Customer Database Programming Database Upload/Download Routine1-25 3This displays the Send XMODEM screen on the PC monitor. Enter a path and file name for the database file and press and the desired file is uploaded to the system. Send XMODEM Please enter filename: 4A Confirmation tone is heard after the uploaded is complete and you are returned to the ADM> prompt. 5Enter an M at the ADM> prompt and press . adm>m exiting admin...DATE: 12/01/98TIME: 15:41:04 exiting maintenance utility... sOn the PC, press + . Press to exit Procomm and return to the DOS prompt. 7After the upload procedure is completed, the system MUST be reset for full activation of the database programming to take effect. STARPLUS Triad-S System Programming ManualIssue I- December 1998
Customer Database Programming Database Upload/Download RoutineIssue I- December 1998 STARPLUS Triad-S System Programming Manual
: Programming Steps If the system is in the programming mode, continue using the program codes. If starting to program here, enter the programming mode. Refer to Chapter 1: Customer Database Programming. IPress FLASH and dial [Ol]. The following message displays: SYSTEM TIMERS ENTER BUTTON NUMBER . Description This section describes the procedures and steps to program system timers in the System Timers programming area. The buttons on the digital terminal are illustrated on the following page: issue I- December 1998STARPLUS Triad-S System Programming Manual
System Parameters Programming System TimersSYSTEMHOLD RECALL *llPRESET FORWARD +- CONFlDlSATIMER 119MSG WAIT REMINDER *113AUTO CALL BACK TIMER 4#-EXCL HOLD ATTENDANT RECALLRECALL %l?x2iTl #izKEElCALL FWD NO/ANSWERPAUSE TIMER %- *mPAGINGCO RING TIMEOUTDETECT *- 4#nHOOK FLASHHOOK FLASH DEBOUNCE %+- *115REMINDERRELEASE GUARD RINGTIMERTRANSFER RECALL $14CALL PARK TIMER *m DISAISLTRECEIVER 9112SMDR CALL QUALIFICATION 4kEiEKaINTER-DIGIT TIMEOUT %k-Program Flex FeatureDefault CodeButton (after initialization)FLASH 011System Hold Recall060 seconds 2Exclusive Hold Recall180 seconds 3Attendant Recall Timer01 minutes 4Transfer Recall Timer045 seconds 5Preset Forward Timer10 seconds 6Call Forward No/Answer 015seconds 7Pause Timer2 seconds 8Call Park Recall Timer180 seconds 9Conf erence/DISA Timer10 minutes 10Paging Timeout Timer15 seconds 11CO Ring Detect Timer300 ms 12SLT DTMF Receiver Timer020 seconds 13MSG Wait Reminder Tone000 minutes 14SLT Hook Flash Timer 10 (1 second) 15SLT Hook Flash Debounce010 (.I seconds) 16SMDR Call Qualification Timer30 seconds 17Auto Call Back Timer 03 seconds (enabled) 18Reminder Ring Timer00 seconds (disabled) 19Release Guard Timer300 ms 20Inter-Digit Timeout5 seconds Table 2-l: System Timers Defaults Issue I- December 1998 STARPLUS Triad-S System Programming Manual
System Parameters Programming System Timers2-3 System Hold Recall Timer Programming StepsIPress the SYSTEM HOLD RECALL TIMER flexible button(FLASH 01, button 1). The following message displays: SYS HOLD RECALL000-300 060 2Enter a 3-digit timer value on the dial pad that corresponds to 000-300 seconds. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This timer determines the time before a call placed on System Hold recalls the station placing the hold, If unanswered by that station, the call recalls the attendant. By default, the System Hold Recall Timer is set for 60 seconds and is variable from 000-300 seconds. An entry of 000 disables the timer and there is no recall. Exclusive Hold Recall Timer Programming Steps 1Press the EXCLUSIVE HOLD RECALL TIMER flexible button (FLASH 01, button #2).The following message displays: . EXC HOLD RECALL000-300180 2Enter a 3-digit timer value on the dial pad that corresponds to 000-300 seconds, 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This timer determines the time before a call placed on Exclusive Hold recalls the station placing the Hold. If unanswered by that station, the call recalls the attendant. By default, the Exclusive Hold Recall Timer is set for 180 seconds and is variable from 000-300 seconds. An entry of 000 disables the timer and there is no recall. STARPLUS Triad-S System Programming ManualIssue I- December 1998
2-4 ‘-: :..-. System Parameters Programming System Timers Attendant Recall Timer Programming Steps 1Press the ATTENDANT RECALL TIMER flexible button (FLASH 01, button #3). The following message displays: ATND RECALL TIMER00-6001 6 zEnter a 2-digit timer value on the dial pad that corresponds to 00-60 minutes. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This timer determines the time a recalling call rings at the attendant station(s) before the system releases the line. When a CO Line recalls to the Attendant station and is still unanswered, the system releases the line at the expiration of this timer and automatically places the line to an idle condition. By default, the Attendant Recall Timer is set for 1 minute and is variable from W-60 minutes. An entry of 00 causes the Attendant(s) to ring until answered. Transfer Recall Timer Programming Steps 1Press the TRANSFER RECALL TIMER flexible button (FLASH 01, button #4). The following message displays: 2Enter a 3-digit timer value on the dial pad that corresponds to 000-300 seconds. TRA;;;ER RECALL000-300 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This timer determines the time a transferred call rings at the station receiving the transfer before it recalls the station making the transfer. If unanswered by that station, the call recalls the attendant. By default, the Transfer Recall Timer is set for 45 seconds and is variable from 000-300 seconds. A 000 entry disables the timer and there is no recall. Issue I - December 1998STARPLUS Triad-S System Programming Manual
System Parameters Programming System Timers 2-5 Preset Forward Timer _.‘, Programming Steps e 5. yi;....:_,. 1e.; :.;:’1Press the PRESET FORWARD TIMER flexible button (FLASH 01, button #5). The following message displays: I PRESET FWD TIMER00-9910I 2Enter a 2-digit timer value on the dial pad that corresponds to 01-99 seconds. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This timer determines the time an outside line rings before being forwarded to a predetermined station. This entry works with Preset Forward station assignments in Station Programming. More than one station can be forwarded to the same party.Initial incoming CO lines follow the Preset Call Forward Timer when encountering a station in the Forward/No Answer mode. This timer also governs the time the DISA call rings at a station before returning to intercom dial tone, if not answered. By default, the Preset Forward Timer is set at 10 seconds and is variable from 01-99 seconds. If no preset forward destination is programmed, the feature is disabled. Call Forward / No Answer Timer Programming Steps 1Press the CALL FORWARD NO/ANSWER TIMER flexible button(FLASH 01, button #6).The following message displays: I?i* 4”_ &.es-L3CALL FWD NO ANS000-600-I-i:.Y015 2Enter a 3-digit timer value on the dial pad that corresponds to 000-600 seconds. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. STARPLUS Triad-S Sysfem Programming Manual Issue I- December 7998
ISystem Parameters Programming System Timers Description This timer is used when a station in the system specifies that no answer calls be forwarded to another station. The timer determines how long an intercom or transferred call rings before it is considered a no- answer call. The call then forwards to the designated station for handling. By default, the Call Forward No/Answer Timer is set for 15 seconds and is variable from 000-600 seconds. lnifiul incoming CO lines follow the Preset Call Forward Timer when encountering a station in the Forward / No Answer mode. Pause Timer Programing Steps 1Press the PAUSE TIMER flexible button (FLASH 01, button #7). The following message displays: + PAUSE TIMERl-92 . 2Enter a l-digit timer value on the dial pad that corresponds to l-9 seconds. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This timer determines the length of the pause when programmed for use with speed dialing and LCR Insert Tables. By default, the Pause Timer is set at 2 seconds and is variable from l-9 seconds. There is no 0 entry. Use of this feature may afect Centrex transfers.Issue I- December 7998 STARPLUS Triad-S System Programming Manual
System Parameters Programming System Timers 2-7 Call Park Recall Timer in-., Programming Steps:: ”&ITIPress the CALL PARK RECALL TIMER flexible button (FLASH 01, button #8). The following message displays: CALL PARK TIMER000-600180 2Enter a 3-digit timer value on the dial pad that corresponds to 001-600 seconds. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This timer determines the time before a call placed in a call park location recalls the station placing the call in park. If unanswered by that station, the call recalls the attendant. By default, the Call Park Recall Timer is set at 180 seconds and is variable from 000-600 seconds. A 000 entry disables the timer and there is no recall.Conference / DISA Timer Programming Steps 1Press the CONFERENCEIDISA TIMER flexible button (FLASH 01, button #9). The following message displays: CONFERENCE TIMER00-9910 .. 2Enter a 2-digit timer value on the dial pad that corresponds to 01-99 minutes. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. STARPLUS Triad-S System Programming Manualissue I - December 1998
2-8System Parameters Programming System Timers Description This timer determines the time an unsupervised conference can continue after the initiator of the conference has exited. By default, the Conference/DISA Timer is set at 10 minutes and is variable from Ol- 99 minutes. A 00 entry disables the timer and no automatic disconnect occurs.The Conference Timer also allows the system administrator to control the time a DISA caller is allowed after establishing o Trunk-to- Trunk call. At the expiration of the Conference Timer, u tone is presented to both DISAparties, then one minute later the system automatically releases both trunks. The Conference Timer does not affect or control a DISA-to- Station call. Paging Time-out Timer Programming Steps 1Press the PAGING TIMEOUT TIMER flexible button (FLASH 01, button #lo). The following message displays: I PAGING TIMEOUT00-6015I zEnter a 2-digit timer value on the dial pad that corresponds to 01-60 seconds. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This timer determines the maximum length of a page announcement (internal, external or all call). The system automatically disconnects the page at the end of this time unless the person making the page has already hung up. By default, the Paging Time-out Timer is set at 15 seconds and is variable from 01-60 seconds. A 00 entry disables the timer and pages are not limited in length. This will a&et use of the Meet Me Page feature. issue I- December 1998STARPLUS Triad-S System Programming Manual