Home > TiE > Telephone > TiE Onyx 2, 3, 4, 5 Service And Programming Manual

TiE Onyx 2, 3, 4, 5 Service And Programming Manual

    Download as PDF Print this page Share this page

    Have a look at the manual TiE Onyx 2, 3, 4, 5 Service And Programming Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 13 TiE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 672
    							Q-  WIDE 
    QK- CEU IDENTIFICATION
    Description
    Related
    Programming
    Feature Reference
    Instructions
    Issue 1-O
    Step 1 l
     1 
    Step  
    Step 3 
    Step  l
    Use this option to enter the System Identification. The System Identification
    is four lines long. 
     up to 17 characters in each line. It can consist of any
    combination of characters A-Z and the digits O-9, 
     and 
    Conditions
    Default 
    No System Identification programmed.
    Automatic Fault Reporting
    J- Communications Port Parameters, Port Speed 
     Set the baud rate for
    Port A (modem) and Port B (local) to match the connected device. (The
    attendant can set these options from the telephone. See page 2-2)
    J- Communications Port Parameters,  Ring Count  Set the
    Automated Answer ring count to match the setting of the connected modem.
    QC- Operator Programming,  Operator Alarms  Suppress/allow
    alarm indications at attendant extensions.
    QV- Trouble Report Telephone Number  This is the number the 
    dials to report a major alarm to the off-site service center.
    Automatic Fault Reporting
    System Identification
    To enter data on  PRF:
    For QK- KSU ID on Table 10, enter the System Identification.
    To enter data at the programming terminal:
    Type Q. You see: 
    Type K. You see: KSU ID:
    Enter the data for QK- KSU  (line 1) from Table 10 and press RETURN.
    You go to the second line.
    If you enter 17 characters,  don’t have to press RETLJRN.
    To erase an entry for an entire line. press space bar and RETURN.
    Repeat step 3 for lines 2-4.
     CONFIGURATION2-275 
    						
    							Q- SYSTEM WIDE 
    QL-  CODES,  ACCOUNT CODES
    Description
    Related
    Programming
    l
    l
    Feature Reference
    Step  
    Step  
    Step 2 
    Step 3 l
    Step  l
    Use this option to enable (Y) or disable  Mandatory Account Codes
    system-wide.
    Conditions
    Default 
    Mandatory Account Codes disabled (N).
    Account Code 
     Verifiable Account Code List  Enter up to 601 codes into the Verifiable
    Account Code List.
    QL-  Codes, Verifiable Account Codes  Enable/disable
    Verifiable Account Codes.
    QL-  Codes, Account Codes for Toll Calls Only 
    Enable/disable Mandatory Account Codes for all outside calls or just for toll
    (1+) calls.
    QL-  Codes, Minimum COS for Mandatory Account
    Codes 
     Set the minimum COS number that requires Mandatory Account
    Codes.
    Account Code Capability
    To enter data on  PRF:
    For QL- 
     Codes Mandatory on Table 10, enter Y or N.
    To enter data at the pro&ramming terminal:
    Type 
     You see: 
    Type L.  see: ACCT CODES MANDATORY?
    Enter Y or N for QL-  Codes Mandatory from Table 10.
    If you enter Y for step 3, go to QL- Verifiable Account Codes on the next
    OR
    If you enter N for step 3, go to QL- LCR or ARS Enable
      Issue 1-O 
    						
    							Q- SYSTEM WIDE PROGRAMMING
    QL-  CODES.  ACCOUNT CODES
    Description
     ted
    Programming
    l
    l
    Feature Reference
    Instructions
    Step 1 
    Step  l
    Step  l
    Issue 1-O
    Use this option to enable (Y) or disable (N) Verifiable Account Codes 
    wide.
    Conditions
    None
    Default 
    Verifiable Account Codes disabled (N).
    Account Code Capability
    QI- Verifiable 
     Code List  Enter up to 601 codes into the Verifiable
    Account Code List.
    QL- 
     Codes,  Account Codes 
    Enable/disable Mandatory Account Codes.
    QL- 
     Codes, Account Codes for  Calls Only 
    Enable/disable Mandatory Account Codes for all outside calls or just for toll
     calls.
    QL-  Codes, Minimum COS for Mandatory Account
    Codes 
     Set the minimum COS number that requires Mandatory Account
    Codes.
    Account Code Capability
    To enter data on the PRF:
    For QL- Verify Codes on Table 10, enter Y or N.
    To enter data at the programming terminal:
    After entering Y for QL- Mandatory Account Codes, you see: 
    VERIFY
    CODES?
    Enter Y or  for QL- Verify Codes from Table 10. In either case, you see:
    ACCT CODES FOR TOLL CALL ONLY?
    Go to  Account Codes for Toll Calls Only on the next page.
    SOFTWARE CONFIGURATION2-277 
    						
    							Q- SYSTEM WIDE 
    QL-  CODES, ACCT CODES FOR TOLL  ONLY
    Description
    Related
    Programming
    l
    l
    l
    Feature Reference
    Instructions
    Step 1 l
    Step  l
    Step  l
    Use this option to enforce Account Codes for all trunk calls (N) or for just toll
     trunk calls 
    Conditions
    None
    Default 
    Account codes enabled for all trunk calls (N).
    Account Coded Capability
     Verifiable Account Code List  Enter up to 661 codes into the Verifiable
    Account Code List.
    QL-  Codes,  Account Codes 
    Enable/disable Mandatory Account Codes.
    QL- 
     Codes, Verifiable Account Codes  Enable/disable
    Verifiable Account Codes.
    QL-  Codes, Minimum COS for Mandatory Account
    Codes 
     Set the minimum COS number that requires Mandatory Account
    Codes.
    Account Code Capability
    To enter data on the PRF:
    For QL- 
     Codes for Toll Call Only on Table 10, enter Y or N.
    To enter data at the programming terminal:
    After entering data for QL- Verifiable Account Codes, you see: 
    ACCT CODES
    FOR TOLL CALL ONLY?
    Enter Y or N for QL-  Codes for Toll Call Only from Table 10. You see:
    MIN. COS REQUIRING ACCT CODEGo to QL- Minimum COS for Mandatory Account Codes on the next page. 
    						
    							Q- SYSTEM WIDE 
    QL-  CODES.  COS FOR MANDATORY
    ACCOUNT CODES
    Description
    Related
    Programming
    Feature Reference
    Instructions
    Step 1 
    Step  
    Step  
    Use this option to set the minimum COS number that requires Mandator);
    Account Code  For example, entering 15 requires  15-27 to enter
    Account Codes. 
      do not have to enter Account Codes. To force
    all extension users to 
    enter Account Codes (including attendants). enter 00.
    Conditions
    None
    Default 
    Only COS 27 must enter an Account Code (27).
    Account Code Capability
     Verifiable Account Code List  Enter up to 601 codes into the Verifiable
    Account Code List.
    QL- 
     Codes, Mandatory Account Codes 
    Enable/disable Mandatory Account Codes.
    QL- 
     Codes, Verifiable Account Codes  Enable/disable
    Verifiable Account Codes.
    QL- 
     Codes, Account Codes for Toll Calls Only 
    Enable/disable Mandatory Account Codes for all outside calls or just for 
     calls.
    Account Code Capability
    To enter data on the PRF:
    Enter a COS number (00-27) for QL- Min Cos Requiring 
     Code on Table
    10.
    To enter data at the programming terminal:
    After entering data for QL- Account Codes for Toll Calls Only, you see: 
     REQUIRING ACCT CODE?
    Enter data for QL- Min. COS Requiring  Code from Table 10. You see:
         
    Go to QL- LCR or ARS Enable on the next page.
    Issue 1-OSOFTWARE CONFIGURATION2-279 
    						
    							Q- SYSTEM WIDE 
    QL-  CODES,  ENABLE (HYBRID ONLY)
    Description
    Related
    Programming
    l
    l
    l
    l
    Use this option to enable LCR or ARS. The choices are:
    0 
     not 
    1 LCR enabled
     ARS enabled’
    This option is not 
     on key 
    Conditions
    None
    Default Value
    LCR and ARS disabled (0).
    Automatic Route Selection
    E- Trunks, E-l- 
     Trunk in Outbound Rotary  ARS requires outbound
    trunk rotaries. This prompt determines the selection sequence for-trunks
    within each rotary.
    E- Trunks,  Trunk Service Number  Assign a Service Number to-each
    trunk used for ARS. ARS routes calls to Service Numbers, not trunks.
    E- Trunks, EA- Trunk Group Assignment (First Trunk in  
    Group trunks in rotaries by assigning each one the same First Trunk in Group
    number.
    GA- ARS Editor  Program the ARS options. Refer to Appendix A for
    complete details.
    QL-  Codes, Number of Services  Designate how many
    services (trunk rotaries) ARS will use.
    QL-  Codes, Service Line Numbers  Indicate the trunk
    rotary master number for each of the rotaries used by ARS. This should
    correspond to the 
    EA- First Trunk in Group entry.
    Least Cost Routing
    E- Trunks,  Trunk Service Number  Assign a Service Number to each
    trunk used for LCR. LCR routes calls to 
    Service Numbers, not individual
    trunks.
    GL- LCR Testing  Use this option to display your current LCR
    configuration and make changes to your LCR database.
    QL-  Codes! Number of Services  Designate how many
    services (trunk rotaries) LCR will use.
    QL-  Codes, Service Line Numbers  Indicate the trunk
    rotary master number for each of the rotaries used by LCR. This should
    correspond to the 
    EA- First Trunk in Group entry.
    QL- LCR/ARS/Account Codes, COS Needed to Access ALT Route  Enter
    the minimum COS that the system requires before routing a call to the
    alternate route (if primary route is busy).
    QL-  Codes, Type of Service  Enter the type of service
    number (O-5). For example, for DDD or WATS, enter 0.
    QL-  Codes, Access Code  For dial-up services, enter
    the access code (telephone number) for the service. 
    QL-  Codes, Security Code  For dial-up services, enter
    the security code the service requires.
    Refer to Appendix A for details on programming ARS. 
    						
    							Q-  WIDE PROGRAMMING
    QL- 
     CODES,   (HYBRID --
    Feature Reference
    Instructions
    Step  l
    Step 1 l
    Step  
    Issue 1-O
    Automatic Route Selection
    Least Cost Routing
    To enter data on the PRF:
    For QL- LCR on Table 
     enter 0.  or 2.
    To enter data at the programming terminal:
    After programming QL- Minimum COS for Mandatory Account Codes or
    entering N for QL- Mandatory Account Codes, you see: 
    LCR 
      INST’D)
    Enter 0. 1 or 2 for QL- LCR    Inst’d) from
    Table 10. if you enter 
     or  you see: NO. OF CO SERVICES (01-10)If you  I or go to   of  on the next page.
    If you enter 0.   to the Main Menu.
    SOFTWARE CONFIGURATION2-281 
    						
    							    
    QL-  CODES. LCR OR  ENABLE
     For   
    2-282 SOFTWARE  Issue 1-O 
    						
    							Q- SYSTEM WIDE PROGRAMMING
    QL- 
     CODES, NUMBER OF SERVICES
    Description
    Related
    Programming
    l
    l
    l
    l
    l
    Use this option to designate how many services (trunk rotaries) LCR or 
    will use.’ The choices are 0    This prompt appears only if you enter  or
    2 for the QL- LCR OR 
      option.
    This option does not apply to 
     
    None
     
    No services designated (00).
    Automatic Route Selection
    E- Trunks, E-l- 
     Trunk in Outbound Rotary  ARS requires outbound
    trunk rotaries. This prompt determines the selection sequence for trunks
    within each rotarv.
     Trunks,   Service Number  Assign a Service Number to each
    trunk used for ARS. ARS routes calls to Service Numbers, not individual
    trunks.
    E- Trunks,  Trunk Group Assignment (First Trunk in Group) 
    Group trunks in rotaries by assigning each one the same First Trunk in Group
    number.
     ARS Editor  Program the ARS options. Refer to Appendix A for
    complete details.
    QL-  Codes, LCR or ARS Enable  Enter 2 to enable
    ARS.
    QL-  Codes, Service Line Numbers  Indicate the trunk
    rotary master number for each of the rotaries used by ARS. This should
    correspond to the 
     First Trunk in Group entry.
    Least Cost Routing
    E- Trunks,  Trunk Service Number  Assign a Service Number to each
    trunk used for LCR. LCR routes calls to Service Numbers, not individual
    trunks.
    CL- LCR Testing  Use this option to display your current LCR
    configuration and make changes to your LCR database.
    QL-  Codes, LCR or ARS Enable  Enter 1 to enable
    LCR.
    QL-  Codes, Service Line Numbers  Indicate the trunk
    rotary master number for each of the rotaries used by LCR. This should
    correspond to the 
     First Trunk in Group entry.
    QL- 
     Codes, COS Needed to Access ALT Route  Enter
    the minimum COS that the system requires before routing a call to the
    alternate route (if primary route is busy).
    QL-  Codes, Type of Service  Enter the type of service
    number (O-5). For example, for DDD or WATS, enter 0.
    QL- 
     Codes, Access Code   services, enter
    the access code (telephone number) for the 
    service.
    QL- 
     Codes, Security Code  For dial-up services, enter
    the security code the service requires.
    Refer  Appendix A for details on programming 
    Issue 1-O . CONFIGURATION2-283 
    						
    							Q- SYSTEM WIDE 
    QL-  CODES,   SERVICES
    Feature Reference
    Instructions
    Step  
    Step  
    Step  l
    Automatic Route Selection
    Least Cost Routing
    To enter data on the PRF:
    For QL- No. of 
       IO). enter the number of  (trunk rotaries)
    ARS or LCR 
     use.
    To enter data at the programming terminal:
    After programming QL- LCR or ARS Enable, 
    you see: NO. OF CO SERVICES
    (01-10)
    Enter the number of services for QL- No. of Services from Table 10. You
    see: SERVICE 01 LINE NUMBERGo to QL-  Line Numbers on the next page. 
    						