Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-39 Release 5/6si to Release 8r 3 Figure 3-14. Fiber Optic Connections Through Center Stage Switch Figure Notes 1. Cabinet 1 PPN with 1 Switc h Nod e 2. Cabinet Stac k 2-16 EPN 3. Metallic Cab le (H600-278)4. Ad d Links to EPNs in Alternating Ord er (20, 3, 19, 4, 18, 5, and so forth) 5. To ad d itional EPNs
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-40 Release 5/6si to Release 8r 3 For 1 to 15 High Reliability EPNs. 1. Behind the PPN c ab inet. See Figure 3-15 : a. Install a lig htwave transc eiver on c ab le c onnec tor at slot 1E02. b . Install a lig htwave transc eiver on c ab le c onnec tor at slot 1C02. c . Connec t 1 end of the metallic interc arrier c ab le to the lig htwave transc eiver at slot 1E02. d . Route the interc arrier c ab le from the lig htwave transc eiver to the c ab inet’s c ab le tray and up ward to c arrier ‘‘C. e. Connec t the other end of the interc arrier c ab le to the lig htwave transc eiver at slot 1C02. f. Install a lig htwave transc eiver on c ab le c onnec tor at slot 1E20. g . Install a lig htwave transc eiver on c ab le c onnec tor at slot 1D02. h. Connec t 1 end of the metallic interc arrier c ab le to the lig htwave transc eiver at slot 1E20. i. Route the interc arrier c ab le from the lig htwave transc eiver to the c ab inet’s c ab le tray and up ward to c arrier ‘‘D. j. Connec t the other end of the interc arrier c ab le to the lig htwave transc eiver at slot 1D02. k. Attac h the interc arrier c ables (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. 2. Behind switc h node carrier E of PPN c abinet 1. See Figure 3-15 : a. For eac h EPN, install 1 lig htwave transc eiver on a c ab le c onnec tor with the following ord er of slots: 1E03, 1E19, 1E04, 1E18, 1E05, 1E17, and so forth. b . Connec t 1 end of eac h fiber op tic c able to eac h lig htwave transc eiver, just installed . c . Carefully attac h the fib er optic c ab les (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le-tie p ositions. d . Behind c ontrol c ab inet A of eac h sing le-c arrier EPN: e. Install the same kind of lig htwave transc eiver on c ab le c onnec tor at slot A01. f. Connec t the other end of the fiber op tic c able to the lig htwave transc eiver, just installed , at slot A01. g . Coil the surp lus leng th of fiber op tic c ab le, and p lac e the c oil either in the c ab le manag er or on the b ottom shelf (hold ing the p ower sup p ly) of the PPN c ab inet.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-41 Release 5/6si to Release 8r 3 ] Figure 3-15. Fiber Optic Connections Through Center Stage Switch Figure Notes 1. Cabinet 1 PPN with 1 Switc h Nod e 2. Cabinet Stac k 2-16 EPN 3. H600-278 Metallic Cable4. Ad d Links to EPNs in Alternating Order (3, 19, 4, 18, 5, 17, and so forth) 5. To Add itional EPNs
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-42 Release 5/6si to Release 8r 3 For 1 to 15 Critical Reliability EPNs. 1. Behind the PPN c ab inet. See Figure 3-16 : a. Install a lig htwave transc eiver on c ab le c onnec tor at slot 1E01. b . Install a lig htwave transc eiver on c ab le c onnec tor at slot 1E02. c . Connec t the metallic intrac arrier c ab le to the lig htwave transc eivers at slots 1E01 and 1E02. d . Install a lig htwave transc eiver on c ab le c onnec tor at slot 1D01. e. Install a lig htwave transc eiver on c ab le c onnec tor at slot 1D02. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eivers f. Connec t the metallic intrac arrier c ab le to the lig htwave transc eivers at slots 1D01 and 1D02. 2. Behind switc h node carrier E of PPN c abinet 1: a. For eac h EPN, install 1 lig htwave transc eiver on a c ab le c onnec tor with the following ord er of slots: 1E20, 1E03, 1E19, 1E04, 1E18, 1E05, and so forth. b . Connec t 1 end of eac h fiber op tic c able to eac h lig htwave transc eiver, just installed . c . Carefully attac h the fib er optic c ab les (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le-tie p ositions. 3. Behind c ontrol c ab inet A of eac h sing le-c arrier EPN: a. Install a lig htwave transc eiver on c ab le c onnec tor at slot A01. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver b . Connec t the other end of the fiber op tic c able to the lig htwave transc eiver, just installed , at slot A01. c . Carefully attac h the fib er op tic c ab le (with c ab le ties) to the rear c overs of the EPN stac k. d . Coil the surp lus leng th of fiber op tic c ab le, and p lac e the c oil either in the c ab le manag er or on the b ottom shelf (hold ing the p ower sup p ly) of the PPN c ab inet.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-43 Release 5/6si to Release 8r 3 4. Behind switc h nod e c arrier D of PPN c ab inet 1: a. For eac h EPN, install 1 lig htwave transc eiver on a c ab le c onnec tor with the following ord er of slots: 1E20, 1E03, 1E19, 1E04, 1E18, 1E05, and so forth. b . Connec t 1 end of eac h fiber op tic c able to eac h lig htwave transc eiver, just installed . c . Carefully attac h the fib er optic c ab les (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. 5. Behind p ort c ab inet B of eac h sing le-c arrier EPN: a. Install a lig htwave transc eiver on c ab le c onnec tor at slot B02. NOTE: Attenuators may be required for single mode fiber using a 300A Lightwave Transc eiver b . Connec t the other end of the fiber op tic c able to the lig htwave transc eiver, just installed , at slot B02. c . Carefully attac h the fib er op tic c ab le (with c ab le ties) to the rear c overs of the EPN stac k. d . Coil up the surp lus leng th of fib er op tic c ab le, and p lac e the c oil either in the c ab le manag er or on the b ottom shelf (hold ing the p ower sup p ly) of the PPN c ab inet.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-44 Release 5/6si to Release 8r 3 Figure 3-16. Fiber Optic Connections Through Center Stage Switch Figure Notes 1. Cabinet 1 with 1 Dup lex Switc h Node 2. Cabinet Stac k 2-16 EPN 3. H600-278 Metallic Cable4. Ad d Links to EPNs in Alternating Ord er (20, 3, 19, 4, 18, 5, and so forth) 5. Ad d Links to EPNs in Alternating Ord er (20, 3, 19, 4, 18, 5, and so forth) 6. To ad ditional EPNs
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-45 Release 5/6si to Release 8r 3 DS1 CONV-Remoted Cabinets The d istanc e b etween the DS1 fac ilities and assoc iated eq uip ment room hard ware and c ab ling is a maximum of ap p roximately 200 c irc uit miles (322 km) for analog voic e and 500 c irc uit miles (805 km) for d ig ital (no analog voic e stations). NOTE: These limits for DS1 remoting is the maximum d istanc e b etween any 2 p ort networks in a Release 8r system with either direc t or switc hed p ort network c onnec tions with a TN1654 DS1 Converter Circ uit p ac k. Dig ital p ub lic network tie trunk fac ilities provid e the end -to-end c onnec tivity b etween the p ort networks. For either typ e of p ort network (PPN or EPN), a TN1654 DS1 Converter c irc uit p ac k serves as the p ort network interfac e to the DS1 fac ilities. As a PPN interfac e, a TN1654 DS1-CONV c an resid e in either: nA p ort c arrier (in any p ort slot) nA switch-nod e c arrier (in p ort slot “ 1” or “21”) As an EPN interfac e, a TN1654 DS1 CONV c an reside in an expansion c ontrol carrier (in any p ort slot). DS1 Cabling within the Local Port Networks. Use the running list that ac c omp anies the up g rad e eq uip ment to d etermine whic h c ab le c onnec ts where. The following parag rap hs only p rovid e c onc ep tual information ab out wiring a DS1 Converter interfac e either to an exp ansion interfac e or to a switc h nod e interfac e, not step -b y-step p roc ed ures for wiring a sp ec ific Release 8r system. NOTE: It is imp ortant to lab el every c ab le installed . A c ab le c onnec ts eac h DS1 CONV either to the ap p rop riate TN570 exp ansion interfac e (for a d irec t c onnec tion to another p ort network) or to the ap p rop riate TN573B SN Interfac e (for a switc hed c onnec tion to another p ort network). NOTE: These c ab les usually c onnec t to TN570 exp ansion interfac es (alread y installed ) for d irec t c onnec tions b etween the new PPN and either 1 or 2 EPN s . On the DS1 CONV side, a 4C retainer b ind s this shield ed c ab le to the DS1 CONV p ort c onnec tor. On the EI/SNI sid e, a 4B retainer b ind s the c ab le to the EI/SNI p ort c onnec tor. The DS1 CONV-to-EI/SNI c able also p rovid es a p ig gy-b ac k c onnec tor enab ling sub seq uent ac c ess to the p ublic network.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-46 Release 5/6si to Release 8r 3 Table 3-5 lists the c ab le numb ers and leng ths for the p ossib le c onnec tions. DS1 CONV Cabling to the Public Network. Use the running list that ac c omp anies the up g rad e eq uip ment to d etermine whic h c ab le c onnec ts where. The following parag rap hs only p rovid e c onc ep tual information ab out wiring a DS1 CONV interfac e to a wall-field b loc k, not step -b y-step p roc ed ures for wiring a sp ec ific Release 8r system. If alread y c onnec ted to either an exp ansion or switc h nod e interfac e, a DS1 CONV c irc uit p ac k alread y resid es either in an EPN exp ansion c ontrol c arrier or in a PPN p ort c arrier or switc h nod e c arrier. Dep end ing on the traffic req uirements b etween the 2 p ort networks, a 25-foot (7.625 m) H600-348 c ab le extend s from the p igg y-b ac k c onnec tor (on eac h DS1 CONV-to-EI/SNI c ab le) to from 1 to 4 CSUs. This c ab le b ranc hes to four 15-p in sub miniature D-typ e c onnec tors (lab eled “ 01” to “ 04” ) to make the CSU c onnec tions. Then, in turn, the CSUs c onnec t to the wall-field b loc k (c orresp onding to the eq uip ment loc ation of the DS1 CONV) at p ort c onnec tions “ 8,” “ 7,” “ 6,” and “ 5” (in d esc end ing ord er). Neg lec ting overhead , this wiring arrang ement c an p rovid e PN-to-PN c ommunic ation at the b and wid th of up to 4 DS1 CONV sp ans (1.544 Mb ps eac h). Between eac h p ort network’s wall field , the p ort networks c ommunic ate ac ross leased lines in the p ub lic network. Connect Power and Ground 1. Rec onnec t the 6 AWG (#40) (4.1 mm2) c ab inet ground wire to the sing le-p oint g round b ar on the c ab inet. 2. Rec onnec t the 10 AWG (#25) (2.6 mm 2) c oup led bond ing c ond uc tor wire. 3. Rec onnec t the c ab inet p ower c ord s at the rear of eac h c ab inet. Table 3-5. Numbers and Lengths of DS1 CONV-to-EI/SNI Cables Connection Type Comcode Number Length Within same c arrier 847245750 1 foot (0.305 m) Between 2 c arriers in same port network846448768 5.5 feet (1.677 m) Between 2 c arriers in ad jac ent networks846448776, and one 846885259 b rac ket1 foot (0.3.5 m) (used with two 9823As, & one 20-foot (6.1 m) fib er op tic c ab le)
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-47 Release 5/6si to Release 8r 3 Verify Usable Circuit Pack Vintages 1. Verify every circuit pack reused in the upgrade conforms to the usable vintag e requirements for a Release 8r system (see Reference Guide for Circ uit Pac k Vintag es and Chang e Notic es ). Install System Access Ports 1. Before c onnec ting various end p oints that use EIA interfac es to the system, install up to 8 loop -around c onnec tions for Mod e 2-to-Mod e 3 (and vic e versa) d ata c onversion. From the outg oing p ersp ec tive of the system c ommunic ating with an EIA end p oint, these loop -around c onnec tions c onvert Mod e 3 d ata (c irc uit-switc hed p ac ket data, with und efined b it rates and pac ket sp ec ific ations) to Mod e 2 d ata (low-sp eed , usually async hronous, d ata at rates of 300 to 19,200 b p s) b y: nAc c ep ting Mode 3 d ata off the LAN bus (from the SPE) at a TN553 Pac ket Data Line c irc uit p ac k, where Mod e 3-to-Mod e 2 c onversion is d one nRouting the c onverted data throug h the c ross-c onnec t field and b ac k to a TN726B Data Line where the equivalent Mod e 2 d ata c an ac c ess the TDM b us, for sub seq uent routing to an EIA end p oint The end p oints that use these EIA interfac es and , therefore, req uire the Mod e 2-to-Mod e 3 c onversion inc lud e: nGeneric 3 Manag ement Ap p lic ations (G3-MA) nRemote Manag ement Terminal nBasic Call Manag ement System (BCMS) terminal nCall Detail Rec ord ing Unit (CDRU)/Centralized Attend ant Servic e Plus (CAS+ ) nProp erty Manag ement System (PMS) nPri n t e rs Reseat DEFINITY LAN Gateway System 1. Reseat the DEFINITY LAN Gateway assembly into the b ac kp lane. Reseat DEFINITY AUDIX System 1. Reseat the AUDIX assemb ly to its b ac kp lane c onnec tors. Remove Emergency Transfer Ground Wire 1. Remove the g round wire from the emerg enc y transfer unit.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5si/R6si to R8r EPN and Adding Memory 3-48 Release 5/6si to Release 8r 3 Reboot the System 1. Connec t the manag ement terminal to the TERMINAL c onnec tor on the rear o f PPN c ontrol c arrier “ A,” or install the G3-MA ac c ord ing to DEFINITY Communic ations System Generic 3 Manag ement Ap p lic ations — Operations , 585-229-202. 2. Insert the new Release 8r system removab le media in the optic al d rive. 3. Behind eac h EPN c ab inet, set the c irc uit b reaker to ON. 4. At the PPN p ower d istribution unit, set the main c irc uit b reaker to ON. 5. The system p erforms a reset level 4 reb ooting p roc ess, load ing b lank translations from the d isk. Reb ooting takes 5 to 11 minutes. 6. Type reset system 4 and p ress En te r. This instructs the system to p erform a reset level 4 reb ooting p roc ess, load ing the up g raded STS translations from the new removab le media. Reb ooting takes 5 to 11 minutes. 7. Log in as craft at the login: p rompt on the terminal and set the time to ensure the system is b ooted p rop erly. 8. After ab out 2 minutes, typ e status spe and p ress En te r. The standby handshake field must b e up b efore c ontinuing with the up g rad e. 9. Type reset spe standby 4 and press En te r. Th i s c h a n g e s t h e s t a n d b y SPE to ac tive and vic e versa. This takes ab out 10 minutes. 10. If the system is hig h or c ritic al reliab ility, typ e status spe and press En t e r. Th e handshake , refresh , and shadowing field s must b e up b efore c ontinuing with the up g rad e. Also, the stand b y sid e must b e in-service . The heartb eat on the stand b y SPE flashes yellow. 11. Typ e restore disk [spe-a or both] full and press En t e r. This instructs the system to write the upgraded STS translation information from memory to the d isk(s). Restart DEFINITY LAN Gateway System 1. Log onto the DEFINITY LAN Gateway. 2. When the main menu ap p ears, selec t Maintenanc e. 3. Select Reset System from the Maintenanc e menu. 4. Select Restart System from the Reset System menu. Label Main Distribution Frame 1. Lab el the MDF with the new PN numb er of the Release 8r EPN. The STS software upg rad e assig ns the next PN numb er, after the hig hest numb ered PN in the Release 5/6si system, to the up g raded EPN.