    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Administrators Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1707
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    947 System Parameters Customer-Options 
    17
    Request Feature
    Allows the associated adjunct to request features such as change work modes, 
    login, logout, sac, and fwd.
    Set Value
    Allows the adjunct to request status changes for Message Waiting lamps (that is, 
    control of the on/off state of the lamps) and billing changes for 900-type call 
    within Flexible Billing.
    NOTE:
    To request status changes to flexible billing, set Flexible Billing to y on page 
    1 of the System-Parameters Customer-Options screen.
    For CallVisor ASAI adjuncts, you can assign an alarm severity option to each of 
    the following categories via the 
    set options command:
    nMajor on-board ASAI adjunct alarms
    nMajor off-board ASAI adjunct alarms
    nMinor on-board ASAI adjunct alarms
    nMinor off-board ASAI adjunct alarms
    See DEFINITY Enterprise Communications Server Maintenance for R7r, 
    DEFINITY Enterprise Communications Server Maintenance for R7si, or 
    DEFINITY Enterprise Communications Server Maintenance for R7csi for 
    information on using the 
    set options command.
    For international Outbound Call Management applications, you may need to 
    complete the System Parameters OCM Call Classification screen.
    CallVisor ASAI Optional Features
    In addition to ASAI capability groups on the System-Parameters 
    Customer-Options screen there are ASAI optional features, which are described 
    below. Except for Switch Classified Outbound Calls, all options default to 
    n.
    Answering Machine Detection
    Used by the adjunct for predictive Outbound Call Management. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    948 System Parameters OCM Call Classification 
    17
    Selective Listening
    Consists of two capabilities, Third Party Listen Disconnect and Third Party Listen 
    Reconnect. Listen Disconnect allows the adjunct to disconnect selected listening 
    paths on an active call. Listen Reconnect allows the adjunct to reconnect 
    disconnected listening paths.
    Switch Classified Outbound Calls
    When you enable the CallVisor ASAI option(s), the following capabilities are 
    automatically enabled, regardless of the groups selected: Value Query (includes 
    Response Continued Capability), Abort, Heart Beat, Restart Procedure, 
    Suspend/Resume Alarm.
    NOTE:
    You must logoff and login to effect the permission changes.
    System Parameters OCM 
    Call Classification
    This screen enters the tone characteristics for your country for Outbound Call 
    Management (OCM) applications. It is not required for United States OCM 
    applications. If you cannot access this screen, contact your Lucent Technologies 
    representative.
    Field descriptions for page 1
    Screen 198. System Parameters OCM Call Classification screenValid entries Usage
    y
      Enable predictive dialing in the switch.
    nDisable predictive dialing in the switch.
    Page 1 of 2
     SYSTEM PARAMETERS OCM CALL CLASSIFICATION
    TONE DETECTION PARAMETERS
    Global Classifier Adjustment (dB): ___
    USA Default Algorithm? _n
    _
    USA SIT Algorithm? ___ 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    949 System Parameters OCM Call Classification 
    17
    Global Classifier Adjustment (dB)
    Enter a number to specify the dB loss adjustment.
    USA Default Algorithm
    USA SIT Algorithm
    Field descriptions for page 2
    Screen 199. System Parameters OCM Call Classification screenValid entries Usage
    0
     to 15 0 is the least and 15 the most adjustment.
    Valid entries Usage
    y/n
    To use the default United States tone detection, set this field to 
    y. If you enter n, the US Special Information Tones (SIT) 
    Algorithm field appears.
    Valid entries Usage
    y
    To use the United States (SIT) tone characteristics for SIT tone 
    detection.
    nThe system treats tones with the administered tone name 
    “intercept” as if they were SIT VACANT, and treats tones with 
    the administered tone name “information” as if they were SIT 
    UNKNOWN.
    Page 2 of 9
    SYSTEM PARAMETERS OCM CALL CLASSIFICATION
    Tone Name Instance  Tone Cadence Duration Duration
    Continuous Step Minimum Maximum
    _________ _____ ___ 1. on _____ _____
    2. off _____ _____
    3. on _____ _____
    4. off _____ _____
    5. on _____ _____
    6. off _____ _____
    7. on _____ _____
    8. off _____ _____ 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    950 System Parameters OCM Call Classification 
    17
    Tone Name
    Instance
    Enter the instance number of the tone. If the system identifies a tone that matches 
    the characteristics defined on more than one page of this screen the system applies 
    the tone definition from the earlier page.
    Tone Continuous
    Cadence Step
    A display-only field identifying the number of each tone cadence step and 
    indicating whether the tone is on or off during this cadence step.
    Duration Minimum
    Specifies the lower limit in milliseconds (msec) of the tone duration.
    Valid entries Usage
    busy
    information
    intercept
    reorder
    ringback
    Enter the name of the tone that you are adding or 
    modifying. This field is required for tone definition 
    outside of the U.S. and Canada.
    Valid entries Usage
    1
    –8The number distinguishes tones that have the same use but 
    more than one definition of silence and tone-on 
    characteristics. 
    Valid entries Usage
    y
    Indicates a continuous tone. If you enter y, you cannot enter 
    data in the Duration Minimum or Duration Maximum fields.
    nIndicates a non-continuous tone.
    Valid entries Usage
    75
     – 6375Enter in increments of 25 msec. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    951 Telecommuting Access 
    17
    Duration Maximum
    Specifies the upper limit in milliseconds of the tone duration.
    NOTE:
    On the Feature-Related System Parameters screen, set the Off-Premises 
    Tone Detect Timeout Interval field to its maximum value.
    Telecommuting Access 
    This screen allows the System Administrator to administer the extension which 
    allows remote users to use the feature.
    Field descriptions for page 1
    Screen 200. Telecommuting Access 
    Telecommuting Access Extension
    This only allows remote access to the Telecommuting Access feature.
    Related Topics
    Refer to ‘‘
    Configuring DEFINITY ECS for telecommuting’’ on page 285 for 
    information about setting up telecommuting.
    Te n a n t  
    This screen defines tenants to the system. If your switch uses tenant partitioning, 
    you can 
    Valid entries Usage
    75
     – 6375Enter in increments of 25 msec.
    Valid entries Usage
    Unassigned 
    extensionEnter an extension that conforms to your system’s dial plan and 
    is not assigned to any other system object. 
    add telecommuting-access
     TELECOMMUTING ACCESS
    Telecommuting Access Extension: ____ 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    952 Tenant 
    17
    See ‘‘Tenant Partitioning’’ on page 1536 for more information. 
    Field descriptions for page 1
    Screen 201. Tenant 
    Tenant
    This is a display only field. It contains the tenant number that you entered on the 
    command line.
    Tenant Description
    Attendant Group
    This required information relates a tenant to an attendant group.
    NOTE:
    The default for the system is that all attendant groups exist. However, the 
    attendant group will be empty if no consoles are assigned to it.
    Valid entries Usage
    40 alpha-numeric characters 
    or blank You may leave the description field blank, but 
    future administration will be easier if you provide 
    descriptive information.
    Valid entries Usage
    1
    –16. See DEFINITY ECS System Description, for your system’s 
    range of allowable attendant group numbers.
    change tenant 18 
                               Tenant 18
    Tenant Description: ________________________________________
    Attendant Group: 1
    Ext Alert Port (TAAS): _______ Ext Alert (TAAS) Extension: ____
    Night Destination: _____ 
     
    Music Source: 1 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    953 Tenant 
    17
    Ext Alert Port (TAAS)
    Ext Alert (TAAS) Extension
    This field appears only if you entered an 
    X in Ext Alert Port (TAAS). 
    Night Destination
    Music Source
    Valid entries Usage
    A valid port 
    address or XEnter 7 character port number. Enter Trunk Answer Any Station 
    (TAAS) alert port information, if any. The port type and the 
    object type must be consistent, and the port can be assigned to 
    only one tenant.
    Valid entries Usage
    A valid 
    extensionIf you entered an X in Ext Alert Port (TAAS), you must enter 
    extension information in this field.
    Valid entries Usage
    A valid 
    extension Enter the night service station extension, if you want night 
    service for this tenant.
    Valid entries Usage
    1
    –20  Enter the music/tone source for this partition. These sources 
    are defined on the Music Sources
     screen. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    954 Terminal Parameters 
    17
    Field descriptions for page 2
    Screen 202. Tenant 
    Tenant
    This is a display only field. It contains the tenant number that you entered on the 
    command line.
    Calling permissions
    The system default allows each tenant to call only itself and Tenant 1. If you want 
    to change that, you can do that on this screen.
    Terminal Parameters 
    This screen administers system-level parameters and audio levels for the 603 
    CALLMASTER telephones and the 6400-series, 8403, 8405B, 8405B+, 8405D, 
    8405D+, 8410B, 8410D, 8411B, 8411D, and 8434D phones.
    NOTE:
    Only authorized Lucent Technologies personnel can administer this screen.
    Valid entries Usage
    y/n
    Enter y to establish calling permission between the tenant 
    number that you entered on the command line and any other 
    tenant.
    change tenant 18
                                       Tenant 18
    CALLING PERMISSION (Enter y to grant permission to call specified Tenant)
     1? y    11? n    21? n    31? n    41? n    51? n    61? n    71? n    81? n    91? n
     2? n    12? n    22? n    32? n    42? n    52? n    62? n    72? n    82? n    92? n
     3? n    13? n    23? n    33? n    43? n    53? n    63? n    73? n    83? n    93? n
     4? n    14? n    24? n    34? n    44? n    54? n    64? n    74? n    84? n    94? n
     5? n    15? n    25? n    35? n    45? n    55? n    65? n    75? n    85? n    95? n
     6? n    16? n    26? n    36? n    46? n    56? n    66? n    76? n    86? n    96? n
     7? n    17? n    27? n    37? n    47? n    57? n    67? n    77? n    87? n    97? n
     8? n    18? y    28? n    38? n    48? n    58? n    68? n    78? n    88? n    98? n
     9? n    19? n    29? n    39? n    49? n    59? n    69? n    79? n    89? n    99? n
    10? n    20? n    30? n    40? n    50? n    60? n    70? n    80? n    90? n   100? n 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    955 Terminal Parameters 
    17
    Screen 203. 8400-Series Terminal Parameters 
    * This field appears only if Customize Parameters is y.
    Screen 204. 603/302B1 Terminal Parameters 
    change terminal-parameters 8400     Page 1 of 1
                                8400-TYPE TERMINAL PARAMETERS
       
              Default Parameter Set: __         Customize Parameters? _
       
       OPTIONS*
                       Display Mode: _*                DLI Voltage Level: _________*
           Handset Expander Enabled? _*
       
       PRIMARY LEVELS*
                Voice Transmit (dB): _____*          Voice Sidetone (dB): _____*
                 Voice Receive (dB): _____*     Touch Tone Sidetone (dB): _____*
           Touch Tone Transmit (dB): _____*
       
       ADJUNCT LEVELS*+
                Voice Transmit (dB): _____*          Voice Receive (dB): _____*
                Voice Sidetone (dB): _____*    Touch Tone Sidetone (dB): _____*
       BUILT-IN SPEAKER LEVELS
                Voice Transmit (dB): _____*          Voice Receive (dB): _____*
                                               Touch Tone Sidetone (dB): _____*
       8403 BUILT-IN SPEAKER LEVELS
                 Voice Receive (dB): _____*    Touch Tone Sidetone (dB): _____*
    change terminal-parameters 302B1/603/606 Page 1 of 1
                               302B1/603/606 TERMINAL PARAMETERS
       
              Default Parameter Set: __             Customize Parameters? _
       
       OPTIONS*
                       Display Mode: _*                DLI Voltage Level: _________*
     
       
       PRIMARY LEVELS*
                Voice Transmit (dB): _____*          Voice Sidetone (dB): _____*
                 Voice Receive (dB): _____*     Touch Tone Sidetone (dB): _____*
           Touch Tone Transmit (dB): _____*
       
      
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    956 Terminal Parameters 
    17
    Screen 205. 6400 Type Terminal Parameters 
    Default Parameter Set
    Determines which default set of telephone options and levels will be used. This 
    field corresponds to the country codes. Refer to ‘‘
    System Parameters 
    Country-Options’’ on page 918 for the country code listing.
    Customize Parameters
    Indicates whether the administrator wishes to change one or more of the default 
    parameters.
    Valid entries Usage
    y
    If this field is y (yes), the OPTION and LEVEL fields appear 
    and all fields can be edited.
    nIf this field is n (no), the system uses all default parameters 
    associated with the Default Parameter Set field and all fields 
    are display-only.
    change terminal-parameters 640/607A1 Page 1 of 1
         6400-TYPE TERMINAL PARAMETERS
          Default Parameter Set: 1 Customize Parameters? y
       
    OPTIONS
         Display Mode:
         Handset Expander Enabled?
         Volume:
    PRIMARY LEVELS
    Voice Transmit (dB):     Voice Sidetone (dB):
    Voice Receive (dB):     Touch Tone Sidetone (dB):
    Touch Tone Transmit (dB):
    BUILT-IN SPEAKER LEVELS
    Voice Transmit (dB):      Voice Receive (dB):
        Touch Tone Sidetone (dB):
    6402 BUILT-IN SPEAKER LEVELS
    Voice Receive (dB):     Touch Tone Sidetone (dB): 
    						