Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-59 Add IP Interface Assembly 6 Connect the Modem NOTE: These instruc tions are for c onnec ting the U.S. Rob otic s modem sup p lied to U.S. c ustomers only. If using a d ifferent mod em, follow the manufac turer’s instruc tions on c onnec ting the mod em. 1. Connec t the RS232 p ort of the mod em to the MODEM c onnec tor of the TN802B external c ab le assembly. NOTE: Chec k the lab els near the c onnec tors; the MODEM and COM2 c onnec tors look the same. 2. Connec t an analog telephone line to the leftmost analog -line p ort on the mod em as shown in Figure 6-25 . 3. Make sure that the mod em’s DIP switc hes are set as shown in Figure 6-25 and Table 6-7. 4. Plug the mod em into an AC p ower outlet. 5. Turn on the mod em using the switc h on the front of the mod em. Figure 6-25. External Modem Connections for U.S. Robotics Sporster Figure Notes 1. Connec t analog line here. 2. DIP switc h 5 must b e up .3. Connec t MODEM c onnec tor here. 4. Connec t p ower c onnec tor here. 12345678 modfrobo KLC 030499 234 1
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-60 Add IP Interface Assembly 6 Connect the Monitor, Keyboard, and Mouse NOTE: Only make these c onnec tions if ad ministered loc ally. Not nec essary if ad ministered remotely. You must c onnec t these b efore inserting the TN802B IP Interfac e. 1. Attac h a VGA monitor to the VGA c onnec tor of the TN802B IP Interfac e external c ab le assemb ly. 2. Attac h the keyb oard to the KEYBOARD c onnec tor of the external c ab le assemb ly. 3. Attach the mouse to the MOUSE connector of the external c able assemb ly. 4. Plug the monitor into an AC p ower rec ep tac le and turn it on. Table 6-7. U.S. Robotics Modem Dip Switch Settings Dip Switch Setting Description 1UP DOWNData Terminal Read y normal Data Terminal Read y overrid e 2UP DOWNVe r b a l r e s u lt c o d e s Numeric result c od es 3UP DOWNSuppress result codes Disp lay result cod es 4UP DOWNEc ho offline c ommand s No ec ho, offline c ommand s 5UP DOWNAuto answer on first ring or higher if specified in NVRAM Auto answer off 6UP DOWNCarrier d etec t normal Carrier d etec t overrid e 7UP DOWNLoad NVRAM d efaults Load fac tory d efaults 8UP DOWNDumb mod e Sm a rt m o d e
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-61 Add IP Interface Assembly 6 Connect the Ethernet 1. Connec t the network c ab le to the ETHERNET c onnec tor on the TN802B external c ab le assemb ly. NOTE: You need a CAT5 or better c ab le for 100-Mb yte operation. Install the Circuit Pack !CAUTION: When add ing or rep lac ing any hard ware, b e sure to g round yourself against elec trostatic d isc harg e (ESD) b y wearing a g round ed wrist strap . NOTE: The TN802B IP Interfac e is hot-swap p ab le, so you d o not need to p ower d own the c arrier to install it. If you need to remove the TN802B IP Interfac e from the c arrier at a later time, shut down Wind ows NT first b y p ressing the rec essed reset button on the fac ep late (see Figure 6-26 ) of the TN802B IP Interfac e until the LCD shows a flashing MSHUT * . When the flashing stop s and the asterisk d isap p ears (ab out 2 min), it is safe to remove the c irc uit p ac k.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-62 Add IP Interface Assembly 6 Figure 6-26. TN802B IP Interface faceplate NOTE: To p rop erly seat the c irc uit p ac k, p ush firmly on the front of the fac ep late until the latc h reac hes the b ottom rail of the c arrier. Then c lose the latc h until it is fully eng ag ed . 1. Insert the TN802B IP Interfac e into the rig htmost of the three slots you reserved for it (see Figure 6-27 ). When you p lug in the TN802B IP Interfac e, the c irc uit p ac k starts to b oot and the LCD read s PC Boot then after ab out 3 to 4 minutes it c hang es to IP TRK * , the default mod e. Figure Notes 1. LCD d isp lay 2. Reset b utton (rec essed ) 3. Red b oard status LED4. PCMCIA c ard slot 5. Yellow PCMCIA d isk-in-use LED 1 2 3 4 5 fpdfmapd KLC 030899
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-63 Add IP Interface Assembly 6 Figure 6-27. J58890MA-1 L30 IP Interface Assembly Test the Modem 1. Check for dial tone. 2. Contac t Luc ent Tec hnolog ies Customer Sup p ort and ask a rep resentative to d ial into your IP Interfac e server. Administer the IP Interface Ad minstration is d one either loc ally or remotely. If ad ministered loc ally, p roc eed with the following ad minstration step s on the attac hed keyb oard , mouse, and monitor. If administered remotely, c all your servic e rep resentative to start the p roc ess. 456 789 1 0 1 11 21 3 1 41 51 6 ndfmapd KLC 031299 456 789 1 0 1 11 21 3 1 41 51 6 indfmapd KLC 031299
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-64 Add IP Interface Assembly 6 Administration Steps 1. Log in as craft . 2. Type change circuit-pack and p ress En te r. 3. Chec k the Cod e c olumn to see if the slots ab ove the TN802B say DSMAPD or MEDPRO. . 4. If MEDPRO, g o to the entry just ab ove the TN802B that says MEDPRO. 5. Type DSMAPD, and press En te r. Chang ing the one entry automatic ally c hang es the entry ab ove it. If it is in IP Trunk mode, you g et the following error message: MedPro type requires TN802 with application. Type MEDPRO on circuit-packs form. Log onto the TN802B Interface Server If administered remotely throug h p c ANYWHERE: 1. Dial in to the server through pcANYWHERE using the dialup number supplied. 2. Clic k on the p c ANYWHERE Remote Host Computer b utton on the toolb ar to send CTRL ALT DEL to the host. 3. Type administrator in the User Name field . 4. Type iptrunk in the Password field and c lic k OK . 5. After log g ing on for the first time, c hang e the ad ministrator p assword and , if d esired , the user name, to ensure sec urity. See your Wind ows NT server d oc umentation for d etails. change circuit-packs Page 1 of 5 CIRCUIT PACKS Cabinet: 1 Carrier: A Carrier Type: processor Slot Code Sf Mode Name Slot Code Sf Mode Name 11: DSMAPD RESERVED-IP 01: TN754 DIGITAL LINE 12: DSMAPD RESERVED-IP 02: TN758 POOLED MODEM 13: TN802 B MAPD BOARD 03: TN2144 ANALOG LINE 14: 04: TN746 B ANALOG LINE 15: 05 16: 06: TN771 C MAINTENANCE/TEST 07: TN464 F DS1 INTERFACE 08: TN2140 E&M TIE TRUNK 09: TN767 E DS1 INTERFACE 10: TN799 B CONTROL-LAN # indicates circuit pack conflict.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-65 Add IP Interface Assembly 6 If administered loc ally on a monitor, keyb oard, and mouse: 1. Press CTRL, ALT, and DEL simultaneously. 2. Type administrator in the User Name field . 3. Type iptrunk in the Password field and c lic k OK . 4. After log g ing on for the first time, c hang e the ad ministrator p assword and , if d esired , the user name, to ensure sec urity. See your Wind ows NT server d oc umentation for d etails. A-Law versus Mu-Law For systems using A-Law c omp and ing , an ad d itional p roc ed ure is nec essary. On the SAT: 1. Busyout the trunk g roup assoc iated with the IP trunk b y typing busyout board UUCSS and p ressing En t e r. In the Wind ows interfac e to TN802B: 1. Click on Control Panel > Services. 2. Highlight IP Trunk Service , then c lic k on Stop . 3. In the lower left-hand c orner, rig ht-c lic k Start > Exp lore. 4. Go to the c : d rive and c lic k on its, then b in. 5. Double-c lic k on the its.ini file to op en it in Notep ad . 6. Und er the [ Med iaLib ] sec tion, g o to COMPANDING= MLAW. Chang e MLAW to ALAW . 7. Click on File > Save to save the file. 8. Click on File > Exit to exit Notep ad . 9. Click on Control Panel > Services. 10. Highlight IP Trunk Service , then c lic k on Start . NOTE: Do not selec t Startup . After servic e has started , g o to the SAT: 1. Release the trunk g roup assoc iated with the IP trunk b y typing release board UUCSS and p ressing En t e r.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-66 Add IP Interface Assembly 6 Assign Server and Domain Names The Windows NT server identifies servers using a server name plus a domain name that loc ates the named server in a p artic ular p art of the network. The TN802B IP Interfac e is ship p ed with generic server and d omain names. Assig n rep lac ement names that are meaning ful within your network. 1. Click on My Computer > Control Panel > Network . 2. Selec t the Identification tab , then c lic k Change . 3. Typ e the new server name in the Computer Name field . 4. Typ e the new d omain name in the Domain field and c lic k OK > OK > Close . 5. When p romp ted to reb oot the c omp uter, selec t one of the following op tions: nNo if you have not assig ned IP ad dresses then g o to ‘‘Assign an IP Address’’ nYe s if you have assigned IP ad dresses. Assign an IP Address 1. Click on My Computer > Control Panel > Network . 2. Click the Protocols tab . 3. Select TCP/IP Protocol from the list. 4. Click the Properties op tion in the Network wind ow.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-67 Add IP Interface Assembly 6 5. Verify that the Adapter drop d own menu lists 2 DEC Ethernet ad ap ters. !CAUTION: Do not c hange any setting s on the ad ap ter lab eled [ 1] for any reason. 6. Selec t the DEC Ethernet ad ap ter lab eled [ 2] .
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-68 Add IP Interface Assembly 6 7. Typ e a valid IP ad d ress for the IP Interfac e server in the IP Address: field . 8. Typ e the ap p rop riate sub net mask in the Subnet Mask: field. NOTE: Not all networks req uire step s 9 throug h 18. Chec k with the loc al network ad ministrator to determine whic h are req uired . 9. If you use g ateways, type the IP ad d ress of the d efault g ateway for the IP Interfac e server in the Default Gateway: field. 10. Clic k on the DNS tab and verify that the d omain DNS server is c orrec t.