Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Upgrading R5r/R6r/R7r to R8r without Adding Memory 2-1 2 DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 2 Upgrading R5r/R6r/R7r to R8r without Adding Memory This chapter provides the information necessary to upgrade the software from a DEFINITY ECS Release 5r, Release 6r, or Release 7r to a Release 8r system without ad d ing memory. The c hap ter also p rovid es information on rep lac ing the tap e d rive with the op tic al d rive and replac ing the UN332B MSSNET c irc uit p ac k with the UN332C c irc uit p ac k, whic h is req uired for the op tic al drive. The p roc ed ures step throug h a software and hard ware up g rade that c an b e d one on either a stand ard reliab ility or a hig h or c ritic al reliab ility system. There are many c onfig urations of DEFINITY ECS Release 5r/6r/7r in the field , and eac h system c an have a uniq ue c onfig uration. This b ook ad d resses the most c ommon c onfig urations. Also refer to the following b ooks: — DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e — DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8 r NOTE: If the c ab inet is older than Release 5, refer to DEFINITY Communic ations System Generic 3r (G3r) Up g rad es and Ad d itions .
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5r/R6r/R7r to R8r without Adding Memory 2-2 Read This First 2 Read This First Service Interruption The up g rad e p roc ess req uires 2 non–c all-p reserving servic e interrup tions in a stand ard reliability system and must b e c losely c oord inated with the c ustomer and the loc al ac c ount team. Call Management System (CMS) The CMS link is dropped and restarted during the upgrade. This causes CMS d ata to b e lost. This d ata loss c an be minimized if the up g rad e is p erformed just after the last CMS measurement interval. All measurement d ata is lost d uring the up g rad e (inc lud ing BCMS). If need ed , the reports may be printed before the upgrade begins. CMS c ould ab ort the p roc essing of a c all if a measured trunk that was part of the c onferenc e d rop p ed off the c all b efore the end of the c all. Customers exp erienc ing this symp tom and who are running R3V4 CMS should upd ate to r3v4a or hig her. Software Compatibility and Translation Errors Before starting the up g rad e, always c hec k the Software Release Letter that ac c omp anies the system removable med ia. Translation c orrup tion will oc c ur if inc ompatib le software is load ed . After load ing the new software, c hec k for translation errors. To d o this, log in and c hec k for a “ Translation Corrup tion Detec ted ” messag e b efore c ontinuing with the up g rad e p roc ess. If errors are d etec ted , refer to ‘‘No Translations After Upgrade’’ in Appendix B, ‘‘Troubleshooting an Upgrade’’. Do not c ontinue with the up g rad e until the errors are corrected. Usable Circuit Packs Every circuit pac k used in the Release 8 system must conform to the minimum usab le vintag e req uirements for that system. At a p resale site insp ec tion, the remed iation p roc ess c hec ks the vintag es of existing c irc uit p ac ks to b e reused in the Release 8 system. Rep lac e all unusab le vintag e c irc uit pac ks with c urrent vintag es. Refer to Technical Quarterly, Referenc e Guid e for Circ uit Pac k Vintag es, Chang e Notic es, and to the Software Release Letter for information ab out usab le c irc uit p ac k vintag es. For information about usab le vintag es of non-U.S. c irc uit p ac ks, refer to the ITAC Tec h Alert from your reg ional d istrib utor.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5r/R6r/R7r to R8r without Adding Memory 2-3 Read This First 2 Software Upgrade Release 8 software and translations are saved to removable media. Although the translations automatic ally up d ate to Release 8, several features req uire sp ec ial attention b ec ause of sc reen c hang es or p otential naming c onflic ts in the p roc ess. Between c ustomer c onfirmation and the ac tual up d ate or up g rad e, c hec k the sc reens to ensure the translations meet the c ustomer’s need s. After reb ooting the system, enter these translations either loc ally or remotely. If done remotely, Contac t Field Sup p ort Ad ministration Center (FSAC) for the remote entry. For information to make the req uired c hang es, refer to: nDEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e Required Tools This up g rad e may req uire the following tools and other items: nWrist ground strap nStatic -p roof or orig inal c irc uit p ac k p ac kag ing for transp orting c irc uit packs nOne c op y of eac h of the following b ooks: — DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8r — DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e Antistatic Protection !CAUTION: When hand ling c irc uit pac ks or any c omp onents of a DEFINITY ECS system, always wear an antistatic wrist g round strap . Connec t the strap to an ap p roved g round suc h as g round jac k on the DEFINITY ECS system.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5r/R6r/R7r to R8r without Adding Memory 2-4 Read This First 2 Required Hardware The equipment in Table 2-1 must be on-site b efore the up g rad e beg ins. To p lac e a c laim for missing eq uip ment, as p art of the Streamlined Imp lementation p roc ess, c all 1-800-772-5409 or the numb er p rovid ed b y your Luc ent Tec hnolog ies rep resentative. Table 2-1. Required Hardware Quantity Equipment Description Standard High/Critical 108566381 UN332C MSSNET c irc uit p ac k 12 107849754 TN2211 optic al d rive 1 2 106590953 Z100A1 app aratus b lank 1 2 J58890TO-1 L1 or J5889OTF-1 L1Formatted removable med ia with Release 8 software24 848445086 848445094Carrier A strip label Carrier B strip label1 NANA 1
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5r/R6r/R7r to R8r without Adding Memory 2-5 Task Tables 2 Ta s k Ta b l e s Table 2-2 lists the hig h-level tasks to perform the up g rad es. Refer to the ap p rop riate p ag e for instruc tions for eac h step . The up g rad e p roc ed ure is similar for b oth the stand ard and hig h or c ritic al reliability system with a few exc ep tions. These exc ep tions are noted as you g o throug h the step s. Table 2-2. Upgrade tasks ÖTask Description Page Check SPE 2-7 Save Translations2-7 Save Announcements (if necessary)2-7 Back Up Disk2-7 Disable Scheduled Maintenance and Alarm Origination to INADS2-8 Check Link Status2-8 Disable TTI2-9 Check TTI Status2-9 Busyout MMI Circuit Packs (H/C only)2-9 Lock the active SPE (H/C only)2-10 Check the Active Tone-Clock (H/C only)2-10 Power Down the Processor Carrier2-10 Remove the Circuit Packs2-11 Install the Circuit Packs2-11 Power Up the Processor Carrier2-13 Unlock the Active SPE (H/C only)2-13 Verify Interchange (H/C only)2-14 Upgrade Other Carrier (H/C only)2-14 Affix position label(s)2-14 Verify software version2-14 Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5r/R6r/R7r to R8r without Adding Memory 2-6 Task Tables 2 Save Translations2-15 Save Announc ements (if nec essary)2-15 Restore Disk2-15 Up g rad e Software2-15 Re s e t SPE s t a t u s ( H / C o n l y )2-16 Se t D a y li g h t Sa v i n g s Ru l e s2-16 Set Date and Time2-17 Set Core Dump Vec tor2-19 Enable TTI2-19 Release MMI (H/C only)2-19 Resolve Alarms2-19 Chec k Link Status2-19 Enable Sc hed uled Maintenanc e2-19 Enable Customer Options and Alarm Origination to INADS2-20 C h e c k SPE st a t u s ( H / C o n l y)2-20 Save Translations2-20 Save Announc ements (if nec essary)2-21 Bac k Up Disk2-21 Return Rep lac ed Eq uip ment2-21 Table 2-2. Upgrade tasks — Continued ÖTask Description Page Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5r/R6r/R7r to R8r without Adding Memory 2-7 Upgrade the software and hardware 2 Upgrade the software and hardware Check SPE 1. Type status spe and press En t e r to c hec k the health of the SPE. For hig h or c ritic al reliab ility systems: nTh e Standby Refreshed field shows yes nTh e Standby Shadowing field shows on nTh e Standby Handshake field shows up Save Translations 1. Type save translation and press En te r to write all translation information from memory to the d isk, whic h takes ab out 2 minutes. Save Announcements (if necessary) NOTE: The TN750C Announc ement c irc uit p ac k stores announc ements in nonvolatile memory; saving the announc ements is op tional. 1. If the PPN c ontains a TN750B Announc ement c irc uit p ac k, type display announcements and p ress En te r. 2. If administered rec ord ed announc ements are listed , typ e save announcements cabinet carrier slot and press En t e r. For example, 01 D03. This takes ab out 30 minutes. NOTE: For some software load s, type save announcements from cabinet carrier slot . Typ e help and p ress En t e r for c omp lete c ommand usag e. Back Up Disk 1. Type backup disk and p ress En t e r to write all information from the d isk to the b ac kup tap e. This takes 30 to 40 minutes. 2. Remove the tap e(s) from the tap e d rive(s).
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5r/R6r/R7r to R8r without Adding Memory 2-8 Upgrade the software and hardware 2 Disable Scheduled Maintenance and Alarm Origination to INADS NOTE: Make sure sc hed uled d aily maintenanc e d oes not interfere with the up g rad e. 1. Type change system-parameters maintenance and press En t e r . 2. If sc heduled maintenanc e has b eg un, set the Stop Time field to 1 minute after the c urrent time. or If sc hed uled maintenanc e has not b eg un, set the Start Time field to a time after the upgrade is completed. For example, if you start the upgrade at 8:00 p .m. and the up g rad e takes 90 minutes, set the Start Time field to 21:30. !CAUTION: If you d o not d isab le Alarm Orig ination, the system may g enerate alarms, resulting in unnec essary troub le tic kets. 3. Type n in the Alarm Origination field and p ress En t e r if the field is not set to neither . NOTE: Fo r s o m e s o f t w a re l o a d s, set the Cleared Alarm Notification and Restart Notification fields to n b efore pressing En te r. Check Link Status 1. Type display communication-interface links and p ress En te r. Write d own all enab led links. 2. Type status link number and p ress En t e r. Rep eat this step for all links. 3. Write d own whic h links are in servic e.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5r/R6r/R7r to R8r without Adding Memory 2-9 Upgrade the software and hardware 2 Disable TTI NOTE: Do this step only if the Terminal Translation Initialization (TTI) is enab led . !CAUTION: If you d o not d isab le the TTI, the translations c an b e c orrup ted . 1. Type change system-parameters features and press En t e r. 2. On the sec ond sc reen, set the TTI Enabled? field to n to d e-ac tivate the TTI feature. Check TTI Status 1. Type status tti and press En te r. Wait until the Percent Complete field shows 100% . Busyout MMI Circuit Packs (H/C only) !CAUTION: Multimed ia-to-voic e station c alls are not p reserved on an up g rad e. Failure to b usy-out the TN787 Multimedia Interfac e (MMI) c irc uit p ac ks results in unusab le TN787 and TN788 Multimed ia Voic e Cond itioner p orts. 1. Type display system-parameters customer-options and press En t e r. On sc reen 2 und er the Multimed ia Call Hand ling (MMCH) op tions, c hec k the Basic and Enhanced fields. 2. If either the Basic or Enhanced field is y , typ e list configuration all and p ress En t e r to loc ate all MMI (TN787) c irc uit p ac ks. 3. If there are MMI c irc uit p ac ks, typ e busyout board cabinet carrier slot and p ress En t e r to remove the c irc uit p ac ks from servic e.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Upgrading R5r/R6r/R7r to R8r without Adding Memory 2-10 Upgrade the software and hardware 2 Lock the active SPE (H/C only) 1. Typ e status sp e and p ress En t e r to d etermine whic h c ontrol c arrier is ac tive or ob serve the c ontrol c arrier LEDs. NOTE: For hig h or c ritic al reliab ility systems, we rec ommend that you rep lac e the c irc uit pac ks in the stand b y c arrier first. !CAUTION: When rep lac ing any hardware, b e sure to g round yourself against elec trostatic d isc harg e (ESD) b y wearing a g round ed wrist strap . 2. Move the SPE-SELECT switc hes on b oth Dup lic ation Interfac e (DUPINT) circuit packs, one at a time, to the ac tive c arrier. Check the Active Tone-Clock (H/C only) 1. Type status port-network 1 and verify that the Tone-Cloc k is in the same c a r r ie r a s t h e a c t i v e SPE a n d t h a t t h e Service State field shows in . NOTE: This takes 1 minute to c omp lete. If the servic e state is inc orrec t, rep eat the c ommand until this c ond ition is met. If the ac tive Tone-Cloc k has not migrated to the ac tive c arrier after 1 minute, then a Tone-Cloc k p rob lem exists. Refer to the TDM-CLK Maintenanc e Ob jec ts sec tion of the DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8r b ook to resolve any p rob lems. Power Down the Processor Carrier !CAUTION: Do not p ower d own the whole c ab inet; it is not nec essary. For stand ard reliab ility, p ower d own the p roc essor c arrier. This c auses a servic e interrup tion. For high or critical reliability, power down the standby carrier. 1. To power down the processor carrier, remove the power plug from the left sid e of the c arrier, then remove the p ower p lug from the rig ht sid e of the carrier.