Home > Vodavi > Communications System > Vodavi Starplus Triad S Description Manual

Vodavi Starplus Triad S Description Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Vodavi Starplus Triad S Description Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 710
    							System Parameters Programming
    System Timers
    CO Ring Detect Timer
    ,f?--,
    eProgramming Steps
    _.y: 7.:2:-1Press the CO RING DETECT TIMER flexible button(FLASH 01, button #ll). The
    following message displays:
    CO RING DETECT2-93
    2Enter a l-digit timer value on the dial pad that corresponds to 2-9 (200 ms to 900 ms).
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This timer controls the time necessary to detect an outside line ringing into the system. By default, the CO
    Ring Detect Timer is set at 3 (300 
    ms), and is variable from 2-9 (200 ms to 900ms). There is no 0 or 1 entry.SLT DTMF Receiver Timer
    Programming Steps
    1Press the SLT DTMF RECEIVER TIMER flexible button(FLASH 01, button #12). Thefollowing message displays:
    l
    SLT RCVR TIMER005-100
    020
    \
    zEnter a 3-digit timer value on the dial pad that corresponds to 005-100 seconds.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    Single line telephones require the use of a DTMF receiver when going off-hook and dialing, When SMDR or
    toll restriction (via COS assignments) is enabled, a DTMF receiver monitors and screens the SLT digits for the
    duration of this timer. By adjusting this timer, the system administrator may free system DTMF receivers
    sooner if system SLT traffic is heavy, or provide a longer monitoring period if toll restriction becomes a
    problem. Note that when LCR is enabled, the DTMF receivers are released when the expected number of
    digits are dialed as entered in the LCR database. By default, the SLT DTMF Receiver Timer is set at 20 seconds
    and is variable from 005-100 seconds.
    STARPLUS Triad-S System Programming Manual
    Issue I- December 1998 
    						
    							System Parameters Programming
    System Timers
    Message Wait Reminder Tone
    Programming StepsIPress the MESSAGE WAIT REMINDER TONE flexible button(FLASH 01, button 
    #13).The following message displays:
    M/WO;;NE TIMERooo- 104
    b
    2Enter a 3-digit timer value on the dial pad that corresponds to 000-104 minutes.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This timer determines the time between repeated reminder tones to a key telephone with a message
    waiting. Digital Hybrid station users may be reminded of a message waiting on their telephone with an
    audible signal presented at a timed interval. By default, the Message Wait Reminder Tone is set at 000
    (disabled) and is variable from 000-104 minutes.
    SLT Hook Flash Timer
    Programming Steps
    1Press the SLT HOOK FLASH TIMER
    following message displays:flexible button (FLASH 01, button #I 4). The
    I
    HOOK SWITCH TIME052010I
    2Enter a 2-digit timer value on the dial pad that corresponds to 052.0 seconds in l/l 0
    second increments.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This timer determines how long an SLT user presses the hook switch for it to be considered a valid on hook
    (disconnect) request, An on-hook shorter in duration (but longer than the Hook Switch Bounce Timer) isIssue I- December 1998
    S TARP1 Us Triad-S Sys tern Programming Manual 
    						
    							System Parameters Programming
    System Timers
    considered 
    a Hook Flash (transfer) request. Refer to Figure 2-l. By default, the SLT Hook Flash Timer is set
    at 
    10 (one second) and is variable from 0.5-2.0 seconds.
    Some Single Line telephones have a fixed or programmable Flash Timer(Flash or Tap button). This Hook Switch Timer must be set longer 
    than theSL T Flash Timer to allow Hook Flash transfer.
    SLT Hook Flash Debounce Timer
    Programming Steps
    1Press the SLT HOOK FLASH DEBOUNCE TIMER flexible button (FLASH 01, button
    #15). The following message displays:
    IHOOK SWT BOUNCEooo- 100
    010I
    2Enter a 3-digit timer value on the dial pad that corresponds to O-l seconds in 10 ms
    increments.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This timer determines the time needed to determine a valid on-hook or off-hook condition for single line
    telephones. On-Hook or Off-Hook signals that are shorter in duration than this timer are ignored by the
    system. Refer to Figure 
    2-I: &IO/Z Switch Activity. By default, the SLT Hook Flash Debounce Timer is set to
    0.10 seconds and is variable from O-l seconds in 10 ms increments. This is a 
    s-digit entry where 010 equals
    0.1 seconds.
    STARPLUS Triad-S System Programming Manualissue I- December 1998 
    						
    							System Parameters Programming
    System Timers
    System
    Response
    Hook Switch
    Bounce
    Timer
    0.l.2.3.4.5.6.7.8.91.O1.52.0
    e= programmable rangeTIME(in seconds)Figure 2-l: Hook Switch Activity
    SMDR Call Qualification Timer
    Programming Steps
    1Press the SMDR CALL QUAL TIMER flexible button(FLASH 01, button #16). The
    following message displays:
    I
    SMDR CALL QUAL00-6030I
    zEnter a 2-digit timer value on the dial pad that corresponds to 00-60 seconds in 1
    second increments.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This feature determines the time needed to determine a valid SMDR call for reporting purposes. By default,
    the SMDR Call Qualification Timer is set to 30 seconds and is variable from 
    00-60 seconds in l-second
    increments.
    issue I- December 1998STARPLUS Triad-S System Programming Manual 
    						
    							System Parameters Programming
    System Timers
    2-13
    Automatic Call Back Timer
    Programming Steps
    1Press the AUTO CALL BACK TIMER flexible button(FLASH 01, button #17). The
    following message displays:
    AUTO CALL BACK00-9903
    *
    2Enter a Z-digit timer value on the dial pad that corresponds to 00-99 seconds in 1
    second increments.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This feature invokes a call back anytime a user listens to busy tone for a programmable period of time. By
    default, the Automatic Call Back Timer is set for 
    03 seconds (enabled), and is variable from 00-99 seconds. A
    value of 00 disables this timer. An Automatic Call Back does not occur when this timer is disabled.
    Reminder Ring Timer
    Programming Steps
    1Press the REMINDER RING flexible button (FLASH 01, button #18). The following
    message displays:
    .
    REMINDER RING00-9900
    2Enter a 2-digit timer value on the dial pad that corresponds to 00-99 seconds in 1 second
    increments. A value of 00 disables the timer, therefore the user only receives one ring
    burst at the beginning of the call.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    When a CO line rings at a busy station, the call rings at the station using muted ringing. The CO Line Ringing
    Option feature enables a user to receive a reminder ring instead of muted ring. This timer provides a
    reminder ring every time the timer expires, as long as the incoming CO line remains connected. If the user
    continues his present conversation and the CO party does not hang up, the Reminder Ring timer expires and
    STARPLIJS Triad-S System Programming ManualIssue I- December 1998 
    						
    							2-14System Parameters Programming
    System Timers
    the user receives another ring burst. When the key set user ends the existing call, ringing for the CO call
    reverts to normal ringing. By default, the Reminder Ring Timer is set to 00 second and is variable from 
    OO-
    99 seconds in 1 second increments.
    Release Guard Timer
    Programming Steps
    1Press the RELEASE GUARD TIMER flexible button (FLASH 01, button #19). The
    following message displays:
    I
    RELEASE GUARD01-5003I
    2Enter a 2-digit timer value on the dial pad that corresponds to 01-50 (0.1 to 5.0
    seconds)
    sPress HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    The Release Guard Timer is designed to accommodate variations from one Central Office to another. The
    timer is started whenever a CO line is released. If a user attempts to access a CO line before the Release
    Guard timer expires, his LED illuminates indicating the CO line was seized, however the CO line is not
    seized until the timer expires. The user DOES NOT receive a busy tone, but may get a delayed CO dial tone if
    the timer is set to a large value. By default, the Release Guard timer is set for 
    3 (for 300 ms), and is variable
    from 100 ms to 5 seconds.
    Inter-Digit Time-out
    Programming Steps
    1Press the INTER-DIGIT TIMEOUT flexible button (FLASH 01, button #20). The
    following message displays:
    INTERDIGIT T/O01-9905
    2Enter a 2-digit timer value on the dial pad that corresponds to 01-99 seconds in 1
    second increments.
    Issue 1 - December 1998STARPLUS Triad-S System Programming Manual 
    						
    							System Parameters ProgrammingAdditional System Timers
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This feature provides inter-digit time-out programming on a system-wide basis and applies to intercom and
    LCR calls. DISA, DID. TIE inter-digit time-outs remain unaffected by this timer. By default, the Inter-Digit
    Time-out is set for 
    5 seconds, and is variable from l-99 seconds.
    Additional System Timers
    Programming Steps
    If the system is in the programming mode, continue using the program codes, If starting to program here,
    enter the programming mode.
    1Press FLASH and dial [02]. The following message displays:
    ISYSTEM TIMERS
    ENTER BUTTON NUMBER
    I
    Description
    This section describes the procedures and steps necessary to program additional System Timers in the
    Timers programming area.
    STARPLUS Triad-S System Programming ManualIssue 1 - December 1998 
    						
    							2-16System Parameters Programming
    Additional System TimersSYSTEM 
    REDIALATD DISPLAYCALL CVRG
    MODEM
    TIMER
    TIMERRING TIMER
    ANSWER T/O
    #E%lzi!zl %lzcLizl +Em
    PULSE DIAL I/ODTMF TIME
    TIMEROPERATION
    #15 #LLic2a%17 %D
    *: *- #+n #kKE
    ProgramFlex
    FeatureDef auk
    CodeButton
    (after initialization)Additional System Timers:
    FLASH 02 1Repeat Redial Timer
    060 seconds
    2ATD Display Timer
    01 seconds
    3Call Coverage Ring Timer5 seconds
    4Modem Answer Time-out25 seconds
    5Pulse Dial Inter-Digit Timer300 ms
    6DTMF Time Operation
    100 ms ON / IOOms OFF
    Table 2-2: Additional System Timers Defaults
    Repeat Redial Timer
    Programming Steps
    1Press the RPT REDIAL TIMER flexible button (FLASH 02, button #I). The following
    message displays:;-.‘.;y:.,. ,. . :?yy.:: ;.,I . .
    IRPT EAL006-999
    I
    2Enter a 3-digit timer value on the dial pad that corresponds to 006-999 seconds.
    issue 7 - December 1998STARPLUS Triad-S System Programming Manual 
    						
    							System Parameters Programming
    Additional System Timers2-17
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    The feature lets a digital key station press a flexible button or dial a code and redial a busy or no-answer
    number at specific intervals. The user is signaled via a queue callback indication, The Redial flexible button
    flashes at the callback rate of 120 ipm for 15 seconds. If the station does not answer within 15 seconds, the
    callback is cancelled. If the station is busy with an internal/external call when the Redial queue callback
    occurs, the callback occurs after the user goes on-hook. By default, the Repeat Redial Timer is set for 1
    minute 
    (60) and is variable from 006-999 seconds.
    Attendant Display Timer
    Programming Steps
    1Press the ATTENDANT DISPLAY TIMER flexible button (FLASH 02, button #2). The
    following message displays:
    ATTENDANT DISPLAY006-99901
    2Enter a 2-digit timer value on the dial pad that corresponds to 00-99 seconds.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    The Attendant display timer modifies the way in which multiple calls ringing at the attendant station display.
    Currently, if two calls are ringing at an attendant station, when the station goes off hook, the first call is
    answered. The LCD updates to show the second call that is ringing which sometimes does not allow the
    station to view the current call’s LCD information. This timer keeps the current calls’ information on the LCD
    for the set time period, then shows any other calls ringing in at the time. By default, the Attendant Display
    Timer is set for 1 second and is variable from 
    00-99 seconds.
    STARPLUS Triad-S System Programming ManualIssue I- December 1998 
    						
    							2-18System Parameters Programming
    Additional System Timers
    Call Coverage Ring Timer
    Programming Steps
    1Press the CALL CVRG RING TIMER flexible button (FLASH 02, button #3). The
    following message displays:
    CALLOgOVERAGE RING00-99
    a
    aEnter a 2-digit timer value on the dial pad that corresponds to 00-99 seconds.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    A ringing Call Coverage button enables the user to place another station under a flex button. For additional
    information refer to Chapter 
    4: Table 4-3: Flex Button Codesfor Remote Programming. When that station
    rings with an internal or external call, the DSS button for that station rings or flashes. By default, the Call
    Coverage Ring Timer is set for 
    5 seconds and is variable from 00-99 seconds. A value of 00 results in the
    LED flashing but the call coverage station does not ring.
    Modem Answer Timer
    Programming Steps
    1Press the MODEM ANSWER TIMER flexible button (FLASH 02, button #4). The
    following message displays:
    I
    MODEM ANSWER T/O025-09925I
    2Enter a 2-digit timer value on the dial pad that corresponds to 025-099 seconds.
    3Press HOLD to save the entry. A confirmation tone is heard and the display updates.
    Description
    This timer determines how long the On Board modem provides a carrier tone to a distant modem. If a
    connection is not made at the end of this timer, the On Board modem hangs up. By default, the Modem
    Answer Timer is set for 25 seconds and is variable from 
    25-95, seconds.
    issue I- December 1998STARPLUS Triad-S System Programming Manual 
    						
    All Vodavi manuals Comments (0)

    Related Manuals for Vodavi Starplus Triad S Description Manual