Q- WIDE QK- CEU IDENTIFICATION Description Related Programming Feature Reference Instructions Issue 1-O Step 1 l 1 Step Step 3 Step l Use this option to enter the System Identification. The System Identification is four lines long. up to 17 characters in each line. It can consist of any combination of characters A-Z and the digits O-9, and Conditions Default No System Identification programmed. Automatic Fault Reporting J- Communications Port Parameters, Port Speed Set the baud rate for Port A (modem) and Port B (local) to match the connected device. (The attendant can set these options from the telephone. See page 2-2) J- Communications Port Parameters, Ring Count Set the Automated Answer ring count to match the setting of the connected modem. QC- Operator Programming, Operator Alarms Suppress/allow alarm indications at attendant extensions. QV- Trouble Report Telephone Number This is the number the dials to report a major alarm to the off-site service center. Automatic Fault Reporting System Identification To enter data on PRF: For QK- KSU ID on Table 10, enter the System Identification. To enter data at the programming terminal: Type Q. You see: Type K. You see: KSU ID: Enter the data for QK- KSU (line 1) from Table 10 and press RETURN. You go to the second line. If you enter 17 characters, don’t have to press RETLJRN. To erase an entry for an entire line. press space bar and RETURN. Repeat step 3 for lines 2-4. CONFIGURATION2-275
Q- SYSTEM WIDE QL- CODES, ACCOUNT CODES Description Related Programming l l Feature Reference Step Step Step 2 Step 3 l Step l Use this option to enable (Y) or disable Mandatory Account Codes system-wide. Conditions Default Mandatory Account Codes disabled (N). Account Code Verifiable Account Code List Enter up to 601 codes into the Verifiable Account Code List. QL- Codes, Verifiable Account Codes Enable/disable Verifiable Account Codes. QL- Codes, Account Codes for Toll Calls Only Enable/disable Mandatory Account Codes for all outside calls or just for toll (1+) calls. QL- Codes, Minimum COS for Mandatory Account Codes Set the minimum COS number that requires Mandatory Account Codes. Account Code Capability To enter data on PRF: For QL- Codes Mandatory on Table 10, enter Y or N. To enter data at the pro&ramming terminal: Type You see: Type L. see: ACCT CODES MANDATORY? Enter Y or N for QL- Codes Mandatory from Table 10. If you enter Y for step 3, go to QL- Verifiable Account Codes on the next OR If you enter N for step 3, go to QL- LCR or ARS Enable Issue 1-O
Q- SYSTEM WIDE PROGRAMMING QL- CODES. ACCOUNT CODES Description ted Programming l l Feature Reference Instructions Step 1 Step l Step l Issue 1-O Use this option to enable (Y) or disable (N) Verifiable Account Codes wide. Conditions None Default Verifiable Account Codes disabled (N). Account Code Capability QI- Verifiable Code List Enter up to 601 codes into the Verifiable Account Code List. QL- Codes, Account Codes Enable/disable Mandatory Account Codes. QL- Codes, Account Codes for Calls Only Enable/disable Mandatory Account Codes for all outside calls or just for toll calls. QL- Codes, Minimum COS for Mandatory Account Codes Set the minimum COS number that requires Mandatory Account Codes. Account Code Capability To enter data on the PRF: For QL- Verify Codes on Table 10, enter Y or N. To enter data at the programming terminal: After entering Y for QL- Mandatory Account Codes, you see: VERIFY CODES? Enter Y or for QL- Verify Codes from Table 10. In either case, you see: ACCT CODES FOR TOLL CALL ONLY? Go to Account Codes for Toll Calls Only on the next page. SOFTWARE CONFIGURATION2-277
Q- SYSTEM WIDE QL- CODES, ACCT CODES FOR TOLL ONLY Description Related Programming l l l Feature Reference Instructions Step 1 l Step l Step l Use this option to enforce Account Codes for all trunk calls (N) or for just toll trunk calls Conditions None Default Account codes enabled for all trunk calls (N). Account Coded Capability Verifiable Account Code List Enter up to 661 codes into the Verifiable Account Code List. QL- Codes, Account Codes Enable/disable Mandatory Account Codes. QL- Codes, Verifiable Account Codes Enable/disable Verifiable Account Codes. QL- Codes, Minimum COS for Mandatory Account Codes Set the minimum COS number that requires Mandatory Account Codes. Account Code Capability To enter data on the PRF: For QL- Codes for Toll Call Only on Table 10, enter Y or N. To enter data at the programming terminal: After entering data for QL- Verifiable Account Codes, you see: ACCT CODES FOR TOLL CALL ONLY? Enter Y or N for QL- Codes for Toll Call Only from Table 10. You see: MIN. COS REQUIRING ACCT CODEGo to QL- Minimum COS for Mandatory Account Codes on the next page.
Q- SYSTEM WIDE QL- CODES. COS FOR MANDATORY ACCOUNT CODES Description Related Programming Feature Reference Instructions Step 1 Step Step Use this option to set the minimum COS number that requires Mandator); Account Code For example, entering 15 requires 15-27 to enter Account Codes. do not have to enter Account Codes. To force all extension users to enter Account Codes (including attendants). enter 00. Conditions None Default Only COS 27 must enter an Account Code (27). Account Code Capability Verifiable Account Code List Enter up to 601 codes into the Verifiable Account Code List. QL- Codes, Mandatory Account Codes Enable/disable Mandatory Account Codes. QL- Codes, Verifiable Account Codes Enable/disable Verifiable Account Codes. QL- Codes, Account Codes for Toll Calls Only Enable/disable Mandatory Account Codes for all outside calls or just for calls. Account Code Capability To enter data on the PRF: Enter a COS number (00-27) for QL- Min Cos Requiring Code on Table 10. To enter data at the programming terminal: After entering data for QL- Account Codes for Toll Calls Only, you see: REQUIRING ACCT CODE? Enter data for QL- Min. COS Requiring Code from Table 10. You see: Go to QL- LCR or ARS Enable on the next page. Issue 1-OSOFTWARE CONFIGURATION2-279
Q- SYSTEM WIDE QL- CODES, ENABLE (HYBRID ONLY) Description Related Programming l l l l Use this option to enable LCR or ARS. The choices are: 0 not 1 LCR enabled ARS enabled’ This option is not on key Conditions None Default Value LCR and ARS disabled (0). Automatic Route Selection E- Trunks, E-l- Trunk in Outbound Rotary ARS requires outbound trunk rotaries. This prompt determines the selection sequence for-trunks within each rotary. E- Trunks, Trunk Service Number Assign a Service Number to-each trunk used for ARS. ARS routes calls to Service Numbers, not trunks. E- Trunks, EA- Trunk Group Assignment (First Trunk in Group trunks in rotaries by assigning each one the same First Trunk in Group number. GA- ARS Editor Program the ARS options. Refer to Appendix A for complete details. QL- Codes, Number of Services Designate how many services (trunk rotaries) ARS will use. QL- Codes, Service Line Numbers Indicate the trunk rotary master number for each of the rotaries used by ARS. This should correspond to the EA- First Trunk in Group entry. Least Cost Routing E- Trunks, Trunk Service Number Assign a Service Number to each trunk used for LCR. LCR routes calls to Service Numbers, not individual trunks. GL- LCR Testing Use this option to display your current LCR configuration and make changes to your LCR database. QL- Codes! Number of Services Designate how many services (trunk rotaries) LCR will use. QL- Codes, Service Line Numbers Indicate the trunk rotary master number for each of the rotaries used by LCR. This should correspond to the EA- First Trunk in Group entry. QL- LCR/ARS/Account Codes, COS Needed to Access ALT Route Enter the minimum COS that the system requires before routing a call to the alternate route (if primary route is busy). QL- Codes, Type of Service Enter the type of service number (O-5). For example, for DDD or WATS, enter 0. QL- Codes, Access Code For dial-up services, enter the access code (telephone number) for the service. QL- Codes, Security Code For dial-up services, enter the security code the service requires. Refer to Appendix A for details on programming ARS.
Q- WIDE PROGRAMMING QL- CODES, (HYBRID -- Feature Reference Instructions Step l Step 1 l Step Issue 1-O Automatic Route Selection Least Cost Routing To enter data on the PRF: For QL- LCR on Table enter 0. or 2. To enter data at the programming terminal: After programming QL- Minimum COS for Mandatory Account Codes or entering N for QL- Mandatory Account Codes, you see: LCR INST’D) Enter 0. 1 or 2 for QL- LCR Inst’d) from Table 10. if you enter or you see: NO. OF CO SERVICES (01-10)If you I or go to of on the next page. If you enter 0. to the Main Menu. SOFTWARE CONFIGURATION2-281
QL- CODES. LCR OR ENABLE For 2-282 SOFTWARE Issue 1-O
Q- SYSTEM WIDE PROGRAMMING QL- CODES, NUMBER OF SERVICES Description Related Programming l l l l l Use this option to designate how many services (trunk rotaries) LCR or will use.’ The choices are 0 This prompt appears only if you enter or 2 for the QL- LCR OR option. This option does not apply to None No services designated (00). Automatic Route Selection E- Trunks, E-l- Trunk in Outbound Rotary ARS requires outbound trunk rotaries. This prompt determines the selection sequence for trunks within each rotarv. Trunks, Service Number Assign a Service Number to each trunk used for ARS. ARS routes calls to Service Numbers, not individual trunks. E- Trunks, Trunk Group Assignment (First Trunk in Group) Group trunks in rotaries by assigning each one the same First Trunk in Group number. ARS Editor Program the ARS options. Refer to Appendix A for complete details. QL- Codes, LCR or ARS Enable Enter 2 to enable ARS. QL- Codes, Service Line Numbers Indicate the trunk rotary master number for each of the rotaries used by ARS. This should correspond to the First Trunk in Group entry. Least Cost Routing E- Trunks, Trunk Service Number Assign a Service Number to each trunk used for LCR. LCR routes calls to Service Numbers, not individual trunks. CL- LCR Testing Use this option to display your current LCR configuration and make changes to your LCR database. QL- Codes, LCR or ARS Enable Enter 1 to enable LCR. QL- Codes, Service Line Numbers Indicate the trunk rotary master number for each of the rotaries used by LCR. This should correspond to the First Trunk in Group entry. QL- Codes, COS Needed to Access ALT Route Enter the minimum COS that the system requires before routing a call to the alternate route (if primary route is busy). QL- Codes, Type of Service Enter the type of service number (O-5). For example, for DDD or WATS, enter 0. QL- Codes, Access Code services, enter the access code (telephone number) for the service. QL- Codes, Security Code For dial-up services, enter the security code the service requires. Refer Appendix A for details on programming Issue 1-O . CONFIGURATION2-283
Q- SYSTEM WIDE QL- CODES, SERVICES Feature Reference Instructions Step Step Step l Automatic Route Selection Least Cost Routing To enter data on the PRF: For QL- No. of IO). enter the number of (trunk rotaries) ARS or LCR use. To enter data at the programming terminal: After programming QL- LCR or ARS Enable, you see: NO. OF CO SERVICES (01-10) Enter the number of services for QL- No. of Services from Table 10. You see: SERVICE 01 LINE NUMBERGo to QL- Line Numbers on the next page.