    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Administrators Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1707
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    647 Feature-Related System Parameters 
    17
    Controlled Station-to-Station Restriction
    Enter the type of intercept treatment the caller receives when the call is placed to a 
    restricted telephone.
    Authorization Code Parameters
    Authorization Codes Enabled
    This field cannot be administered if Authorization Codes is not enabled on the 
    System-Parameters Customer-Options screen.
    !SECURITY ALERT:
    To maintain system security, Lucent recommends that Authorization Codes 
    be used.
    Authorization Code Length
    This field only appears and must be completed if Authorization Codes Enabled is 
    y. This is the number of digits that must be assigned to the Authorization Code 
    (AC) field on the Authorization Code screen.
    Valid entries Usage
    announcement
    If announcement is entered, an associated extension number 
    field displays. Enter the extension of the restricted telephone 
    in the field.
    attendantIntercepted calls are redirected to the attendant.
    extension (may 
    not be a VDN 
    extension)If extension is entered, an associated extension number field 
    displays. Enter the extension of the restricted telephone in 
    the field.
    tone  Intercepted calls receive intercept (siren) tone.
    Valid entries Usage
    y/n
     Enter y to enable Authorization Codes on a systemwide basis.  
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    648 Feature-Related System Parameters 
    17
    !SECURITY ALERT:
    You enhance your system’s security by using the maximum length for your 
    authorization code.
    Authorization Code Cancellation Symbol
    Enter the symbol a caller must dial to cancel the 10-second wait period during 
    which the user can enter an authorization code. This field only appears when 
    Authorization Code is 
    y.
    Attendant Time Out Flag
    If this field is not enabled, the caller receives Intercept tone. This flag affects only 
    remote users or incoming calls over trunks requiring an authorization code. This 
    field only appears if Authorization Codes Enabled is 
    y.
    Valid entries Usage
    4–13 digits Enter a number that defines the number of digits (length) in the 
    Authorization Code field. 
    Valid entries Usage
    #
    Enter the cancellation code # if the main and tandem switches 
    are both the same type of switch.
    1Enter the cancellation code 1 if an Lucent Technologies 
    System 85 or DIMENSION PBX switch is part of the 
    complex/network.
    Valid entries Usage
    y/n
    Enter y if a call is to be routed to the attendant if the caller does 
    not dial an authorization code within 10 seconds or dials an 
    invalid authorization code.  
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    649 Feature-Related System Parameters 
    17
    Display Authorization Code
    This field applies only to DCP, not to BRI or hybrid sets.
    !SECURITY ALERT:
    To enhance your system’s security, set Display Authorization Code to 
    n.
    Controlled Toll Restriction Replaces
    This field activates the Controlled Toll Restriction feature.
    Controlled Toll Restriction Intercept Treatment
    This field applies an intercept treatment to a toll call during the call processing.
    Valid entries Usage
    y 
     Enter y to allow authorization code digits to display on the set 
    during the dialing.
    nEnter n if these digits should not display. 
    Valid entries Usage
    outward
    station-station
    none
    The value that you choose for this field will be replaced by 
    controlled toll restriction. In other words, if you choose 
    station-station, you will not be able to use station-station 
    restrictions unless you reset this field. 
    Valid entries Usage
    announcement
    A sub-field appears to the right if announcement is used. If 
    the entry is 
    announcement, enter the assigned 
    announcement extension. 
    attendantIntercepted calls are redirected to the attendant. 
    extensionA sub-field appears to the right if extension is used. If the 
    entry is 
    extension, enter the extension assigned to station or 
    individual attendant.
    tone  Intercepted calls receive intercept (siren) tone. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    650 Feature-Related System Parameters 
    17
    Field descriptions for page 4
    Screen 88. Feature-Related System Parameters screen
    System Printer Parameters
    The system printer is the printer dedicated to support scheduled reports.
    System Printer Extension
    NOTE:
    The eia option is not available for G3r.
    Lines Per Page
    Valid entries Usage
    Data module extension 
    number.Associated with the System printer 
    eiaIf the DCE jack is used to interface the printer.
    Valid entries Usage
    24
     – 132  Enter the number of lines per page required for the report.
    change system-parameters features   Page 4 of 10
                              FEATURE-RELATED SYSTEM PARAMETERS
    SYSTEM PRINTER PARAMETERS
                 System Printer Extension: ____                 Lines Per Page: 60
                      EIA Device Bit Rate: 9600
    SYSTEM-WIDE PARAMETERS
                              Switch Name: ________________
    MALICIOUS CALL TRACE PARAMETERS
                   Apply MCT Warning Tone? n     MCT Voice Recorder Trunk Group: ___
    SEND ALL CALLS OPTIONS
    Send All Calls Applies to: station
    Auto Inspect on Send All Calls? n
    UNIVERSAL CALL ID
    Create Universal Call ID (UCID)? n UCID Network Node ID: ___ 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    651 Feature-Related System Parameters 
    17
    EIA Device Bit Rate
    This field is not displayed for G3r.
    System-Wide Parameters:
    Switch Name
    Malicious Call Trace Parameters:
    Apply MCT Warning Tone
    MCT Voice Recorder Trunk Group
    Assign the trunk group for MCT voice recorders.
    Valid entries Usage
    1200
    2400
    4800
    9600
    Enter the required printer speed setting.
    Valid entries Usage
    Any keyboard 
    character.Enter alpha-numeric characters for identification.
    Valid entries Usage
    y/n
    Enter y to provide an audible tone to the controlling station 
    when an MCT recorder is actively recording a malicious call.
    Valid entries Usage
    1
     to 99 group number 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    652 Feature-Related System Parameters 
    17
    Send All Calls Options:
    Send All Calls Applies to
    Auto Inspect on Send All Calls
    Universal Call ID (UCID):
    Create Universal Call ID (UCID)
    UCID Network Node ID 
    Enter a number unique to the switch in a network of switches.
    Valid entries Usage
    station
      If set to station, any call to that station, regardless of the 
    number dialed, causes calls to that station’s own extension to 
    be sent immediately to Coverage, or causes calls to different 
    extensions assigned to the station as bridged appearances to 
    become Ring-Ping notification if Redirect Notification field is 
    y.
    extensionWhen set to extension, only the calls sent to that extension are 
    placed to coverage.
    Valid entries Usage
    y
    If set to y, allows you to be presented automatically with 
    Calling Party information for calls which are silently alerting 
    their station because of the Send-All-Calls feature.
    n  If set to n, you are not guaranteed a Calling Party display for 
    calls sent directly to Coverage by the Send-All-Calls feature.
    Valid entries Usage
    y
    If set to y, DEFINITY will generate UCID for each call when 
    necessary.
    n  If set to n, the DEFINITY will not generate a UCID for any call.
    Valid entries Usage
    1
     to 32767  This number is an important part of the UCID tag and must be 
    unique to the switch. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    653 Feature-Related System Parameters 
    17
    Field descriptions for page 5
    Screen 89. Feature-Related System Parameters screen
    Public Network Trunks on Conference Call
    Indicates the number of public network trunks allowed on a conference call.
    Auto Start
    If this field is enabled, the 
    START buttons on all attendant consoles are disabled.
    Conference Parties with Public Network Trunks
    Specifies the maximum number of parties allowed in a conference call involving a 
    public network subscriber. If the value of the Public Network Trunks on 
    Conference Call field is 
    0, this field will not appear on the screen.
    Valid entries Usage
    0
     to 5  If this field is 0, the Conference Parties with Public Network 
    Trunks field will not appear on the screen.
    Valid entries Usage
    y/n
     Enter y to enable the Automatic Start feature.
    Valid entries Usage
    3
     to 6 
    change system-parameters features  Page 5 of 10
                              FEATURE-RELATED SYSTEM PARAMETERS
     
        Public Network Trunks on Conference Call: 5     Auto Start? n
       Conference Parties with Public Network Trunks: 6     Auto Hold? n
    Conference Parties without Public Network Trunks: 6     Attendant Tone? y
             Night Service Disconnect Timer (seconds): 180    Bridging Tone? n
       Short Interdigit Timer (seconds): 3    Conference Tone? n
                  Unanswered DID Call Timer (seconds): ____    Intrusion Tone? n
                  Line Intercept Tone Timer (seconds): 30    Special Dial Tone? n
    Long Hold Recall Timer (seconds): 160
                          Reset Shift Timer (seconds): 0
    Station Call Transfer Recall Timer (seconds): 0                      
                                   DID Busy Treatment: tone
    Allow AAR/ARS Access from DID/DIOD? _
    Allow ANI Restriction on AAR/ARS? _ Transfer Upon Hang-Up? n  
               Abort Conference Upon Hang-Up? n Abort Transfer? n
    7405ND Numeric Terminal Display? n            7434ND? n
    DISTINCTIVE AUDIBLE ALERTING
    Internal: 1   External: 2   Priority: 3
    Attendant originated Calls:_ ________
    DTMF Tone Feedback Signal to VRU - Connection: _ Disconnection: _ 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    654 Feature-Related System Parameters 
    17
    Auto Hold
    Conference Parties without Public Network 
    Trunks
    Enter a number to specify the maximum number of parties allowed in a 
    conference call involving no public network trunks.
    Attendant Tone
    Night Service Disconnect Timer (seconds)
    Enter a number or blank to indicate how long a trunk call can be unanswered 
    during night service before being disconnected. The trunk must not have 
    Disconnect Supervision for this timer to apply.
    Bridging Tone
    Short Interdigit Timer (seconds)
    Enter a number to limit the time that digit analysis will wait for the next digit 
    when it has predicted that all the digits have already been collected.
    Valid entries Usage
    y/n
     Enter y to enable the Automatic Hold feature on a 
    system-wide basis.
    Valid entries Usage
    3
     to 6
    Valid entries Usage
    y/n
     Enter y to provide call progress tones to the attendants.
    Valid entries Usage
    10
     to 1024 
    Valid entries Usage
    y/n
     Enter y to apply a bridging tone when calls are bridged on 
    primary extensions.
    Valid entries Usage
    3
     to 9 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    655 Feature-Related System Parameters 
    17
    Conference Tone
    NOTE:
    Bridging and Conference Tones are not supported by all countries. If these 
    tones are enabled for countries other than Italy, Belgium, United Kingdom, 
    or Australia, the tones will be equivalent to no tone (silence) unless the tone 
    is independently administered or customized on the System-Parameters 
    Country Options screen. 
    Unanswered DID Call Timer (seconds)
    Enter number or blank to limit how long a DID call can remain unanswered before 
    routing to the DID/TIE/ISDN Intercept Treatment feature. This timer interacts 
    with the nonadministrable 50 second Wait for Answer Supervision Timer 
    (WAST). The WAST timer overrides this field. Thus if this field is set to a value 
    equal to or greater than 50 seconds, the caller receives intercept tone instead of the 
    normal attendant or announcement treatment that is given when the Unanswered 
    DID Call Timer expires before the WAST. If the Unanswered DID Call Timer 
    expires while the DID call is being processed by call vectoring, the timer is 
    ignored. See Wait Answer Supervision Timer
     in this section.
    Intrusion Tone
    Line Intercept Tone Timer (seconds)
    Enter a number to specify how long an analog station user can wait after hearing 
    warning tone without going on hook, before the station is placed in the lockout 
    state.
    Valid entries Usage
    y/n
     Enter y to provide conference tone as long as three or more 
    calls are in a conference call.
    Valid entries Usage
    A number between 10and 1024  
    blank A value of blank disables this timer.
    Valid entries Usage
    y/n
    Enter y to apply an intrusion tone (executive override) when an 
    attendant intrudes on the call.
    Valid entries Usage
    2
    –60 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    656 Feature-Related System Parameters 
    17
    Special Dial Tone
    Special dial tone notifies an analog-phone user if certain features are still active 
    when the user goes off-hook. These features include:
    nCall Forwarding
    nSend All Calls
    nDo Not Disturb
    Refer to the DEFINITY ECS Application Notes for Type Approval for more 
    information.
    Long Hold Recall Timer (seconds)
    You can administer the system to remind a user that a call has been on hold for too 
    long. 
    Reset Shift Timer (seconds)
    Used only for station-to-station calls or private network calls using ISDN trunks.
    Station Call Transfer Recall Timer
    Allows a user-transferred call (station-to-station, a trunk call, or a DCS call) to 
    re-terminate with priority ringing back to the station user who initiates the transfer 
    operation if the transfer-to party does not answer the call within the administered 
    Station Call Transfer Recall timer.
    Valid entries Usage
    y/n
     Enter y to use the Special Dial Tone. You must have a TN2182 
    circuit pack. 
    Valid entries Usage
    0
     - 999 Enter a number between 0 and 999; 0 deactivates the timer. 
    This value is the number of seconds a call can be on hold 
    before the system re-alerts the user to remind them of the call.
    Valid entries Usage
    0
     - 255Specifies the number of seconds that reset shift dial tone is 
    audible before busy tone is heard. Enter 
    0 to disable this 
    feature.
    Valid entries Usage
    0 
    - 999Enter the time in seconds before a call redirects back to the 
    station user who initiated the transfer operation. Enter 
    0 to 
    disable this feature. 
    						
    All Lucent Technologies manuals Comments (0)