    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-63 High Reliability 
    5
    2. Behind control carrier A of EPN c abinet 3:
    nInstall a lig htwave transc eiver on the c ab le c onnec tor at slot 3A01.
    NOTE:
    Attenuators may be required for single mode fiber using a 
    300A Lightwave Transc eiver
    nConnec t the remaining  end  of the fib er c ab le to the transc eiver just 
    installed .
    nRoute the c ab le to the c ab le tray and  d own, out of the c ab inet, 
    throug h the c ab le manag er to the PDS c ross-c onnec t fac ility.
    nConnec t the fib er c ab le to the lig htguid e interc onnec t unit p rovid ed .
    nCarefully attac h the fib er op tic  c ab le (with c ab le ties) to the wall of 
    the c ab le tray at the b uilt-in c ab le tie p ositions.
    nCoil up  the surp lus fib er c ab le and  p lac e it in the c ab le manag er.
    3. Behind control carrier A of EPN c abinet 2:
    nInstall a lig htwave transc eiver on the c ab le c onnec tor at slot 2A02.
    nConnec t a fib er op tic  c ab le to the transc eiver just installed .
    nRoute the c ab le to the c ab le tray and  d own, out of the c ab inet, 
    throug h the c ab le manag er to the PDS c ross-c onnec t fac ility.
    nConnec t the fib er c ab le to the lig htguid e interc onnec t unit p rovid ed .
    nCarefully attac h the fib er op tic  c ab le (with c ab le ties) to the wall of 
    the c ab le tray at the b uilt-in c ab le tie p ositions.
    4. Behind control carrier A of EPN c abinet 3:
    nInstall a lig htwave transc eiver on the c ab le c onnec tor at slot 3A02.
    NOTE:
    Attenuators may be required for single mode fiber using a 
    300A Lightwave Transc eiver
    nConnec t the remaining end  of the c ab le to the transc eiver just 
    installed .
    nRoute the c ab le to the c ab le tray and  d own, out of the c ab inet, 
    throug h the c ab le manag er to the PDS c ross-c onnec t fac ility.
    nConnec t the fib er c ab le to the lig htguid e interc onnec t unit p rovid ed .
    nCarefully attac h the fib er op tic  c ab le (with c ab le ties) to the wall of 
    the c ab le tray at the b uilt-in c ab le tie p ositions.
    nCoil up  the surp lus fib er c ab le and  p lac e it in the c ab le manag er. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-64 High Reliability 
    5
    Figure 5-18. High Reliability Release 8 with Two or Three Port NetworksFigure Notes
    1. Cabinet 1 Proc essor Port Network
    2. Cabinet 2 Exp ansion Port Network 13. Cab inet 3 Exp ansion Port 
    Network 2 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-65 High Reliability 
    5
    Figure 5-19. Fiber Optic Connections PPN to EPN1
    Figure 5-20. Fiber Optic Connections PPN to EPN2 Figure Notes
    1. Lightwave Transc eiver
    2. To PPN Carrier C Slot 1C02
    3. To EPN 1 Carrier A Slot 2A01
    4. Fiber Optic Cable5. Op tic al Cross-Connec t Fac ility
    6. 100A Lig htg uid e Interc onnec t Unit (LIU)
    7. TX COnnec tor
    8. RX Connec tor
    Figure Notes
    1. Lightwave Transc eiver
    2. To PPN Carrier D Slot 1D02
    3 . To  EPN 2  C a r r ie r A Sl o t  3 A0 1
    4. Fiber Optic Cable5. Op tic al Cross-Connec t Fac ility
    6. 100A Lig htg uid e Interc onnec t Unit
    7. TX Connec tor
    8. RX Connec tor
    cydf013 CJL102396
    RX TX
    2
    22 1
    11
    22
    11
    cydf013 CJL102396
    RX TX
    2
    22 1
    11
    22
    11 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-66 High Reliability 
    5
    Figure 5-21. Fiber Optic Connections EPN1 to EPN2
    Verify Usable Circuit Pack Vintages
    Verify that eac h reused  c irc uit p ac k c onforms to the usable vintag e req uirements 
    for a Release 8 system (see Referenc e Guid e for Circ uit Pac k Vintag es and  
    Chang e Notic es).
    Remove Power-Failure Ground Wire
    Remove the 10 AWG (#25) (2.6 mm2) g round  wire from the p ower-failure transfer 
    unit.Figure Notes
    1. Lightwave Transc eiver
    2 . To  EPN 1  C a r r ie r A Sl o t  2 A0 2
    3. To EPN2 Cab inet A Slot 3A02
    4. Fiber Optic Cable5. Op tic al Cross-Connec t Fac ility
    6. 100A Lig htg uid e Interc onnec t Unit
    7. TX Connec tor
    8. RX Connec tor
    cydf013 CJL102396
    RX TX
    2
    22 1
    11
    22
    11 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-67 High Reliability 
    5
    Boot the Release 8 System
    1. Connect the management terminal to the “ TERMINAL”  c onnec tor b ehind  
    PPN c ontrol c arrier “ A,”  or install the G3-MA ac c ord ing  to the “ Set Up  
    G3-MA” chap ter of 
    DEFINITY Communic ations System Generic  3 
    Management Applications 
    — Operations, 585-229-202.
    2. Insert the translation c ard s in the TN794 fac ep lates.
    3. At eac h EPN p ower d istrib ution unit, set the main c irc uit breaker to ON.
    4. At the PPN p ower d istribution unit, set the main c irc uit b reaker to ON.
    5. The system performs the reset level 4 rebooting proc ess, loading the 
    d efault system translations from the translation c ard . This takes 8 to 11 
    minutes.
    6. Get the ord er numb er of the up g rad e, and  c all the reg ional CSA to req uest 
    an “ init”  log in so the rig ht-to-use options c an b e enab led  on the up g rad ed  
    system.
    7. To use Ac cess Security Gateway (ASG), see Appendix C, ‘‘Access 
    Security Gateway’’.
    Set Daylight Savings Rules
    You c an set up  to 15 c ustomized  d aylig ht saving s time rules. If you have c ab inets 
    in several different time zones, you c an set up  rules for eac h on a loc ation b asis. 
    A d aylig ht saving s time rule sp ec ifies the exac t time when you want to transition 
    to and  from d aylig ht saving s time. It also sp ec ifies the inc rement at whic h to 
    transition. 
    NOTE:
    The d efault d aylig ht saving s rule is 0
    , no d aylig ht saving s.
    1. Type change daylight-savings-rules
     and press 
    En t e r. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-68 High Reliability 
    5
    2. Type the appropriate start and stop information in the Change Day
    , 
    Month
    , Date
    , Time
    , and  Increment
     field s for eac h rule. (for examp le, 
    1:00
     eq uals one hour) 
    NOTE:
    You c an c hang e any rule exc ep t rule 0 (zero). You c annot delete a 
    d aylig ht saving s rule if it is in use on either the Loc ations or Date and 
    Ti m e  s c re e n s .
    3. When d one, p ress 
    En te r.
     
    DAYLIGHT SAVINGS RULES
    Rule Change Day Month___Date Time____Increment
    0: No Daylight Savings
    1: Start: first Sunday
    ___ on or after April ___  1 at _2:0001:00Stop:  first Sunday___ on or after October _ 25 at _2:002: Start: first _________ on or after _________ __ at __:__
    Stop:  first _________ on or after _________ __ at __:__
    3: Start: first _________ on or after _________ __ at __:__
    Stop:  first _________ on or after _________ __ at __:__
    4: Start: first _________ on or after _________ __ at __:__
    Stop:  first _________ on or after _________ __ at __:__
    5: Start: first _________ on or after _________ __ at __:__
    Stop:  first _________ on or after _________ __ at __:__
    6: Start: first _________ on or after _________ __ at __:__
    Stop:  first _________ on or after _________ __ at __:__
    7: Start: first _________ on or after _________ __ at __:__
    Stop:  first _________ on or after _________ __ at __:__ 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-69 High Reliability 
    5
    Set Date and Time
    1. Type set time 
    and 
    press En t e r to b ring  up  the Date and  Time sc reen.
    .
    Screen 5-2. Typical Date and Time Screen
    2. Typ e the d ay of the week in Eng lish (Sunday throug h Saturd ay). See 
    Table 5-12
     for Eng lish day of the week names.
    Table 5-12. English Day of the Week Names
    Day Number Day Name
    1Sunday
    2 Mond ay
    3Tuesday
    4 Wed nesd ay
    5Thursday
    6Friday
    7Saturday
     
                               DATE AND TIME
    DATE
     Day of the Week: Tuesday
    Month: FebruaryDay of the Month: 8 Year: 2000
    TIME
    Hour: 20 Minute: 30Second: XX Type: standardDaylight Savings Rule: 0 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-70 High Reliability 
    5
    3. The c ursor is p ositioned  on the Month:
     field . Typ e the c urrent month in 
    Eng lish (January throug h Dec emb er). See Table 5-13
     for Eng lish month 
    names. After the month is entered, p ress 
    Ta b to move to next field .
    4. The c ursor is p ositioned  on the Day of the Month:
     field . Typ e the d ay 
    of month (1 through 31) and  p ress 
    Ta b to move to the next field.
    5. The c ursor is p ositioned  on the Year:
     field . Typ e the c urrent year and  
    p ress 
    TA B to move to the next field .
    6. The c ursor is p ositioned  on the Hour:
     field . Typ e the c urrent hour for a 
    24-hour c loc k. Press
     Ta b to move to the next field .
    7. The c ursor is p ositioned  on the Minute:
     field . Type c urrent minute (0 
    throug h 59). Sec ond s c annot b e set.
    8. Type standard
     or daylight savings
     in the Type
     field .
    9. Typ e the rule (numb er) in the Daylight Savings Rule
     field.
    10. Press 
    En t e r when the information is c orrec t.
    11. Typ e display time 
    and press 
    En te r  to verify d ate/time d ata.
    Table 5-13. English Month Names
    Month Number Month Name
    1 January
    2February
    3March
    4April
    5May
    6June
    7July
    8August
    9 Sep temb er
    10 Oc tob er
    11 November
    12 Dec emb er 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-71 High Reliability 
    5
    Set Additional Administration
    1. Type list configuration software-version long
     and  p ress En te r  to 
    c omp are the version numb er of the DEFINITY ECS Release 8 software 
    p rog ram with the version numb er (written on a lab el on the p roc essor’s 
    fac ep late). If the version numb ers are not the same, c hang e the version 
    numb er on the proc essor lab el so that they ag ree.
    2. Type change system-parameters customer-options
     and press 
    En te r. 
    Use this sc reen to enable the Release 8 op tion and  to assig n the 
    c ustomer’s other rig ht-to-use op tions on the G2-to-DEFINITY ECS Release 
    8 upg rad e ord er. See 
    DEFINITY Enterp rise Communic ations Server 
    Release 8 Ad ministrator’s Guid e
    , for d etails on enab ling  these op tions.
    3. Type change site-data
     and press 
    En te r. Use this sc reen to assig n 
    system-sp ec ific  information (suc h as b uild ing , floor, stations, and so 
    forth).
    4. Type status system 1
     and press 
    En t e r  to verify the system is in the 
    “active/standby” mode.
    5. Type save translation
     and press 
    En te r. This instruc ts the system to write all 
    translation information from memory to the translation c ard .
    !WARNING:
    If the terminal sc reen d isp lays “ translation c orrup tion d etec ted ; c all 
    Luc ent Tec hnolog ies distrib utor immed iately” , an error was d etec ted  
    in the translations.
    Reconnect Cables
    1. At the power d istribution unit of the up g rad ed  EPN, set the main c irc uit 
    b re a k e r  t o  O FF.
    NOTE:
    Powering  d own an EPN without p owering  d own the PPN will set off 
    alarms. However, these alarms should  c lear after p ower is restored  
    to eac h EPN.
    2. Temporarily d isc onnec t the lig htwave transc eivers and  fib er op tic  c ab les, 
    alread y lab eled , from the app rop riate c arriers.
    3. Rep lac e the b ac k d oors or bac k p anels.
    4. At the EPN c ab inet, rec onnec t the lig htwave transc eivers, fib er op tic  
    c ab les, and  the c onnec tor c ab les assoc iated  with the c arrier b eing  
    rep lac ed .
    5. Install the front d oor on the EPN c abinet. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Multicarrier G2 Universal Module to R8r EPN 
    5-72 High Reliability 
    5
    Power Up the EPN Cabinets
    1. At eac h EPN p ower d istrib ution unit, set the main c irc uit breaker to ON.
    After ab out 40 sec ond s, EPN power and  PPN/EPN c ommunic ations return.
    2. After p ower returns to eac h EPN and  all troub le is c leared , verify that the 
    EMERGENCY TRANSFER CONTROL switc h is set to AUTO. This restores 
    the system to the normal mod e.
    Retranslate Port Circuits
    If p ort c irc uit p ac ks in the G2 mod ule c ontrol c arrier were reloc ated  in order to 
    put:
    nA c ritic al p ort c irc uit p ac k, requiring  long er nominal battery hold over (suc h 
    as a DS1 or an Announc ement c irc uit p ac k), in a p ort slot
    nA TN736, TN752, or TN755 power sup p ly in p ort slots “ 18”  and  “ 19”
    nA TN776 or TN570 Exp ansion Interfac e in p ort slot “ 1”
    nA TN776 or TN570 in p ort slot “ 2”  (for a sec ond  d irec tly c onnec ted  EPN)
    of the new exp ansion c ontrol c arrier, verify that they were retranslated  d uring  the 
    off-site software up g rad e. If not, they must b e retranslated now. Refer to 
    DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e, 
    for instruc tions on p erforming  the retranslations.
    Enable TTI
    1. Type change system-parameters features
     and press En t e r. 
    2. On the sec ond  sc reen, set the Enabled?
     field  to y
     to ac tivate the TTI 
    feature.
    Check Link Status
    1. Type display communication-interface links
     and press En te r. Compare it 
    with the earlier status.
    2. Type status link
     
    number and  p ress En t e r. Rep eat this step  for eac h link.
    Enable Scheduled Maintenance
    Ty p e  change system-parameters maintenance
     and press En t e r. Enab le the 
    sc hed uled  d aily maintenanc e. 
    						