    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-9 Add the Fiber Optic Cable 
    6
    LASER Product
    CLASS 1 LASER PRODUCT
    IEC 825 1993
    The DEFINITY ECS may c ontain a Class 1 LASER devic e if sing le-mod e fib er 
    op tic  c ab le is c onnec ted  to a remote Exp ansion Port Network (EPN). The LASER 
    d evic e op erates within the following  p arameters:
    nMaximum Power Outp ut: -5d Bm
    nWaveleng th: 1310 nm
    nMod e Field  Diameter: 8.8 mic rons
    !CAUTION:
    Use of c ontrols or ad justments or p erformanc e of p roc ed ures other than 
    those sp ec ified  herein may result in hazard ous rad iation exp osure.
    Contac t your Luc ent Tec hnolog ies rep resentative for more information.
    Table 6-2. Parts List
    Quantity Description Comcode
    1 Pass-thru Tool  847978715
    1 Beig e SC-SC Fib er Op tic  Ad ap ter (multimod e) 107118903
    1 Beig e ST-SC Fib er Op tic  Ad ap ter (multimode) 107087967
    1 Ten-foot (3 m) Fib er Op tic  Cab le (multimod e) 107122640
    1 I/O Connec tor Ad ap ter Brac ket 847978673
    1 Fiber Op tic  Cab le Disc onnec t Lab el  848029286
    10 Cab le Ties  407814672
    6 Cab le Tie Mounts  403053150 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-10 Add the Fiber Optic Cable 
    6
    Cabinet Preparation
    1. Open the front d oor.
    NOTE:
    Ad ministration may b e req uired  b efore removing  the c irc uit p ac k in 
    the following  step .
    2. Determine which slot (1 or 2) will c ontain the new fiber optic circuit pac k. 
    Remove the c irc uit p ac k or the b lanking  p late from this slot. 
    NOTE:
    If a c irc uit p ack is removed  from the req uired  slot, it must b e installed  
    into a d ifferent slot in the c ab inet. All translations assoc iated  with this 
    c irc uit pac k must also b e moved .
    3. Remove the c irc uit p ac k or the b lanking  p late from the slot next to the slot 
    d etermined  in step  2. Two c onsec utive op en slots are req uired  to install 
    the fib er op tic  ad ap ter.
    NOTE:
    If a c irc uit pac k was removed  in step  3, it will be rep lac ed  into the 
    same slot, later in this sec tion.
    4. Install the new c irc uit p ac k.
    5. Open the rear d oor.
    6. From the rear, remove the I/O c ab le c onnec tor assoc iated  with the slot that 
    will c ontain the new fib er op tic  c irc uit p ac k. See Figure 6-2
    . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-11 Add the Fiber Optic Cable 
    6
    Figure 6-2. Remove the I/O Cable Connector
    7. Using  a sup p lied  c able tie, sec ure the removed  I/O c onnec tor to nearb y 
    c ab ling. See Figure 6-3
    . Figure Notes
    1. Press tab  down 2. Pull c onnec tor forward
    lcda8fop RPY 021198
    1
    2 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-12 Add the Fiber Optic Cable 
    6
    Figure 6-3. Secure the I/O Cable Connector
    8. From the front, remove the fan c over. See Figure 6-4
    . Figure Notes
    1. Tie wrap
    lcda9fop RPY 0213981 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-13 Add the Fiber Optic Cable 
    6
    Figure 6-4. Remove the Fan Cover
    lcda3fop EWS 110398
    ENTER
    /YES ENTER
    /YES NEXT
    /NO NEXT
    /
    NO BACK
    BACK
    AUDIX AUDIXBOOT/
    SHUTDOWN BOOT/
    SHUTDOWN
    ALARMS
    ALARMS
    EMERTR
    EMERTR 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-14 Add the Fiber Optic Cable 
    6
    Install the Pass-thru Kit
    1. Snap  the SC-SC fib er op tic  adap ter on the p ass-thru tool. See Figure 6-5. 
    Use the b eig e ad apter even if sing le-mod e fib er is b eing  installed . The 
    SC-SC ad ap ter is b etter suited  for c ab le routing  in the next step s. 
    NOTE:
    If sing le-mod e fib er is being installed , the b eige ad ap ter will b e 
    rep lac ed  with a b lue ad ap ter, later in this sec tion.
    Figure 6-5. Fiber Optic Adapter and Pass-Thru Tool 
    2. Slid e the tool to the rear of the c ab inet. See Figure 6-6
    . Figure Notes
    1. Pass-thru Tool 2. SC-SC Fib er Op tic  Ad apter 
    dafocoup RPY 062497
    1 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-15 Add the Fiber Optic Cable 
    6
    Figure 6-6. Insert the Pass-thru Tool
    !CAUTION:
    Avoid  b end ing  fib er op tic  c ab les to a rad ius smaller than 1.5 inc hes 
    (3.8 c m), to p revent mec hanic al stress on the c ab les. 
    !CAUTION:
    During  the ac tual installation of fiber op tic  c omp onents, use either all b eig e 
    or all b lue ad ap ters. Beig e d enotes multimod e fib er and  b lue d enotes 
    sing le-mod e fib er. Do not mix b eig e with b lue. 
    3. Attac h the sup plied  fib er op tic  c ab le to the ad ap ter. 
    lcda2fop RPY 021098 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-16 Add the Fiber Optic Cable 
    6
    4. Pull the tool (with ad apter and  c ab le attac hed ) out throug h the front of the 
    c ab inet. See Figure 6-7
    .
    Figure 6-7. Fiber Optic Cable and Adapter
    5. From the rear, route the fib er op tic  c ab le throug h the op ening  vac ated  b y 
    the I/O c able c onnec tor.
    6. If nec essary, remove the fiber ad ap ter from the tool and p lug  the fib er 
    op tic  c ab le into the SC-SC (sing le-mod e) or ST-SC (multimod e) ad ap ter. 
    See Figure 6-8
    . Chec k the house c ab ling  b efore selec ting  a c oup ling  to 
    use.
    7. From the front of the I/O c onnec tor ad ap ter b rac ket (with fib er c ab le), 
    snap  the c oup ling  into the sup p lied I/O c onnec tor ad apter b rac ket. 
    8. Snap  the I/O c onnec tor ad ap ter b rac ket into the I/O c onnec tor op ening .
    9. Attac h the outside fiber p lant to the I/O c onnec tor on the rear of the 
    c ab inet.
    lcda6fop RPY 021698 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-17 Add the Fiber Optic Cable 
    6
    Figure 6-8. Bracket Attachments 
    10. Wrap  the c ab le d isc onnec t lab el around  the fib er op tic  c ab le. See 
    Figure 6-9
    . Figure Notes:
    1. Fiber cable
    2. I/O c onnec tor ad ap ter b rac ket3. SC-SC adapter
    4. SC-ST ad ap ter
    lcda7fop KLC 051198
    1
    2
    3
    4
    2 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-18 Add the Fiber Optic Cable 
    6
    Figure 6-9. Cable Disconnect Label
    11. Close the rear door.
    !CAUTION:
    Avoid  b end ing  fib er op tic  c ab les to a rad ius smaller than 1.5 inc hes 
    (3.8 c m), to p revent mec hanic al stress on the c ab les. Plan the use of 
    c ab le ties to avoid c rimping  the c ab le or c reating  a fixed stress point 
    where, at a later time, movement of the c ab le c auses it to exc eed  the 
    minimum b end  rad ius.
    !CAUTION:
    Be c areful not to c rimp the fib er c ab le when you are p erforming  the 
    following step.
    12. Rep lac e the fan c over. See Figure 6-10. Figure Notes
    1. To outside p lant fib er
    prda0001 RPY 021898
    1 
    						