Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-129 Add MCC Port Carriers 6 Save Translations 1. Log in at the manag ement terminal. 2. If the system is hig h- or c ritic al-reliab ility, typ e status spe and press En te r to verify that the stand b y SPE is refreshed and that the stand b y d isk is in servic e. 3. Type save translation [spe-a or both] disk and press En t e r. This c ommand instruc ts the system to take all translation information in memory and write it to the d isk(s). 4. If the MCC p ort network c ontains a TN750 Announc ement c irc uit p ac k, type display announcements and press En t e r. If administered rec ord ed announc ements are listed , typ e list configuration software-version and p ress En t e r. Chec k sc reen 2 to find out when the announc ements were last saved . Save the c urrent announc ements b y typ ing save announcements and p ressing En t e r. 5. Type backup disk [spe-a or both] and p ress En te r. This c ommand instruc ts the system to b ac kup the c urrent information on disk to the system tap e(s). 6. Up d ate b ac kup tape(s), if required . Shut Down DEFINITY LAN Gateway System If a DEFINITY LAN Gateway system resid es in the c ontrol c ab inet to b e up g rad ed , p rep are to shut d own the DEFINITY LAN Gateway assemb ly and allow the disk to c omp letely sp in d own. !CAUTION: Make sure that you save the system p arameters if you p lan to reuse the c urrent system. !WARNING: Neg lec ting to shut d own a DEFINITY LAN Gateway assemb ly b efore p owering d own the system c ab inet where it resides c an d amage the LAN Gateway d isk. 1. Unseat the LAN Gateway assemb ly from its b ac kp lane c onnec tors in the carrier. 2. Log onto the DEFINITY LAN Gateway. See the DEFINITY Communic ations System Generic 3 Installation, Ad ministration and Maintenanc e of CallVisor ASAI over the DEFINITY LAN Gateway . 3. When the main menu ap p ears, selec t Maintenanc e. 4. Select Reset System from the Maintenanc e menu. 5. Select Sh u t d o w n from the Res et Sy ste m menu.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-130 Add MCC Port Carriers 6 Shut Down DEFINITY AUDIX System 1. If a DEFINITY AUDIX resides in the MCC p ort network to b e up g rad ed , shut d own the AUDIX assemb ly and allow the d isk to c ompletely sp in d own. Refer to ‘‘DEFINITY AUDIX Power Procedures’’ on page 6-141 . !WARNING: Neg lec ting to shut d own an AUDIX assembly b efore p owering d own the system c ab inet where it resides c an damag e the AUDIX d isk. 2. Unseat the AUDIX assemb ly from its b ac kp lane c onnec tors. Power Down MCC Port Network 1. At the MCC p ort network, set the main c irc uit b reaker to OFF. Install Port Carrier 1. Open the rear d oors. 2. Remove the b lank p ort c arrier p anel by pushing outward on panel from the rear of the c ab inet until the p anel c lears the 4 retaining p ins on the c ab inet frame. See Figure 6-49 . 3. Use a sc rewd river to loosen and remove the 4 retaining p ins from the c ab inet frame. 4. Alig n the c arrier throug h the front of the system c ab inet with the 4 p ilot holes on c ab inet frame. NOTE: Support the carrier by the molded-in support pins above the top mounting holes. 5. Insert self-tapp ing sc rews in the p ilot holes and tighten. 6. Attac h the mag netic ally-held nomenc lature panel to front of c arrier. 7. At the rear, install 8 g round ing jump ers from the adjac ent b ac kp lane to the new c arrier b ac kp lane wiring (Figure 6-50 and Figure 6-51). 8. Connec t a 9-p in D sub miniature p lug on rig ht sid e of c ab inet to P1 c onnec tor on c arrier. If nec essary, c ut the tie wrap holding the interc ab inet c ab le to the up rig ht in the area of the c arrier b eing installed. 9. Connec t the TDM/LAN c ab le to the newly installed p ort c arrier. See Figure 6-52, Figure 6-53, Figure 6-54, or Figure 6-55 and Table 6-11.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-131 Add MCC Port Carriers 6 10. Install a 631AR, 631WA1, 631DA1, or 644A p ower unit in the leftmost slot and a 631BR, 631WB1, 631DB1, 645B, or 649A p ower unit in the rig ht-most slot of installed p ort c arrier as follows: a. Set the c irc uit b reaker on the p ower unit to be ad d ed to OFF. b. Move locking slide on power unit to its leftmost position and open the lever. c . Alig n and slid e the p ower unit into slot in the c arrier until some resistance is felt. d . Lift the loc king lever upward until it latc hes. e. Move the loc king slid e on p ower unit to its rig htmost p osition. f. Connec t a p ower c ord insid e the c ab inet to the outlet on the p ower unit. g . Set the c irc uit b reaker on the p ower unit to ON. 11. Install a TN736 p ower c onverter in the slot next to the 631AR p ower c onverter or a TN752 p ower c onverter in the slot next to the 631WA1 p ower c onverter on the left sid e of the c arrier. NOTE: The TN736 is not required when the 631DB1 p ower unit is used in the J58890B-2 or J58890B-3 p ort c arriers. It is req uired in the J58890B-1 p ort c arrier reg ardless of whic h 631 p ower unit is p rovid ed . Use the TN752 or TN755B if the system is eq uip p ed with neon messag e waiting . 12. Install the p ort c irc uit p ac ks in the c arrier. 13. Connec t the AC/DC p ower c ord s loc ated insid e the c ab inet to the p ower units. 14. Install the rear p anels around the p ort c arrier. 15. Install c ab les from the p ort c arrier to the MDF. 16. Install the c ab le ac c ess panel, as req uired . Reseat DEFINITY LAN Gateway System 1. Reseat the LAN Gateway assemb ly into its b ac kp lane c onnec tors in the carrier. Reseat DEFINITY AUDIX System 1. Reseat the AUDIX assemb ly into its bac kp lane c onnec tors.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-132 Add MCC Port Carriers 6 Power Up MCC Port Network 1. At the MCC p ort network, set the main c irc uit b reaker to ON. 2. The system p erforms a level 4 reb ooting proc ess, load ing the system p rog ram and d efault translations from the d isk. Reb ooting takes 5 to 11 minutes. 3.Refer to “ Initialization and Rec overy” and “ LED Interp retation” c hap ters in DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8 r , for c irc uit pac k LED ind ic ations and manag ement terminal d isplays that occ ur during system reboot. 4. After the system reb oot is finished and all troub le c leared , verify that the EMERGENCY TRANSFER CONTROL switc h is set to AUTO. This restores the system to the normal op erating mod e. Restart DEFINITY LAN Gateway System 1. Log onto the DEFINITY LAN Gateway. 2. When the main menu ap p ears, selec t Maintenanc e. 3. Select Reset System from the Maintenanc e menu. 4. Select Restart System from the Reset System menu. Enter Added Translations 1. Enter ad ded translation d ata as ap p lic ab le using D EFINITY En terp ris e Communic ations Server Release 8 Ad ministrator’s Guid e . Resolve Alarms and Enable Alarm Origination 1. Examine the alarm log . Resolve any alarms using DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8r . 2. If the Alarm Origination Activated field ad ministration is alread y set to y , b e sure to enab le Alarm Orig ination. Otherwise you d o not need to enab le Alarm Orig ination (p roc eed to the next sec tion). 3. Type change system-parameters maintenance and press En t e r. Th e Alarm Origination Activated field was c hang ed to Alarm Origination to OSS Numbers to sup p ort more than 1 OSS.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-133 Add MCC Port Carriers 6 4. Type first-only in this field to enab le Alarm Orig ination (to the first OSS, which should be INADS). Be sure to typ e y in both Cleared Alarm Notification and Restart Notification field s. Press En te r. NOTE: The INADS Datab ase Ad ministrator enab les Alarm Orig ination as p art of the reg istration proc ess. !CAUTION: If you d o not enab le Alarm Orig ination when the c ustomer has purc hased a services contract, the switc h will not report any alarm to the TSC automatic ally, c ausing the TSC to b e unab le to fulfill the servic es c ontrac t. Save Translations 1. If the system is hig h- or c ritic al-reliab ility, typ e status spe and press En te r to verify that the stand b y SPE is refreshed and that the stand b y d isk is in servic e. 2. Type save translation [spe-a or both] disk and press En t e r. This c ommand instruc ts the system to take all translation information in memory and write it to the d isk(s). 3. If the MCC p ort network c ontains a TN750 Announc ement c irc uit p ac k, type list configuration software-version and press En te r. If sc reen 2 shows that rec ord ed announc ements were saved , these announc ements c an b e restored using the restore announc ements command. Type restore announcements and p ress En te r. 4. Type backup disk [spe-a or both] and p ress En te r. This c ommand instruc ts the system to b ac kup the c urrent information on disk to the removab le med ia.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-134 Add MCC Port Carriers 6 Update Port-Assignment Records 1.Up d ate the c ustomer’s p ort-assig nment rec ord s. Figure 6-49. Blank Carrier Panel (Rear View) Figure 6-50. Locations of Grounding Jumpers (Small Cabinet) CABINET FRAME RETAINING PINS PORT CARRIER B CONTROL CARRIER A CABINET REAR VIEW (COVERS REMOVED)FANS GROUNDING JUMPER
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-135 Add MCC Port Carriers 6 Figure 6-51. Locations of Grounding Jumpers PORT CARRIER C PORT CARRIER B CONTROL CARRIER A FANS PORT CARRIER D PORT CARRIER E REAR VIEW (COVERS REMOVED) GROUNDING JUMPERS GROUNDING JUMPERS CABINET
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-136 Add MCC Port Carriers 6 Figure 6-52. TDM/LAN Bus Connections for Standard Reliability R8r PPN NOTE: On p ort c arrier J58890BB-1, c onnec t the TDM c ab le or TDM terminator to slot 02. On p ort c arriers J58890BB-2 and J58890BB-3, c onnec t the TMD c ab les or TDM terminator to slot 01. If the p ort c arrier has J58890BB-1 and J58890BB-2 stenc illed on it, treat it as a J58890BB-1. Figure Notes 1.Port Carrier (“C” Position) 2. ZAHF4 TDM/LAN Terminator 3. TDM/LAN Cab le (WP91716L6) 4.Process Carrier (“A” Position) 5. Port Carrier (“ D” Position) 6. Port Carrier (“ E” Position)7. Slot 21 8. Slot 00 9. TDM/LAN Cab le (WP91716L7) 10. Port Carrier (“ B” Position) 11. Slot TDM/LAN2 (20) cadf052 KLC 102297 12 2 3 3 4 5 6 7 7 7 7 7 8 9 103
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-137 Add MCC Port Carriers 6 Figure 6-53. TDM/LAN Bus Connections for Critical-Reliability PPN NOTE: On p ort c arrier J58890BB-1, c onnec t the TDM c ab le or TDM terminator to slot 02. On p ort c arriers J58890BB-2 and J58890BB-3, c onnec t the TMD c ab les or TDM terminator to slot 01. If the p ort c arrier has J58890BB-1 and J58890BB-2 stenc illed on it, treat it as a J58890BB-1. Figure Notes 1.Port Carrier (“C” Position) 2. ZAHF4 TDM/LAN Terminator 3. TDM/LAN Cab le (WP91716L6) 4.Process Carrier (“A” Position) 5. Port Carrier (“ D” Position) 6. Port Carrier (“ E” Position) 7. Slot 218. Slot 00 9. TDM/LAN Cab le (WP91716L7) 10. Process Carrier (“B” Position) 11. ICCD Connec tor 12. ICCC Connec tor 13. Interc arrier Cable D (WP-91954) 14. Interc arrier Cable C (H600-182) cadf051 KLC 102297 12 2 3 3 3 4 5 6 7 7 7 7 7 8 8 9 1011 12 13 14
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-138 Add MCC Port Carriers 6 Figure 6-54. TDM/LAN Bus Connections for Standard- or High-Reliability EPN CONTROL CARRIER SLOT 21 B A D PORT CARRIER PORT CARRIER SLOT 21 PORT CARRIER TERMINATOR TDM BUS SLOT 21 E (ZAHF4) SLOT 21 C REAR VIEWPORT CARRIER (ZAHF4) SLOT 21 EXPANSIONJ58890AF J58890BB J58890BB J58890BB J58890BB SEE NOTE SEE NOTE SEE NOTE SEE NOTE NOTE: ON PORT CARRIER J58890BB-1, CONNECT THE TDM CABLE OR TDM TERMINATOR TO SLOT 02. ON PORT CARRIERS J58890BB-2 AND -3, CONNECT THE TDM CABLES TO SLOT 01. SLOT 02 TDM/LAN BUS TERMINATOR TDM/LAN CABLE WP91716 L6 WP91716 L7 TDM/LAN CABLE WP91716 L6 TDM/LAN CABLE TDM/LAN CABLE WP91716 L6