    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-59 Add IP Interface Assembly 
    6
    Connect the Modem
    NOTE:
    These instruc tions are for c onnec ting  the U.S. Rob otic s modem sup p lied  to 
    U.S. c ustomers only. If using  a d ifferent mod em, follow the manufac turer’s 
    instruc tions on c onnec ting  the mod em.
    1. Connec t the RS232 p ort of the mod em to the MODEM c onnec tor of the 
    TN802B external c ab le assembly. 
    NOTE:
    Chec k the lab els near the c onnec tors; the MODEM and  COM2 
    c onnec tors look the same.
    2. Connec t an analog  telephone line to the leftmost analog -line p ort on the 
    mod em as shown in Figure 6-25
    . 
    3. Make sure that the mod em’s DIP switc hes are set as shown in 
    Figure 6-25
     and  Table 6-7. 
    4. Plug  the mod em into an AC p ower outlet.
    5. Turn on the mod em using  the switc h on the front of the mod em.
    Figure 6-25. External Modem Connections for U.S. Robotics Sporster Figure Notes
    1. Connec t analog  line here.
    2. DIP switc h 5 must b e up .3. Connec t MODEM c onnec tor here.
    4. Connec t p ower c onnec tor here.
    12345678
    modfrobo KLC 030499
    234
    1 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-60 Add IP Interface Assembly 
    6
    Connect the Monitor, Keyboard, and Mouse
    NOTE:
    Only make these c onnec tions if ad ministered  loc ally. Not nec essary if 
    ad ministered  remotely.
    You must c onnec t these b efore inserting  the TN802B IP Interfac e.
    1. Attac h a VGA monitor to the VGA c onnec tor of the TN802B IP Interfac e 
    external c ab le assemb ly.
    2. Attac h the keyb oard  to the KEYBOARD c onnec tor of the external c ab le 
    assemb ly.
    3. Attach the mouse to the MOUSE connector of the external c able 
    assemb ly.
    4. Plug  the monitor into an AC p ower rec ep tac le and  turn it on.
    Table 6-7. U.S. Robotics Modem Dip Switch Settings
    Dip 
    Switch Setting Description
    1UP
    DOWNData Terminal Read y normal
    Data Terminal Read y overrid e
    2UP
    DOWNVe r b a l  r e s u lt  c o d e s
    Numeric  result c od es
    3UP
    DOWNSuppress result codes
    Disp lay result cod es
    4UP
    DOWNEc ho offline c ommand s
    No ec ho, offline c ommand s
    5UP
    DOWNAuto answer on first ring or higher if specified in NVRAM
    Auto answer off
    6UP
    DOWNCarrier d etec t normal
    Carrier d etec t overrid e
    7UP
    DOWNLoad  NVRAM d efaults
    Load  fac tory d efaults
    8UP
    DOWNDumb  mod e
    Sm a rt  m o d e 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-61 Add IP Interface Assembly 
    6
    Connect the Ethernet
    1. Connec t the network c ab le to the ETHERNET c onnec tor on the TN802B 
    external c ab le assemb ly.
    NOTE:
    You need  a CAT5 or better c ab le for 100-Mb yte operation.
    Install the Circuit Pack
    !CAUTION:
    When add ing  or rep lac ing  any hard ware, b e sure to g round  yourself against 
    elec trostatic  d isc harg e (ESD) b y wearing  a g round ed  wrist strap .
    NOTE:
    The TN802B IP Interfac e is hot-swap p ab le, so you d o not need  to p ower 
    d own the c arrier to install it.
    If you need  to remove the TN802B IP Interfac e from the c arrier at a later 
    time, shut down Wind ows NT first b y p ressing the rec essed reset button on 
    the fac ep late (see Figure 6-26
    ) of the TN802B IP Interfac e until the LCD 
    shows a flashing MSHUT *
    . When the flashing  stop s and  the asterisk 
    d isap p ears (ab out 2 min), it is safe to remove the c irc uit p ac k. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-62 Add IP Interface Assembly 
    6
    Figure 6-26. TN802B IP Interface faceplate
    NOTE:
    To p rop erly seat the c irc uit p ac k, p ush firmly on the front of the fac ep late 
    until the latc h reac hes the b ottom rail of the c arrier. Then c lose the latc h 
    until it is fully eng ag ed .
    1. Insert the TN802B IP Interfac e into the rig htmost of the three slots you 
    reserved  for it (see Figure 6-27
    ).
    When you p lug  in the TN802B IP Interfac e, the c irc uit p ac k starts to b oot 
    and  the LCD read s PC Boot 
    then after ab out 3 to 4 minutes it c hang es to 
    IP TRK *
    , the default mod e. Figure Notes
    1. LCD d isp lay
    2. Reset b utton (rec essed )
    3. Red  b oard  status LED4. PCMCIA c ard slot
    5. Yellow PCMCIA d isk-in-use LED
    1
    2
    3
    4
    5
    fpdfmapd KLC 030899 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-63 Add IP Interface Assembly 
    6
    Figure 6-27. J58890MA-1 L30 IP Interface Assembly
    Test the Modem
    1. Check for dial tone.
    2. Contac t Luc ent Tec hnolog ies Customer Sup p ort and  ask a rep resentative 
    to d ial into your IP Interfac e server. 
    Administer the IP Interface
    Ad minstration is d one either loc ally or remotely. If ad ministered  loc ally, p roc eed  
    with the following  ad minstration step s on the attac hed  keyb oard , mouse, and  
    monitor. If administered  remotely, c all your servic e rep resentative to start the 
    p roc ess.
    456
    789
    1
    0
    1
    11
    21
    3
    1
    41
    51
    6
    ndfmapd KLC 031299
    456
    789
    1
    0
    1
    11
    21
    3
    1
    41
    51
    6
    indfmapd KLC 031299 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-64 Add IP Interface Assembly 
    6
    Administration Steps
    1. Log in as craft
    .
    2. Type change circuit-pack
     and  p ress 
    En te r.
    3. Chec k the Cod e c olumn to see if the slots ab ove the TN802B say 
    DSMAPD or MEDPRO.
    .
    4. If MEDPRO, g o to the entry just ab ove the TN802B that says MEDPRO.
    5. Type DSMAPD, and press 
    En te r. Chang ing the one entry automatic ally 
    c hang es the entry ab ove it. If it is in IP Trunk mode, you g et the following 
    error message:
    MedPro type requires TN802 with application. Type 
    MEDPRO on circuit-packs form.
    Log onto the TN802B Interface Server 
    If administered  remotely throug h p c ANYWHERE:
    1. Dial in to the server through pcANYWHERE using the dialup number 
    supplied. 
    2. Clic k on the p c ANYWHERE Remote Host Computer b utton on the toolb ar 
    to send  
    CTRL ALT DEL to the host.
    3. Type administrator
     in the User Name
     field .
    4. Type iptrunk
     in the Password
     field  and  c lic k OK
    . 
    5. After log g ing  on for the first time, c hang e the ad ministrator p assword and , 
    if d esired , the user name, to ensure sec urity. See your Wind ows NT server 
    d oc umentation for d etails.
    change circuit-packs                                            Page   1 of   5 
                                  CIRCUIT PACKS                                     
            Cabinet: 1                            Carrier: A
                                             Carrier Type: processor        
     Slot Code  Sf Mode   Name               Slot Code  Sf Mode   Name
    11: DSMAPD RESERVED-IP
    01: TN754  DIGITAL LINE  12: DSMAPD  RESERVED-IP
    02: TN758  POOLED MODEM  13: TN802  B  MAPD BOARD
    03: TN2144  ANALOG LINE  14: 
    04: TN746  B  ANALOG LINE  15: 
    05 16:         
    06: TN771  C  MAINTENANCE/TEST  
    07: TN464  F  DS1 INTERFACE     
    08: TN2140  E&M TIE TRUNK     
    09: TN767  E  DS1 INTERFACE     
    10: TN799  B  CONTROL-LAN       
      # indicates circuit pack conflict. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-65 Add IP Interface Assembly 
    6
    If administered  loc ally on a monitor, keyb oard, and  mouse:
    1. Press 
    CTRL, ALT, and  DEL simultaneously.
    2. Type administrator
     in the User Name
     field .
    3. Type iptrunk
     in the Password
     field  and  c lic k OK
    . 
    4. After log g ing  on for the first time, c hang e the ad ministrator p assword and , 
    if d esired , the user name, to ensure sec urity. See your Wind ows NT server 
    d oc umentation for d etails.
    A-Law versus Mu-Law
    For systems using  A-Law c omp and ing , an ad d itional p roc ed ure is nec essary. 
    On the SAT:
    1. Busyout the trunk g roup  assoc iated  with the IP trunk b y typing  busyout 
    board 
    UUCSS and  p ressing  En t e r.
    In the Wind ows interfac e to TN802B:
    1. Click on Control Panel > Services.
    2. Highlight IP Trunk Service
    , then c lic k on Stop
    .
    3. In the lower left-hand  c orner, rig ht-c lic k Start >  Exp lore.
    4. Go to the c : d rive and  c lic k on its, then b in.
    5. Double-c lic k on the its.ini file to op en it in Notep ad .
    6. Und er the [ Med iaLib ]  sec tion, g o to COMPANDING= MLAW. Chang e 
    MLAW
     to ALAW
    .
    7. Click on File > Save
     to save the file.
    8. Click on File > Exit
     to exit Notep ad .
    9. Click on Control Panel > Services.
    10. Highlight IP Trunk Service
    , then c lic k on Start
    .
    NOTE:
    Do not selec t Startup .
    After servic e has started , g o to the SAT:
    1. Release the trunk g roup  assoc iated  with the IP trunk b y typing  release 
    board
     
    UUCSS and  p ressing  En t e r. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-66 Add IP Interface Assembly 
    6
    Assign Server and Domain Names
    The Windows NT server identifies servers using a server name plus a domain 
    name that loc ates the named  server in a p artic ular p art of the network. The 
    TN802B IP Interfac e is ship p ed  with generic  server and  d omain names. Assig n 
    rep lac ement names that are meaning ful within your network. 
    1. Click on My Computer > Control Panel > Network
    .
    2. Selec t the Identification
     tab , then c lic k Change
    .
    3. Typ e the new server name in the Computer Name 
    field .
    4. Typ e the new d omain name in the Domain
     field and  c lic k OK > OK > 
    Close
    .
    5. When p romp ted  to reb oot the c omp uter, selec t one of the following  
    op tions:
    nNo
     if you have not assig ned  IP ad dresses then g o to ‘‘Assign an IP 
    Address’’
    nYe s
     if you have assigned  IP ad dresses. 
    Assign an IP Address
    1. Click on My Computer > Control Panel > Network
    .
    2. Click the Protocols
     tab .
    3. Select TCP/IP Protocol 
    from the list.
    4. Click the Properties
     op tion in the Network wind ow.  
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-67 Add IP Interface Assembly 
    6
    5. Verify that the Adapter
     drop  d own menu lists 2 DEC Ethernet ad ap ters.
    !CAUTION:
    Do not c hange any setting s on the ad ap ter lab eled  [ 1]  for any 
    reason.
    6. Selec t the DEC Ethernet ad ap ter lab eled  [ 2] . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-68 Add IP Interface Assembly 
    6
    7. Typ e a valid  IP ad d ress for the IP Interfac e server in the IP Address:
     
    field .
    8. Typ e the ap p rop riate sub net mask in the Subnet Mask:
     field. 
    NOTE:
    Not all networks req uire step s 9 throug h 18. Chec k with the loc al 
    network ad ministrator to determine whic h are req uired .
    9. If you use g ateways, type the IP ad d ress of the d efault g ateway for the IP 
    Interfac e server in the Default Gateway:
     field.
    10. Clic k on the DNS tab  and  verify that the d omain DNS server is c orrec t. 
    						