    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-39 Remove an EPN Cabinet from an Existing System 
    6
    All Installations
    1. When the system reset is finished, type status port-network 2
     and press 
    En t e r. The Port Network Status sc reen ap p ears. Verify that PNC Ac tive is 
    “ up ”  and that the Servic e State is “ in.”  
    2. A Span LED, on the front of the DS1 Converter circuit pack, must be off for 
    eac h inac tive fac ility administered . For examp le, if Fac ility A and  Fac ility B 
    are unad ministered , then the top  2 Sp an LEDs on the c irc uit p ac k must b e 
    off. If the yellow LEDs are on, then p rob lems were enc ountered d uring the 
    unad ministration of hard ware. Sp an LEDs assoc iated  with ad ministered  
    fac ilities (C and  D, in this examp le) should  b e on.
    Removing the Hardware
    1. Be sure that you have unad ministered  the trunks, attend ant c onsoles, 
    voic e terminals, and  d ata mod ules assoc iated  with the p ort c irc uit pac ks 
    in the EPN c ab inet. 
    2. Remove the fib er op tic  c ab les from the fib er transc eivers at b oth end s of 
    the fib er sp an. Carefully c oil the fib er op tic  c ables. Avoid  b end ing  c ab les 
    to a rad ius smaller than 1.5 inc hes (3.8 c m).
    3. Remove the fib er transc eivers from the DS1 and /or DS1 c onverter c irc uit 
    p ac ks at b oth end s of eac h fib er sp an.
    4. Remove the 25-p air c ab les from the c onnec tor p anel on eac h c arrier of 
    the EPN. 
    5. Type remove cabinet 
      and  p ress 
    En t e r. This removes the EPN 
    c ab inet ad ministration.
    6. Remove the p ower c ord s from the p ower units in eac h c arrier in the EPN 
    and  remove the AC power c ord  or DC p ower wires.
    7. Chec k the ground ing  sc heme for the c ab inets. Perform the following :
    a. If any c ab inet ground  wires c onnec t in 
    series b etween the EPN 
    c ab inet and  any other c ab inet, remove the wires from the EPN 
    c ab inet and  c onnec t them to the next c abinet in the g round  p lane. 
    !CAUTION:
    Never leave c ab inets ungrounded . When a ground  wire is 
    removed  from a series-c onnec ted  c abinet, the g round  p lane 
    b ec omes op en with respec t to all sub seq uent c ab inets.
    b . If any c abinet g round  wires c onnec t in parallel to other c ab inets, or 
    c onnec t d irec tly to the AC p ower panel g round  or other ap proved  
    g round , remove the wire from eac h end  of the g round sp an.
    8. Carefully remove the EPN c ab inet. The c ab inet may weig h as muc h as 
    800 p ound s. Use c aution. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-40 Remove an EPN Cabinet from an Existing System 
    6
    9. Type change system-parameters features
     and  p ress En t e r. Use this 
    sc reen to c hang e the TTI field b ac k to its p revious value b efore the 
    up g rad e.
    10. When finished , p lac e d ust c overs over all exp osed  fib er c oup ling s that 
    remain after the fib er op tic  c ab les are removed .
    11. If any fib er op tic  c ab les were removed  from Lightg uide Interc onnec t Units 
    (LIUs) or Fib er Patc h Panels, remove the assoc iated  c able lab eling . This 
    will prevent c onfusion if existing  fib er is later moved.
    12. Return all unused equipment (not owned by the customer) to Lucent 
    Tec hnolog ies ac c ord ing  to the req uirements outlined in:
    BCS/Material Log istic s, MSL/Attend ed  Stoc king  Loc ations
    Method s and Proc ed ures for Basic  Material Returns
    Troubleshooting 
    Message Waiting Lamps On
    This usually means that all affec ted  p ort-related  translations were not 
    unad ministered .
    1. Type clear amw all 
      and  press 
    En te r. This c lears the messag e 
    waiting  lamp  for the sp ec ified  extension.
    2. Rep eat the c ommand  for eac h extension with a lit messag e waiting  lamp. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-41 Add External Modem to EPN 
    6
    Add External Modem to EPN
    U.S. Robotics Model USR 33.6 EXT External 
    Modem
    Figure 6-18. Connect External Modem to EPN
    1. Connec t an RS-232 c ab le to the modem. See Figure 6-18
    .
    NOTE:
    In the following  step s, a PC with Wind ows 95 or Wind ows NT 4.0 may 
    b e sub stituted for the d umb  terminal. Use the Hyp erterminal 
    (terminal emulation) ap p lic ation. 
    2. Connec t the op p osite end  of the RS-232 c ab le to a d umb  terminal. 
    3. Set the d umb  terminal to full d up lex mod e.
    4. Type AT&N6
     to set the baud  rate to 9600. 
    NOTE:
    The mod em c onnec ts at 9600 b aud  b ut throug hp ut is at 1200 b aud .
    5. Type AT & W 0
     to save the setting  into non-volatile RAM.
    6. Set Switc h 5 to the OFF (up ) p osition to disab le auto answer.
    7. Disc onnec t the RS-232 c ab le from the terminal and c onnec t it to the 
    TERMINAL c onnec tor on the rear of the system c ab inet. Figure Notes:
    1. U.S. Rob otic s External Mod em
    2. RS-232 Cab le
    3. Exp ansion Port Network
    cydfepnm KLC 100397
    TERM INAL
    1
    2
    3 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-42 Add DCS Interface 
    6
    Add DCS Interface
    Systems in a Distrib uted  Communic ations System (DCS) network are 
    interc onnec ted b y b oth tie trunks (for voic e c ommunic ations) and  d ata links (for 
    c ontrol and  transp arent feature information). These d ata links, also c alled  DCS 
    sig naling  links, supp ort the feature transp arenc y. 
    Various sub sets (dep end ing  on the sp ec ific  c onfig uration) of DS1 Interfac e 
    c irc uit p ac ks (inc lud ing TN464F, TN767E, and  TN760E) p rovide the 
    voic e-c ommunic ations interfac e.
    Meanwhile, the d ata link interfac e (b etween the p roc essor and  the p hysic al 
    sig naling  link) is p rovid ed  b y (or throug h) a TN799 Control-LAN c irc uit p ac k. In 
    some c onfig urations, the TN799 passes the sig naling  information over a sep arate 
    10BaseT TCP/IP network (usually via a hub ). For use with 10BaseT, c onnec t the 
    ap p rop riate p ins of the I/O field  to the hub . For p inouts and  d iagrams, refer to the 
    installation manual for your c ab inet typ e. In other c onfigurations, the TN799 
    c irc uit p ac k c arries sig naling  over p oint-to-p oint p rotoc ol (PPP) for subseq uent 
    inc lusion (via the switc hing  fab ric ) in the same DS1 b it stream as the DCS voic e 
    transmissions.
    A TN780 Tone-Cloc k c irc uit p ac k (installed  in the PPN) c an interfac e external 
    Stratum 3 sync hronization for DS1 c onnec tions.
    For further information about DCS, refer to the following  d oc uments:
    nAT&T System 75/85 Network and Data Servic es Reference Manual
    nSystem 75 Ap p lic ation Notes Network Servic es
    nDEFINITY ECS Release 8 Ad ministration for Network Connec tivity
    Add Circuit Packs
    A TN 4 6 4 F,  TN 7 6 7 E,  o r  TN 7 6 0 E D S1  c irc u i t  p a c k  i s re q u ire d  f o r  PPP c onnec tions. 
    A TN799 Control-LAN c irc uit p ac k is also req uired.
    1. Determine the p ort assig nments of the c irc uit p ac ks to b e ad d ed . If there 
    are no availab le p ort slots in the p roc essor c ab inet for the Control-LAN 
    c irc uit p ac k, p lac e it in a R8 EPN c ab inet p ort slot. You d o not need  to 
    p ower d own the c ab inet to install the c irc uit p ac k.  
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-43 Add DCS Interface 
    6
    Install Cables
    1. Install c ab le from the c ab inet to a hub  or 110 (p urp le) wall field  as 
    req uired. Connec t the 259A c onnec tor to the p ort slot c ontaining the 
    Control-LAN circuit pac k. See Figure 6-19
    . For a p inout of TN799, see 
    Table 6-3
    . 
    Figure 6-19. Cable Connection for Control-LAN Figure Notes
    1. 259A Connec tor
    2. DW8A Cable3. Hub  or 110 (Purp le) Wall Field
    1
    2
    3cydflan2  EWS 101398 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-44 Add DCS Interface 
    6
    Enter Added Translations
    1. Get the DOSS order numb er of the upg rad e. Call the reg ional CSA to 
    p erform the step s in this sec tion.
    2. To enab le DCS, set the DCS
     field  on the System Parameters-Customer 
    Options sc reen to y
    .
    3. Ad minister the other req uired  translation data using  the forms listed  und er 
    Distrib uted  Communic ations System (DCS) in 
    DEFINITY Communic ations 
    System Administration for Network Connec tivity
    .
    Save Translations
    1. If the system is hig h- or c ritic al-reliab ility, typ e status spe
     and press En te r  
    to verify that the stand b y SPE is refreshed  and  that the stand b y d isk is in 
    servic e.
    2. Enter save translation [spe-a or both] disk
     and  p ress 
    En t e r. This 
    c ommand  instruc ts the system to take all translation information in 
    memory and  write it to the d isk(s).
    Table 6-3. TN799 Pinout
    Backplane Pin 25-Pair Wire Color Lead NamePeripheral 
    Connector Pin
    103 White/Orang e TD+ 27
    003 Orange/White TD- 2
    104 White/Green RD+ 28
    004 Green/White RD- 3 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-45 Add IP Interface Assembly 
    6
    Add IP Interface Assembly
    DEFINITY ECS IP Solutions allows you to send  voic e and  fax from the DEFINITY 
    ECS throug h an Internet p rotoc ol (IP) network to other DEFINITY ECSs having  
    this feature or to other H.323 V2 c omp liant end p oints. It is imp lemented  using  the 
    TN802/B IP Interfac e, whic h is a Wind ows NT server resid ing  on the IP Interfac e 
    Assemb ly insid e the DEFINITY ECS.
    The IP Interfac e is an assemb ly c omp osed  of a TN802B c irc uit b oard, a 
    p roc essor c ard , and DSP resourc e c ard . For ord ering  p urp oses, the assemb ly is 
    id entified  as a J58890MA-1 L30, b ut for simp lic ity, we refer to it in this b ook as the 
    TN802B IP Interfac e.
    The TN802B IP Interfac e op erates in two mod es: IP Trunk, availab le with Release 
    7 or later, and  Med ia Proc essor (Med Pro), availab le with Release 8. The IP Trunk 
    mod e is Internet Telep hone Server—Enterp rise (ITS-E) c omp atib le, and  the 
    Med Pro mod e is H.323 V2 c omp atib le. The TN802B IP Interfac e is b ac kward s 
    c omp atib le and  d efaults to IP Trunk mod e.You must ad minister it to use it in 
    Med Pro mod e.
    For more information on the IP Interfac e c ap ab ilities and  limitations, refer to the 
    DEFINITY Enterp rise Communic ations Server Release 8 Overview.
    The following sec tions d esc rib e the proc ess for
    nInstalling in Media Processor Mode
    nInstalling in IP Trunk Mode
    nUpgrading a TN802 V3 (or later) to a TN802B (MedPro mode)
    !WARNING:
    When c onnec ted  remotely via p c ANYWHERE, only use the p c ANYWHERE 
    Restart Host Computer b utton on the toolb ar to restart Wind ows NT.
    Installing in Media Processor Mode
    To operate in Med Pro mod e, you must install the TN802B IP Interfac e and , if the 
    system d oes not have one, you must also install and  administer a TN799B
     C-LAN 
    c irc uit p ac k. For C-LAN administration, refer to 
    DEFINITY Enterprise 
    Communic ations Server Ad ministration for Network Connec tivity.
    If you have existing  TN802 IP Interfac e c irc uit p ac ks, you c an up g rad e them 
    either b y rep lac ing  the c irc uit p ac k with a TN802B or b y d ownload ing  the 
    TN802B firmware onto the c irc uit p ac ks (see ‘‘Upgrade to TN802B (R8)’’ on page 
    6-76).  
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-46 Add IP Interface Assembly 
    6
    Prepare for Installation
    Have the following  eq uip ment on site b efore your ship ment arrives:
    nAC p ower outlets for the mod em and  monitor.
    nThree unoc c up ied  and  ad joining  p ort slots in the DEFINITY ECS for the 
    TN802B IP Interfac e, if need ed.
    The TN802B oc c up ies only one slot, b ut it need s the two slots to its left for 
    c learanc e.
    nAn ad d itional unoc c up ied  p ort slot for the TN799B, if need ed . If you have 
    an existing TN799 c irc uit p ac k, rep lac e it with the TN799B.
    nA 10 BaseT or 10/100 BaseT Ethernet c onnec tion into your loc al area 
    network for the TN802B.
    nA 10 BaseT Ethernet c onnec tion into your loc al area network for the 
    TN799B.
    nTwo or more valid , unused  IP ad d resses on your network (one for MedPro 
    and  one for C-LAN) that c an b e assig ned  to the IP Interfac e server. You 
    also need  the subnet mask and  d efault g ateway. 
    nAn analog telep hone line reserved  (DID is okay) for the IP Interfac e 
    diagnostic modem 
    nA valid  telep hone numb er reserved  for the IP Interfac e d iag nostic  mod em 
    In ad dition if non-U.S. c ustomer:
    nMod em c omp arab le to a U.S. Rob otic s Sportster Mod el USR 33.6 EXT.
    nCable from modem to TN802B external c able assembly.
    We rec ommend  that you p rotec t your c ab inet with an uninterrup tib le power 
    system (UPS).
    Check your Shipment
    When your DEFINITY ECS ord er arrives at your site, c hec k the c ontents (see 
    Table 6-4
    ).
    1. Insp ec t the ship p ing  c arton for d amag e b efore op ening  it. If the b ox is 
    damaged, 
    do not open it. Inform the ship p ing  c omp any, and  ask for 
    instruc tions on filing a c laim.
    2. If the b ox is und amag ed , c hec k the c ontents ag ainst the p ac king  slip . 
    Chec k the c ondition of eac h c omp onent, and note any d amag e or 
    shortag es on the p ac king  slip . The c arton should  c ontain the following  for 
    eac h IP Interfac e ord ered : 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-47 Add IP Interface Assembly 
    6
    3. Read  and  follow any d irec tions inserted  into the p ac kag e b y the fac tory.
    The TN802B external c ab le assemb ly is a bund le of c ab les with an amp henol 
    c onnec tor at the end  of the b und le and  various PC-typ e c onnec tors (VGA, 
    Universal Serial Bus [ USB] , mouse, keyb oard , Ethernet, mod em, and  COM2) at 
    the end s of the ind ivid ual c ab les. See Fig ure 6-20
    . Look for the lab el where the 
    b und le enters the amp henol c onnec tor. 
    Table 6-4. Required Hardware
    Comcode/Code Description Quantity
    108525528 TN799B C-LAN c irc uit p ac k. One 
    TN799B sup p orts more than one 
    TN802B.1
    J58890MA-1 L30 TN802B IP Interfac e Assemb ly
    1 or more
    601939804 H600-512,G1 external c ab le assemb ly 1 or more
    259A c onnec tor 1
    CAT5 or b etter c able 1
    407633999 U.S. Robotic s Sp ortster external 
    modem, Model USR 33.6 EXT (U.S. 
    customers only). Non-U.S. customers 
    must p rovid e a mod em c omp arab le to 
    this mod el.1
    601087091 20-ft DB-25 serial c ab le from mod em 
    to TN802B external c ab le assembly 
    (U.S. c ustomers only). Non-U.S. 
    c ustomers must p rovid e a serial c ab le.1 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-48 Add IP Interface Assembly 
    6
    Figure 6-20. TN802B IP Interface External Cable Assembly
    Connect the Cables
    1. Determine into whic h p ort slots you are p utting the TN799B C-LAN and  
    TN802B IP Interfac e c irc uit p ac ks.
    NOTE:
    Make sure that at least 3 ad jac ent slots are free for the TN802B.
    From the rear of the c ab inet:
    2. If add ing  a new TN799B, c onnec t the 259A c onnec tor to the b ac kp lane 
    c onnec tor c orrespond ing  to the TN799B slot.
    3. If add ing  a new TN799B, c onnec t one end  of the DW8 c able to the 259A 
    c onnec tor. Connec t the other end  to the c ustomer’s network.
    4. Connec t the amp henol c onnec tor on the external c ab le assemb ly to the 
    b ac kp lane c onnec tor c orresp ond ing  to the TN802B slot (the hig hest 
    numb ered c onnec tor of the 3 slots req uired ) Figure Notes
    1. Amp henol c onnec tor to c onnec tor 
    c orresp ond ing  to TN802B slot
    2. To VGA monitor
    3. To USB (not used )
    4. To keyb oard5. To mouse
    6. To ethernet
    7. 25-p in male c onnec tor to mod em
    8. 25-p in male c onnec tor to COM2 
    cbdfocto AWF 122398
    2
    1
    345678 
    						
    All Lucent Technologies manuals Comments (0)