SM 5-233 B230/B237/D042 Service Tables Enables/disables initiating a call when the front door remains open. Jam Detection: Time Length [3 to 30 / 10 / 1 minute /step] 011* Sets the time a jam must remain before it becomes an “unattended paper jam”. This setting is enabled only when SP5508-004 is set to 1. Jam Detection: Continuous Count [2 to 10 / 5 / 1 /step] 012* Sets the number of consecut ive paper jams required to initiate a call. This setting is enabled only when SP5508-004 is set to 1. Door Open: Time Length [3 to 30 / 10 / 1 /step] 013* Sets the length of time the door rema ins open before the machine initiates a call. This setting is enabled only when SP5-508-004 is set to 1. Jam Operation: Time Length 0: Automatic Call 1 : Audible Warning at Machine 021* Determines what happens when a paper jam is left unattended. Jam Operation: Continuous Count 0: Automatic Call 1 : Audible Warning at Machine 022* Determines what happens when consecutive paper jams occur. Door Operation: Time Length 0: OFF, 1: ON 023* Determines what happens if the door remains open (15 min.). Displays a warning if set to ON. Pr essing the call button will contact the service center. This setting is available for setting only if SP5508-004 is set to 1. [SC/Alarm Setting] *CTL - 5515 With NRS (New Remote Service) in use, these SP codes can be set to issue an SC call when an SC error occurs. If th is SP is switched off, the SC call is not issued when an SC error occurs.
B230/B237/D042 5-234 SM 001 SC Call 002 Service Parts Near End Call 003 Service Parts End Call 004 User Call [0 or 1 / 1 / - ] 0: Off 1: On 006 Communication Test Call 007 Machine Information Notice 008 Alarm Notice 009 Non Genuine Toner Alarm 010 Supply Automatic Ordering Call 011 Supply Management Report Call 012 Jam/Door Open Call [0 or 1 / 1 / - ] 0: Off 1: On 5516 [Individual PM Part Alarm Call] *CTL - 001 Disable/ Enable Setting Enables or disables t he PM part alarm call. [0 or 1 / 1 / - ] 0: Not Send, 1: Send 002 Alarm Flag Displays the condition of the PM part alarm call. [0 or 1 / 1 / - ] 0: Ready (to send), 1: Already Send 003 Alarm Flag Clear Clears the alarm flag (SP5-516-002). Do this SP after servicing for PM parts. So, SP5-516-002 is set to 0.
SM 5-235 B230/B237/D042 Service Tables 5610 [ACC Factory Setting] Recall - - 004 Recalls the factory settings. Overwrite - - 005 Overwrites the current values onto the factory settings. Previous Setting - - 006 Recalls the previous settings. 5611 [Toner Color in 2C] B-C *ENG [0 to 128 / 100 / 1 /step] 128: Darkest density 001 Adjusts the Cyan correction value of the blue signal in two-color mode. B-M *ENG[0 to 128 / 100 / 1 /step] 128: Darkest density 002 Adjusts the Magenta correction value of the blue signal in two-color mode. G-C *ENG[0 to 128 / 100 / 1 /step] 128: Darkest density 003 Adjusts the Cyan correction value of the blue signal in two-color mode. G-Y *ENG[0 to 128 / 100 / 1 /step] 128: Darkest density 004 Adjusts the Yellow correction value of the blue signal in two-color mode. R-M *ENG [0 to 128 / 100 / 1 /step] 128: Darkest density 005 Adjusts the Magenta correction value of the blue signal in two-color mode. 006 R-Y *ENG [0 to 128 / 100 / 1 /step]
B230/B237/D042 5-236 SM 128: Darkest density Adjusts the Yellow correction value of the blue signal in two-color mode. 5618 [Color Mode Display Selection] - *CTL [0 or 1 / 1 / - ] 0: ACS, Colour, Black & White, Two Colour, Single colour 1: ACD, Full Colour, Black & White 001 Selects the color selection display on the LCD. 5801 [Memory Clear] NOTE : For more information, see “NOTE 1” following SP8-xxx table. 001 All Clear Resets all correction data for process control and all software counters, and returns all modes and adjustments to their default values. Use this SP only after replacing t he NVRAM, or after the copier has malfunctioned due to a damaged NVRAM. 002 Engine - - Clears the engine settings. 003 SCS - - Clears the system settings. IMH Memory Clr - - 004 Clears IMH data. DFU MCS - - 005 Clears MCS data. DFU 006 Copier Application - -
SM 5-237 B230/B237/D042 Service Tables Clears the copy application settings. Fax Application - - 007 Clears the fax application settings. Printer Application - - 008 Clears the printer application settings. Scanner Application - - 009 Clears the scanner application settings. Web Service/Network Application - - 010 Delete the netfile application management files and thumbnails, and initializes the job login ID. NCS - - 011 Initializes the system default and in terface settings (IP address also), SmartDeviceMonitor for Admin, WebStatusMonitor settings, and the TELNET settings. R-FAX - - 012 Initializes the job login ID, SmartDeviceMonitor for Admin, job history, and local storage file numbers. Clear DCS Settings - - 014 Initializes the DCS (Delivery Control Service) settings. Clear UCS Settings - - 015 Initializes the UCS (User Inform ation Control Service) settings. MIRS Setting - - 016 Initializes the MIRS (Machine Info rmation Report Service) settings. 017 CCS - -
B230/B237/D042 5-238 SM Initializes the CCS (Certification and Charge-control Service) settings. SRM Memory Clr - - 018 Initializes the SRM (System Resource Manager) settings. LCS - - 019 Initializes the LCS (Log Count Service) settings. WebUapl - 020 Initializes the WebUapl settings. [Free Run] 5802 Performs a free run on the copier engine. ƒ The machine starts free run in the same condition as the sequence of A4/LT, A3 or A4 SEF printing from the 1st or 2nd tray. Therefore, the correct paper should be loaded in the 1st tray or 2nd tray, but paper is not fed. ƒ The main switch has to be turned off and on after using the free run mode for a test. 001 TRAY1: A4LEF: FC - 002 TRAY2: A3: FC - 003 TRAY2: A4SEF: FC - - 5803 [Input Check] - See Input Check in this section. 5804 [Output Check] - See Output Check in this section. [SC Reset] 5810 Resets a type A service call condition.
SM 5-239 B230/B237/D042 Service Tables NOTE: Turn the main switch off and on after resetting the SC code. 001 Fusing SC Reset - - 5811 [Machine Serial] Machine Serial Number Display 002 Display *ENG Displays the machine serial number. 5812 [Service Tel. No. Setting] Service *CTL - 001 Sets the telephone number for a servic e representative. This number is printed on the Counter List, which can be printed with the user’s “Counter” menu. This can be up to 20 characters (both numbers and alphabetic characters can be input). Facsimile *CTL - 002 Sets the fax or telephone number for a service representative. This number is printed on the Counter List. This can be up to 20 characters (both numbers and alphabetic characters can be input). Supply *CTL - 003 Use this to input the telephone number of your supplier for consumables. Enter the number and press #. Operation *CTL - 004 Use this to input the telephone number of your sales agency. Enter the number and press #.
B230/B237/D042 5-240 SM 5816 [Remote Service] *CTL - I/F Setting 001 Selects the remote service setting. [0 to 2 / 2 / 1 /step] 0: Remote service off 1: CSS remote service on 2: NRS remote service on CE Call 002 Performs the CE Call at the st art or end of the service. [0 or 1 / 0 / 1 /step] 0: Start of the service 1: End of the service ƒ This SP is activated only when SP 5816-001 is set to “2”. Function Flag 003 Enables or disables the remote service function. [0 to 1 / 0 / 1 /step] 0: Disabled 1: Enabled Device Information Call Display Setting 006 Displays or does not display t he device information call content. [0 to 1 / 0 / 1 /step] 0: Not displayed 1: Displayed SSL Disable 007 Uses or does not use the RCG certif ication by SSL when calling the RCG. [0 to 1 / 0 / 1 /step] 0: Uses the RCG certification 1: Does no use the RCG certification 008 RCG Connect Timeout
SM 5-241 B230/B237/D042 Service Tables Specifies the connect timeout interval when calling the RCG. [1 to 90 / 10 / 1 second /step] RCG Write Timeout 009 Specifies the write timeout interval when calling the RCG. [1 to 100 / 60 / 1 second /step] RCG Read Timeout 010 Specifies the read timeout interval when calling the RCG. [1 to 100 / 60 / 1 second /step] Port 80 Enable - 011 Enables/disables access via port 80 to the SOAP method. [0 or 1 / 0 / – ] 0: Disabled 1: Enabled RCG – C Registed 021 This SP displays the Cumin installation end flag. 0: Installation not completed 1: Installation completed RCG – C Registed Detail 022 This SP displays the Cumin installation status. 0: Basil not registered 1: Basil registered 2: Device registered Connect Type (N/M) 023 This SP displays and select s the Cumin connection method. [0 or 1 / 0 / 1 /step 0: Internet connection 1: Dial-up connection 061 Cert. Expire Timing DFU Proximity of the expiration of the certification.
B230/B237/D042 5-242 SM 062 Use Proxy This SP setting determines if the proxy server is used when the machine communicates with the service center. Proxy Host 063 This SP sets the address of the proxy server used for communication between Cumin-N and the gateway. Use this SP to set up or display the customer proxy server address. The address is necessary to set up Cumin-N. ƒ The address display is limited to 128 characters. Characters beyond the 128 character are ignored. ƒ This address is customer informat ion and is not printed in the SMC report. Proxy Port Number 064 This SP sets the port number of t he proxy server used for communication between Cumin-N and the gateway. This setting is necessary to set up Cumin-N. ƒ This port number is customer info rmation and is not printed in the SMC report. Proxy User Name 065 This SP sets the HTTP pro xy certification user name. ƒ The length of the name is limited to 31 characters. Any character beyond the 31st char acter is ignored. ƒ This name is customer informati on and is not printed in the SMC report. Proxy Password 066 This SP sets the HTTP proxy certification password. ƒ The length of the password is limit ed to 31 characters. Any character beyond the 31st char acter is ignored.