    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    G3vs with Intel 386 or Risc Processor to R8r 
    4-13 Install the Release 8r Cabinets 
    4
    2. Type the appropriate start and stop information in the Change Day
    , 
    Month
    , Date
    , Time
    , and  Increment
     (for example, 1:00
     eq uals one hour) 
    field s for eac h rule. 
    NOTE:
    You c an c hang e any rule exc ep t rule 0 (zero). You c annot delete a 
    d aylig ht saving s rule if it is in use on either the Loc ations or Date and 
    Ti m e  s c re e n s .
    3. Press 
    En t e r.
    Set Date and Time
    1. Type set time 
    and 
    press En t e r.
    2. Verify the sc reen d isp lays the Date and Time sc reen. See Screen 4-1
    . The 
    c ursor is p ositioned  on the Day of the Week:
     field .
    .
    Screen 4-1. Typical Date and Time Screen
     
                               DATE AND TIME
    DATE
     Day of the Week: Tuesday
    Month: FebruaryDay of the Month: 8 Year: 2000
    TIME
    Hour: 20 Minute: 30Second: XX Type: standardDaylight Savings Rule: 0 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    G3vs with Intel 386 or Risc Processor to R8r 
    4-14 Install the Release 8r Cabinets 
    4
    3. Typ e the d ay of the week in Eng lish (Sunday throug h Saturd ay). See 
    Table 4-2
     for English day of the week names.
    4. The c ursor is p ositioned  on the Month:
     field . Typ e the c urrent month in 
    Eng lish (January throug h Dec emb er). See Table 4-3
     for Eng lish month 
    names. After the month is entered, p ress 
    Ta b to move to next field .
    Table 4-2. English Day of the Week Names
    Day Number Day Name
    1Sunday
    2 Mond ay
    3Tuesday
    4 Wed nesd ay
    5Thursday
    6Friday
    7Saturday
    Table 4-3. English Month Names
    Month Number Month Name
    1 January
    2February
    3March
    4April
    5May
    6June
    7July
    8August
    9 Sep temb er
    10 Oc tob er
    11 November
    12 Dec emb er 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    G3vs with Intel 386 or Risc Processor to R8r 
    4-15 Install the Release 8r Cabinets 
    4
    5. The c ursor is p ositioned  on the Day of the Month:
     field . Typ e the d ay 
    of month (1 through 31) and  p ress 
    Ta b to move to the next field.
    6. The c ursor is p ositioned  on the Year:
     field . Typ e the c urrent year and  
    p ress 
    TA B to move to the next field .
    7. The c ursor is p ositioned  on the Hour:
     field . Typ e the c urrent hour for a 
    24-hour c loc k. Press
     Ta b to move to the next field .
    8. The c ursor is p ositioned  on the Minute:
     field . Type c urrent minute (0 
    throug h 59). Sec ond s c annot b e set.
    9. Type standard
     or daylight savings
     in the Type
     field .
    10. Typ e the rule (numb er) in the Daylight Savings Rule
     field.
    11. Press 
    En t e r when the information is c orrec t.
    12. Typ e display time 
    and press 
    En te r  to verify d ate/time d ata.
    Re-Record Announcements (TN750/B)
    1. Refer to DEFINITY Enterp rise Communic ations Server Release 8 
    Ad ministrator’s Guid e
     to rec ord  announc ements.
    NOTE:
    The TN750C Announc ement c irc uit p ac k stores announc ements in 
    non-volatile memory; re-rec ord ing  the announc ements is not 
    need ed .
    Copy Announcements (TN750/B)
    1. If the system c ontains a TN750/B Announc ement c irc uit p ac k, type 
    display announcements
     and  p ress 
    En t e r.
    2. If ad ministered  rec orded  announc ements are listed , typ e copy announce 
    and  p ress 
    En t e r.
    NOTE:
    The TN750C Announc ement c irc uit p ac k stores announc ements in 
    non-volatile memory; saving  the announc ements is not need ed . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    G3vs with Intel 386 or Risc Processor to R8r 
    4-16 Upgrade Completion 
    4
    Upgrade Completion
    Install Remaining Hardware and Administer the 
    System
    1. If the p resent system was removed to make room for the Release 8r 
    c ab inet, skip  to Step  3.
    2. If the Release 8r c ab inet was installed  while the p resent system is in 
    servic e, return to ‘‘Remove the Present System’’ on page 4-7
    . Return to 
    this sec tion when finished .
    3. Connec t all new and  reusable I/O c ab les to the Release 8r c ab inet. 
    Cross-c onnec t at the MDF as req uired .
    4. Remove all reusab le c irc uit pac ks from the p resent system and  install into 
    the Release 8r c ab inet. Install any new c irc uit pac ks into the Release 8r 
    c ab inet.
    5. Install fib er op tic  c ab les and  ad minister the fib er links as need ed . Refer to 
    DEFINITY Enterp rise Communic ations Server Release 8 Installation and  
    Test for Multic arrier Cabinets
    .
    6. Ad minister any new translations, as req uired .
    Enable TTI
    1. Type change system-parameters features
     and press En t e r.
    2. On the sec ond  sc reen, set the Enabled?
     field  to y
     to ac tivate the TTI 
    feature.
    Check Link Status
    1. Type display communication-interface links
     and press En te r. Compare it 
    with the earlier status.
    2. Type status link
     
    number and  p ress En t e r. Rep eat this step  for eac h link.
    Enable Scheduled Maintenance
    1. Type change system-parameters maintenance
     and  press En t e r. Use this 
    sc reen to enable sc hed uled  d aily maintenanc e.
    Resolve Alarms
    1. Examine the alarm log . Resolve any alarms using  DEFINITY Enterp rise 
    Communic ations Server Release 8 Maintenanc e for R8r
    .  
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    G3vs with Intel 386 or Risc Processor to R8r 
    4-17 Upgrade Completion 
    4
    Enable Customer Options and Alarm Origination 
    to INADS
    1. Get the DOSS order number of the upgrade from the project manager and 
    ask the reg ional Customer Software Ad ministration to c omp lete the step s 
    in the shad ed  b ox. See ‘‘Where to Call for Tec hnic al Sup p ort’’ on p ag e -xx
     
    for telep hone numb ers.
    NOTE:
    As p art of the system reg istration p roc ess, the INADS Datab ase 
    Ad ministrator enab les Alarm Orig ination.
    2. When ad ministration is c omp leted , log  in as craft
     at the Login:
     prompt.
    Administration:
    1. Log in as init
     at the Login: 
    prompt.
    2. Type change system-parameters customer-options
     and press 
    En te r 
    to verify that the c ustomer op tions are p roperly set.
    3. Go to sc reen 6, QSIG Op tional Features, and  set the Basic Call 
    Setup 
    field  to y
     if the customer was using Supplementary Services 
    Protoc ol b  or d  on an ISDN-PRI trunk g roup  b efore the up g rad e.
    4. Type change system-parameters offer-options
     and  p ress 
    En te r.
    5. Set the Activate Offer
     field  to y 
    and press 
    Ta b. A warning  messag e 
    lets you know the offer c ateg ory along with the mod el to d etermine the 
    system c ap ac ities (limits) and  allowab le hard ware.
    6. Press 
    En t e r to effec t the c hang es.
    7. When d one, c ontac t the field  tec hnic ian.
    8. Contac t the req uester when d one. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    G3vs with Intel 386 or Risc Processor to R8r 
    4-18 Upgrade Completion 
    4
    Save Translations
    1. Type save translation
     and press En te r to g et up g rad ed  translations onto 
    d isk. If the translations were c orrup ted  d uring  the up g rad e, the following  
    error message displays when logging in:
    !WARNING:
    Translation c orrup tion d etec ted ; c all Luc ent Tec hnolog ies d istrib utor 
    immed iately.
    NOTE:
    Th e  save translation
     c ommand c annot func tion if the translation 
    c orruption messag e ap p ears.
    Back Up Disk
    1. Type backup disk
     and  p ress En t e r to backup all changed files.
    2. Type test stored-data long
     and press 
    En t e r. This instructs the system to 
    verify the c onsistenc y of the MSS files (on the d isk and  removab le med ia).
    Return Replaced Equipment
    1. Return rep lac ed  eq uip ment to Luc ent Tec hnolog ies ac c ord ing  to the 
    req uirements outlined  in:
    BCS/Material Log istic s, MSL/Attend ed  Stoc king  Loc ations
    Method s and Proc ed ures for Basic  Material Returns 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    G3vs with Intel 386 or Risc Processor to R8r 
    4-19 DEFINITY AUDIX Power Procedures 
    4
    DEFINITY AUDIX Power Procedures
    Power Down the AUDIX System
    A yellow c aution stic ker on the system’s power unit notifies tec hnic ians to shut 
    d own the DEFINITY AUDIX System p rior to p owering  d own the system.
    1. Log  into the AUDIX System as craft
    . 
    2. Type reset system shutdown
    . Press 
    En te r onc e.
    NOTE:
    Do not p ress En t e r again. This will forc e the AUDIX to shutd own 
    immed iately, d rop p ing  all ac tive c alls on the AUDIX.
    3. The “ SHUTDOWN Comp leted ”  messag e ap p ears when the AUDIX is 
    suc c essfully shutd own. This takes ab out 2 minutes.
    4. The AUDIX System can now b e removed  for service.
    Power Up the AUDIX System
    nIf the AUDIX was removed  from the c ab inet:
    1. Re-install the AUDIX and  allow it to b oot up  automatic ally.
    2. Check for AUDIX System errors.
    nIf the AUDIX remained in the c ab inet b ut p ower was removed  from the 
    c ab inet:
    1. Power up  the c ab inet. The AUDIX reb oots automatic ally.
    2. Check for AUDIX System errors.
    nIf the AUDIX remained in the c ab inet and  the c ab inet was not powered 
    down:
    1. At the AUDIX c onsole, hold  the 
    crtl key and  typ e cc
    .
    2. Type 5
     at the p romp t. In ab out 2 minutes, the AUDIX b oots up .
    3. When the system initialization is c omp lete, log  in as craft
    .
    4. Check for AUDIX System errors. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    G3vs with Intel 386 or Risc Processor to R8r 
    4-20 DEFINITY AUDIX Power Procedures 
    4 
    						
    							Multicarrier G2 Universal Module to R8r EPN 
    5-1 Single-Mode Fiber Attenuators 
    5
    DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    5
    Multicarrier G2 Universal Module
    to R8r EPN
    This chapter provides the information necessary to upgrade a DEFINITY G2 
    universal mod ule to a multic arrier EPN of a R8r system. 
    DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e 
    lists Release 8 features and  func tions, and  provid es the c ommand s, p roc ed ures, 
    and  forms to initialize and  ad minister the system.
    Single-Mode Fiber Attenuators
    Attenuators may b e req uired when using sing le-mod e fib er. See the tab le b elow.
    A d ifferent value attenuator may b e req uired  even thoug h the fib er sp an is 
    b etween the same 2 c ab inets (loc al and remote c ab inet). Refer to 
    DEFINITY 
    Enterp rise Communic ations Server Release 8 Installation and  Test for Multic arrier 
    Cab inets
     for detailed  fib er attenuator information. 106060718 5 d B attenuator 2 for eac h fib er c onnec tion
    106060734 10 dB attenuator 2 for eac h fib er c onnec tion
    106061021 15 dB attenuator  2 for eac h fib er c onnec tion 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-2 Read This First 
    5
    Read This First
    Service Interruption
    The up g rad e p roc ess req uires a servic e interruption of ab out 40 minutes. 
    Coord inate this servic e interrup tion with the c ustomer and  the loc al ac c ount 
    team.
    Call Management System (CMS)
    The CMS link is dropped and restarted during the upgrade. This causes CMS 
    d ata to b e lost. This d ata loss c an be minimized  if the up g rad e is p erformed  just 
    after the last CMS measurement interval.
    All measurement d ata is lost d uring  the up g rad e (inc lud ing  BCMS). If need ed , 
    the reports may be printed before the upgrade begins.
    CMS c ould  ab ort the p roc essing of a c all if a measured  trunk that was part of the 
    c onferenc e d rop p ed  off the c all b efore the end  of the c all. Customers 
    exp erienc ing  this symp tom and  who are running  R3V4 CMS should  upd ate to 
    r3v4ao.e or hig her.
    Preventing Translation Errors
    When instruc ted  in this c hap ter, p erform the save translation
     c ommand . 
    Afterward , c hec k for translation errors b efore p roc eed ing  with the up g rad e.
    NOTE:
    Be sure that the translations g et saved  without errors b efore c ontinuing  with 
    any up g rad e.
    If errors are d etec ted , refer to ‘‘No Translations After Upgrade’’
     in Appendix B, 
    ‘‘Troubleshooting  an Upgrade’’ to c orrec t the p rob lem. Do not c ontinue with the 
    up g rad e until the errors are c orrec ted . 
    Contact Network Technicians
    Contac t the tec hnic ian for eac h p ub lic  and  p rivate network ac c essed  b y the 
    system b efore the upg rad e b eg ins. Otherwise, if these tec hnic ians are not aware 
    of the servic e interrup tion c aused  b y the up g rad e, it is possible that 
    network-ac c ess trunk fac ilities will b e b usied  out at the far end .
    Communication Between Equipment Rooms
    For an up g rad e where some of the eq uip ment resid es at a remote loc ation, the 
    up g rad e ac tivity is muc h easier if temp orary c ommunic ation is established  
    b etween the equip ment rooms. 
    						