Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Troubleshooting an Upgrade B-1 B DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 B Troubleshooting an Upgrade This ap pend ix p rovid es information to c orrec t some p rob lems when upg rad ing a system. The information in this app end ix is a c omp ilation of the most c ommonly rep orted troub les rec eived b y Tier 4 Sup p ort at Luc ent Tec hnolog ies. For g eneral information on troub leshooting assoc iated with maintenanc e p roc ed ures, see one of the following referenc es: nChapter 5, Alarms, Errors and Troub leshooting , of the Release 8.2, Maintenanc e for R8r manual This ap p end ix may b e up d ated with new information at eac h p roduc t/d oc ument release. If you have troub leshooting or error rec overy information that you think would b e valuab le to other tec hnic ians, p lease FAX your c omments to us at 1-303-538-1741 (United States). This ap p end ix is org anized into three main sec tions, as d esc rib ed b elow: nNew for Release 8 – p rovid es information on introd uc tions for Release 8 that might result in upgrade problems nTroubleshooting Guidelines – provid es g eneral p roc ed ures to try b efore esc alating a p rob lem nTroubleshooting Release 8 Upgrades – p rovid es spec ific troub leshooting p roc ed ures for c ommon up g rad e p rob lems
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Troubleshooting an Upgrade B-2 New for Release 8 B New for Release 8 nATM PNC Duplication (ATM PNC-DUP) nATM Expansion Interface (ATM-EI) nMass Storage System nControl LAN (C-LAN) nControl LAN (C-LAN) nSystem Links (SYS-LINK) ATM PNC Duplication (ATM PNC-DUP) The PNC-DUP maintenanc e ob jec t trac ks the health of the ac tive and stand b y PNCs, c ontrols p lanned and sp ontaneous interc hanges, and manag es related func tions suc h as d oub le c all refresh and unrefresh, antithrashing, and so on. The main resp onsib ility of PNC-DUP is to rec over the system to full servic e in the event of a fault. In the event of multip le faults, PNC-DUP d oes its best to maximize servic e c ontinuity. In systems with the Critic al Reliability op tion, the following c omp onents, whic h tog ether c omp rise the Port Network Connec tivity (PNC), are d up lic ated : nATM-Exp ansion Interfac e (ATM-EI) c irc uit p ac ks in the port networks (PNs) nFiber-optic c ab les c onnec ting the ab ove c irc uit pac ks to the ATM Switc h Interfac e Mod ules nATM Sw i t c h Althoug h not p art of the PNC, Tone-Cloc k c irc uit p ac ks are also d up lic ated in eac h PN. All systems have one Proc essor Port Network (PPN). ATM PNC systems c an have up to 43 EPNs. PNC d up lic ation arc hitec ture utilizes an ac tive/stand b y d up lic ation sc heme in whic h one c omplete set of PNC c omp onents sup p orts c all p roc essing , while the d up lic ate PNC is held in reserve. All c alls on the ac tive PNC are simultaneously set up , or shad owed , on the stand b y PNC in ord er for it to b e c apab le of instantly assuming ac tive status when nec essary, allowing for interc hang es without servic e d isrup tion (in the c ase of sing le faults). PNC d up lic ation d oes not introd uc e any ad ditional typ es of hard ware or hard ware faults, and there are no tests assoc iated with the PNC-DUP MO. Instead , its error log entries c ontain useful information ab out the oc c urrenc e and c auses of interc hang es in ord er to fac ilitate d iag nosis of p roblems, whic h c an then b e ad dressed b y using the d oc umentation for the ind ivid ual maintenanc e ob ject involved.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Troubleshooting an Upgrade B-3 New for Release 8 B The following PNC d up lic ation-related c ommand s and their outp ut sc reens are fully d esc rib ed in Chap ter 8, Maintenanc e Command s, of the DEFINITY ECS Release 8 Maintenanc e for Release R8r b ook. The assoc iated PNC-DUP maintenanc e ob jec t is found in Chap ter 9 of the same referenc e. ATM Expansion Interface (ATM-EI) The ATM-EI maintenanc e ob jec t c overs the ATM c irc uit p ac k administered as an ATM-Port Network Connec tivity (PNC) Exp ansion Interfac e (ATM-EI). The ATM-EI p rovid es PNC b etween a DEFINTY PPN and all the EPNs throug h the ATM switc h. The circuit packs listed below are ATM-EI boards if they are ad ministered to serve the ATM Port Network Connec tivity (ATM-PNC) for DEFINITY . Mass Storage System The Mass Storag e System (MSS) p rovid es non-volatile storag e for system software, translation d ata, announc ement d ata and p rog ram up d ate d ata. As shown in the fig ure b elow, the MSS c onsists of a Host Ad ap ter c irc uit on the U N 3 3 2 C M SS- N e t w o r k C o n t ro l c i rc u it p a c k ( M SSN ET) , a Sm a l l C o m p u t e r Sy st e m Interfac e (SCSI) b us, a TN2211 Op tic al Drive c irc uit p ac k or a TN1656 Tap e Drive c irc uit p ac k, and the TN1657 Disk Drive c irc uit pac k. The Disk Drive ac ts as the p rimary storag e d evic e. The TN2211 Op tic al Drive or TN1656 Tap e Drive serves as a b ac kup d evic e and as a removab le med ium for system d ata.status pnc Disp lays information ab out the op erational status of b oth PNCs inc lud ing state of health, alarms, b usyouts and loc ks, and so on. reset pnc interchangeUsed to initiate a demand PNC interc hang e. If the stand by is healthy (state of health ind exes all zero), there is no effect on service. Otherwise, calls may be dropped. set pnc Used to lock or unlock the active PNC, preventing interc hang es. It d oes not interfere with d oub le c all setup . busyout pnc Removes the stand b y PNC from servic e. Circuit pack FiberEcho cancellation TN2305B Multi mod e Y TN2306B Sing le mode Y Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Troubleshooting an Upgrade B-4 New for Release 8 B Troub leshooting details for the Mass Storag e System may b e found und er the R-MEDIA maintenanc e ob jec t in Chap ter 9, Maintenanc e Ob jec t Rep air Proc ed ures, of the Release 8.2, Maintenanc e for R8r manual. Ad d itional related maintenanc e ob jec ts assoc iated with the Mass Storag e System inc lud e STO-DATA , DISK , and H-ADAPTR . Figure B-1. TN2211 faceplate The system is usually b ooted from the b oot imag e stored on d isk. The save translation and save announcements commands save to d isk the memory-resid ent translation d ata and TN750-resid ent announc ement data, resp ectively. The backup disk c ommand c op ies d ata from the d isk to the removab le med ia for b ac kup storag e. The restore disk c ommand c op ies d ata f ro m t h e re m o v a b l e m e d ia b a c k t o d i sk . A ll M SS c o m p o n e n t s re s id e in t h e SPE, o r PPN c o n t ro l c a r ri e r ( c a r r ie r A f o r a s im p le x SPE, c a rr i e r s A a n d B f o r a duplicated SPE). The removab le media c irc uit p ac k c ontains SCSI b us terminators, a -48V to + 12V p ower c onverter, an industry stand ard SCSI-b ased removab le med ia d rive, and interfac e c irc uitry to the p rivate b us to c ontrol the LEDs, d etec t the p resenc e of the c irc uit p ac k, and id entify the vintag e of the hard ware. Red Green Yellow fpdf2211 KLC 010600TN2211 OPTICAL DRIVE
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Troubleshooting an Upgrade B-5 New for Release 8 B A -48V to + 12V c onverter c irc uit on the TN2211 Op tic al Drive c irc uit p ac k p rovid es p ower for b oth the Op tic al Drive and the Disk Drive. The p resenc e of + 12V on these c irc uit p ac ks is monitored sep arately b y maintenanc e software so that a failure of the + 12V c onverter on the Removab le Med ia c irc uit pac k c an b e id entified or ruled out as the sourc e of the p rob lem when the Disk Drive loses + 12V p ower. The Host Ad ap ter c irc uit p ac k, Removab le Med ia Drive c irc uit p ac k, and Disk c irc uit p ac k are treated as sep arate, b ut related , maintenanc e ob jec ts (H-ADAPTR, R-MEDIA, and DISK). Sinc e the Disk c irc uit p ac k is c ontrolled b y SCSI c ommand s whic h are g enerated b y the Host Ad apter, p rob lems with the Host Ad ap ter c an p revent c ommunic ations with the Disk. Whenever the Host Ad apter is taken out of servic e b y the busy-out host-adapter c ommand , or d ue to failure of a c ritic al Host Ad apter test, the Removab le Med ia (R-MEDIA) and Disk (DISK) maintenanc e ob jec ts are also p lac ed in a maintenanc e b usyout state. Figure B-2. Mass Storage System interactions Switch processorSystem memory System bus Host adapter MSSNET circuit packSCSI bus Private bus Disk circuit packDisk driveTape driveOptical drive Disk TapeOptical disk Tape circuit packOptical drive circuit pack +12V SPE Mass storage system cydfmass LJK 092999
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Troubleshooting an Upgrade B-6 New for Release 8 B Control LAN (C-LAN) The TN799 Control LAN (C-LAN) p ac ket p ort c irc uit p ac k p rovid es TCP/IP c onnec tion to ad junc ts app lic ations suc h as CMS, Intuity, and DCS Networking . The C-LAN c irc uit p ac k has 1 10b aseT Ethernet c onnec tion and up to 16 DS0 p hy si c al in t er f ac es f o r PPP c o nne c t io ns . Put t i ng mu lt i p le C -LAN c irc ui t p ac k s int o a -system g ives ad d itional TCP/IP c ap ac ity. In ad d ition to the TCP/IP func tionality, CLAN extends the ISDN capabilities for csi models by providing Packet bus ac c ess. A re m o t e s o c ke t c o n t ro l l in k ( RSC L ) li n k s t h e C - L AN a n d t h e SPE t o p a ss c a ll c ontrol and other management information. Sinc e one link serves all the p orts on the c irc uit p ac k, maintenanc e of the RSCL is p art of the C-LAN c irc uit p ac k maintenanc e. The C-LAN TN799 c irc uit p ac k c omb ines the func tions of the PGATE and PI c irc uit p ac ks into one c irc uit p ac k. The PGATE or PI c an b e used with the C-LAN to c reate an X.25-to-TCP/IP b rid g e for ad junc t and DCS c onnec tivity. Maintenanc e ob jec ts assoc iated und er the Control LAN area inc lud e CLAN-BD (Control LAN Circ uit Pac k), ETH-PT (Control LAN Ethernet), and PPP-PT (Control LAN Pac ket/Port). System Links (SYS-LINK) System Links are pac ket links that orig inate at the Pac ket Interfac e b oard and traverse various hard ware c omp onents to sp ec ific end p oints. The hard ware c omp onents involved on the forward and reverse routes c an b e d ifferent, d ep end ing upon the c onfig uration and switc h administration. Various types of links are defined b y their end p oints: EAL Exp ansion Arc hang el Link terminating at an Exp ansion Interface b oard . This link c arries CCMS messag es. INL Indirect Neig hbor Link terminating at a Switc h Nod e Interface b oard PACL PNC ATM Control Link terminating at a PNC ATM EI b oard . This link carries ATM sig naling command s from CaPro to the remote TN2238 (ATM-EI) boards. PGC Packet Gateway Call-Control Link terminating at a Pac ket Gateway b oard PRI ISDN PRI D-Channel Link terminating at a Universal DS1 b oard RSCL Remote Soc ket Control Link terminating at a C-LAN b oard RSL Remote Soc ket Link teminating at a C-LAN board SAP System (Ac c ess) Port Link terminating at a Packet Data p ort X.25 BX.25 Link terminating at a Pac ket Gateway p ort
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Troubleshooting an Upgrade B-7 Troubleshooting Guidelines B The system links (SYS-LINK ) maintenanc e ob jec t rec ord s all errors enc ountered on the links. Most of these events are not extraord inary unless they oc c ur with an alarming freq uenc y. The events are log g ed as they oc c ur, leaving a “ trail” to help analyze ab normal b ehavior exhib ited b y the end p oints attac hed to the links or the links themselves. When a link g oes down, an alarm is raised immed iately. For EAL, INL, and PACL link typ es a MINOR alarm is raised ; for all other link typ es a WARNING alarm is raised . Other alarming c ond itions that d o not c ause the link to g o d own g et a WARNING alarm, reg ard less of the link typ e. Troubleshooting Guidelines Before esc alating a p rob lem, try the troubleshooting p roc ed ures listed in this ap p end ix. Also try the g eneral troub leshooting p roc ed ures b elow. 1. Chec k the software c omp atib ility on the Software Release Letter. Be sure the software that you are up g rad ing from is c omp atib le with the software that you are upg rad ing to. 2. Chec k the Release 8 software tap e (removab le med ia) for d efec ts. Typ e test removable-media UUCSS long and press En t e r, if you are using R8 software. If you are using R7 or p rior software, type test tape UUCSS long and p ress En t e r. If the tap e (removab le med ia) has errors, rep lac e it. NOTE: Do not run the test removable-media short command , or the test tape short command . This test c annot find all of the b ad sec tors that may b e p resent on the tap e (removable med ia). 3. If upg rad ing from G3V4 and earlier systems to a Release 8r, c hec k the vintag e of the d isk d rive. The d isk d rive must b e TN1657 Vintag e 4 or later. 4. Always use the Software Release Letter that ac c omp anies the software tap e (removable med ia). If the letter is not availab le, use the ap p rop riate c hap ter in this b ook.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Troubleshooting an Upgrade B-8 Troubleshooting Guidelines B Removable Media Troubleshooting Guidelines Use the following g uid elines when troub leshooting and resolving removab le media (R-MEDIA) problems. 1. Avoid saving translations or announc ements on the b ac kup removab le d rive until all other removable med ia and Host Adap ter p rob lems have b een resolved . If there is something wrong with the Mass Storag e System, an attemp t to save translations or announc ements c ould d estroy a g ood c op y of the files on the removab le med ia. 2. In a system c onfigured with d up lic ated SPEs, the tests run on the standb y removab le media c irc uit p ac k are id entic al to those run on the ac tive removab le media c irc uit p ac k. Communic ations b etween the ac tive and stand b y SPEs is provid ed b y the DUPINT c irc uit p ac k for b oth the c ontrol c hannel and memory shad owing . Therefore, p rob lems with the DUPINT c irc uit p ac k may affec t maintenanc e tests of the stand b y removab le med ia circuit pack. 3. Chec k the error log for p ower related p rob lems and refer to the maintenanc e d oc umentation on p ower. 4. The data on the removable media will likely be destroyed if: nThe optic al d isk is removed when the amb er LED on the removab le med ia c irc uit p ac k is on. nThe removab le med ia c irc uit p ac k is removed while the amber LED on the removab le med ia c irc uit pac k is on. nPower is removed from the removab le med ia while the amb er LED on the removab le med ia c irc uit pac k is on.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Troubleshooting an Upgrade B-9 Troubleshooting Release 8 Upgrades B Troubleshooting Release 8 Upgrades The sub sec tions to follow p resent sp ec ific p roc edures for c ommon up g rad e p rob lems, listed b elow: nNo Translations After Upgrade nOne Side Upgrades, the Other Side Does Not (No Shadowing); Active Side Has Correct R8 Load nRestore Disk Install or Restore Disk Full Fails nMessage Waiting Lamps On (After Removing an EPN) nTone Clock Does Not Function in New EPN nTranslation Corruption Detected nUnsuccessful Translation Read on System Restart (If Upgrading From Pre-R7.1) nSoftware Incompatibility nRe-install the ISDN-PRI Links (Only for Failed Upgrades) No Translations After Upgrade This problem usually means that the save translation c ommand , p erformed d uring the up g rad e, was not suc c essful. To rec over: 1. Install the b ac kup tap e (removab le med ia) into the tap e (removab le med ia) d rive. This tap e (removab le med ia) must c ontain the orig inal translations b efore the up g rad e started . 2. Verify that the software is Release 8 and that shad owing is up . 3. Cop y the translations from the b ac kup tap e (removab le med ia) to the d isk. Ty p e copy translation disk both and p ress En t e r. This c op ies the translations from tape (removab le med ia) to disk and takes about 30 minutes. 4. Type reset system 3 and p ress En t e r. 5. When the reb oot is finished , the system should c ontain all of the translations from the b ac kup tap e (removab le med ia).
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Troubleshooting an Upgrade B-10 Troubleshooting Release 8 Upgrades B One Side Upgrades, the Other Side Does Not (No Shadowing); Active Side Has Correct R8 Load This p rob lem ind ic ates that the software version on the standb y sid e is inc orrec t. 1.Perform a “ hot-swap ” of the d isk d rives (move the stand b y d isk to the active sid e and vic e versa). 2. Insert the Release 8 software removab le med ia into the ac tive op tic al d isk drive. 3. Type list configure software and press En t e r to verify the removab le med ia c ontains the req uired Release 8 software. 4. If the software version on the removab le med ia is inc orrec t, typ e restore disk full active and p ress En t e r. This c op ies the entire b ac kup removab le med ia to d isk and takes ab out 30 minutes. Do not use the “ restore d isk install” c ommand . 5. Perform a “ hot-swap ” of the d isk d rives (move the stand b y d isk to the active sid e and vic e versa). 6. Perform a power-down reset on the standby side only. Disc onnec t the p ower c ord s (first from the left sid e and then the right sid e) from the p ower su p p lie s o n b o t h s id e s o f t h e s t a n d b y SPE. Restore Disk Install or Restore Disk Full Fails This p rob lem assumes that an MSS error was enc ountered, a restore disk full failed, or a restore d isk install failed . 1. This usually ind ic ates that a b ad removab le med ia was used . To verify: a. Insert the susp ec t removab le med ia into the removab le med ia drive. b. Type test tape UUCSS long and press En te r. NOTE: Do not run the “ test tap e short” c ommand . The short test c annot find all of the b ad sec tors that may b e p resent on the removable media. c . If the removab le med ia has errors, rep lac e it. 2. Insert a good Release 8 software removable media into the removable media drive. 3. Test the removab le med ia b efore starting the upg rad e. Typ e test removable-media UUCSS long and p ress En te r, if you are using R8 software. If you are using R7 or earlier software, typ e test tape UUCSS long and p ress En t e r. NOTE: Do not run the test removable-media short command , or the test tape short command . The short test c annot find all of the b ad sec tors that may b e p resent on the tap e (removab le med ia).