System Parameters Programming System Timers CO Ring Detect Timer ,f?--, eProgramming Steps _.y: 7.:2:-1Press the CO RING DETECT TIMER flexible button(FLASH 01, button #ll). The following message displays: CO RING DETECT2-93 2Enter a l-digit timer value on the dial pad that corresponds to 2-9 (200 ms to 900 ms). 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This timer controls the time necessary to detect an outside line ringing into the system. By default, the CO Ring Detect Timer is set at 3 (300 ms), and is variable from 2-9 (200 ms to 900ms). There is no 0 or 1 entry.SLT DTMF Receiver Timer Programming Steps 1Press the SLT DTMF RECEIVER TIMER flexible button(FLASH 01, button #12). Thefollowing message displays: l SLT RCVR TIMER005-100 020 \ zEnter a 3-digit timer value on the dial pad that corresponds to 005-100 seconds. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description Single line telephones require the use of a DTMF receiver when going off-hook and dialing, When SMDR or toll restriction (via COS assignments) is enabled, a DTMF receiver monitors and screens the SLT digits for the duration of this timer. By adjusting this timer, the system administrator may free system DTMF receivers sooner if system SLT traffic is heavy, or provide a longer monitoring period if toll restriction becomes a problem. Note that when LCR is enabled, the DTMF receivers are released when the expected number of digits are dialed as entered in the LCR database. By default, the SLT DTMF Receiver Timer is set at 20 seconds and is variable from 005-100 seconds. STARPLUS Triad-S System Programming Manual Issue I- December 1998
System Parameters Programming System Timers Message Wait Reminder Tone Programming StepsIPress the MESSAGE WAIT REMINDER TONE flexible button(FLASH 01, button #13).The following message displays: M/WO;;NE TIMERooo- 104 b 2Enter a 3-digit timer value on the dial pad that corresponds to 000-104 minutes. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This timer determines the time between repeated reminder tones to a key telephone with a message waiting. Digital Hybrid station users may be reminded of a message waiting on their telephone with an audible signal presented at a timed interval. By default, the Message Wait Reminder Tone is set at 000 (disabled) and is variable from 000-104 minutes. SLT Hook Flash Timer Programming Steps 1Press the SLT HOOK FLASH TIMER following message displays:flexible button (FLASH 01, button #I 4). The I HOOK SWITCH TIME052010I 2Enter a 2-digit timer value on the dial pad that corresponds to 052.0 seconds in l/l 0 second increments. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This timer determines how long an SLT user presses the hook switch for it to be considered a valid on hook (disconnect) request, An on-hook shorter in duration (but longer than the Hook Switch Bounce Timer) isIssue I- December 1998 S TARP1 Us Triad-S Sys tern Programming Manual
System Parameters Programming System Timers considered a Hook Flash (transfer) request. Refer to Figure 2-l. By default, the SLT Hook Flash Timer is set at 10 (one second) and is variable from 0.5-2.0 seconds. Some Single Line telephones have a fixed or programmable Flash Timer(Flash or Tap button). This Hook Switch Timer must be set longer than theSL T Flash Timer to allow Hook Flash transfer. SLT Hook Flash Debounce Timer Programming Steps 1Press the SLT HOOK FLASH DEBOUNCE TIMER flexible button (FLASH 01, button #15). The following message displays: IHOOK SWT BOUNCEooo- 100 010I 2Enter a 3-digit timer value on the dial pad that corresponds to O-l seconds in 10 ms increments. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This timer determines the time needed to determine a valid on-hook or off-hook condition for single line telephones. On-Hook or Off-Hook signals that are shorter in duration than this timer are ignored by the system. Refer to Figure 2-I: &IO/Z Switch Activity. By default, the SLT Hook Flash Debounce Timer is set to 0.10 seconds and is variable from O-l seconds in 10 ms increments. This is a s-digit entry where 010 equals 0.1 seconds. STARPLUS Triad-S System Programming Manualissue I- December 1998
System Parameters Programming System Timers System Response Hook Switch Bounce Timer 0.l.2.3.4.5.6.7.8.91.O1.52.0 e= programmable rangeTIME(in seconds)Figure 2-l: Hook Switch Activity SMDR Call Qualification Timer Programming Steps 1Press the SMDR CALL QUAL TIMER flexible button(FLASH 01, button #16). The following message displays: I SMDR CALL QUAL00-6030I zEnter a 2-digit timer value on the dial pad that corresponds to 00-60 seconds in 1 second increments. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This feature determines the time needed to determine a valid SMDR call for reporting purposes. By default, the SMDR Call Qualification Timer is set to 30 seconds and is variable from 00-60 seconds in l-second increments. issue I- December 1998STARPLUS Triad-S System Programming Manual
System Parameters Programming System Timers 2-13 Automatic Call Back Timer Programming Steps 1Press the AUTO CALL BACK TIMER flexible button(FLASH 01, button #17). The following message displays: AUTO CALL BACK00-9903 * 2Enter a Z-digit timer value on the dial pad that corresponds to 00-99 seconds in 1 second increments. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This feature invokes a call back anytime a user listens to busy tone for a programmable period of time. By default, the Automatic Call Back Timer is set for 03 seconds (enabled), and is variable from 00-99 seconds. A value of 00 disables this timer. An Automatic Call Back does not occur when this timer is disabled. Reminder Ring Timer Programming Steps 1Press the REMINDER RING flexible button (FLASH 01, button #18). The following message displays: . REMINDER RING00-9900 2Enter a 2-digit timer value on the dial pad that corresponds to 00-99 seconds in 1 second increments. A value of 00 disables the timer, therefore the user only receives one ring burst at the beginning of the call. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description When a CO line rings at a busy station, the call rings at the station using muted ringing. The CO Line Ringing Option feature enables a user to receive a reminder ring instead of muted ring. This timer provides a reminder ring every time the timer expires, as long as the incoming CO line remains connected. If the user continues his present conversation and the CO party does not hang up, the Reminder Ring timer expires and STARPLIJS Triad-S System Programming ManualIssue I- December 1998
2-14System Parameters Programming System Timers the user receives another ring burst. When the key set user ends the existing call, ringing for the CO call reverts to normal ringing. By default, the Reminder Ring Timer is set to 00 second and is variable from OO- 99 seconds in 1 second increments. Release Guard Timer Programming Steps 1Press the RELEASE GUARD TIMER flexible button (FLASH 01, button #19). The following message displays: I RELEASE GUARD01-5003I 2Enter a 2-digit timer value on the dial pad that corresponds to 01-50 (0.1 to 5.0 seconds) sPress HOLD to save the entry. A confirmation tone is heard and the display updates. Description The Release Guard Timer is designed to accommodate variations from one Central Office to another. The timer is started whenever a CO line is released. If a user attempts to access a CO line before the Release Guard timer expires, his LED illuminates indicating the CO line was seized, however the CO line is not seized until the timer expires. The user DOES NOT receive a busy tone, but may get a delayed CO dial tone if the timer is set to a large value. By default, the Release Guard timer is set for 3 (for 300 ms), and is variable from 100 ms to 5 seconds. Inter-Digit Time-out Programming Steps 1Press the INTER-DIGIT TIMEOUT flexible button (FLASH 01, button #20). The following message displays: INTERDIGIT T/O01-9905 2Enter a 2-digit timer value on the dial pad that corresponds to 01-99 seconds in 1 second increments. Issue 1 - December 1998STARPLUS Triad-S System Programming Manual
System Parameters ProgrammingAdditional System Timers 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This feature provides inter-digit time-out programming on a system-wide basis and applies to intercom and LCR calls. DISA, DID. TIE inter-digit time-outs remain unaffected by this timer. By default, the Inter-Digit Time-out is set for 5 seconds, and is variable from l-99 seconds. Additional System Timers Programming Steps If the system is in the programming mode, continue using the program codes, If starting to program here, enter the programming mode. 1Press FLASH and dial [02]. The following message displays: ISYSTEM TIMERS ENTER BUTTON NUMBER I Description This section describes the procedures and steps necessary to program additional System Timers in the Timers programming area. STARPLUS Triad-S System Programming ManualIssue 1 - December 1998
2-16System Parameters Programming Additional System TimersSYSTEM REDIALATD DISPLAYCALL CVRG MODEM TIMER TIMERRING TIMER ANSWER T/O #E%lzi!zl %lzcLizl +Em PULSE DIAL I/ODTMF TIME TIMEROPERATION #15 #LLic2a%17 %D *: *- #+n #kKE ProgramFlex FeatureDef auk CodeButton (after initialization)Additional System Timers: FLASH 02 1Repeat Redial Timer 060 seconds 2ATD Display Timer 01 seconds 3Call Coverage Ring Timer5 seconds 4Modem Answer Time-out25 seconds 5Pulse Dial Inter-Digit Timer300 ms 6DTMF Time Operation 100 ms ON / IOOms OFF Table 2-2: Additional System Timers Defaults Repeat Redial Timer Programming Steps 1Press the RPT REDIAL TIMER flexible button (FLASH 02, button #I). The following message displays:;-.‘.;y:.,. ,. . :?yy.:: ;.,I . . IRPT EAL006-999 I 2Enter a 3-digit timer value on the dial pad that corresponds to 006-999 seconds. issue 7 - December 1998STARPLUS Triad-S System Programming Manual
System Parameters Programming Additional System Timers2-17 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description The feature lets a digital key station press a flexible button or dial a code and redial a busy or no-answer number at specific intervals. The user is signaled via a queue callback indication, The Redial flexible button flashes at the callback rate of 120 ipm for 15 seconds. If the station does not answer within 15 seconds, the callback is cancelled. If the station is busy with an internal/external call when the Redial queue callback occurs, the callback occurs after the user goes on-hook. By default, the Repeat Redial Timer is set for 1 minute (60) and is variable from 006-999 seconds. Attendant Display Timer Programming Steps 1Press the ATTENDANT DISPLAY TIMER flexible button (FLASH 02, button #2). The following message displays: ATTENDANT DISPLAY006-99901 2Enter a 2-digit timer value on the dial pad that corresponds to 00-99 seconds. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description The Attendant display timer modifies the way in which multiple calls ringing at the attendant station display. Currently, if two calls are ringing at an attendant station, when the station goes off hook, the first call is answered. The LCD updates to show the second call that is ringing which sometimes does not allow the station to view the current call’s LCD information. This timer keeps the current calls’ information on the LCD for the set time period, then shows any other calls ringing in at the time. By default, the Attendant Display Timer is set for 1 second and is variable from 00-99 seconds. STARPLUS Triad-S System Programming ManualIssue I- December 1998
2-18System Parameters Programming Additional System Timers Call Coverage Ring Timer Programming Steps 1Press the CALL CVRG RING TIMER flexible button (FLASH 02, button #3). The following message displays: CALLOgOVERAGE RING00-99 a aEnter a 2-digit timer value on the dial pad that corresponds to 00-99 seconds. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description A ringing Call Coverage button enables the user to place another station under a flex button. For additional information refer to Chapter 4: Table 4-3: Flex Button Codesfor Remote Programming. When that station rings with an internal or external call, the DSS button for that station rings or flashes. By default, the Call Coverage Ring Timer is set for 5 seconds and is variable from 00-99 seconds. A value of 00 results in the LED flashing but the call coverage station does not ring. Modem Answer Timer Programming Steps 1Press the MODEM ANSWER TIMER flexible button (FLASH 02, button #4). The following message displays: I MODEM ANSWER T/O025-09925I 2Enter a 2-digit timer value on the dial pad that corresponds to 025-099 seconds. 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description This timer determines how long the On Board modem provides a carrier tone to a distant modem. If a connection is not made at the end of this timer, the On Board modem hangs up. By default, the Modem Answer Timer is set for 25 seconds and is variable from 25-95, seconds. issue I- December 1998STARPLUS Triad-S System Programming Manual