    							Customer Database Programming
    Database Upload/Download Routine1-25
    3This displays the Send XMODEM screen on the PC monitor. Enter a path and file name
    for the database file and press  and the desired file is uploaded to the system.
    Send XMODEM
    Please enter filename:
    4A Confirmation tone is heard after the uploaded is complete and you are returned to the
    ADM> prompt.
    5Enter an M at the ADM> prompt and press .
    adm>m
    exiting admin...DATE: 
    12/01/98TIME: 15:41:04
    exiting maintenance utility...
    sOn the PC, press  + . Press  to exit Procomm and return to the DOS
    prompt.
    7After the upload procedure is completed, the system MUST be reset for full activation
    of the database programming to take effect.
    STARPLUS Triad-S System Programming ManualIssue I- December 1998 
    						
    							Customer Database Programming
    Database Upload/Download RoutineIssue I- December 1998
    STARPLUS Triad-S System Programming Manual 
    						
    							:
    Programming Steps
    If the system is in the programming mode, continue using the program codes. If starting to program here,
    enter the programming mode. Refer to Chapter 1: Customer Database Programming.
    IPress FLASH and dial [Ol]. The following message displays:
    SYSTEM TIMERS
    ENTER BUTTON NUMBER
    .
    Description
    This section describes the procedures and steps to program system timers in the System Timers
    programming area. The buttons on the digital terminal are illustrated on the following page:
    issue I- December 1998STARPLUS Triad-S System Programming Manual 
    						
    							System Parameters Programming
    System TimersSYSTEMHOLD
    RECALL
    *llPRESET
    FORWARD
    +-
    CONFlDlSATIMER
    119MSG WAIT
    REMINDER
    *113AUTO CALL
    BACK TIMER
    4#-EXCL HOLD
    ATTENDANT
    RECALLRECALL
    %l?x2iTl #izKEElCALL FWD
    NO/ANSWERPAUSE TIMER
    %- *mPAGINGCO RING
    TIMEOUTDETECT
    *- 4#nHOOK FLASHHOOK FLASH
    DEBOUNCE
    %+- *115REMINDERRELEASE GUARD
    RINGTIMERTRANSFER
    RECALL
    $14CALL PARK
    TIMER
    *m
    DISAISLTRECEIVER
    9112SMDR CALL
    QUALIFICATION
    4kEiEKaINTER-DIGIT
    TIMEOUT
    %k-Program Flex
    FeatureDefault
    CodeButton
    (after initialization)FLASH
    011System Hold Recall060 seconds
    2Exclusive Hold Recall180 seconds
    3Attendant Recall Timer01 minutes
    4Transfer Recall Timer045 seconds
    5Preset Forward Timer10 seconds
    6Call Forward No/Answer
    015seconds
    7Pause Timer2 seconds
    8Call Park Recall Timer180 seconds
    9Conf erence/DISA Timer10 minutes
    10Paging Timeout Timer15 seconds
    11CO Ring Detect Timer300 ms
    12SLT DTMF Receiver Timer020 seconds
    13MSG Wait Reminder Tone000 minutes
    14SLT Hook Flash Timer
    10 (1 second)
    15SLT Hook Flash Debounce010 (.I seconds)
    16SMDR Call Qualification Timer30 seconds
    17Auto Call Back Timer
    03 seconds (enabled)
    18Reminder Ring Timer00 seconds (disabled)
    19Release Guard Timer300 ms
    20Inter-Digit Timeout5 seconds
    Table 2-l: System Timers Defaults
    Issue I- December 1998
    STARPLUS Triad-S System Programming Manual 
    						
    							System Parameters Programming
    System Timers2-3
    System Hold Recall Timer
    Programming StepsIPress the SYSTEM HOLD RECALL TIMER flexible button(FLASH 01, button 1). The
    following message displays:
    SYS HOLD RECALL000-300
    060
    2Enter a 3-digit timer value on the dial pad that corresponds to 000-300 seconds.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This timer determines the time before a call placed on System Hold recalls the station placing the hold, If
    unanswered by that station, the call recalls the attendant. By default, the System Hold Recall Timer is set for
    60 seconds and is variable from 000-300 seconds. An entry of 000 disables the timer and there is no recall.
    Exclusive Hold Recall Timer
    Programming Steps
    1Press the EXCLUSIVE HOLD RECALL TIMER flexible button (FLASH 01, button #2).The following message displays:
    .
    EXC HOLD RECALL000-300180
    2Enter a 3-digit timer value on the dial pad that corresponds to 000-300 seconds,
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This timer determines the time before a call placed on Exclusive Hold recalls the station placing the Hold. If
    unanswered by that station, the call recalls the attendant. By default, the Exclusive Hold Recall Timer is set
    for 
    180 seconds and is variable from 000-300 seconds. An entry of 000 disables the timer and there is no
    recall.
    STARPLUS Triad-S System Programming ManualIssue I- December 1998 
    						
    							2-4
    ‘-: :..-.
    System Parameters Programming
    System Timers
    Attendant Recall Timer
    Programming Steps
    1Press the ATTENDANT RECALL TIMER flexible button (FLASH 01, button #3). The
    following message displays:
    ATND RECALL TIMER00-6001
    6
    zEnter a 2-digit timer value on the dial pad that corresponds to 00-60 minutes.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This timer determines the time a recalling call rings at the attendant station(s) before the system releases
    the line. When a CO Line recalls to the Attendant station and is still unanswered, the system releases the
    line at the expiration of this timer and automatically places the line to an idle condition. By default, the
    Attendant Recall Timer is set for 
    1 minute and is variable from W-60 minutes. An entry of 00 causes the
    Attendant(s) to ring until answered.
    Transfer Recall Timer
    Programming Steps
    1Press the TRANSFER RECALL TIMER flexible button (FLASH 01, button #4). The
    following message displays:
    2Enter a 3-digit timer value on the dial pad that corresponds to 000-300 seconds.
    TRA;;;ER RECALL000-300
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This timer determines the time a transferred call rings at the station receiving the transfer before it recalls
    the station making the transfer. If unanswered by that station, the call recalls the attendant. By default, the
    Transfer Recall Timer is set for 
    45 seconds and is variable from 000-300 seconds. A 000 entry disables the
    timer and there is no recall.
    Issue I - December 1998STARPLUS Triad-S System Programming Manual 
    						
    							System Parameters Programming
    System Timers
    2-5
    Preset Forward Timer
    _.‘, Programming Steps
    e
    5. yi;....:_,. 1e.; :.;:’1Press the PRESET FORWARD TIMER flexible button (FLASH 01, button #5). The
    following message displays:
    I
    PRESET FWD TIMER00-9910I
    2Enter a 2-digit timer value on the dial pad that corresponds to 01-99 seconds.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This timer determines the time an outside line rings before being forwarded to a predetermined station. This
    entry works with Preset Forward station assignments in Station Programming. More than one station can be
    forwarded to the same party.Initial incoming CO lines follow the Preset 
    Call Forward Timer when
    encountering a station in the Forward/No Answer mode.
    This timer also governs the time the DISA call rings at a station before returning to intercom dial tone, if not
    answered. By default, the Preset Forward Timer is set at 
    10 seconds and is variable from 01-99 seconds. If
    no preset forward destination is programmed, the feature is disabled.
    Call Forward / No Answer Timer
    Programming Steps
    1Press the CALL FORWARD NO/ANSWER TIMER flexible button(FLASH 01, button #6).The following message displays:
    I?i*
    4”_ &.es-L3CALL FWD NO ANS000-600-I-i:.Y015
    2Enter a 3-digit timer value on the dial pad that corresponds to 000-600 seconds.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    STARPLUS Triad-S Sysfem Programming Manual
    Issue I- December 7998 
    						
    							 ISystem Parameters Programming
    System Timers
    Description
    This timer is used when a station in the system specifies that no answer calls be forwarded to another
    station. The timer determines how long an intercom or transferred call rings before it is considered a no-
    answer call. The call then forwards to the designated station for handling. By default, the Call Forward
    No/Answer Timer is set for 15 seconds and is variable from 
    000-600 seconds.
    lnifiul incoming CO lines follow the Preset Call Forward Timer when
    encountering a station in the Forward 
    / No Answer mode.
    Pause Timer
    Programing Steps
    1Press the PAUSE TIMER flexible button (FLASH 01, button #7). The following message
    displays:
    +
    PAUSE TIMERl-92
    .
    2Enter a l-digit timer value on the dial pad that corresponds to l-9 seconds.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This timer determines the length of the pause when programmed for use with speed dialing and LCR Insert
    Tables. By default, the Pause Timer is set at 2 seconds and is variable from l-9 seconds. There is no 0
    entry. Use of this feature may afect Centrex transfers.Issue I- December 7998
    STARPLUS Triad-S System Programming Manual 
    						
    							System Parameters Programming
    System Timers
    2-7
    Call Park Recall Timer
    in-., Programming Steps:: ”&ITIPress the CALL PARK RECALL TIMER flexible button (FLASH 01, button #8). The
    following message displays:
    CALL PARK TIMER000-600180
    2Enter a 3-digit timer value on the dial pad that corresponds to 001-600 seconds.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This timer determines the time before a call placed in a call park location recalls the station placing the call
    in park. If unanswered by that station, the call recalls the attendant. By default, the Call Park Recall Timer is
    set at 
    180 seconds and is variable from 000-600 seconds. A 000 entry disables the timer and there is no
    recall.Conference 
    / DISA Timer
    Programming Steps
    1Press the CONFERENCEIDISA TIMER flexible button (FLASH 01, button #9). The
    following message displays:
    CONFERENCE TIMER00-9910
    ..
    2Enter a 2-digit timer value on the dial pad that corresponds to 01-99 minutes.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    STARPLUS Triad-S System Programming Manualissue I - December 1998 
    						
    							2-8System Parameters Programming
    System Timers
    Description
    This timer determines the time an unsupervised conference can continue after the initiator of the
    conference has exited. By default, the 
    Conference/DISA Timer is set at 10 minutes and is variable from Ol-
    99 minutes. A 00 entry disables the timer and no automatic disconnect occurs.The Conference Timer also allows the system 
    administrator to control the
    time a 
    DISA caller is allowed after establishing o Trunk-to- Trunk call. At
    the expiration of the Conference Timer, 
    u tone is presented to both DISAparties, then one minute later the system automatically releases both
    trunks. 
    The Conference Timer does not affect or control a DISA-to-
    Station call.
    Paging Time-out Timer
    Programming Steps
    1Press the PAGING TIMEOUT TIMER flexible button (FLASH 01, button #lo). The
    following message displays:
    I
    PAGING TIMEOUT00-6015I
    zEnter a 2-digit timer value on the dial pad that corresponds to 01-60 seconds.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This timer determines the maximum length of a page announcement (internal, external or all call). The
    system automatically disconnects the page at the end of this time unless the person making the page has
    already hung up. By default, the Paging Time-out Timer is set at 15 seconds and is variable from 
    01-60
    seconds. A 00 entry disables the timer and pages are not limited in length. This 
    will a&et use of the Meet
    Me Page feature.
    issue I- December 1998STARPLUS Triad-S System Programming Manual 
    						