    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-39 Release 5/6si to Release 8r 
    3
    Figure 3-14. Fiber Optic Connections Through Center Stage Switch Figure Notes
    1. Cabinet 1 PPN with 1 Switc h Nod e
    2. Cabinet Stac k 2-16 EPN
    3. Metallic  Cab le (H600-278)4. Ad d  Links to EPNs in Alternating  
    Ord er (20, 3, 19, 4, 18, 5, and  so forth)
    5. To ad d itional EPNs 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-40 Release 5/6si to Release 8r 
    3
    For 1 to 15 High Reliability EPNs. 
    1. Behind  the PPN c ab inet. See Figure 3-15
    :
    a. Install a lig htwave transc eiver on c ab le c onnec tor at slot 1E02.
    b . Install a lig htwave transc eiver on c ab le c onnec tor at slot 1C02.
    c . Connec t 1 end  of the metallic  interc arrier c ab le to the lig htwave 
    transc eiver at slot 1E02.
    d . Route the interc arrier c ab le from the lig htwave transc eiver to the 
    c ab inet’s c ab le tray and  up ward  to c arrier ‘‘C.
    e. Connec t the other end  of the interc arrier c ab le to the lig htwave 
    transc eiver at slot 1C02.
    f. Install a lig htwave transc eiver on c ab le c onnec tor at slot 1E20.
    g . Install a lig htwave transc eiver on c ab le c onnec tor at slot 1D02.
    h. Connec t 1 end  of the metallic  interc arrier c ab le to the lig htwave 
    transc eiver at slot 1E20.
    i. Route the interc arrier c ab le from the lig htwave transc eiver to the 
    c ab inet’s c ab le tray and  up ward  to c arrier ‘‘D.
    j. Connec t the other end  of the interc arrier c ab le to the lig htwave 
    transc eiver at slot 1D02.
    k. Attac h the interc arrier c ables (with c ab le ties) to the wall of the 
    c ab le tray at the b uilt-in c ab le tie p ositions.
    2. Behind switc h node carrier E of PPN c abinet 1. See Figure 3-15
    :
    a. For eac h EPN, install 1 lig htwave transc eiver on a c ab le c onnec tor 
    with the following  ord er of slots: 1E03, 1E19, 1E04, 1E18, 1E05, 
    1E17, and so forth.
    b . Connec t 1 end  of eac h fiber op tic  c able to eac h lig htwave 
    transc eiver, just installed .
    c . Carefully attac h the fib er optic  c ab les (with c ab le ties) to the wall of 
    the c ab le tray at the b uilt-in c ab le-tie p ositions.
    d . Behind  c ontrol c ab inet A of eac h sing le-c arrier EPN:
    e. Install the same kind  of lig htwave transc eiver on c ab le c onnec tor at 
    slot A01.
    f. Connec t the other end  of the fiber op tic  c able to the lig htwave 
    transc eiver, just installed , at slot A01.
    g . Coil the surp lus leng th of fiber op tic  c ab le, and  p lac e the c oil either 
    in the c ab le manag er or on the b ottom shelf (hold ing  the p ower 
    sup p ly) of the PPN c ab inet. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-41 Release 5/6si to Release 8r 
    3
    ]
    Figure 3-15. Fiber Optic Connections Through Center Stage Switch Figure Notes
    1. Cabinet 1 PPN with 1 Switc h Nod e
    2. Cabinet Stac k 2-16 EPN
    3. H600-278 Metallic  Cable4. Ad d  Links to EPNs in Alternating  
    Order (3, 19, 4, 18, 5, 17, and  so forth)
    5. To Add itional EPNs 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-42 Release 5/6si to Release 8r 
    3
    For 1 to 15 Critical Reliability EPNs. 
    1. Behind  the PPN c ab inet. See Figure 3-16
    :
    a. Install a lig htwave transc eiver on c ab le c onnec tor at slot 1E01.
    b . Install a lig htwave transc eiver on c ab le c onnec tor at slot 1E02.
    c . Connec t the metallic  intrac arrier c ab le to the lig htwave transc eivers 
    at slots 1E01 and  1E02.
    d . Install a lig htwave transc eiver on c ab le c onnec tor at slot 1D01.
    e. Install a lig htwave transc eiver on c ab le c onnec tor at slot 1D02.
    NOTE:
    Attenuators may be required for single mode fiber using a 
    300A Lightwave Transc eivers
    f. Connec t the metallic  intrac arrier c ab le to the lig htwave transc eivers 
    at slots 1D01 and  1D02.
    2. Behind switc h node carrier E of PPN c abinet 1:
    a. For eac h EPN, install 1 lig htwave transc eiver on a c ab le c onnec tor 
    with the following  ord er of slots: 1E20, 1E03, 1E19, 1E04, 1E18, 
    1E05, and so forth.
    b . Connec t 1 end  of eac h fiber op tic  c able to eac h lig htwave 
    transc eiver, just installed .
    c . Carefully attac h the fib er optic  c ab les (with c ab le ties) to the wall of 
    the c ab le tray at the b uilt-in c ab le-tie p ositions.
    3. Behind  c ontrol c ab inet A of eac h sing le-c arrier EPN:
    a. Install a lig htwave transc eiver on c ab le c onnec tor at slot A01.
    NOTE:
    Attenuators may be required for single mode fiber using a 
    300A Lightwave Transc eiver
    b . Connec t the other end  of the fiber op tic  c able to the lig htwave 
    transc eiver, just installed , at slot A01.
    c . Carefully attac h the fib er op tic  c ab le (with c ab le ties) to the rear 
    c overs of the EPN stac k.
    d . Coil the surp lus leng th of fiber op tic  c ab le, and  p lac e the c oil either 
    in the c ab le manag er or on the b ottom shelf (hold ing  the p ower 
    sup p ly) of the PPN c ab inet. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-43 Release 5/6si to Release 8r 
    3
    4. Behind  switc h nod e c arrier D of PPN c ab inet 1:
    a. For eac h EPN, install 1 lig htwave transc eiver on a c ab le c onnec tor 
    with the following  ord er of slots: 1E20, 1E03, 1E19, 1E04, 1E18, 
    1E05, and so forth.
    b . Connec t 1 end  of eac h fiber op tic  c able to eac h lig htwave 
    transc eiver, just installed .
    c . Carefully attac h the fib er optic  c ab les (with c ab le ties) to the wall of 
    the c ab le tray at the b uilt-in c ab le tie p ositions.
    5. Behind  p ort c ab inet B of eac h sing le-c arrier EPN:
    a. Install a lig htwave transc eiver on c ab le c onnec tor at slot B02.
    NOTE:
    Attenuators may be required for single mode fiber using a 
    300A Lightwave Transc eiver
    b . Connec t the other end  of the fiber op tic  c able to the lig htwave 
    transc eiver, just installed , at slot B02.
    c . Carefully attac h the fib er op tic  c ab le (with c ab le ties) to the rear 
    c overs of the EPN stac k.
    d . Coil up  the surp lus leng th of fib er op tic  c ab le, and  p lac e the c oil 
    either in the c ab le manag er or on the b ottom shelf (hold ing  the 
    p ower sup p ly) of the PPN c ab inet. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-44 Release 5/6si to Release 8r 
    3
    Figure 3-16. Fiber Optic Connections Through Center Stage Switch Figure Notes
    1. Cabinet 1 with 1 Dup lex Switc h 
    Node
    2. Cabinet Stac k 2-16 EPN
    3. H600-278 Metallic  Cable4. Ad d  Links to EPNs in Alternating  Ord er 
    (20, 3, 19, 4, 18, 5, and  so forth)
    5. Ad d  Links to EPNs in Alternating  Ord er 
    (20, 3, 19, 4, 18, 5, and  so forth)
    6. To ad ditional EPNs 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-45 Release 5/6si to Release 8r 
    3
    DS1 CONV-Remoted Cabinets
    The d istanc e b etween the DS1 fac ilities and  assoc iated eq uip ment room 
    hard ware and  c ab ling  is a maximum of ap p roximately 200 c irc uit miles (322 km) 
    for analog  voic e and  500 c irc uit miles (805 km) for d ig ital (no analog  voic e 
    stations).
    NOTE:
    These limits for DS1 remoting  is the maximum d istanc e b etween any 2 p ort 
    networks in a Release 8r system with either direc t or switc hed  p ort network 
    c onnec tions with a TN1654 DS1 Converter Circ uit p ac k. 
    Dig ital p ub lic  network tie trunk fac ilities provid e the end -to-end  c onnec tivity 
    b etween the p ort networks. For either typ e of p ort network (PPN or EPN), a 
    TN1654 DS1 Converter c irc uit p ac k serves as the p ort network interfac e to 
    the DS1 fac ilities. As a PPN interfac e, a TN1654 DS1-CONV c an resid e in 
    either:
    nA p ort c arrier (in any p ort slot)
    nA switch-nod e c arrier (in p ort slot “ 1” or “21”)
    As an EPN interfac e, a TN1654 DS1 CONV c an reside in an expansion c ontrol 
    carrier (in any p ort slot).
    DS1 Cabling within the Local Port Networks. 
    Use the running list that 
    ac c omp anies the up g rad e eq uip ment to d etermine whic h c ab le c onnec ts where. 
    The following parag rap hs only p rovid e c onc ep tual information ab out wiring  a 
    DS1 Converter interfac e either to an exp ansion interfac e or to a switc h nod e 
    interfac e, not step -b y-step  p roc ed ures for wiring  a sp ec ific  Release 8r system.
    NOTE:
    It is imp ortant to lab el every c ab le installed . 
    A c ab le c onnec ts eac h DS1 CONV either to the ap p rop riate TN570 exp ansion 
    interfac e (for a d irec t c onnec tion to another p ort network) or to the ap p rop riate 
    TN573B SN Interfac e (for a switc hed  c onnec tion to another p ort network).
    NOTE:
    These c ab les usually c onnec t to TN570 exp ansion interfac es (alread y 
    installed ) for d irec t c onnec tions b etween the new PPN and  either 1 or 2 
    EPN s .
    On the DS1 CONV side, a 4C retainer b ind s this shield ed  c ab le to the DS1 CONV 
    p ort c onnec tor. On the EI/SNI sid e, a 4B retainer b ind s the c ab le to the EI/SNI 
    p ort c onnec tor. The DS1 CONV-to-EI/SNI c able also p rovid es a p ig gy-b ac k 
    c onnec tor enab ling  sub seq uent ac c ess to the p ublic  network. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-46 Release 5/6si to Release 8r 
    3
    Table 3-5 lists the c ab le numb ers and  leng ths for the p ossib le c onnec tions. 
    DS1 CONV Cabling to the Public Network. 
    Use the running  list that 
    ac c omp anies the up g rad e eq uip ment to d etermine whic h c ab le c onnec ts where. 
    The following parag rap hs only p rovid e c onc ep tual information ab out wiring  a 
    DS1 CONV interfac e to a wall-field  b loc k, not step -b y-step  p roc ed ures for wiring  
    a sp ec ific  Release 8r system.
    If alread y c onnec ted  to either an exp ansion or switc h nod e interfac e, a DS1 
    CONV c irc uit p ac k alread y resid es either in an EPN exp ansion c ontrol c arrier or 
    in a PPN p ort c arrier or switc h nod e c arrier.
    Dep end ing  on the traffic  req uirements b etween the 2 p ort networks, a 25-foot 
    (7.625 m) H600-348 c ab le extend s from the p igg y-b ac k c onnec tor (on eac h DS1 
    CONV-to-EI/SNI c ab le) to from 1 to 4 CSUs. This c ab le b ranc hes to four 15-p in 
    sub miniature D-typ e c onnec tors (lab eled  “ 01”  to “ 04” ) to make the CSU 
    c onnec tions. Then, in turn, the CSUs c onnec t to the wall-field  b loc k 
    (c orresp onding  to the eq uip ment loc ation of the DS1 CONV) at p ort c onnec tions 
    “ 8,”  “ 7,”  “ 6,”  and  “ 5”  (in d esc end ing  ord er).
    Neg lec ting  overhead , this wiring  arrang ement c an p rovid e PN-to-PN 
    c ommunic ation at the b and wid th of up  to 4 DS1 CONV sp ans (1.544 Mb ps 
    eac h). Between eac h p ort network’s wall field , the p ort networks c ommunic ate 
    ac ross leased  lines in the p ub lic  network.
    Connect Power and Ground
    1. Rec onnec t the 6 AWG (#40) (4.1 mm2) c ab inet ground wire to the 
    sing le-p oint g round  b ar on the c ab inet.
    2. Rec onnec t the 10 AWG (#25) (2.6 mm
    2) c oup led bond ing  c ond uc tor wire.
    3. Rec onnec t the c ab inet p ower c ord s at the rear of eac h c ab inet.
    Table 3-5. Numbers and Lengths of DS1 CONV-to-EI/SNI Cables
    Connection Type Comcode Number Length
    Within same c arrier 847245750 1 foot (0.305 m)
    Between 2 c arriers in 
    same port network846448768 5.5 feet (1.677 m)
    Between 2 c arriers in 
    ad jac ent networks846448776, and  one 
    846885259 b rac ket1 foot (0.3.5 m) (used  with two 
    9823As, & one 20-foot (6.1 m) 
    fib er op tic  c ab le) 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-47 Release 5/6si to Release 8r 
    3
    Verify Usable Circuit Pack Vintages
    1. Verify every circuit pack reused in the upgrade conforms to the usable 
    vintag e requirements for a Release 8r system (see 
    Reference Guide for 
    Circ uit Pac k Vintag es and  Chang e Notic es
    ).
    Install System Access Ports
    1. Before c onnec ting  various end p oints that use EIA interfac es to the system, 
    install up  to 8 loop -around  c onnec tions for Mod e 2-to-Mod e 3 (and  vic e 
    versa) d ata c onversion.
    From the 
    outg oing p ersp ec tive of the system c ommunic ating  with an EIA 
    end p oint, these loop -around  c onnec tions c onvert Mod e 3 d ata (c irc uit-switc hed  
    p ac ket data, with und efined  b it rates and pac ket sp ec ific ations) to Mod e 2 d ata 
    (low-sp eed , usually async hronous, d ata at rates of 300 to 19,200 b p s) b y:
    nAc c ep ting  Mode 3 d ata off the LAN bus (from the SPE) at a TN553 Pac ket 
    Data Line c irc uit p ac k, where Mod e 3-to-Mod e 2 c onversion is d one
    nRouting  the c onverted  data throug h the c ross-c onnec t field  and  b ac k to a 
    TN726B Data Line where the equivalent Mod e 2 d ata c an ac c ess the TDM 
    b us, for sub seq uent routing  to an EIA end p oint
    The end p oints that use these EIA interfac es and , therefore, req uire the Mod e 
    2-to-Mod e 3 c onversion inc lud e:
    nGeneric  3 Manag ement Ap p lic ations (G3-MA)
    nRemote Manag ement Terminal 
    nBasic  Call Manag ement System (BCMS) terminal
    nCall Detail Rec ord ing  Unit (CDRU)/Centralized Attend ant Servic e Plus 
    (CAS+ )
    nProp erty Manag ement System (PMS)
    nPri n t e rs
    Reseat DEFINITY LAN Gateway System
    1. Reseat the DEFINITY LAN Gateway assembly into the b ac kp lane.
    Reseat DEFINITY AUDIX System
    1. Reseat the AUDIX assemb ly to its b ac kp lane c onnec tors.
    Remove Emergency Transfer Ground Wire 
    1. Remove the g round  wire from the emerg enc y transfer unit. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-48 Release 5/6si to Release 8r 
    3
    Reboot the System
    1. Connec t the manag ement terminal to the TERMINAL c onnec tor on the rear 
    o f  PPN c ontrol c arrier “ A,”  or install the G3-MA ac c ord ing  to 
    DEFINITY 
    Communic ations System Generic  3 Manag ement Ap p lic ations 
    — 
    Operations
    , 585-229-202.
    2. Insert the new Release 8r system removab le media in the optic al d rive.
    3. Behind  eac h EPN c ab inet, set the c irc uit b reaker to ON.
    4. At the PPN p ower d istribution unit, set the main c irc uit b reaker to ON.
    5. The system p erforms a reset level 4 reb ooting  p roc ess, load ing  b lank 
    translations from the d isk. Reb ooting  takes 5 to 11 minutes.
    6. Type reset system 4 
    and  p ress 
    En te r. This instructs the system to p erform 
    a reset level 4 reb ooting  p roc ess, load ing  the up g raded  STS translations 
    from the new removab le media. Reb ooting  takes 5 to 11 minutes.
    7. Log in as craft
     at the login:
     p rompt on the terminal and  set the time to 
    ensure the system is b ooted  p rop erly.
    8. After ab out 2 minutes, typ e status spe
     and  p ress 
    En te r. The standby 
    handshake
     field  must b e up
     b efore c ontinuing  with the up g rad e.
    9. Type reset spe standby 4
     and press 
    En te r.  Th i s c h a n g e s  t h e  s t a n d b y  SPE 
    to ac tive and  vic e versa. This takes ab out 10 minutes.
    10. If the system is hig h or c ritic al reliab ility, typ e status spe
     and press 
    En t e r. 
    Th e  handshake
    , refresh
    , and  shadowing
     field s must b e up
     b efore 
    c ontinuing  with the up g rad e. Also, the stand b y sid e must b e 
    in-service
    . The heartb eat on the stand b y SPE flashes yellow.
    11. Typ e restore disk [spe-a or both] full
     and press 
    En t e r. This instructs 
    the system to write the upgraded STS translation information from memory 
    to the d isk(s).
    Restart DEFINITY LAN Gateway System
    1. Log  onto the DEFINITY LAN Gateway. 
    2. When the main menu ap p ears, selec t 
    Maintenanc e.
    3. Select 
    Reset System from the Maintenanc e menu.
    4. Select 
    Restart System from the Reset System menu.
    Label Main Distribution Frame
    1. Lab el the MDF with the new PN numb er of the Release 8r EPN. The STS 
    software upg rad e assig ns the next PN numb er, after the hig hest 
    numb ered PN in the Release 5/6si system, to the up g raded  EPN. 
    						