig htwave transc eiver on c ab le c onnec tor at slot 3A01. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver nConnec t the other end of the fiber op tic c able to the lig htwave transc eiver, just installed , at slot 3A01. nCarefully attac h the fib er op tic c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. nAt the top of the c ab inet, c oil up the surp lus fiber op tic c ab le and attac h it to the wall of the c able tray. 3. Behind control carrier A of EPN c abinet 2: nInstall a lig htwave transc eiver on c ab le c onnec tor at slot 2A02. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver nConnec t 1 end of the fib er optic c ab le to the lightwave transc eiver, just installed , at slot 2A02. nCarefully attac h the fib er op tic c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-30 Standard Reliability 5 4. Behind control carrier A of EPN c abinet 3: nInstall a lig htwave transc eiver on c ab le c onnec tor at slot 3A02. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver nConnec t the other end of the fiber op tic c able to the lig htwave transc eiver, just installed , at slot 3A02. See Figure 5-8 . nCarefully attac h the fib er op tic c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. nAt the top of the c ab inet, c oil up the surp lus fiber op tic c ab le and attac h it to the wall of the c able tray. Figure 5-5. Standard Reliability Release 8 with Two or Three Port NetworksFigure Notes 1. Cabinet 1 Proc essor Port Network 2. Cabinet 2 Exp ansion Port Network 13. Cab inet 3 Exp ansion Port Network 2
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-31 Standard Reliability 5 Figure 5-6. Fiber Optic Connections PPN to EPN1 Figure 5-7. Collocated Fiber Optic Connections PPN to EPN2 Figure Notes 1. Lightwave Transc eiver 2. To PPN Carrier A Slot 1A01 3. To EPN 1 Carrier A Slot 2A014. Fiber Optic Cable 5. TX Connec tor 6. RX Connec tor Figure Notes 1. Lightwave Transc eiver 2. To PPN Carrier A Slot 1A02 3. To EPN 1 Carrier A Slot 3A014. Fiber Optic Cable 5. TX Connec tor 6. RX Connec tor cydff05 CJL 103196 RX TX 2211 cydff05 CJL 103196 RX TX 2211
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-32 Standard Reliability 5 Figure 5-8. Collocated Fiber Optic Connections EPN1 to EPN2 For Either One or Two Fiber-Remoted Expansion Port Networks 1. At c ontrol c arrier A of PPN c ab inet 1. See Figure 5-5 throug h Figure 5-9. nInstall a lig htwave transc eiver on the c ab le c onnec tor at slot 1A01. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver nConnec t a fib er op tic c ab le to the transc eiver just installed . nRoute the c ab le to the c ab le tray and d own, out of the c ab inet, throug h the c ab le manag er to the PDS c ross-c onnec t fac ility. nConnec t the fib er c ab le to the lig htguid e interc onnec t unit p rovid ed . nCarefully attac h the c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. 2. Behind control carrier A of EPN c abinet 2: nInstall a lig htwave transc eiver on c ab le c onnec tor at slot 2A01. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver nConnec t a fib er op tic c ab le to the transc eiver just installed . Figure Notes 1. Lightwave Transc eiver 2. To PPN Carrier A Slot 2A02 3. To EPN 1 Carrier A Slot 3A024. Fiber Optic Cable 5. TX Connec tor 6. RX Connec tor cydff05 CJL 103196 RX TX 2211