System Parameters Programming System Parameters Programming [ 0] = Disables Relay 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. e-.=Each time the user presses a relay button, the LCD updates with the relay number and the function assigned. . .,‘;-“-:to it. Description The Triad-S has two relays on the BKSLJ that can be programmed to perform certain functions. These functions are loud bell, external page control, RAN Start, and CO Line control. RELAY 1RELAY 2 *n% 131113I14 Baud Rate Assignments Programming Steps ‘\.1Press FLASH and dial [15]. The first button is lit and ready for programming Port #I. The following message displays: I PORTBAUD19600I Description The Triad-S System provides outputs such as SMDR or ICLID to the optional RS-232 connectors on the MISU.PORT #lPORT #2PORT #3 MISU 1MISU 2MODEM %+Eim*12+%13 *lzcIizlPort #I, #2, #3 Baud Rates Programming Steps 1Press the desired PORT # flexible button (FLASH 15, Buttons #l, #2,or #3) to determine the port to program. STARPLUS Triad-S System Programming Manualissue I- December 1998
:2-60 System Parameters Programming Access Codes 2Enter a l-digit number for the baud rate: [I] = 150 Baud [2] = 300 Baud [3] = 600 Baud [4] = 1200 Baud [5] = 2400 Baud [6] = 4800 Baud ~ [7] = 9600 Baud 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description Port #l: First RS-232C port on the optional MISU board. Port #2: Second RS-232 port on the optional MISU board. By default, Port #l (MISU RS-232C), Port #2 (MISU RS-232) and Port #3 (Modem) baud rates are set for 9600. Access Codes Programming Steps If the system is in the programming mode, continue using program codes. If starting to program here, enter the programming mode. 1Press FLASH and dial [20]. The following message displays: ACCESSCODES ENTER BUTTON NUMBER Description This section describes the procedures and steps necessary to program Access codes. DISA ACCESSADMINCODEPASSWORD +kn *a #mIEl #Fi---mIssue I- December 7998 STARPLUS Triad-S System Programming Manual
System Parameters Programming Access Codes 2-61 DISA Access Code .s3w Programming Steps Q’,..“.S.,z.;&?--.
2-62System Parameters Programming Access Codes Station Message Detail Recording (SMDR) Programming Steps 1Press FLASH and dial [21]. The following message displays: SDR TPE PNT 9;;; ;ORTNO LD 80 2To program SMDR features, use the flexible button(s) as defined in the following procedures. 3The ENABLE/DISABLE, TYPE, and PRINT features toggle on and off each time the button is pressed. The display updates with each toggle. 4After all entries are made, Press HOLD to save the entry. A confirmation tone is heard. Description The Triad-S System can provide SMDR output to the optional RS-232C connectors on the MISU. When SMDR is desired, the following system-wide parameters determine how SMDR information is reported.ENABLE /DISABLECALL TYPEPRINT FORMAT BAUD RATE #!2ixzl4#12 *13 s&n SMDR Enable / Disable Programming Steps 1Press the ENABLE/DISABLE flexible button (FLASH 21, button #I). This feature toggles on and off each time the button is pressed. The display updates with each toggle. LED ON = SMDR is enabled LED OFF = SMDR is disabled 2Press HOLD to save the entry. A confirmation tone is heard Issue I- December 1998STARPLUS Triad-S System Programming Manual
System Parameters Programming Access Codes2-63 Description A call accounting device can be installed allowing the system to track calls by outside line number, number t-:=. .a c--2.: :. :sdialed, time of day, date, station that placed or received the call, and duration of the call. By default, SMDR is.~~~ disabled. Long Distance / All Calls Programming Steps 1Press the CALL TYPE flexible button (FLASH 21, button #2) to determine the type of calls to record. This feature toggles on and off each time the button is pressed. The display updates with each toggle. LED ON = Long Distance is enabled LED OFF = All Calls is enabled 2Press HOLD to save the entry. A confirmation tone is heard. Description ;The system can be set to record all outgoing calls or only outgoing long distance calls. Long Distance calls are defined as beginning with a 1 or 0, or containing eight or more digits. Incoming calls are only recorded if TYPE is set for all calls. By default, the system records long distance (LD) calls only. Character Print Assignment Programming Steps IPress PRINT FORMAT flexible button (FLASH 21, button #3) to determine the print format of SMDR records. This feature toggles on and off each time the button is pressed. The display updates with each toggle. LED On = 80-Character is enabled LED Off =30-Character is enabled 2Press HOLD to save the entry. A confirmation tone is heard. cii252 Description The system can be programmed to print individual SMDR records in either a l-line 80-character format or a 3-line SO-character format. By default, the l-line SO-character format is selected, STARPLUS Triad-S System Programming ManualIssue I- December 1998
2-64System Parameters Programming Access Codes Baud Rate Display Programming Steps The SMDR Baud Rate is programmed using Flash 15, Baud Rate Assignments. FLASH 21, button #4 returns an error tone when pressed. The LCD displays the current baud rate based on which port is assigned to the SMDR Port number. Description The Triad-S System provides SMDR output to the standard RS-232C connector on the optional MISU. The baud rate is displayed as 150, 300,600, 1200, 2400,4800, or 9600 baud. SMDR Port Assignments Programming Steps 1Press the PORT flexible button (FLASH 21, button #5) to determine which port to use for SMDR information. 2Enter a l-digit number for the SMDR Port number: [I] = Port #l (MISU On-Board RS-232C) [2] = Port #2 (MISU On-Board RS-232C) 3The LCD displays the current baud rate based on which Port number is assigned to the SMDR Port number. 4Press HOLD to save the entry. A confirmation tone is heard and the display updates. Description PORT #l: Refers to the standard RS-232C connector on the optional MISU. PORT #2: Refers to the standard RS-232C connector on the optional MISU. By default, Port #l is used for SMDR. issue I- December 1998STARPLUS Triad-S System Programming Manual
System Parameters Programming Access Codes2-65 Weekly Night Mode Schedule Programming Steps 1Press FLASH and dial [22]. The following message displays: IDAY END START AUTOMON 0800 1700YESI Description The Triad-S System can be programmed so it is automatically placed into and out of night mode. A programmable weekly time schedule lets the system administrator preset the time the system goes into night mode, and the time night mode is removed on a daily basis, including weekend operation.AUTO IMANUALMONDAYTUESDAY WEDNESDAY sn *lIsci!a *ELziEl8IRITHURSDAYFRIDAY SATURDAYSUNDAY %+;: 116 St+-#lzicil Automatic / Manual Operation Programming Steps 1Press the AUTO/MANUAL flexible button (FLASH 22, button #I). This feature toggles on and off each time the button is pressed. The display updates with each toggle. LED On = Automatic Night Mode LED Off = Manual operation 2If no other changes must be made, press HOLD to save the entry. A confirmation tone is heard. Once enabled, this feature addresses the entire week. Description If the system is operated in the automatic night mode the attendant(s) can override the automatic mode by pressing the night key on the attendant(s) phone. The schedule does not go into effect until the attendant(s) STARPLUS Triad-S System Programming ManualIssue I- December 1998
2-66System Parameters Programming Access Codes press the night key again. When the system is placed into night mode, CO line ringing follows the night ringing assignments and stations are governed by their respective night COS. The default times for automatic night mode are: Monday through Friday OS:00 17:00(Daytime operation 8:00 am to 5:00 pm) Saturday and Sunday ##:## ##:##(24-hour night-mode operation) ttAn entry of 0O:OO 23:59 indicates 24 hours of day mode oAn entry of ##;## ##;## directs the system to ignore these days. Day of Week Programming Programming Steps The MONDAY flexible button (Button #2> LED is lit. To change days of the week: 1Press the appropriate DAY OF WEEK flexible button (FLASH 22, buttons 2-8). 2Enter the 8-digit entry to indicate the hour and minutes to end night mode. 3Press HOLD to save the entry. (Example: 07301830 [HOLD]) A confirmation tone is heard and the display updates. Directory Dialing Programming Steps To enter, change, erase or view entries in the Directory Dialing list: IPress FLASH and dial [23].The following message displays: IDIR LST AAA BIN / ICM:xxx nnnnnnnnnnnnnnnnnnnnnnnnnnnnIWhere: AAA = Directory list entry number (000-199) XXX = a station number, a system speed dial bin number, or Local Number/Name Translation table number nnn = programmed name (blank if none) To select a particular list entry: IPress Flexible button #20 for a directory list entry. 2Dial the 3-digit directory list entry number (000-199). Issue I- December 1998 STARPLUs Triad-S System Programming Manual
System Parameters Programming Access Codes2-67 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. To scroll through the list: 1Press the NEXT flexible button (FLASH 23, button #18) to scroll up (next entry) or Press the PREV flexible button (FLASH 23, button #19) to scroll backwards (previous entry). Description Directory Dialing enables station users obtain a directory of station users and have the system dial the extension currently displayed. The Triad-S system provides locations for up to 200 names (000-199). Directory dialing also lets users program a name with a speed dial bin for use in later locating a speed dial number. When prompted, the system displays the name associated with a speed dial number so when the desired name is shown, the user may then have the system dial the number. Directory dialing also lets users associate a name with an entry in the local number/name translation table. When prompted, the system displays the name associated with the table so when the desired name is shown, the user may then have the system dial the number. The Triad-S system provides locations for up to 200 names. The Directory Dialing list may be programmed and maintained at the first assigned attendant station in one of two ways. However, this admin routine lets the directory list be maintained by the system programmer locally (at Station 100) or remotely via modem access. STARPLUS Triad-S System Programming Manual Issue 7 - December 1998
2-68System Parameters Programming Access Codes %i #114 de115 #lIoxzilNEXT ENTRYPREV ENTRYNEW ENTRY #117*rscria %@mzil%; To enter the Intercom number or System Speed Dial bin to associate to the name: 1Press the BIN/KM flexible button (FLASH 23, button #l). 2Enter a 3-digit station intercom number, a 3-digit System Speed Dial number, or a 3-digit Local Number/name Translation Table number. 100-l 31 = Triad-S Extension Numbers 020-099 = System Speed Number 600-799 = Local Number/Name Table 3Press HOLD to save the entry. A confirmation tone is heard and the display updates. BIN/KM - Each entry in the directory dialing list must be associated to a system speed dial bin (for calling a destination outside of the system) or to an intercom station (for calling internal station including CO line transfers). To enter or change the current Name shown on the display: IPress the NAME flexible button (FLASH 23, button #2). 2Enter the name (up to 24-characters may be entered) by using keys on the dial pad as illustrated on the following page: Issue I- December 1998STARPLUS Triad-S System Programming Manual