    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Administrators Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1707
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    877 Security-Related System Parameters 
    17
    Referral Destination
    The referral destination receives the referral call when a security violation occurs. 
    The referral destination telephone must have a display, unless the you assign an 
    Announcement Extension. 
    Login (Barrier Code, Authorization Code 
    Security Code) Threshold
    The value assigned to this field, in conjunction with Time Interval, determines 
    whether a security violation has occurred. For example, if this field is 5, and time 
    interval is 0:03, then five invalid access attempts within three minutes constitutes a 
    security violation. 
    Time Interval
    The value of this field, in conjunction with Threshold, determines whether a 
    security violation has occurred.
    Valid entries Usage
    An extension Enter the extension of the telephone, attendant console, or 
    vector directory number (VDN) that you want to receive the 
    referral call for each type of violation. This can be the same 
    extension for all type of violations.
    If you use a VDN, you must complete the Announcement 
    Extension field. You can also use Call Vectoring Time-of-Day 
    routing to route the referral call to different destinations based 
    on the time of day or the day of the week. 
    Valid entries Usage
    1–99, 1–255
     for 
    Station Security 
    codeEnter the number of access attempts that are permitted before a 
    referral call is made. In general, it is good to keep this number 
    low. If you are doing testing and do not want to generate 
    alarms, you might change this threshold temporarily.
    Valid entries Usage
    0:01
     to 7:59The range for the time interval is one minute to eight hours. 
    Entered in the screen “x:xx.” For example, if you want the time 
    interval to be one minute, you enter 0:01. If you want the time 
    interval to be seven and one-half hours, you enter 7:30.  
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    878 Security-Related System Parameters 
    17
    Announcement Extension
    If you enter a value in this field, the switch calls the referral destination, then plays 
    this announcement upon answer.
    SVN Remote Access Violation Notification 
    Enabled
    Use these fields to establish parameters for remote access security violations. A 
    remote access violation occurs if a user enters incorrect barrier codes. You cannot 
    set the system to disable remote access following a security violation unless you 
    have turned this on here. 
    SVN Authorization Code Violation Notification 
    Enabled
    Field descriptions for page 2
    Screen 182. Security-Related System Parameters for G3r Valid entries Usage
    Valid extension The announcement extension where SVN 
    violation announcement resides. 
    change system-parameters security     Page 2 of 2
        SECURITY-RELATED SYSTEM PARAMETERS
    SECURITY VIOLATION NOTIFICATION PARAMETERS
    SVN Station Security Code Violation Notification Enabled? y
    Originating Extension: _____  Referral Destination: _____
    Station Security Code Threshold: 10 Time Interval: 0:03
    Announcement Extension: _____
    STATION SECURITY CODE VERIFICATION PARAMETERS
    Minimum Station Security Code Length: 4
    Security Code for Terminal Self Administration Required? y
    ACCESS SECURITY GATEWAY PARAMETERS
    SYSAM-LCL? n SYSAM-RMT? n
    MAINT? n       SYS-PORT? n
      Translation-ID Number Mismatch Interval (days): _ 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    879 Security-Related System Parameters 
    17
    Screen 183. Security-Related System Parameters for G3si and G3csi 
    SVN Station Security Code Violation 
    Notification Enabled
    Station Security codes are used to validate logins to a particular extension (for 
    example, a home agent using an extender, or two part-time workers using the same 
    telephone, but different extensions, through personal station access.) Enter 
    y here 
    to establish parameters for this.
    Minimum Station Security Code Length
    This determines the minimum required length of the Station Security Codes that 
    you enter on the Station screen.
    Security Code for Terminal Self Administration 
    Required
    Valid entries Usage
    3–8
    Longer codes are more secure. If station security codes are 
    used for external access to telecommuting features, the 
    minimum length should be 7 or 8.
    Valid entries Usage
    y/n
    Enter y to indicate that a security code is required.
    change system-parameters security Page 2 of 2
        SECURITY-RELATED SYSTEM PARAMETERS
    SECURITY VIOLATION NOTIFICATION PARAMETERS
    SVN Station Security Code Violation Notification Enabled? y
    Originating Extension: _____  Referral Destination: _____
    Station Security Code Threshold: 10 Time Interval: 0:03
    Announcement Extension: _____
    STATION SECURITY CODE VERIFICATION PARAMETERS
                       Minimum Station Security Code Length: 4
    Security Code for Terminal Self Administration Required? y
    ACCESS SECURITY GATEWAY PARAMETERS
        MGR1? n INADS? n
     EPN? n      NET? n 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    880 Security-Related System Parameters 
    17
    Access Security Gateway Parameters
    These eight fields appear only if the Access Security Gateway (ASG) field on the 
    System-Parameters Customer-Options screen is 
    y. 
    The following 4 fields display only for the G3r version:
    SYSAM-LCL 
    A direct cable connection to the SYSAM-LCL G3-MT (local system 
    administrator’s terminal) port on the System Access and Maintenance circuit pack 
    on the active G3r processor carrier. For more information on the circuit pack, refer 
    to the DEFINITY ECS System Description.
    SYSAM-RMT 
    A dialed-in (or out) connection to the SYSAM-RMT port on the System Access 
    and Maintenance circuit pack in the active G3r processor carrier. For more 
    information on the circuit pack, refer to the DEFINITY ECS System Description. 
    MAINT 
    A direct connection to the EPN maintenance circuit pack RS-232 interface.
    SYS-PORT 
    A dialed-in (or out) connection to the System Access Port.
    Valid entries Usage
    y/n
      Any entry attempt through this port receives a challenge 
    response.
    Valid entries Usage
    y/n
    Any entry attempt through this port receives a challenge 
    response.
    Valid entries Usage
    y/n
      Any entry attempt through this port receives a challenge 
    response.
    Valid entries Usage
    y/n
      Any entry attempt through this port receives a challenge 
    response. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    881 Security-Related System Parameters 
    17
    The following fields display only for the G3si and G3csi versions:
    MGR1 
    The direct connect system administration and maintenance access interface 
    located on the processor circuit pack. For more information on the circuit pack, 
    refer to the DEFINITY ECS System Description.
    INADS 
    A direct cable connection to the Initialization and Administration System used to 
    remotely initialize and administer DEFINITY ECS.
    EPN 
    A direct connection to the Expansion Port Network.
    NET 
    A dialed-in (or out) connection to the Network Controller circuit pack. For more 
    information on the circuit pack, refer to the DEFINITY ECS System Description.
    Translation-ID Number Mismatch Interval (days)
    A display-only field for all logins except init; only init logins can change this 
    field. This field specifies the interval (in days) that the system allows a mismatch 
    between the translation ID stored in the Processor circuit pack(s) and on the flash 
    Valid entries Usage
    y/n
      Any entry attempt through this port receives a challenge 
    response.
    Valid entries Usage
    y/n
    Any entry attempt through this port receives a challenge 
    response.
    Valid entries Usage
    y/n
    Any entry attempt through this port receives a challenge 
    response.
    Valid entries Usage
    y/n
    Any entry attempt through this port receives a challenge 
    response. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    882 Site Data 
    17
    card. Following expiration of this interval, the ability to execute system 
    administration commands that modify translation data is denied for all logins, 
    except for init.
    Site Data
    Use this screen to enter information about buildings, floors and telephone set 
    colors. You must supply values on this screen before you can enter information in 
    the Site Data section of the Station screen.
    Field descriptions for pages 1, 2 and 3
    These pages are available for you to enter descriptive information about the 
    buildings, floors and phone set colors. You may enter any valid keyboard 
    character. If you want to indicate that a particular floor is in a particular building, 
    you must include this in the floor entry, for example, B301-Fl4.
    Station
    This section provides descriptions of all of the fields that may appear on Station 
    screens. Some of the fields are used for specific phone types; others are used for 
    all phone types. To make it easier to find a specific field, they are listed in 
    alphabetical order by field name.
    Valid entries Usage
    1-90
    Enter a number to indicate the number of days the system 
    allows access to system administration commands.
    change site-data
    SITE DATA USER DEFINITION
    VALID BUILDING FIELDS 
    _________ _________ _________ _________ _________
    _________ _________ _________ _________ _________
    _________ _________ _________ _________ _________
    _________ _________ _________ _________ _________
    _________ _________ _________ _________ _________ 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    883 Station 
    17
    Screen 184. Station
    Screen 185. Station 
    add station 1014 Page 1 of X
                                              STATION
    Extension: 1014                                Lock Messages? n       BCC: 0
    Type: 6408D+                         Security Code: ______   TN: 1
    Port: _____ Coverage Path 1: ___     COR: 1
        Name: __________________________  Coverage Path 2: ___     COS: 1
                                                 Hunt-to-Station: ____
    STATION OPTIONS
                  Loss Group: _ Personalized Ringing Pattern: 1
    Data Module? n   Message Lamp Ext: 1014
    Speakerphone: 2-way  Mute button enabled? y
    Display Language? English
                                                            Media Complex Ext: 
                                                                 IP Softphone? n
    add station 1014 Page 2 of X
    STATION
    FEATURE OPTIONS
    LWC Reception? msa-spe  Auto Select Any Idle Appearance? n
             LWC Activation? y  Coverage Msg Retrieval? y
    LWC Log External Calls? n Auto Answer: none
        CDR Privacy? n    Data Restriction? n
      Redirect Notification? y   Idle Appearance Preference? n
    Per Button Ring Control? n
    Bridged Call Alerting? n       Restrict Last Appearance? y
    Active Station Ringing: single
            H.320 Conversion? n Per Station CPN - Send Calling Number? _
    Service Link Mode: as-needed Special Character for Restricted Number? n
    Multimedia Mode: basic
    MWI Served User Type: ______   Display Client Redirection? n
    AUDIX Name: Select Last Used Appearance? n
    Messaging Server Name: ______ Coverage After Forwarding? _
    Recall Rotary Digit? n  Multimedia Early Answer? n 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    884 Station 
    17
    Screen 186. Station 
    The standard station fields are organized alphabetically for easy access.
    1-Step Clearing
    Abbreviated Dialing List1, List2, List3
    You can assign up to 3 abbreviated dialing lists to each phone.
    Valid entries Usage
    y/n
    If set to y, the call terminates again at the WCBRI terminal 
    when the user drops from the call.
    Valid entries Usage
    enhanced
    Allows the phone user to access the enhanced system 
    abbreviated dialing list.
    groupAllows the phone user to access the specified group 
    abbreviated dialing list. If you enter 
    group, you also must enter 
    a group number.
    personalAllows the phone user to access and program their personal 
    abbreviated dialing list. If you enter 
    personal, you also must 
    enter a personal list number.
    systemAllows the phone user to access the system abbreviated dialing 
    list.
    add station 1014 Page 3 of X
    STATION
         SITE DATA
              Room: _______                                      Headset? n
              Jack: ___                                          Speaker? n
             Cable: ___                                         Mounting: d
             Floor: _______                                  Cord Length: 0_
          Building: _______                                    Set Color: _____
    ABBREVIATED DIALING
         List1: ________           List2: _________          List3: _________
    BUTTON ASSIGNMENTS
     1: call-appr  5: ________
     2: call-appr  6: ________
     3: call-appr  7: ________
    4: ________ 8: ________ 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    885 Station 
    17
    Active Station Ringing
    Defines how call rings to the phone when it is off-hook. This field does not affect 
    how calls ring at this phone when the phone is on-hook.
    Adjunct Supervision
    Adjunct Supervision appears when the Type field is 
    500, 2500, k2500, 8110, ops, 
    ds1fd, ds1sa, VRU, VRUFD, or VRUSA.
    Assigned Member — Ext
    The system automatically assigns this extension. This is the extension of the user 
    who has an associated Data Extension button and shares the module.
    Assigned Member — Name
    Display-only field that shows the name associated with the extension shown in the 
    Assigned Member - Ext field.
    Valid entries Usage
    continuous
    Enter continuous to cause all calls to this phone to ring 
    continuously.
    single Enter single to cause calls to this phone to receive one ring 
    cycle and then ring silently.
    if-busy-singleEnter if-busy-single to cause calls to this phone to ring 
    continuously when the phone is off-hook and idle and calls to 
    this phone to receive one ring cycle and then ring silently when 
    the phone is off-hook and active.
    silentEnter silent to cause all calls to this station to just ring silently.
    Valid entries Usage
    y
     Enter y if an analog disconnect signal is sent automatically to 
    the port after a call terminates. Analog devices (such as 
    answering machines and speakerphones) use this signal to turn 
    the devices off after a call terminates. 
    nSet this field to n so hunt group agents are alerted to incoming 
    calls. In a hunt group environment, the disconnect signal 
    blocks the reception of zip tone and incoming call notification 
    by an auto-answer station when a call is queued for the station.  
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    886 Station 
    17
    Att. Call Waiting Indication
    Attendant call waiting allows attendant-originated or attendant-extended calls to a 
    busy single-line phone to wait and sends distinctive call-waiting tone to the 
    single-line user. 
    Audible Message Waiting
    The Audible Message Waiting tone indicates that the user has a waiting message. 
    This field appears only if Audible Message Waiting is set to 
    y on the 
    System-Parameters Customer-Options screen. 
    Note that this field does not control the Message Waiting lamp.
    Audix Name
    Specifies which AUDIX is associated with the station.
    Auto Answer
    In EAS environments, the auto answer setting on the Agent LoginID screen may 
    override a station’s setting when an agent logs in there.
    NOTE:
    For analog stations, if Auto Answer is acd and the station is off-hook and 
    idle, only the ACD split/skill calls and direct agent calls auto answer; 
    non-ACD calls receive busy treatment. If the station is active on an ACD call 
    and a non-ACD call arrives, the Agent receives call-waiting tone.
    Valid entries Usage
    y/n 
    Enter y to assign Attendant Call Waiting to the phone. 
    You should not set this field to y, if the Data Restriction field is 
    y or the Switchhook Flash field is n, or if Data Privacy is 
    enabled for the phone’s class of service (COS). If any of these 
    conditions are true, the phone cannot accept or handle call 
    waiting calls.
    Valid entries Usage
    y/n
    Enter y if you want the phone user to receive stutter dial tone 
    when they have a waiting message and they go off-hook. 
    Valid entries Usage
    Names assigned 
    to an AUDIX 
    adjunctMust contain a user-defined adjunct name that was previously 
    administered in the Node-Names screen.  
    						