Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 G3vs with Intel 386 or Risc Processor to R8r 4-13 Install the Release 8r Cabinets 4 2. Type the appropriate start and stop information in the Change Day , Month , Date , Time , and Increment (for example, 1:00 eq uals one hour) field s for eac h rule. NOTE: You c an c hang e any rule exc ep t rule 0 (zero). You c annot delete a d aylig ht saving s rule if it is in use on either the Loc ations or Date and Ti m e s c re e n s . 3. Press En t e r. Set Date and Time 1. Type set time and press En t e r. 2. Verify the sc reen d isp lays the Date and Time sc reen. See Screen 4-1 . The c ursor is p ositioned on the Day of the Week: field . . Screen 4-1. Typical Date and Time Screen DATE AND TIME DATE Day of the Week: Tuesday Month: FebruaryDay of the Month: 8 Year: 2000 TIME Hour: 20 Minute: 30Second: XX Type: standardDaylight Savings Rule: 0
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 G3vs with Intel 386 or Risc Processor to R8r 4-14 Install the Release 8r Cabinets 4 3. Typ e the d ay of the week in Eng lish (Sunday throug h Saturd ay). See Table 4-2 for English day of the week names. 4. The c ursor is p ositioned on the Month: field . Typ e the c urrent month in Eng lish (January throug h Dec emb er). See Table 4-3 for Eng lish month names. After the month is entered, p ress Ta b to move to next field . Table 4-2. English Day of the Week Names Day Number Day Name 1Sunday 2 Mond ay 3Tuesday 4 Wed nesd ay 5Thursday 6Friday 7Saturday Table 4-3. English Month Names Month Number Month Name 1 January 2February 3March 4April 5May 6June 7July 8August 9 Sep temb er 10 Oc tob er 11 November 12 Dec emb er
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 G3vs with Intel 386 or Risc Processor to R8r 4-15 Install the Release 8r Cabinets 4 5. The c ursor is p ositioned on the Day of the Month: field . Typ e the d ay of month (1 through 31) and p ress Ta b to move to the next field. 6. The c ursor is p ositioned on the Year: field . Typ e the c urrent year and p ress TA B to move to the next field . 7. The c ursor is p ositioned on the Hour: field . Typ e the c urrent hour for a 24-hour c loc k. Press Ta b to move to the next field . 8. The c ursor is p ositioned on the Minute: field . Type c urrent minute (0 throug h 59). Sec ond s c annot b e set. 9. Type standard or daylight savings in the Type field . 10. Typ e the rule (numb er) in the Daylight Savings Rule field. 11. Press En t e r when the information is c orrec t. 12. Typ e display time and press En te r to verify d ate/time d ata. Re-Record Announcements (TN750/B) 1. Refer to DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e to rec ord announc ements. NOTE: The TN750C Announc ement c irc uit p ac k stores announc ements in non-volatile memory; re-rec ord ing the announc ements is not need ed . Copy Announcements (TN750/B) 1. If the system c ontains a TN750/B Announc ement c irc uit p ac k, type display announcements and p ress En t e r. 2. If ad ministered rec orded announc ements are listed , typ e copy announce and p ress En t e r. NOTE: The TN750C Announc ement c irc uit p ac k stores announc ements in non-volatile memory; saving the announc ements is not need ed .
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 G3vs with Intel 386 or Risc Processor to R8r 4-16 Upgrade Completion 4 Upgrade Completion Install Remaining Hardware and Administer the System 1. If the p resent system was removed to make room for the Release 8r c ab inet, skip to Step 3. 2. If the Release 8r c ab inet was installed while the p resent system is in servic e, return to ‘‘Remove the Present System’’ on page 4-7 . Return to this sec tion when finished . 3. Connec t all new and reusable I/O c ab les to the Release 8r c ab inet. Cross-c onnec t at the MDF as req uired . 4. Remove all reusab le c irc uit pac ks from the p resent system and install into the Release 8r c ab inet. Install any new c irc uit pac ks into the Release 8r c ab inet. 5. Install fib er op tic c ab les and ad minister the fib er links as need ed . Refer to DEFINITY Enterp rise Communic ations Server Release 8 Installation and Test for Multic arrier Cabinets . 6. Ad minister any new translations, as req uired . Enable TTI 1. Type change system-parameters features and press En t e r. 2. On the sec ond sc reen, set the Enabled? field to y to ac tivate the TTI feature. Check Link Status 1. Type display communication-interface links and press En te r. Compare it with the earlier status. 2. Type status link number and p ress En t e r. Rep eat this step for eac h link. Enable Scheduled Maintenance 1. Type change system-parameters maintenance and press En t e r. Use this sc reen to enable sc hed uled d aily maintenanc e. Resolve Alarms 1. Examine the alarm log . Resolve any alarms using DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8r .
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 G3vs with Intel 386 or Risc Processor to R8r 4-17 Upgrade Completion 4 Enable Customer Options and Alarm Origination to INADS 1. Get the DOSS order number of the upgrade from the project manager and ask the reg ional Customer Software Ad ministration to c omp lete the step s in the shad ed b ox. See ‘‘Where to Call for Tec hnic al Sup p ort’’ on p ag e -xx for telep hone numb ers. NOTE: As p art of the system reg istration p roc ess, the INADS Datab ase Ad ministrator enab les Alarm Orig ination. 2. When ad ministration is c omp leted , log in as craft at the Login: prompt. Administration: 1. Log in as init at the Login: prompt. 2. Type change system-parameters customer-options and press En te r to verify that the c ustomer op tions are p roperly set. 3. Go to sc reen 6, QSIG Op tional Features, and set the Basic Call Setup field to y if the customer was using Supplementary Services Protoc ol b or d on an ISDN-PRI trunk g roup b efore the up g rad e. 4. Type change system-parameters offer-options and p ress En te r. 5. Set the Activate Offer field to y and press Ta b. A warning messag e lets you know the offer c ateg ory along with the mod el to d etermine the system c ap ac ities (limits) and allowab le hard ware. 6. Press En t e r to effec t the c hang es. 7. When d one, c ontac t the field tec hnic ian. 8. Contac t the req uester when d one.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 G3vs with Intel 386 or Risc Processor to R8r 4-18 Upgrade Completion 4 Save Translations 1. Type save translation and press En te r to g et up g rad ed translations onto d isk. If the translations were c orrup ted d uring the up g rad e, the following error message displays when logging in: !WARNING: Translation c orrup tion d etec ted ; c all Luc ent Tec hnolog ies d istrib utor immed iately. NOTE: Th e save translation c ommand c annot func tion if the translation c orruption messag e ap p ears. Back Up Disk 1. Type backup disk and p ress En t e r to backup all changed files. 2. Type test stored-data long and press En t e r. This instructs the system to verify the c onsistenc y of the MSS files (on the d isk and removab le med ia). Return Replaced Equipment 1. Return rep lac ed eq uip ment to Luc ent Tec hnolog ies ac c ord ing to the req uirements outlined in: BCS/Material Log istic s, MSL/Attend ed Stoc king Loc ations Method s and Proc ed ures for Basic Material Returns
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 G3vs with Intel 386 or Risc Processor to R8r 4-19 DEFINITY AUDIX Power Procedures 4 DEFINITY AUDIX Power Procedures Power Down the AUDIX System A yellow c aution stic ker on the system’s power unit notifies tec hnic ians to shut d own the DEFINITY AUDIX System p rior to p owering d own the system. 1. Log into the AUDIX System as craft . 2. Type reset system shutdown . Press En te r onc e. NOTE: Do not p ress En t e r again. This will forc e the AUDIX to shutd own immed iately, d rop p ing all ac tive c alls on the AUDIX. 3. The “ SHUTDOWN Comp leted ” messag e ap p ears when the AUDIX is suc c essfully shutd own. This takes ab out 2 minutes. 4. The AUDIX System can now b e removed for service. Power Up the AUDIX System nIf the AUDIX was removed from the c ab inet: 1. Re-install the AUDIX and allow it to b oot up automatic ally. 2. Check for AUDIX System errors. nIf the AUDIX remained in the c ab inet b ut p ower was removed from the c ab inet: 1. Power up the c ab inet. The AUDIX reb oots automatic ally. 2. Check for AUDIX System errors. nIf the AUDIX remained in the c ab inet and the c ab inet was not powered down: 1. At the AUDIX c onsole, hold the crtl key and typ e cc . 2. Type 5 at the p romp t. In ab out 2 minutes, the AUDIX b oots up . 3. When the system initialization is c omp lete, log in as craft . 4. Check for AUDIX System errors.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 G3vs with Intel 386 or Risc Processor to R8r 4-20 DEFINITY AUDIX Power Procedures 4
Multicarrier G2 Universal Module to R8r EPN 5-1 Single-Mode Fiber Attenuators 5 DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 5 Multicarrier G2 Universal Module to R8r EPN This chapter provides the information necessary to upgrade a DEFINITY G2 universal mod ule to a multic arrier EPN of a R8r system. DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e lists Release 8 features and func tions, and provid es the c ommand s, p roc ed ures, and forms to initialize and ad minister the system. Single-Mode Fiber Attenuators Attenuators may b e req uired when using sing le-mod e fib er. See the tab le b elow. A d ifferent value attenuator may b e req uired even thoug h the fib er sp an is b etween the same 2 c ab inets (loc al and remote c ab inet). Refer to DEFINITY Enterp rise Communic ations Server Release 8 Installation and Test for Multic arrier Cab inets for detailed fib er attenuator information. 106060718 5 d B attenuator 2 for eac h fib er c onnec tion 106060734 10 dB attenuator 2 for eac h fib er c onnec tion 106061021 15 dB attenuator 2 for eac h fib er c onnec tion
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-2 Read This First 5 Read This First Service Interruption The up g rad e p roc ess req uires a servic e interruption of ab out 40 minutes. Coord inate this servic e interrup tion with the c ustomer and the loc al ac c ount team. Call Management System (CMS) The CMS link is dropped and restarted during the upgrade. This causes CMS d ata to b e lost. This d ata loss c an be minimized if the up g rad e is p erformed just after the last CMS measurement interval. All measurement d ata is lost d uring the up g rad e (inc lud ing BCMS). If need ed , the reports may be printed before the upgrade begins. CMS c ould ab ort the p roc essing of a c all if a measured trunk that was part of the c onferenc e d rop p ed off the c all b efore the end of the c all. Customers exp erienc ing this symp tom and who are running R3V4 CMS should upd ate to r3v4ao.e or hig her. Preventing Translation Errors When instruc ted in this c hap ter, p erform the save translation c ommand . Afterward , c hec k for translation errors b efore p roc eed ing with the up g rad e. NOTE: Be sure that the translations g et saved without errors b efore c ontinuing with any up g rad e. If errors are d etec ted , refer to ‘‘No Translations After Upgrade’’ in Appendix B, ‘‘Troubleshooting an Upgrade’’ to c orrec t the p rob lem. Do not c ontinue with the up g rad e until the errors are c orrec ted . Contact Network Technicians Contac t the tec hnic ian for eac h p ub lic and p rivate network ac c essed b y the system b efore the upg rad e b eg ins. Otherwise, if these tec hnic ians are not aware of the servic e interrup tion c aused b y the up g rad e, it is possible that network-ac c ess trunk fac ilities will b e b usied out at the far end . Communication Between Equipment Rooms For an up g rad e where some of the eq uip ment resid es at a remote loc ation, the up g rad e ac tivity is muc h easier if temp orary c ommunic ation is established b etween the equip ment rooms.