    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Administrators Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1707
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    777 ISDN-BRI Trunk Circuit Pack 
    17
    CPN Prefix
    Use this field to specify the number that is added to the beginning of the extension 
    to form a Calling or Connected Number.
    Total CPN Len
    ISDN-BRI Trunk Circuit Pack
    This screen administers an ISDN-BRI circuit pack. See DEFINITY ECS System 
    Description for information on the maximum number of ISDN-BRI circuit packs 
    that you can administer.
    Valid entries Usage
    1 to 15 digits Only digits are allowed in the CPN Prefix column.  Leading 
    spaces, or spaces in between the digits, are not allowed.
    nIf the length of the CPN Prefix matches the Total CPN 
    Length, the extension number is not used to formulate the 
    CPN number.
    nIf the number of digits in the CPN Prefix plus the extension 
    length exceeds the administered Total CPN Length, excess 
    leading digits of the extension are deleted when 
    formulating the CPN number. 
    nIf the number of CPN Prefix digits plus the extension 
    length is less than the Total CPN Length, the entry is not 
    allowed. 
    nIf the Total CPN Length is 0, no calling party number 
    information is provided to the called party and no 
    connected party number information is provided to the 
    calling party.
    blank If this field is blank, the extension is sent unchanged. This is 
    useful in countries where the public network is able to insert 
    the appropriate CPN Prefix to form an external DID number.
    Valid entries Usage
    0
     to 15Enter the total number of digits to send. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    778 ISDN-BRI Trunk Circuit Pack 
    17
    Screen 124. BRI Trunk (using a TN2185 circuit pack)
    Location
    This is a display-only field. It shows the TN2185 circuit pack location (PPCSS)
    Name
    Interface Companding
    DCP/Analog Bearer Capability
    Valid entries Usage
    1–15 
    alpha-numeric 
    characters This name is used to identify the circuit pack.
    Valid entries Usage
    a-law
       Indicates the companding algorithm expected by the system at 
    the far end.
    mu-law
    Valid entries Usage
     3.1kHz   Indicates how to encode the Bearer Capability IE for an 
    outgoing call originated by a DCP or analog endpoint.
    speech
    change bri-trunk-board                                             Page 1 of 1
                             ISDN-BRI TRUNK CIRCUIT PACK
                                           
                  Location: 01A09                           Name:  ______________
      Interface Companding: a-law_  DCP/Analog Bearer Capability: 3.1kHz
     T3 Timer Length (sec): 15_             
    Port  Interface  Side  Cntry/Peer TEI  Time  Invert Synch   Layer 1  Detect
                            Protocol       Fill  Bits?  Source? Stable?  Slips?
      1:  user_______        12__     0__  flags   n       n       n       n
      2:  network____  etsi     0__  ones_   y       y       y       y
      3:  user_______        2___  auto flags   y       n       y       n
      4:  peer-slave_  b     QSIG     0__  flags   n       y       y       n
      5:  peer-master  a     QSIG  auto ones_   n       n       n       n
      6:  ___________        ____     0__  ones_   n       n       y       n
      7.  ___________        ____     0__  ones_   n       n       y       n
      8:  ___________        ____     0__  ones_   n       n       y       n
       
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    779 ISDN-BRI Trunk Circuit Pack 
    17
    T3 Timer Length (sec)
    Port
    This is a display-only field. It shows the port number to which parameters 
    administered on the row apply.
    Interface
    Side
    Cntry/Peer Protocol
    Tells call processing software which ISDN protocol standard is applied.
    Valid entries Usage
    1
     to 127  Tells the TE side how long to wait, in seconds, for an inactive 
    Layer 1 to become active.
    Valid entries Usage
    network
    Tells call processing software whether a particular port is 
    connected to a user/network or a peer interface. These entries 
    are valid for the TN2185. You can enter 
    peer-slave only if the 
    QSIG Basic Call Setup feature is enableduser
    peer-master
    peer-slave
    Valid entries Usage
    a
      Determines how glare conditions are handled when Interface 
    field is 
    peer-slave.b
    Valid entries Usage
    1
     to 25When this field is 10, 12, 13, or etsi, the Protocol Version 
    field is equivalent to 
    b on the DS1 circuit pack screen. When 
    the Cntry/Peer Protocol field is set 
    10, 12, 13, or etsi, set the 
    Provol Version field to 
    b. For all other administered values, 
    the Protocol Version sets to 
    a.
    etsi
    QSIG
    When the Interface field is peer-slave or peer-master, this 
    field must be 
    QSIG. The choice QSIG is valid only when the 
    Interface field is 
    peer-slave.
    blank You cannot leave this field blank if the Interface field is set to 
    a valid, non-blank value 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    780 ISDN-BRI Trunk Circuit Pack 
    17
    TEI
    Time Fill
    The bit pattern sent on the D-channel between valid LAPD packets.
    Invert Bits
    Synch Source
    Layer 1 Stable
    Detect Slips
    Valid entries Usage
    auto
    0
    Valid entries Usage
    flags
     
    ones 
    Valid entries Usage
    y/n
    Valid entries Usage
    y
    n
     
    Valid entries Usage
    y
      Tells call processing and maintenance software whether to 
    expect the network to drop Layer 1 when the BRI port is idle. 
    Only the TN2185 may be set to 
    n.n
    Valid entries Usage
    y/n
    Tells maintenance software whether slips reported by the BRI 
    port should be logged. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    781 ISDN-BRI Trunk Circuit Pack 
    17
    Field descriptions for page 1
    Screen 125. BRI Trunk (with a TN556B or TN2198 circuit pack)
    The following field descriptions are unique to the ISDN-BRI Circuit Pack screen 
    with a TN556B or TN2198 circuit pack. The following fields do not display with a 
    TN556B or TN2198 circuit pack:
    nT3 Timer Length (sec)
    nSynch Source
    nLayer 1 Stable
    nDetect Slips
    Interface
    Valid entries Usage
    network
    Tells call processing software whether a particular port is 
    connected to a user/network or a peer interface. These entries 
    are valid for the TN556B. You can enter 
    peer-master only if 
    the QSIG Basic Call Setup feature is enabledpeer-master
    change bri-trunk-board                                       Page 1 of 1
                             ISDN-BRI TRUNK CIRCUIT PACK
                                           
                   Location: 01A09                   Name:  ______________
       Interface Companding: a-law_  DCP/Analog Bearer Capability: 3.1kHz
    Port  Interface   Side  Cntry/Peer TEI  Time Invert 
                            Protocol        Fill  Bits? 
      1:  network__           12__     0__  flags   n   
      2:  network__           etsi     0__  ones_   y   
      3:  network__           2___     auto flags   y   
      4:  peer-master  b      QSIG     0__  flags   n   
      5:  peer-master  a      QSIG     auto ones_   n   
      6:  __________          ____     0__  ones_   n   
      7.  __________          ____     0__  ones_   n   
      8:  __________          ____     0__  ones_   n   
     9:  __________          ____     0__  ones_   n
     10:  __________          ____     0__  ones_   n
     11:  __________          ____     0__  ones_   n
     12:  __________          ____     0__  ones_   n 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    782 ISDN-BRI Trunk Circuit Pack 
    17
    Side
    Cntry/Peer Protocol
    Tells call processing software which ISDN protocol standard is applied.
    Field descriptions for page 2
    NOTE:
    If administering a TN2185 circuit pack, 8 ports appear; otherwise, 12 
    ports appear.
    Valid entries Usage
    a
      Determines how glare conditions are handled when Interface 
    field is peer-slave. This field is not administrable when the 
    Interface field is 
    network.b
    Valid entries Usage
    1 
    to 25When this field is 10, 12, or 13, the Protocol Version field is 
    equivalent to 
    b on the DS1 circuit pack screen.
    etsiWhen this field is etsi, the Protocol Version field is equivalent 
    to 
    b on the DS1 circuit pack screen.
    QSIGWhen the Interface field is peer-master, this field must be 
    QSIG.
    blank You cannot leave this field blank if the Interface field is set to 
    a valid, non-blank value. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    783 ISDN-BRI Trunk Circuit Pack 
    17
    Screen 126. BRI Trunk - Page 2 (using a TN2185 circuit pack)
    Screen 127. BRI Trunk - Page 2 (using a TN2198/TN556B circuit pack)
    NOTE:
    You cannot change the Endpt Init, SPID, or Endpt ID port parameters 
    unless that port is busied out or unadministered. It is possible to 
    change all other fields on this page even if the corresponding port is 
    active.
    change bri-trunk-board                                    Page 2 of 2
                             ISDN-BRI TRUNK CIRCUIT PACK
                                           
     Port  Interwork  XID  Endpt    SPID      Endpt    SPID      Endpt  Max
           Message   Test? Init?               ID                ID   NCA TSC
       1:  PROGress   y      n   ____________  __   ____________  __     0___
       2:  ALERTing   y      y   908957200000  __   ____________  __     0___
       3:  PROGress   y      y   0001________  __   ____________  __     0___
       4:  PROGress   n      n   ____________  __   ____________  __     0___
       5:  PROGress   n      y   625761449___  01   ____________  __     0___
       6:  PROGress   n      n   ____________  __   ____________  __     0___
       7.  PROGress   n      n   ____________  __   ____________  __     0___
       8:  PROGress   n      n   ____________  __   ____________  __     0___
       Port Directory   Directory         Port Directory   Directory
              Number      Number                 Number      Number
         1:                                 5:
         2:                                 6:
         3:                                 7:
         4:                                 8:
    change bri-trunk-board                                    Page 2 of 2
                             ISDN-BRI TRUNK CIRCUIT PACK
                                           
     Port Interwork XID Endpt    SPID      Endpt                     Max
           Message   Test? Init?               ID                     NCA TSC
       1:  PROGress   n      y   ____________  __                        0___
       2:  ALERTing   n      y   ____________  __                        0___
       3:  PROGress   n      y   ____________  __                        0___
       4:  PROGress   n      y   ____________  __                        0___
       5:  PROGress   n      y   ____________  __                        0___
       6:  PROGress   n      y   ____________  __                        0___
       7.  PROGress   n      y   ____________  __                        0___
       8:  PROGress   n      y   ____________  __                        0___
       9:  PROGress   n      y   ____________  __                        0___
      10:  PROGress   n      y   ____________  __                        0___
      11:  PROGress   n      y   ____________  __                        0___
      12:  PROGress   n      y   ____________  __                        0___ 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    784 ISDN-BRI Trunk Circuit Pack 
    17
    NOTE:
    If the Interface field on page 1 contains a valid value when the screen 
    is submitted, the contents of the fields on page 2 for that port are 
    validated.  If the Interface field is blank when the screen is submitted, 
    the fields on this page for that port reset to their default values.
    Port
    This is a display-only field. It shows the port number to which parameters 
    administered on the row apply.
    Interworking Message
    This field determines what message the switch sends when an incoming ISDN 
    trunk call interworks (is routed over a non-ISDN trunk group).
    XID Test
    Endpt Init 
    Indicates whether the far end supports endpoint initialization. DEFINITY ECS 
    blocks you from changing this field unless the port is busied out or 
    unadministered. 
    Valid entries Usage
    PROGress
    Normally select this value. PROGress asks the public network 
    to cut through the B-channel and let the caller hear tones such 
    as ringback or busy tone provided over the non-ISDN trunk.
    ALERTingALERTing causes the public network in many countries to 
    play ringback tone to the caller. Select this value only if the 
    DS1 is connected to the public network, and it is determined 
    that callers hear silence (rather than ringback or busy tone) 
    when a call incoming over the DS1 interworks to a non-ISDN 
    trunk.
    Valid entries Usage
    y/n
    Indicates whether the far end supports the Layer 2 XID test.
    Valid entries Usage
     y  If set to y, the SPID field must not be blank. DEFINITY ECS 
    blocks you from changing this field and the SPID field unless 
    that port is busied out or unadministered.
    nIf set to n, the SPID and Endpt ID fields must be blank. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    785 ISDN-BRI Trunk Circuit Pack 
    17
    SPID
    A 12-digit field containing the SPID expected by the far end. DEFINITY ECS 
    blocks you from changing this field unless the port is busied out or 
    unadministered. The only protocol supported for SPID initialization is Bellcore 
    (Country Code 1). Trunks will not be put in service if SPID installation is not 
    successful.
    Endpt ID
    A 2-digit field containing the Endpoint Identifier expected by the far end. 
    DEFINITY ECS blocks you from changing this field unless the port is busied out 
    or unadministered.  
    Max NCA TSC
    Port
    This is a display-only field. It shows the port number to which parameters 
    administered on the row apply.
    Directory Number
    These 10-digit fields contain the directory numbers assigned to the interface, 
    which it views as being allocated to 2 separate endpoints. 
    Valid entries Usage
    Any string of 1 to 12 
    digits Leading zeroes considered significant and not 
    ignored
    Valid entries Usage
    00
     to 62Leading zeroes considered significant and not ignored.
    Valid entries Usage
    0
     through 63.  This 2-digit field gives the maximum number of 
    Non-Call-Associated Temporary Signaling Connections 
    allowed on this BRI D-channel. This field’s function is the 
    same as the field with the same name on the Signaling Group 
    screen.
    Valid entries Usage
    Any string of 
    1 to 10 digitsThese fields must be administered in pairs. That is, if you enter a 
    value in one field, you must enter a value in the other. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1
    April 2000
    Screen reference 
    786 Language Translations 
    17
    Trunk Member Administration
    Administer BRI trunk members using the following scheme to address the 
    individual B-channels:
    nB-channel 1 uses the port address of the BRI Trunk Port.
    nB-channel 2 uses the port address of B-channel 1 incremented by 16.
    When adding a BRI trunk to an ISDN trunk-group, DEFINITY ECS blocks you 
    from administering a Signaling Group for that trunk member.
    DEFINITY ECS blocks you from administering a BRI trunk member if the port 
    has not yet been administered on the BRI Trunk screen.
    For example, administer the B-channels on a TN2185 circuit pack inserted in slot 
    01A10 as follows:
    Interactions
    The 
    add bri-trunk board PPCSS command is rejected if PPCSS identifies a 
    TN556B circuit pack, and a port on that circuit pack has already been assigned to 
    a station or data-module. If a TN556B circuit pack has been administered as a BRI 
    trunk circuit pack, any port on that circuit pack is prevented from being assigned 
    to a station or data-module.
    Language Translations
    When you want to use a language other than English, French, Italian, and Spanish 
    to display messages on your display phones, use the Language Translation screens 
    to define the messages. Set up your messages using Roman letters, punctuation, 
    digits and blank spaces. Diacritical marks are not supported.
    Port B-channel 1 B-channel 2
    1 01A1001 01A1017
    2 01A1002 01A1018
    3 01A1003 01A1019
    4 01A1004 01A1020
    5 01A1005 01A1021
    6 01A1006 01A1022
    7 01A1007 01A1023
    8 01A1008 01A1024 
    						
    All Lucent Technologies manuals Comments (0)