Vodavi Starplus Triad S Description Manual
Have a look at the manual Vodavi Starplus Triad S Description Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Print System Database Parameters Introduction12-3 PRINTING SYS PARAMadm>SYSTEM PARAMETERS______-_---------Eng. Ver. 1.31-1EFBSYS HOLD RECALL 60EXC HOLD RECALL 180ATND RECALL TIMER1TRANSFER RECALL 45PRESET FWD TIMER 10CALL FWD NO ANS15PAUSE TIMER 2CALL PARK TIMER 180CONFERENCE TIMER10PAGING TIMEOUT 15CO RING DETECT 3SLT RCVR TIMER20M/W TONE TIMER0HOOK SWITCH TIME 10HOOK SWT BOUNCE10SMDR CALL QUAL 30AUTO CALL BACK3REMINDER RING 0RELEASE GUARD3INTERDIGIT T/O 5RPT REDIAL60ATTENDANT DISPLAY 1CALL COVERAGE RING 5 MODEM ANSWER T/O 25INT DIGIT PULSE 300DTMF ON/OFF TIME1SYSTEM FEATURES --------------- ATTENDANT OVERRIDEDISABLED HOLD PREFERENCESYSTEM EXTERNAL NIGHT RING DISABLED EXECUTIVE WARNINGENABLED PAGE WARNING TONEENABLED BACKGROUND MUSICENABLED LEAST COST ROUTINGDISABLED FORCED ACCOUNT CODEDISABLED GROUP LISTENINGDISABLED IDLE SPEAKER MODEDISABLED CALL COST DISPLAYDISABLED MUSIC ON HOLDENABLED CALL QUALIFIER TONEDISABLEDBARGE IN WARN TONEENABLED. CO RING TONES ENABLED VERIFIED ACCT CODES DISABLED CALL FWD DISPLAY ENABLED EXTERNAL DAY RINGDISABLED OVERFLOW STA FWDDISABLED DIRECT XFERENABLED STATION LOCKDISABLED LCR CALL PROGRESSENABLED RECORDING WARN TONE ENABLED MAINTENANCEDISABLED RINGBACK ON XFER DISABLED SYSTEM LED FLASH RATES ---------__----_____--INC CO RINGRED 480 IPM FLUTTER INC ICM RING RED 120 IPM FLUTTER CALL FORWARD BTN RED STEADY ON MSG WAIT VM BTN RED STEADY ON MSG CBCK DSS/BLFRED 120 IPM FLUTTER DND DSS/BLFRED 60 IPM DBL WINK OFF AUTO CBCK DSS/BLF RED 120 IPM FLASH UCD UNAVL DSS/BLF RED 60 IPM DBL WINK OFF TRANSFER CO RING RED 120 IPM FLASH RECALL CO RING RED 480 IPM FLUTTER EXCLUSIVE HOLD GREEN 120 IPM FLASH QUEUED CO RING GREEN 480 IPM FLUTTER SYSTEM HOLDRED 60 IPM DBL WINK OFF IN USE HOLD GREEN 60 IPM FLASH CAMP ON BTNRED 120 IPM FLASH CALL BACK BTNRED 120 IPM FLASH LINE QUEUE BTN RED 480 IPM FLUTTER DND BTNRED STEADY ON ICM HOLD BTN RED15 IPM FLASH LEADING DIGIT 1 LEADING DIGIT LEADING DIGIT 2NONE LEADING DIGIT 3NONE LEADING DIGIT 4NONE LEADING DIGIT 5 NONE LEADING DIGIT 6NONE LEADING DIGIT 7NONE LEADING DIGIT OPTION DISABLED CENTREX DIGITS4VM ID DIGITS3Figure 12-1: System Parameters STARPLUS Triad-S System Programming Manualissue I- December 1998
12-4Print System Database Parameters IntroductionMUSIC CHANNEL 13. .81 CO - ##it ### ### #tATTENDANT STATIONS 100 ### ###F 4 08001700s 5 #+I######S 6########DIAL PULSE - 60/40 10 PPS DATE & TIME FORMAT MM/DD/YY, 12 HOURS PBX DIALING CODES ## ## ## ## ## EXECUTIVE/SECRETARY PAIRINGS 1=###### 2 =###### 3 = ###### 4 =######ON BOARD RELAY RELAY ASSIGNMENTS NONE NONE I/O BAUD RATE ------------- Port1 = 9600 Port2 = 9600 Port 3 = 9600 Port 4 = 9600 ACCESS CODE 1 DISA ACCESS 1002 ADMIN PASSWORD3226SDR TPE PNT BAUD PORT N LD80 9600 3 AUTO NIGHT MODE NWEEKLY NIGHT MODE SCHEDULE END STARTDAYTIMETIME M 008001700T108001700 w208001700T308001700CABINET SLOT TYPE 00LCOB01DTIB 02LCOB03DTIB 04LCOB05DTIB 06LCOB 07DTIB POWER SUPPLY TYPES 10 AMPS LO AMPS 10 AMPS 10 AMPS ALARM DESCRIPTION CARRIER LOSS BLUE ALARM YELLOW ALARM RED ALARM BIPOLAR VARIATIONS SLIP ALARM DATA ERRORS COLINE GROUP QUEUING GROUP 0ENABLED GROUP 1ENABLED GROUP2ENABLED GROUP 3ENABLED GROUP4ENABLED GROUP 5ENABLED GROUP6ENABLED GROUP I ENABLEDALARMPERIOD THRESHOLtMINOR MAJOR 1530 1530 1530 1530 1530 1530 1530 krgure12-I:System Parameters (Continued) Issue I- December 1998 STARPLUS Triad-S System Programming Manual
.~. Print System Database Parameters12-5 IntroductionPrint CO Line Attributes ~~~ Programming Steps G=..I.:, :’ . . ._...IPress the CO LINE ATTRIBUTES flexible button (FLASH 85, button #2). The following message displays on the display phone: PRINT CO LINES PRESS HOLD 2To print the data for ALL CO Lines, press the HOLD button. To print CO Line data for a specified CO Line Range, enter 6 digits to specify the CO Line .Range (3 digits for the first line within the range and 3 digits for the last line in the range): If a only one line is desired, enter that line twice: [OOI 0011 3Then press the HOLD button. The following message displays on the display phone and the CO Line data prints: PRINTING CO LINES When the system finishes sending the requested information to the printer, a confirmation tone is heard. Description This command dumps the entire database as a permanent record which can serve as a hardcopy of the database The system baud rate must match that of the printer or receiving device. When printing the CO Line attributes the following data prints: -z+All CO Line parameters within the specified range. 8tCO Line ringing assignments within the specified range. 4.Dial Pulse Ratio and Speed settings STARPLUS Triad-S System Programming ManualIssue I- December 1998
12-6Print System Database Parameters Introduction Refer to Figure 12-Z: CO Li?ze Attributes for an example of the CO Line Attributes database printout.CO LINE ATTRIBUTES -_.__....--..--..- co 001DIAL PULSE/DTMF DTMF PBX/CO co UNIVERSAL NIGHT ANS ENABLED DISA TRK TO TRK ENABLED PRIVACY ENABLED LOOOP SUPERVISION 4 DISA TYPE NONE LINE GROUP 1 CLASS OF SERVICE - 1 LINE IDENTIFICATION LINE 001 CO DIRECTION - INCOMING-OUTGOING RING ASSIGNMENTS 1OOAT-l SIGNAL TYPE - LOOP START T-l RINGBACK ENABLED T-l DIALTONE - DISABLED TRANSMIT VOLUME ODB PRESET FORWARD DEST - NONE PRESET FWD VMID NONE UNIVERSAL DAY ANSWER - DISABLED MOH CHANNEL 1 RING TONE - 0 FLASH TIMER - 10 RING DELAY TIMER 0 WINK TIMER 140 RELEASE TIMER - 20 RESEIZE TIMER - 200 GUARD TIMER 50 SIEZE TIMER - 10 PRESET FWD TIMER - 100 DID COLLECT TIMER - 150 TI COLLECT TIMER 150co 02 DIAL PULSE/DTMF DTMF PBX/CO CO UNIVERSAL. NIGHT ANS ENABLED DISA TRK TO TRK - ENABLED PRIVACY ENABLED LOOP SUPERVISION - 4 DISA TYPE - NONE LINE GROUP - 1 CLASS OF SERVICE - 1 LINE IDENTIFICATION LINE 002 CO DIRECTION - INCOMING-OUTGOING RING ASSIGNMENTS 1OOAT-l SIGNAL TYPE LOOP START T-l RINGBACK - ENABLED T-l DIALTONE - DISABLED TRANSMIT VOLUME ODB PRESET FORWARD DEST - NONE PRESET FWD VMID - NONE UNIVERSAL DAY ANSWER DISABLED MOH CHANNEL - 1 RING TONE 0 FLASH TIMER - 10 RING DELAY TIMER - 0 WINK TIMER - 140 RELEASE TIMER - 20 RESEIZE TIMER 200 GUARD TIMER 50 SEIZE TIMER 10 PRESET FWD TIMER 100 DID COLLECT TIMER 150 TI COLLECT TIMER - 150 . . .and so on through CO lines 012 Figure 12-2: CO Line Attributes Issue I- December 1998 STARPLUS Triad-S System Programming Manual
Print System Database Parameters Introduction 12-7 Print Station Attributes Programming StepsPress the STATION ATTRIBUTES flexible button (FLASH 85, button #3). The following message displays on the display phone: PRINT STATIONS PRESS HOLDTo print data for all stations, press the HOLD button. To print Station data for a specified Station Range, enter six digits to specify the Station range (three digits for the first station within the range and three digits for the last station in the range): [IOO-1311 = Triad-S If only one station is desired, enter that station twice: [I OIIOI]Then press the HOLD button. The following message displays on the display phone and the requested information prints: PRINTING STATIONS When the system finishes sending the requested information to the printer, a confirmation tone is heard. Description This command dumps the entire database as a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device. When printing the Station attributes the following data prints: 44All current station parameters Refer to Figure Gf-3: Station Attdmtes for an example of the Station Attributes database printout. STARPLUS Triad-S System Programming ManualIssue I- December 7998
12-8Print System Database Parameters IntroductionSTATION ATTRIBUTES ________.__--..... STA 100PAGE ACCESS ENABLED DO NOT DISTURB ENABLED CONFERENCE ENABLED EXEC OVERRIDE DISABLED PRIVACY ENABLED SYSTEM SPEED ENABLED LINE QUEUING ENABLED PREF LINE ANSWER DISABLED OFF HOOK VOICE OVER DISABLED CALL FORWARD ENABLED FORCE LCR DISABLED ACD SUPV BARGE IN DISABLED EXEC OVERRIDE BLOCK DISABLED COC RING OPTIONS MUTED RING NAME AT IDLE LCD EXT NUMBER STATION ID KEYSET DAY COS 1NIGHT COS 1 SPEAKERPHONE FULL SPEAKERPHONE PICKUP GROUPS 1 PAGE ZONE 1PRESET FORWARD ###LINE GROUP ACCESS 1 LCR CLASS OF SERVICE 0 OFFHOOK PREFENCE BTN 00 ENABLED KEYSET MODE INACTIVE MODE VOICEMAIL ID 100 BUTTONS OlDlOO 02DlOl 03D102 04D103 05D104 060105 07D106 08D107 09D108 lOD109 llDll0 12Dlll 13COOl 14coo2 15coo3 16COO4 17COO5 18COO6 19LP 2OPLl PlCBK22PKU 23DND 24LQU 25SPD 26MSG 27XFR 28CNF 29CP0 30FWD 31MUT 32FLA 33MON 37VOLSTA 101PAGE ACCESS ENABLED DO NOT DISTURB ENABLED CONFERENCE ENABLED EXEC OVERRIDE DISABLED PRIVACY ENABLED SYSTEM SPEED ENABLED LINE QUEUING ENABLED PREF LINE ANSWER DISABLED OFF HOOK VOICE OVER DISABLED CALL FORWARD ENABLED FORCE LCR DISABLED ACD SUPV BARGE IN DISABLED EXEC OVERRIDE BLOCK DISABLED CO RING OPTIONS MUTED RING NAME AT IDLE LCD EXT NUMBER STATION ID KEYSET DAY COS 1NIGHT COS 1 SPEAKERPHONE FULL SPEAKERPHONE PICKUP GROUPS 1 PAGE ZONE 1PRESET FORWARD ###LINE GROUP ACCESS 1 LCR CLASS OF SERVICE 0 OFFHOOK PREFENCE BTN 00 ENABLED KEYSET MODE INACTIVE MODE VOICEMAIL ID 101 BUTTONS OlDlOO 02DlOl 03D102 04D103 05COOl 06COO2 07LP 08PLl 09CBK 1OPKU 1lDND 12LQU 13 14 15 16 17 18 19 20 2122 23 24 25SPD .and so on through stations 131 Figure 12-3: Station Attributes Issue I - December 1998STARPLUS Triad-S System Programming Manual
Print System Database Parameters IntroductionThe button printout for the 8-button keyset displays u/l flexible buttons and fixed buttons the same as a 24-button keyset.Print CO / Station Port Parameters Programming Steps IPress the PORT-STA/CO flexible button (FLASH 85, button #4). The following message displays on the display phone: PRINT PORT - STA / COPRESS HOLD t 2To print the CO/Station Port parameters, press the HOLD button. The following message displays on the display phone: PRINTING PORT - STA / CO When the system finishes sending the requested information to the printer, a confirmation tone is heard. Description This command dumps the entire database as a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device.CO PORT NUMBERS ____..-.-----..001 002 003 004 005 006 007 008 009010 011 012 STATION PORT NUMBERS 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 Figure 12-4: CO I Station Port Attributes STARPLUS Triad-S System Programming ManualIssue I- December 1998
Print System Database Parameters Introduction Print Exception Tables Programming Steps_-.. ..,“ 1Press the EXCEPT TABLES flexible button (FLASH 85, button #5). The following‘~~%~~message displays on the display phone: I PRINT EX TABLES PRESS HOLD I 2To print the Except Tables, press the HOLD button. The following message displays on the display phone: PPRINTING EX TABLES When the system finishes sending the requested information to the printer, a confirmation tone is heard. Description This command dumps the entire database as a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device. When printing information from the Exception Tables, the following data prints: +Allow Table A e:+Deny Table A oAllow Table B +Deny Table B + Special Table 1 +Special Table 2 + Special Table 3 0%Special Table 4 Refer to Figwe 12-5: Exeption Tables for an example of the Exception Tables database printout.Issue I- December 1998 STARPLUS Triad-S System Programming Manual
Print System Database Parameters Introduction r-1LLOW TABLE ASPECIAL TABLE 1 AREA CODE._----------- 3111ALLOWEDOFFICECODES 3212 3313 1414 3515 SPECIALTABLE2 AREACODE 3616 3717ALLOWEDOFFICECODES 3818 3919 1020SPECIAL TABLE 3 AREA CODE __--.-.._--._.__--....~-~DENY TABLE AALLOWED OFFICE CODES 0106 0207 0308 SPECIALTABLE4 HOMEAREACODE .LLOWED OFFICE CODES 04 09 05 10AALLOW TABLE B 01 11 02 1203 13 04 14 05 15 06 16 07 17 08 18 09 19 10 20DENY TABLE B .._-..-.-... 01 0602 07 03 08 04 09 05 10 Figure 12-5: Exception Tables STARPLUS Triad-S System Programming ManualIssue 7 - December 7998
Print System Database Parameters Introduction Print System Speed Numbers Programming Steps 1Press the SYSTEM SPEED flexible button (FLASH 85, button #8). The following message displays on the display phone: PRINT SYS SPEED NO PRESS HOLO 2To print the System Speed bins, press the HOLD button. The following displays on the display phone: I PRINTING SYS SPEED NO I When the system finishes sending the requested information to the printer, a confirmation tone is heard. Description This command dumps the entire database as a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device. issue 1 - December 1998STARPLUS Triad-S System Programming bfanual