.- CO Line Attributes Programming Page C Introduction3-23 Description This option lets the user adjust the reseize timer on a per CO Line basis. The reseize timer can be used on .$C..;.x c.- sr,..any trunk type. This timer sets the time period that a trunk is held disconnected after receiving a disconnect ‘Gbefore being reseized when a device is queued for a member of the trunk group. By default, the Reseize Timer is set for two seconds. Guard Timer Programming Steps 1Press the GUARD TIMER button (FLASH 40, Page C, button #4) in the flexible button field. The following message displays: I GUARD TIMERl-60 50I / 2Enter a 3-digit value on the dial pad which corresponds to I-60 (100 ms to 6 seconds). 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description The outgoing guard timer is the length of time a tie trunk is held busy to outgoing seizure after a valid release is detected. By default, the Guard Timer is set for five seconds. Preset Forward Timer Programming Steps 1Press the PRESET FWD TIMER flexible button (FLASH 40, Page C, button #5). The following message displays: PRESET FWD TIMER00-9900 2Enter a 2-digit timer value on the dial pad which corresponds to 00-99 seconds. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. STARPLUS Triad-S System Programming ManualIssue I- December 1998
3-24CO Line Attributes Programming Miscellaneous CO Parameters Descriptiop This timer determines the time an outside line rings before being forwarded to a predetermined destination, If a forward destination is programmed in the CO line field, the CO calls forward to that destination after the CO preset forward timer expires. This forward occurs regardless of how many stations the line is ringing. The digits entered for the CO line are sent in the station field.This feature applies to initial CO ringing lines only and works with Preset Forward CO Line assignments. By default, the CO Line Preset Forward Timer is set at 10 seconds and is variable from 00-99 seconds. A [00] entry disables the timer and the feature is disabled. Miscellaneous CO Parameters Programming Steps If the system is in the programming mode, continue using the program codes. If starting to program here, enter the programming mode first. 1Press FLASH and dial [41]. The following message displays: CO FEATURES ENTER BUTTON NUMBER 2Select any of the features by pressing the appropriate flexible button(s) in the flexible field. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description When entering the Miscellaneous CO Parameters programming area the buttons on the digital terminal are defined as shown below: Issue I - December 1998STARPLLJS Triad-S System Programming Manual
I :. --. CO Line Attributes Programming Miscellaneous CO Parameters3-25 Dial Pulse Parameters &??,, Pwrammi”g steps
3-26CO Line Attributes Programming Miscellaneous CO Parameters issue I- December IQ98STARPLUS Triad-S System Programming ManualI
: . . . . --::.. Programming Steps If the system is in the programming mode, continue using the program codes, If starting to program here, enter the programming mode. If station features must be changed: 1Press FLASH and dial [50]. The following message displays: STATION ATTRIBUTES SELECT A STATION RANGE zEnter a 6-digit number for the station range being programmed. If one station is being programmed, enter that number twice (100100). ,-’ ‘. /f HOLD is pressed without entering a station range, ALL stations (1&l- 13 1) are selected. 3Press Button #I9 and the display updates.The display updates to current programming for Page A: XXX-XXX PAGE A ENTER BUTTON NUMBERWhere: .XXX-XXX = Station Range (100-131) Description This section describes the steps and procedures necessary to program station attributes. cl;g$Range programming enables the programmer to change a specific parameter or a few parameters for a rangei of stations, leaving intact the remaining data fields not requiring changes. Those data fields continue to operate with the previously programmed data. By default, Page A is shown, Issue 1 - December 1998STARPLUS Triad-S System Programming Manual
4-2Station Attributes ProgrammingPage A Introduction When programming the Page A features, the flexible buttons are mapped as follows:PAGE ACCESSDO NOT CONFERENCEEXECUTIVE DISTURB OVERRIDE *n %a %+13 %pi--RlPRIVACYSYSTEM SPEEDLINE QUEUING PREF LINEANSWER %15 %+m #ITILl #IT--i-lOHVOCALL FORWARD FORCED LCRACD SUPV BARGE-IN *n%+110 #a %i!cExlEXEC OVRDCO LINE RINGNAME / NUMBER BLOCKINGOPTIONS DISPLAY #L13 *114 Sk+- #CPAGE APAGE B #a 1118 9119e (301PAGE CNEXT (FWD) NEXT (BACK) NEW RANGE %D %kD 1123-%%n Paging Access Programming Steps 1Press the PAGE ACCESS flexible button (FLASH 50, Page A, button #I). The following message displays: PAGE ACCESSo-1ENABLED 2Enter a l-digit value on the dial pad to enable/disable the Paging Access feature. [0] = Disabled [I] = Enabled 3Press HOLD to save the entry. Confirmation tone is heard. Description Stations can individually be allowed or denied the ability to make pages. This applies to all internal and external zone paging. A station denied access to paging may still answer a meet-me page announcement. (Station COS 6 does not deny a station the ability to make a page.) By default, Paging is enabled at all stations.issue I- December 1998 STARPLUS Triad-S System Programming Manual
IStation Attributes Programming4-3 Page A Introduction Do Not Disturb Programming StepsPress the DO NOT DISTURB flexible button (FLASH 50. Page A, button #2). The following message displays: I DO NOT DISTURBO-l ENABLED I 2Enter a l-digit value on the dial pad to enable/disable the Do Not Disturb feature. [0] = Disabled [I] = Enabled 3Press HOLD to save the entry. Confirmation tone is heard. Description Stations can be individually allowed or denied the ability to place their telephone in Do Not Disturb. By default, Do Not Disturb is enabled at all stations. The first programmed attendant cannot utilize DND. Conference Enable / Disable (Per Station) Programming Steps 1Press the CONFERENCE flexible button (FLASH 50, Page A, button #3). The following message displays: CONFERENCEo-1ENABLED bEnter a l-digit value on the dial pad to enable/disable the Conference feature. [0] = Disabled [I] = Enabled 2Press HOLD to save the entry. Confirmation tone is heard. ““’ Description I This feature lets the system be programmed on a per Station basis for the ability to initiate a conference. STARPLUS Triad-S System Programming Manualissue I- December 1998
Station Attributes ProgrammingPage A introduction Executive Override Programming Steps 1Press the EXECUTIVE OVERRIDE flexible button (FLASH 50, Page A, button #4). The following message displays: EXEC OVERRIDEo-1 DISABLEDl . 2Enter a l-digit value on the dial pad to enable/disable the Executive Override feature. [0] = Disabled [I] = Enabled 3Press HOLD to save the entry. Confirmation tone is heard. Use of this feature when the Executive Override Warning Tone is disabled may be interpreted as a violation of federal, state, or local laws, and an invasion of privacy. Check applicable laws in your area before intruding on calls using this feature. A change in volume may occur on the CO line or intercom call after the barge-in occurs. Description This feature lets certain stations be designated as Executive stations with the ability to override and barge-in on other key sets engaged in a CO line or intercom conversation. If Supervisor Monitor with barge-in function is denied, this feature MUST be disabled An optional warning tone is programmed on a system wide basis to enable or disable the tone. This tone is presented to all parties prior to actual cut through of the third party.A separate condition was added to this feature that allows or disallows an Executive to override an extension. This prevents an extension with override capability from overriding an Executive’s station. By default, Executive Override is disabled for all stations. Supervisor Barge-In can be programmed in [FLASH so] [Button 131.Issue I- December 1998 STARPLUS Triad-S System Programming Manual
: Station Attributes Programming Page A introduction Privacy (Per Station) ,.-~~, Programming Steps.-A... Tc.;.: =-2 -:>i.
I4-6Station Attributes Programming Page A Introduction Privacy is enabled for all stations in default. Station Attempting toCO Line in Use by Another Station Access CO Line Privacy Enabled Privacy DisabledPrivacy EnabledPrivate Private (No Cut-through) (No Cut-through) Privacy DisabledPrivatePrivacy Released (No Cut-through)(Cut-through Allowed) Table 4-l: Station Privacy Flag System Speed Dial Access Programming Steps 1Press the SPEED flexible button (FLASH 50, Page A, button #6). The following message displays: SYSTEM SPEEDo-1ENABLED ,zEnter a l-digit value on the dial pad to enable/disable the Speed Dial feature. [0] = Disabled [I] = Enabled 3Press HOLD to save the entry. Confirmation tone is heard. Description Stations can be individually allowed or denied the ability to use system speed dial (20-99) numbers. The last 40 system speed numbers are not monitored by toll restriction. Stations cannot be prevented from using station speed dial. By default, System Speed Dialing is enabled at all stations.Issue I- December 1998 STARPLUS Triad-S System Programming Manual