Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-39 Remove an EPN Cabinet from an Existing System 6 All Installations 1. When the system reset is finished, type status port-network 2 and press En t e r. The Port Network Status sc reen ap p ears. Verify that PNC Ac tive is “ up ” and that the Servic e State is “ in.” 2. A Span LED, on the front of the DS1 Converter circuit pack, must be off for eac h inac tive fac ility administered . For examp le, if Fac ility A and Fac ility B are unad ministered , then the top 2 Sp an LEDs on the c irc uit p ac k must b e off. If the yellow LEDs are on, then p rob lems were enc ountered d uring the unad ministration of hard ware. Sp an LEDs assoc iated with ad ministered fac ilities (C and D, in this examp le) should b e on. Removing the Hardware 1. Be sure that you have unad ministered the trunks, attend ant c onsoles, voic e terminals, and d ata mod ules assoc iated with the p ort c irc uit pac ks in the EPN c ab inet. 2. Remove the fib er op tic c ab les from the fib er transc eivers at b oth end s of the fib er sp an. Carefully c oil the fib er op tic c ables. Avoid b end ing c ab les to a rad ius smaller than 1.5 inc hes (3.8 c m). 3. Remove the fib er transc eivers from the DS1 and /or DS1 c onverter c irc uit p ac ks at b oth end s of eac h fib er sp an. 4. Remove the 25-p air c ab les from the c onnec tor p anel on eac h c arrier of the EPN. 5. Type remove cabinet and p ress En t e r. This removes the EPN c ab inet ad ministration. 6. Remove the p ower c ord s from the p ower units in eac h c arrier in the EPN and remove the AC power c ord or DC p ower wires. 7. Chec k the ground ing sc heme for the c ab inets. Perform the following : a. If any c ab inet ground wires c onnec t in series b etween the EPN c ab inet and any other c ab inet, remove the wires from the EPN c ab inet and c onnec t them to the next c abinet in the g round p lane. !CAUTION: Never leave c ab inets ungrounded . When a ground wire is removed from a series-c onnec ted c abinet, the g round p lane b ec omes op en with respec t to all sub seq uent c ab inets. b . If any c abinet g round wires c onnec t in parallel to other c ab inets, or c onnec t d irec tly to the AC p ower panel g round or other ap proved g round , remove the wire from eac h end of the g round sp an. 8. Carefully remove the EPN c ab inet. The c ab inet may weig h as muc h as 800 p ound s. Use c aution.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-40 Remove an EPN Cabinet from an Existing System 6 9. Type change system-parameters features and p ress En t e r. Use this sc reen to c hang e the TTI field b ac k to its p revious value b efore the up g rad e. 10. When finished , p lac e d ust c overs over all exp osed fib er c oup ling s that remain after the fib er op tic c ab les are removed . 11. If any fib er op tic c ab les were removed from Lightg uide Interc onnec t Units (LIUs) or Fib er Patc h Panels, remove the assoc iated c able lab eling . This will prevent c onfusion if existing fib er is later moved. 12. Return all unused equipment (not owned by the customer) to Lucent Tec hnolog ies ac c ord ing to the req uirements outlined in: BCS/Material Log istic s, MSL/Attend ed Stoc king Loc ations Method s and Proc ed ures for Basic Material Returns Troubleshooting Message Waiting Lamps On This usually means that all affec ted p ort-related translations were not unad ministered . 1. Type clear amw all and press En te r. This c lears the messag e waiting lamp for the sp ec ified extension. 2. Rep eat the c ommand for eac h extension with a lit messag e waiting lamp.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-41 Add External Modem to EPN 6 Add External Modem to EPN U.S. Robotics Model USR 33.6 EXT External Modem Figure 6-18. Connect External Modem to EPN 1. Connec t an RS-232 c ab le to the modem. See Figure 6-18 . NOTE: In the following step s, a PC with Wind ows 95 or Wind ows NT 4.0 may b e sub stituted for the d umb terminal. Use the Hyp erterminal (terminal emulation) ap p lic ation. 2. Connec t the op p osite end of the RS-232 c ab le to a d umb terminal. 3. Set the d umb terminal to full d up lex mod e. 4. Type AT&N6 to set the baud rate to 9600. NOTE: The mod em c onnec ts at 9600 b aud b ut throug hp ut is at 1200 b aud . 5. Type AT & W 0 to save the setting into non-volatile RAM. 6. Set Switc h 5 to the OFF (up ) p osition to disab le auto answer. 7. Disc onnec t the RS-232 c ab le from the terminal and c onnec t it to the TERMINAL c onnec tor on the rear of the system c ab inet. Figure Notes: 1. U.S. Rob otic s External Mod em 2. RS-232 Cab le 3. Exp ansion Port Network cydfepnm KLC 100397 TERM INAL 1 2 3
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-42 Add DCS Interface 6 Add DCS Interface Systems in a Distrib uted Communic ations System (DCS) network are interc onnec ted b y b oth tie trunks (for voic e c ommunic ations) and d ata links (for c ontrol and transp arent feature information). These d ata links, also c alled DCS sig naling links, supp ort the feature transp arenc y. Various sub sets (dep end ing on the sp ec ific c onfig uration) of DS1 Interfac e c irc uit p ac ks (inc lud ing TN464F, TN767E, and TN760E) p rovide the voic e-c ommunic ations interfac e. Meanwhile, the d ata link interfac e (b etween the p roc essor and the p hysic al sig naling link) is p rovid ed b y (or throug h) a TN799 Control-LAN c irc uit p ac k. In some c onfig urations, the TN799 passes the sig naling information over a sep arate 10BaseT TCP/IP network (usually via a hub ). For use with 10BaseT, c onnec t the ap p rop riate p ins of the I/O field to the hub . For p inouts and d iagrams, refer to the installation manual for your c ab inet typ e. In other c onfigurations, the TN799 c irc uit p ac k c arries sig naling over p oint-to-p oint p rotoc ol (PPP) for subseq uent inc lusion (via the switc hing fab ric ) in the same DS1 b it stream as the DCS voic e transmissions. A TN780 Tone-Cloc k c irc uit p ac k (installed in the PPN) c an interfac e external Stratum 3 sync hronization for DS1 c onnec tions. For further information about DCS, refer to the following d oc uments: nAT&T System 75/85 Network and Data Servic es Reference Manual nSystem 75 Ap p lic ation Notes Network Servic es nDEFINITY ECS Release 8 Ad ministration for Network Connec tivity Add Circuit Packs A TN 4 6 4 F, TN 7 6 7 E, o r TN 7 6 0 E D S1 c irc u i t p a c k i s re q u ire d f o r PPP c onnec tions. A TN799 Control-LAN c irc uit p ac k is also req uired. 1. Determine the p ort assig nments of the c irc uit p ac ks to b e ad d ed . If there are no availab le p ort slots in the p roc essor c ab inet for the Control-LAN c irc uit p ac k, p lac e it in a R8 EPN c ab inet p ort slot. You d o not need to p ower d own the c ab inet to install the c irc uit p ac k.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-43 Add DCS Interface 6 Install Cables 1. Install c ab le from the c ab inet to a hub or 110 (p urp le) wall field as req uired. Connec t the 259A c onnec tor to the p ort slot c ontaining the Control-LAN circuit pac k. See Figure 6-19 . For a p inout of TN799, see Table 6-3 . Figure 6-19. Cable Connection for Control-LAN Figure Notes 1. 259A Connec tor 2. DW8A Cable3. Hub or 110 (Purp le) Wall Field 1 2 3cydflan2 EWS 101398
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-44 Add DCS Interface 6 Enter Added Translations 1. Get the DOSS order numb er of the upg rad e. Call the reg ional CSA to p erform the step s in this sec tion. 2. To enab le DCS, set the DCS field on the System Parameters-Customer Options sc reen to y . 3. Ad minister the other req uired translation data using the forms listed und er Distrib uted Communic ations System (DCS) in DEFINITY Communic ations System Administration for Network Connec tivity . Save Translations 1. If the system is hig h- or c ritic al-reliab ility, typ e status spe and press En te r to verify that the stand b y SPE is refreshed and that the stand b y d isk is in servic e. 2. Enter save translation [spe-a or both] disk and p ress En t e r. This c ommand instruc ts the system to take all translation information in memory and write it to the d isk(s). Table 6-3. TN799 Pinout Backplane Pin 25-Pair Wire Color Lead NamePeripheral Connector Pin 103 White/Orang e TD+ 27 003 Orange/White TD- 2 104 White/Green RD+ 28 004 Green/White RD- 3
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-45 Add IP Interface Assembly 6 Add IP Interface Assembly DEFINITY ECS IP Solutions allows you to send voic e and fax from the DEFINITY ECS throug h an Internet p rotoc ol (IP) network to other DEFINITY ECSs having this feature or to other H.323 V2 c omp liant end p oints. It is imp lemented using the TN802/B IP Interfac e, whic h is a Wind ows NT server resid ing on the IP Interfac e Assemb ly insid e the DEFINITY ECS. The IP Interfac e is an assemb ly c omp osed of a TN802B c irc uit b oard, a p roc essor c ard , and DSP resourc e c ard . For ord ering p urp oses, the assemb ly is id entified as a J58890MA-1 L30, b ut for simp lic ity, we refer to it in this b ook as the TN802B IP Interfac e. The TN802B IP Interfac e op erates in two mod es: IP Trunk, availab le with Release 7 or later, and Med ia Proc essor (Med Pro), availab le with Release 8. The IP Trunk mod e is Internet Telep hone Server—Enterp rise (ITS-E) c omp atib le, and the Med Pro mod e is H.323 V2 c omp atib le. The TN802B IP Interfac e is b ac kward s c omp atib le and d efaults to IP Trunk mod e.You must ad minister it to use it in Med Pro mod e. For more information on the IP Interfac e c ap ab ilities and limitations, refer to the DEFINITY Enterp rise Communic ations Server Release 8 Overview. The following sec tions d esc rib e the proc ess for nInstalling in Media Processor Mode nInstalling in IP Trunk Mode nUpgrading a TN802 V3 (or later) to a TN802B (MedPro mode) !WARNING: When c onnec ted remotely via p c ANYWHERE, only use the p c ANYWHERE Restart Host Computer b utton on the toolb ar to restart Wind ows NT. Installing in Media Processor Mode To operate in Med Pro mod e, you must install the TN802B IP Interfac e and , if the system d oes not have one, you must also install and administer a TN799B C-LAN c irc uit p ac k. For C-LAN administration, refer to DEFINITY Enterprise Communic ations Server Ad ministration for Network Connec tivity. If you have existing TN802 IP Interfac e c irc uit p ac ks, you c an up g rad e them either b y rep lac ing the c irc uit p ac k with a TN802B or b y d ownload ing the TN802B firmware onto the c irc uit p ac ks (see ‘‘Upgrade to TN802B (R8)’’ on page 6-76).
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-46 Add IP Interface Assembly 6 Prepare for Installation Have the following eq uip ment on site b efore your ship ment arrives: nAC p ower outlets for the mod em and monitor. nThree unoc c up ied and ad joining p ort slots in the DEFINITY ECS for the TN802B IP Interfac e, if need ed. The TN802B oc c up ies only one slot, b ut it need s the two slots to its left for c learanc e. nAn ad d itional unoc c up ied p ort slot for the TN799B, if need ed . If you have an existing TN799 c irc uit p ac k, rep lac e it with the TN799B. nA 10 BaseT or 10/100 BaseT Ethernet c onnec tion into your loc al area network for the TN802B. nA 10 BaseT Ethernet c onnec tion into your loc al area network for the TN799B. nTwo or more valid , unused IP ad d resses on your network (one for MedPro and one for C-LAN) that c an b e assig ned to the IP Interfac e server. You also need the subnet mask and d efault g ateway. nAn analog telep hone line reserved (DID is okay) for the IP Interfac e diagnostic modem nA valid telep hone numb er reserved for the IP Interfac e d iag nostic mod em In ad dition if non-U.S. c ustomer: nMod em c omp arab le to a U.S. Rob otic s Sportster Mod el USR 33.6 EXT. nCable from modem to TN802B external c able assembly. We rec ommend that you p rotec t your c ab inet with an uninterrup tib le power system (UPS). Check your Shipment When your DEFINITY ECS ord er arrives at your site, c hec k the c ontents (see Table 6-4 ). 1. Insp ec t the ship p ing c arton for d amag e b efore op ening it. If the b ox is damaged, do not open it. Inform the ship p ing c omp any, and ask for instruc tions on filing a c laim. 2. If the b ox is und amag ed , c hec k the c ontents ag ainst the p ac king slip . Chec k the c ondition of eac h c omp onent, and note any d amag e or shortag es on the p ac king slip . The c arton should c ontain the following for eac h IP Interfac e ord ered :
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-47 Add IP Interface Assembly 6 3. Read and follow any d irec tions inserted into the p ac kag e b y the fac tory. The TN802B external c ab le assemb ly is a bund le of c ab les with an amp henol c onnec tor at the end of the b und le and various PC-typ e c onnec tors (VGA, Universal Serial Bus [ USB] , mouse, keyb oard , Ethernet, mod em, and COM2) at the end s of the ind ivid ual c ab les. See Fig ure 6-20 . Look for the lab el where the b und le enters the amp henol c onnec tor. Table 6-4. Required Hardware Comcode/Code Description Quantity 108525528 TN799B C-LAN c irc uit p ac k. One TN799B sup p orts more than one TN802B.1 J58890MA-1 L30 TN802B IP Interfac e Assemb ly 1 or more 601939804 H600-512,G1 external c ab le assemb ly 1 or more 259A c onnec tor 1 CAT5 or b etter c able 1 407633999 U.S. Robotic s Sp ortster external modem, Model USR 33.6 EXT (U.S. customers only). Non-U.S. customers must p rovid e a mod em c omp arab le to this mod el.1 601087091 20-ft DB-25 serial c ab le from mod em to TN802B external c ab le assembly (U.S. c ustomers only). Non-U.S. c ustomers must p rovid e a serial c ab le.1
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-48 Add IP Interface Assembly 6 Figure 6-20. TN802B IP Interface External Cable Assembly Connect the Cables 1. Determine into whic h p ort slots you are p utting the TN799B C-LAN and TN802B IP Interfac e c irc uit p ac ks. NOTE: Make sure that at least 3 ad jac ent slots are free for the TN802B. From the rear of the c ab inet: 2. If add ing a new TN799B, c onnec t the 259A c onnec tor to the b ac kp lane c onnec tor c orrespond ing to the TN799B slot. 3. If add ing a new TN799B, c onnec t one end of the DW8 c able to the 259A c onnec tor. Connec t the other end to the c ustomer’s network. 4. Connec t the amp henol c onnec tor on the external c ab le assemb ly to the b ac kp lane c onnec tor c orresp ond ing to the TN802B slot (the hig hest numb ered c onnec tor of the 3 slots req uired ) Figure Notes 1. Amp henol c onnec tor to c onnec tor c orresp ond ing to TN802B slot 2. To VGA monitor 3. To USB (not used ) 4. To keyb oard5. To mouse 6. To ethernet 7. 25-p in male c onnec tor to mod em 8. 25-p in male c onnec tor to COM2 cbdfocto AWF 122398 2 1 345678