    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							Troubleshooting  an Upgrade 
    B-1  
    B
    DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    B
    Troubleshooting  an Upgrade
    This ap pend ix p rovid es information to c orrec t some p rob lems when upg rad ing  a 
    system. The information in this app end ix is a c omp ilation of the most c ommonly 
    rep orted  troub les rec eived b y Tier 4 Sup p ort at Luc ent Tec hnolog ies. For g eneral 
    information on troub leshooting  assoc iated  with maintenanc e p roc ed ures, see 
    one of the following  referenc es:
    nChapter 5, Alarms, Errors and  Troub leshooting , of the Release 8.2, 
    Maintenanc e for R8r manual 
    This ap p end ix may b e up d ated  with new information at eac h p roduc t/d oc ument 
    release. If you have troub leshooting or error rec overy information that you think 
    would  b e valuab le to other tec hnic ians, p lease FAX your c omments to us at 
    1-303-538-1741 (United  States). 
    This ap p end ix is org anized  into three main sec tions, as d esc rib ed  b elow:
    nNew for Release 8 – p rovid es information on introd uc tions for Release 8 
    that might result in upgrade problems
    nTroubleshooting Guidelines – provid es g eneral p roc ed ures to try b efore 
    esc alating  a p rob lem
    nTroubleshooting Release 8 Upgrades – p rovid es spec ific  troub leshooting  
    p roc ed ures for c ommon up g rad e p rob lems 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Troubleshooting  an Upgrade 
    B-2 New for Release 8 
    B
    New for Release 8
    nATM PNC Duplication (ATM PNC-DUP)
    nATM Expansion Interface (ATM-EI)
    nMass Storage System 
    nControl LAN (C-LAN)
    nControl LAN (C-LAN)
    nSystem Links (SYS-LINK)
    ATM PNC Duplication (ATM PNC-DUP)
    The PNC-DUP maintenanc e ob jec t trac ks the health of the ac tive and  stand b y 
    PNCs, c ontrols p lanned  and  sp ontaneous interc hanges, and  manag es related  
    func tions suc h as d oub le c all refresh and  unrefresh, antithrashing, and  so on. 
    The main resp onsib ility of PNC-DUP is to rec over the system to full servic e in the 
    event of a fault. In the event of multip le faults, PNC-DUP d oes its best to 
    maximize servic e c ontinuity.
    In systems with the Critic al Reliability op tion, the following  c omp onents, whic h 
    tog ether c omp rise the Port Network Connec tivity (PNC), are d up lic ated :
    nATM-Exp ansion Interfac e (ATM-EI) c irc uit p ac ks in the port networks (PNs)
    nFiber-optic  c ab les c onnec ting  the ab ove c irc uit pac ks to the ATM Switc h 
    Interfac e Mod ules
    nATM  Sw i t c h
    Althoug h not p art of the PNC, Tone-Cloc k c irc uit p ac ks are also d up lic ated  in 
    eac h PN. All systems have one Proc essor Port Network (PPN). ATM PNC systems 
    c an have up  to 43 EPNs.
    PNC d up lic ation arc hitec ture utilizes an ac tive/stand b y d up lic ation sc heme in 
    whic h one c omplete set of PNC c omp onents sup p orts c all p roc essing , while the 
    d up lic ate PNC is held  in reserve. All c alls on the ac tive PNC are simultaneously 
    set up , or shad owed , on the stand b y PNC in ord er for it to b e c apab le of instantly 
    assuming  ac tive status when nec essary, allowing  for interc hang es without 
    servic e d isrup tion (in the c ase of sing le faults).
    PNC d up lic ation d oes not introd uc e any ad ditional typ es of hard ware or 
    hard ware faults, and  there are no tests assoc iated with the PNC-DUP MO. 
    Instead , its error log  entries c ontain useful information ab out the oc c urrenc e and  
    c auses of interc hang es in ord er to fac ilitate d iag nosis of p roblems, whic h c an 
    then b e ad dressed b y using  the d oc umentation for the ind ivid ual maintenanc e 
    ob ject involved. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Troubleshooting  an Upgrade 
    B-3 New for Release 8 
    B
    The following PNC d up lic ation-related  c ommand s and  their outp ut sc reens are 
    fully d esc rib ed in Chap ter 8, Maintenanc e Command s, of the 
    DEFINITY ECS 
    Release 8 Maintenanc e for Release R8r
     b ook.  The assoc iated  PNC-DUP 
    maintenanc e ob jec t is found  in Chap ter 9 of the same referenc e.
    ATM Expansion Interface (ATM-EI)
    The ATM-EI maintenanc e ob jec t c overs the ATM c irc uit p ac k administered  as an 
    ATM-Port Network Connec tivity (PNC) Exp ansion Interfac e (ATM-EI). The ATM-EI 
    p rovid es PNC b etween a DEFINTY PPN and  all the EPNs throug h the ATM 
    switc h.
    The circuit packs listed below are ATM-EI boards 
    if they are ad ministered to 
    serve the ATM Port Network Connec tivity (ATM-PNC) for DEFINITY
    .
    Mass Storage System
    The Mass Storag e System (MSS) p rovid es non-volatile storag e for system 
    software, translation d ata, announc ement d ata and  p rog ram up d ate d ata. As 
    shown in the fig ure b elow, the MSS c onsists of a Host Ad ap ter c irc uit on the 
    U N 3 3 2 C  M SS- N e t w o r k C o n t ro l c i rc u it  p a c k ( M SSN ET) ,  a  Sm a l l C o m p u t e r  Sy st e m  
    Interfac e (SCSI) b us, a TN2211 Op tic al Drive c irc uit p ac k or a TN1656 Tap e 
    Drive c irc uit p ac k, and  the TN1657 Disk Drive c irc uit pac k. The Disk Drive ac ts 
    as the p rimary storag e d evic e. The TN2211 Op tic al Drive or TN1656 Tap e Drive 
    serves as a b ac kup  d evic e and  as a removab le med ium for system d ata.status pnc
    Disp lays information ab out the op erational status of b oth 
    PNCs inc lud ing  state of health, alarms, b usyouts and  loc ks, 
    and so on.
    reset pnc 
    interchangeUsed to initiate a demand  PNC interc hang e. If the stand by 
    is healthy (state of health ind exes all zero), there is no 
    effect on service. Otherwise, calls may be dropped.
    set pnc
    Used to lock or unlock the active PNC, preventing 
    interc hang es. It d oes not interfere with d oub le c all setup .
    busyout pnc
    Removes the stand b y PNC from servic e. 
    Circuit pack FiberEcho 
    cancellation
    TN2305B Multi mod e Y
    TN2306B Sing le mode Y
    Continued on next page 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Troubleshooting  an Upgrade 
    B-4 New for Release 8 
    B
    Troub leshooting  details for the Mass Storag e System may b e found  und er the 
    R-MEDIA
     maintenanc e ob jec t in Chap ter 9, Maintenanc e Ob jec t Rep air 
    Proc ed ures, of the Release 8.2, Maintenanc e for R8r manual. Ad d itional related  
    maintenanc e ob jec ts assoc iated  with the Mass Storag e System inc lud e 
    STO-DATA
    , DISK
    , and  H-ADAPTR
    .
    Figure B-1. TN2211 faceplate
    The system is usually b ooted  from the b oot imag e stored  on d isk. The save 
    translation
     and  save announcements
     commands save to d isk the 
    memory-resid ent translation d ata and  TN750-resid ent announc ement data, 
    resp ectively. The backup disk
     c ommand c op ies d ata from the d isk to the 
    removab le med ia for b ac kup  storag e. The restore disk
     c ommand  c op ies d ata 
    f ro m  t h e  re m o v a b l e  m e d ia  b a c k  t o  d i sk .  A ll  M SS c o m p o n e n t s re s id e  in  t h e  SPE,  
    o r  PPN  c o n t ro l c a r ri e r  ( c a r r ie r A f o r  a  s im p le x  SPE,  c a rr i e r s A a n d  B f o r  a  
    duplicated SPE).
    The removab le media c irc uit p ac k c ontains SCSI b us terminators, a -48V to + 12V 
    p ower c onverter, an industry stand ard  SCSI-b ased  removab le med ia d rive, and  
    interfac e c irc uitry to the p rivate b us to c ontrol the LEDs, d etec t the p resenc e of 
    the c irc uit p ac k, and  id entify the vintag e of the hard ware.
    Red
    Green
    Yellow
    fpdf2211 KLC 010600TN2211 OPTICAL DRIVE 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Troubleshooting  an Upgrade 
    B-5 New for Release 8 
    B
    A -48V to + 12V c onverter c irc uit on the TN2211 Op tic al Drive c irc uit p ac k 
    p rovid es p ower for b oth the Op tic al Drive and  the Disk Drive. The p resenc e of 
    + 12V on these c irc uit p ac ks is monitored  sep arately b y maintenanc e software so 
    that a failure of the + 12V c onverter on the Removab le Med ia c irc uit pac k c an b e 
    id entified  or ruled  out as the sourc e of the p rob lem when the Disk Drive loses 
    + 12V p ower.
    The Host Ad ap ter c irc uit p ac k, Removab le Med ia Drive c irc uit p ac k, and  Disk 
    c irc uit p ac k are treated  as sep arate, b ut related , maintenanc e ob jec ts 
    (H-ADAPTR, R-MEDIA, and DISK). Sinc e the Disk c irc uit p ac k is c ontrolled  b y 
    SCSI c ommand s whic h are g enerated  b y the Host Ad apter, p rob lems with the 
    Host Ad ap ter c an p revent c ommunic ations with the Disk. Whenever the Host 
    Ad apter is taken out of servic e b y the busy-out host-adapter
     c ommand , or d ue 
    to failure of a c ritic al Host Ad apter test, the Removab le Med ia (R-MEDIA) and  
    Disk (DISK) maintenanc e ob jec ts are also p lac ed  in a maintenanc e b usyout 
    state.
    Figure B-2. Mass Storage System interactions
    Switch
    processorSystem
    memory
    System bus
    Host
    adapter MSSNET
    circuit
    packSCSI bus
    Private bus
    Disk
    circuit
    packDisk
    driveTape
    driveOptical
    drive
    Disk TapeOptical
    disk Tape
    circuit
    packOptical
    drive
    circuit
    pack
    +12V
    SPE
    Mass
    storage
    system
    cydfmass LJK 092999 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Troubleshooting  an Upgrade 
    B-6 New for Release 8 
    B
    Control LAN (C-LAN)
    The TN799 Control LAN (C-LAN) p ac ket p ort c irc uit p ac k p rovid es TCP/IP 
    c onnec tion to ad junc ts app lic ations suc h as CMS, Intuity, and  DCS Networking . 
    The C-LAN c irc uit p ac k has 1 10b aseT Ethernet c onnec tion and  up  to 16 DS0 
    p hy si c al  in t er f ac es  f o r PPP c o nne c t io ns .  Put t i ng  mu lt i p le  C -LAN  c irc ui t  p ac k s  int o 
    a -system g ives ad d itional TCP/IP c ap ac ity. In ad d ition to the TCP/IP func tionality, 
    CLAN extends the ISDN capabilities for csi models by providing Packet bus 
    ac c ess.
    A re m o t e  s o c ke t  c o n t ro l  l in k  ( RSC L )  li n k s t h e  C - L AN  a n d  t h e  SPE t o  p a ss  c a ll  
    c ontrol and other management information. Sinc e one link serves all the p orts on 
    the c irc uit p ac k, maintenanc e of the RSCL is p art of the C-LAN c irc uit p ac k 
    maintenanc e.
    The C-LAN TN799 c irc uit p ac k c omb ines the func tions of the PGATE and  PI 
    c irc uit p ac ks into one c irc uit p ac k. The PGATE or PI c an b e used  with the C-LAN 
    to c reate an X.25-to-TCP/IP b rid g e for ad junc t and DCS c onnec tivity.
    Maintenanc e ob jec ts assoc iated  und er the Control LAN area inc lud e CLAN-BD 
    (Control LAN Circ uit Pac k), ETH-PT
     (Control LAN Ethernet), and PPP-PT 
    (Control 
    LAN Pac ket/Port).
    System Links (SYS-LINK)
    System Links are pac ket links that orig inate at the Pac ket Interfac e b oard  and  
    traverse various hard ware c omp onents to sp ec ific  end p oints. The hard ware 
    c omp onents involved  on the forward  and  reverse routes c an b e d ifferent, 
    d ep end ing  upon the c onfig uration and  switc h administration. Various types of 
    links are defined  b y their end p oints:
    EAL Exp ansion Arc hang el Link terminating  at an Exp ansion Interface b oard . 
    This link c arries CCMS messag es.
    INL Indirect Neig hbor Link terminating  at a Switc h Nod e Interface b oard
    PACL PNC ATM Control Link terminating  at a PNC ATM EI b oard . This link carries 
    ATM sig naling  command s from CaPro to the remote TN2238 (ATM-EI) 
    boards.
    PGC Packet Gateway Call-Control Link terminating  at a Pac ket Gateway b oard
    PRI ISDN PRI D-Channel Link terminating  at a Universal DS1 b oard
    RSCL Remote Soc ket Control Link terminating  at a C-LAN b oard
    RSL Remote Soc ket Link teminating  at a C-LAN board
    SAP System (Ac c ess) Port Link terminating  at a Packet Data p ort
    X.25 BX.25 Link terminating  at a Pac ket Gateway p ort 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Troubleshooting  an Upgrade 
    B-7 Troubleshooting Guidelines 
    B
    The system links (SYS-LINK
    ) maintenanc e ob jec t rec ord s all errors enc ountered  
    on the links. Most of these events are not extraord inary unless they oc c ur with an 
    alarming  freq uenc y. The events are log g ed as they oc c ur, leaving  a “ trail”  to help  
    analyze ab normal b ehavior exhib ited  b y the end p oints attac hed  to the links or 
    the links themselves.
    When a link g oes down, an alarm is raised  immed iately. For EAL, INL, and  PACL 
    link typ es a MINOR alarm is raised ; for all other link typ es a WARNING alarm is 
    raised . Other alarming  c ond itions that d o not c ause the link to g o d own g et a 
    WARNING alarm, reg ard less of the link typ e.
    Troubleshooting Guidelines
    Before esc alating  a p rob lem, try the troubleshooting  p roc ed ures listed in this 
    ap p end ix. Also try the g eneral troub leshooting  p roc ed ures b elow. 
    1. Chec k the software c omp atib ility on the Software Release Letter. Be sure 
    the software that you are up g rad ing  
    from is c omp atib le with the software 
    that you are upg rad ing  
    to.
    2. Chec k the Release 8 software tap e (removab le med ia) for d efec ts. Typ e 
    test removable-media 
    UUCSS long
     and press En t e r, if you are using  R8 
    software. If you are using  R7 or p rior software, type test tape 
    UUCSS long
     
    and  p ress 
    En t e r. If the tap e (removab le med ia) has errors, rep lac e it.
    NOTE:
    Do not run the test removable-media short command
    , or the test 
    tape short command
    . This test c annot find  all of the b ad  sec tors 
    that may b e p resent on the tap e (removable med ia).
    3. If upg rad ing  from G3V4 and  earlier systems to a Release 8r, c hec k the 
    vintag e of the d isk d rive. The d isk d rive 
    must b e TN1657 Vintag e 4 or later.
    4. Always use the Software Release Letter that ac c omp anies the software 
    tap e (removable med ia). If the letter is not availab le, use the ap p rop riate 
    c hap ter in this b ook. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Troubleshooting  an Upgrade 
    B-8 Troubleshooting Guidelines 
    B
    Removable Media Troubleshooting Guidelines
    Use the following  g uid elines when troub leshooting  and  resolving removab le 
    media (R-MEDIA) problems.
    1.
    Avoid  saving  translations or announc ements on the b ac kup  removab le 
    d rive until all other removable med ia and Host Adap ter p rob lems have 
    b een resolved .
    If there is something  wrong  with the Mass Storag e System, an attemp t to 
    save translations or announc ements c ould  d estroy a g ood  c op y of the files 
    on the removab le med ia.
    2. In a system c onfigured  with d up lic ated  SPEs, the tests run on the standb y 
    removab le media c irc uit p ac k are id entic al to those run on the ac tive 
    removab le media c irc uit p ac k. Communic ations b etween the ac tive and  
    stand b y SPEs is provid ed  b y the DUPINT c irc uit p ac k for b oth the c ontrol 
    c hannel and  memory shad owing . Therefore, p rob lems with the DUPINT 
    c irc uit p ac k may affec t maintenanc e tests of the stand b y removab le med ia 
    circuit pack.
    3. Chec k the error log  for p ower related p rob lems and refer to the 
    maintenanc e d oc umentation on p ower.
    4. The data on the removable media will likely be destroyed if:
    nThe optic al d isk is removed  when the amb er LED on the removab le 
    med ia c irc uit p ac k is on.
    nThe removab le med ia c irc uit p ac k is removed  while the amber LED 
    on the removab le med ia c irc uit pac k is on.
    nPower is removed  from the removab le med ia while the amb er LED 
    on the removab le med ia c irc uit pac k is on. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Troubleshooting  an Upgrade 
    B-9 Troubleshooting Release 8 Upgrades 
    B
    Troubleshooting Release 8 Upgrades
    The sub sec tions to follow p resent sp ec ific  p roc edures for c ommon up g rad e 
    p rob lems, listed  b elow:
    nNo Translations After Upgrade
    nOne Side Upgrades, the Other Side Does Not (No Shadowing); Active Side 
    Has Correct R8 Load
    nRestore Disk Install or Restore Disk Full Fails
    nMessage Waiting Lamps On (After Removing an EPN)
    nTone Clock Does Not Function in New EPN
    nTranslation Corruption Detected
    nUnsuccessful Translation Read on System Restart (If Upgrading 
    From Pre-R7.1)
    nSoftware Incompatibility
    nRe-install the ISDN-PRI Links (Only for Failed Upgrades)
    No Translations After Upgrade
    This problem usually means that the save translation
     c ommand , p erformed  
    d uring the up g rad e, was not suc c essful. To rec over:
    1. Install the b ac kup  tap e (removab le med ia) into the tap e (removab le 
    med ia) d rive. This tap e (removab le med ia) must c ontain the orig inal 
    translations b efore the up g rad e started .
    2. Verify that the software is Release 8 and  that shad owing  is up .
    3. Cop y the translations from the b ac kup  tap e (removab le med ia) to the d isk. 
    Ty p e  copy translation disk both
     and p ress 
    En t e r. This c op ies the 
    translations from tape (removab le med ia) to disk and  takes about 30 
    minutes. 
    4. Type reset system 3
     and p ress 
    En t e r. 
    5. When the reb oot is finished , the system should  c ontain all of the 
    translations from the b ac kup  tap e (removab le med ia).  
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Troubleshooting  an Upgrade 
    B-10 Troubleshooting Release 8 Upgrades 
    B
    One Side Upgrades, the Other Side Does Not (No 
    Shadowing); Active Side Has Correct R8 Load
    This p rob lem ind ic ates that the software version on the standb y sid e is inc orrec t.
    1.Perform a “ hot-swap ”  of the d isk d rives (move the stand b y d isk to the 
    active sid e and  vic e versa).
    2. Insert the Release 8 software removab le med ia into the ac tive op tic al d isk 
    drive.
    3. Type list configure software
     and  press 
    En t e r to verify the removab le 
    med ia c ontains the req uired  Release 8 software.
    4. If the software version on the removab le med ia is inc orrec t, typ e restore 
    disk full active
     and p ress 
    En t e r. This c op ies the entire b ac kup  removab le 
    med ia to d isk and  takes ab out 30 minutes. Do not use the “ restore d isk 
    install”  c ommand .
    5. Perform a “ hot-swap ”  of the d isk d rives (move the stand b y d isk to the 
    active sid e and  vic e versa).
    6. Perform a power-down reset on the standby side 
    only. Disc onnec t the 
    p ower c ord s (first from the left sid e and  then the right sid e) from the p ower 
    su p p lie s o n  b o t h  s id e s o f  t h e  s t a n d b y  SPE.
    Restore Disk Install or Restore Disk Full Fails
    This p rob lem assumes that an MSS error was enc ountered, a restore disk full 
    failed, or a restore d isk install failed .
    1. This usually ind ic ates that a b ad  removab le med ia was used . To verify:
    a. Insert the susp ec t removab le med ia into the removab le med ia 
    drive.
    b. Type test tape 
    UUCSS long
     and press En te r.
    NOTE:
    Do not run the “ test tap e short”  c ommand . The short test 
    c annot find  all of the b ad  sec tors that may b e p resent on the 
    removable media.
    c . If the removab le med ia has errors, rep lac e it. 
    2. Insert a good Release 8 software removable media into the removable 
    media drive.
    3. Test the removab le med ia b efore starting  the upg rad e. Typ e test 
    removable-media 
    UUCSS long
     and  p ress En te r, if you are using  R8 
    software. If you are using  R7 or earlier software, typ e test tape 
    UUCSS 
    long
     and  p ress 
    En t e r.
    NOTE:
    Do not run the test removable-media short command
    , or the test 
    tape short command
    . The short test c annot find  all of the b ad  
    sec tors that may b e p resent on the tap e (removab le med ia). 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual