Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-49 Release 5/6si to Release 8r 3 Reconnect Cables 1. Behind eac h EPN c ab inet p ower sup ply, set the c irc uit b reaker to OFF. NOTE: Powering d own an EPN c ab inet without p owering d own the PPN will set off alarms. However, these alarms should c lear after p ower is restored to the EPN. 2. Rep lac e all c ab les that were lab eled and removed. 3. Install the top and b ottom rear c overs. Be sure the c orrec t rear c overs are installed on the new J58890N Exp ansion Control Cab inet. Do not use these rear c overs on the p ort c abinets. NOTE: The rear c overs for Release 8r c ontrol c arriers may need 2 d etents (1 for the TDM/LAN c ab le and another for the ICC c ab les). If the Release 5/6si was up g rad ed to a c ritic al reliab ility Release 8r and the EPN was orig inally an R1V3, rep lac e the lower rear c over of p ort c ab inet “ B” with a new c over (846307817) so the ICC c ab les and the new g round p late c an be installed b etween c ab inets “ A” and “ B.” Power Up the EPN Cabinet 1. Behind eac h EPN c ab inet p ower sup ply, set the c irc uit b reaker to ON. After ab out 40 sec ond s, EPN power and PPN/EPN c ommunic ations return. 2. After p ower returns to the EPN and all troub le is c leared, verify the EMERGENCY TRANSFER CONTROL switc h is set to AUTO. This restores the system to the normal mod e. Install Rear Ground Plates (Systems with Earthquake Protection) 1. Loosen the 4 sc rews at the b ottom of the top c ab inet and at the top of the c ab inet und erneath the top c ab inet. See Figure 3-17 . 2. Alig n the mounting holes in the rear g round p late over the b ottom sc rews in the top c ab inet. See Figure 3-17 . 3. Alig n the mounting holes in the g round p late with the 4 holes at the top of the c ab inet b elow the top c ab inet. Slid e the mounting p late d own to seat on the sc rews. 4. Chec k all TDM b us c ab les and the ICC to b e sure they are not p inc hed b y the p lates. 5. Rep eat Step s 1-3 until the rear ground p lates are installed b etween all stacked cabinets. 6. Do not tig hten the sc rews yet.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-50 Release 5/6si to Release 8r 3 Install Front Ground Plates (Systems with Earthquake Protection) Use 1 front g round p late b etween 2 stac ked c ab inets. 1. At the front of the c ab inets, alig n the holes in the top of the front g round p late with the holes at the b ottom of the up p er c ab inet, and insert the 4 sc rews. Do not tighten the sc rews yet. See Figure 3-17 . 2. At the front of the c ab inets, alig n the holes in the b ottom of the front g round p late with the holes at the top of the lower c ab inet. Insert the 4 sup p lied #12-24 x 1/2-inc h (1.27 c m) thread -forming sc rews. Do not tig hten the sc rews yet. 3. Rep eat Step s 1 and 2 until all stac ked c abinets are fastened tog ether. 4. Tighten all screws securely. Figure 3-17. Rear Ground Plate and Front Plate or Cabinet Clip — Side View Figure Notes 1. Front Ground Plate or Cab inet Clip 2. Battery3. Rear Ground Plate 3 2 1 grdpltec LJK 031096
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-51 Release 5/6si to Release 8r 3 Install Cabinet Clips (Systems without Earthquake Protection) A c ab inet c lip is required b etween eac h p air of stac ked c ab inets. 1. At the front of the c ab inets, install a c ab inet c lip b etween eac h p air of c ab inets b y hooking the c lip into the slot of the up per c ab inet and snap p ing the straig ht leg of the c lip into the slot on the lower c ab inet. See Figure 3-18 . Figure 3-18. Location of Cabinet Clips Figure Notes 1. Control Cab inet 2. Port Cab inet or Exp ansion Control Cab inet 3. Port Cab inet4. Port Cabinet 5. Cabinet Clips
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-52 Release 5/6si to Release 8r 3 Install Cable Clamps 1. Behind the c ab inets, using sc rews p rovid ed , install 2 c ab le c lamp s on eac h g round p late. See Figure 3-19 . These clamps hold the port cables. Figure 3-19. Location of Ground Plate and Cable Clamps Retranslate Port Circuits If p ort c irc uit p ac ks in the Release 5/6si c ontrol c ab inet were reloc ated in ord er to: nUse a TN748B to rep lac e the tone d etec tor c irc uits on a TN756 nPut a c ritic al p ort c irc uit p ac k, req uiring long er nominal b attery hold over (a DS1 or an Announc ement c irc uit p ac k), in a p ort slot nPut a TN570 EI c irc uit p ac k in p ort slot 1 or p ort slot 2 (for a sec ond EPN) nPut a TN755B power supply in port slots 16 and 17 1. Verify the port c irc uit p ac ks were retranslated d uring the off-site software up g rad e. If not, retranslate them now. Refer to DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e . Figure Notes 1. Port Cab inet 2. Control Cab inet3. Cab le Clamp s 4. Ground Plate cadf008 CJL 103096
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-53 Release 5/6si to Release 8r 3 Re-record Announcements (TN750/B Only) 1. The off-site STS translation up g rad e does not p reserve the c ontents of rec ord ed announc ements. Therefore, if a TN750/B Announc ement c irc uit p ac k resid es in the system, re-rec ord the announc ements that were stored on the c irc uit p ac k. NOTE: If a TN750C resid es in the system, re-rec ord ing of announc ements is not nec essary. Administer Fiber Links 1. After all fib er op tic eq uip ment is installed , refer to Chapter A, ‘‘Fiber Link Administration’’. Enable TTI 1. Type change system-parameters features and press En t e r. 2. On the sec ond sc reen, set the Enabled? field to y to ac tivate the TTI feature. Check Link Status 1. Type display communication-interface links and p ress En t e r. 2. Make note of all enab led links. 3. Type status link and p ress En t e r. 4. Chec k the following items and note whic h links are in-servic e. nPPP li n k s nAud ix links nCMS links at b oth end s (Also, c hec k the rec overy time.) nASAI links at the DEFINITY ECS end 5. Chec k that DS1 trunks and BRI p hones are func tioning normally. 6. Rep eat steps 3 - 5 for eac h enab led link. Resolve Alarms 1. Examine the alarm log . Resolve any alarms using DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8r .
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-54 Release 5/6si to Release 8r 3 Enable Customer Options and Alarm Origination to INADS 1. Get the DOSS order number of the upgrade from the project manager and ask the reg ional Customer Software Ad ministration to c omp lete the step s in the shad ed b ox. See ‘‘Where to Call for Tec hnic al Sup p ort’’ on p ag e -xx for telep hone numb ers. NOTE: As p art of the system reg istration p roc ess, the INADS Datab ase Ad ministrator enab les Alarm Orig ination. 2. When ad ministration is c omp leted , log in as craft at the Login: prompt. init login administration: 1. Log in as init . 2. Type change system-parameters customer-options and press En te r to verify that the c ustomer op tions are p roperly set. 3. Go to sc reen 6, QSIG Op tional Features, and set the Basic Call Setup field to y if the customer was using Supplementary Services Protoc ol b or d on an ISDN-PRI trunk g roup b efore the up g rad e. 4. Type change system-parameters offer-options and p ress En te r. 5. If the Activate Offer field is n , set it to y and press Ta b. A warning messag e lets you know whether you need to save translations and reb oot to make the c hang e p ermanent. 6. Press En t e r to effec t the c hang es or Canc el if there were no c hang es. 7. Contac t the req uester when d one.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-55 Release 5/6si to Release 8r 3 Save Translations 1. Type save translation and press En te r to g et up g rad ed translations onto d isk. If the translations were c orrup ted d uring the up g rad e, the following error message displays when logging in: !WARNING: Translation c orrup tion d etec ted ; c all Luc ent Tec hnolog ies d istrib utor immed iately. NOTE: Th e save translation c ommand c annot func tion if the translation c orruption messag e ap p ears. Return Replaced Equipment 1. Return rep lac ed eq uip ment to Luc ent Tec hnolog ies ac c ord ing to the req uirements outlined in: BCS/Material Log istic s, MSL/Attend ed Stoc king Loc ations Method s and Proc ed ures for Basic Material Returns
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-56 DEFINITY AUDIX Power Procedures 3 DEFINITY AUDIX Power Procedures Power Down the AUDIX System A yellow c aution stic ker on the system’s power unit notifies tec hnic ians to shut d own the DEFINITY AUDIX System p rior to p owering d own the system. 1. Log into the AUDIX System as craft . 2. Type reset system shutdown and press En t e r. Press En te r onc e. NOTE: Do not p ress En t e r again. This will forc e the AUDIX to shutd own immed iately, d rop p ing all ac tive c alls on the AUDIX. 3. The “ SHUTDOWN Comp leted ” messag e ap p ears when the AUDIX is suc c essfully shutd own. This takes ab out 2 minutes. 4. The AUDIX System can now b e removed for service. Power Up the AUDIX System nIf the AUDIX was removed from the c ab inet: 1. Re-install the AUDIX and allow it to b oot up automatic ally. 2. Check for AUDIX System errors. nIf the AUDIX remained in the c ab inet b ut p ower was removed from the c ab inet: 1. Power up the c ab inet. The AUDIX reb oots automatic ally. 2. Check for AUDIX System errors. nIf the AUDIX remained in the c ab inet and the c ab inet was not powered down: 1. At the AUDIX c onsole, hold the crtl key and typ e cc . 2. Type 5 at the p romp t. In ab out 2 minutes, the AUDIX b oots up . 3. When the system initialization is c omp lete, log in as craft . 4. Check for AUDIX System errors.
G3vs with Intel 386 or Risc Processor to R8r 4-1 4 DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 4 G3vs with Intel 386 or Risc Processor to R8r This c hapter p rovid es the information nec essary to p erform an up g rad e from either a Release 5/6 system with a RISC Proc essor, or from a Generic 3 (G3) vs system with an Intel ® 386 p roc essor, to a Release 8r system. The up g rad e to a Release 8r system req uires a major c hang e of hard ware and software. The p ort c irc uit p ac ks from the p resent system may b e reused only if a site insp ec tion d etermines that the p ort c irc uit p ac k vintages are usab le in the Release 8r. Some of the I/O c ab les from the existing system may b e too short to reac h from the Release 8r c abinet to the Main Distrib ution Frame (MDF). If so, the c ab les must b e rep lac ed as p art of the up g rad e proc ess.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 G3vs with Intel 386 or Risc Processor to R8r 4-2 Read This First 4 Read This First Service Interruption This up g rad e p roc ess req uires a servic e interrup tion that d ep end s on whether the Release 8r c abinet c an b e installed while the p resent system is in servic e. In this c ase, the servic e interrup tion may only b e ab out 2 hours. If, however, the p resent system must b e removed to allow room for the Release 8r c ab inet, then the servic e interrup tion may b e 8 hours, or more. This up g rad e must b e c losely c oord inated with the c ustomer and the loc al ac c ount team. Call Management System (CMS) The CMS link is dropped and restarted during the upgrade. This causes CMS d ata to b e lost. This d ata loss c an be minimized if the up g rad e is p erformed just after the last CMS measurement interval. All measurement d ata is lost d uring the up g rad e (inc lud ing BCMS). If need ed , the reports may be printed before the upgrade begins. CMS c ould ab ort the p roc essing of a c all if a measured trunk that was part of the c onferenc e d rop p ed off the c all b efore the end of the c all. Customers exp erienc ing this symp tom and who are running R3V4 CMS should upd ate to r3v4ao.e or hig her. Preventing Translation Errors When instruc ted in this c hap ter, p erform the save translation c ommand . Afterward , c hec k for translation errors b efore p roc eed ing with the up g rad e. NOTE: Be sure that the translations g et saved without errors b efore c ontinuing with any up g rad e. If errors are d etec ted , refer to ‘‘No Translations After Upgrade’’ in Appendix B, ‘‘Troubleshooting an Upgrade’’ to c orrec t the p rob lem. Do not c ontinue with the up g rad e until the errors are c orrec ted . Communication Between Equipment Rooms For an up g rad e where some of the eq uip ment resid es at a remote loc ation, the up g rad e ac tivity is muc h easier if temp orary c ommunic ation is established b etween the equip ment rooms.