SM 5-13 B230/B237/D042 Service Tables 054 Thick 2: FC: Simplex *ENG [120 to 180 / 175 / 1°C/step] 055 Thick 2: BW: Simplex *ENG [120 to 180 / 175 / 1°C/step] 056 OHP: FC *ENG [120 to 180 / 175 / 1°C/step] 057 OHP: BW *ENG [120 to 180 / 165 / 1°C/step] 058 Special 1: FC: Simplex *ENG [120 to 200 / 165 / 1°C/step] 060 Special 1: FC: Duplex *ENG [120 to 200 / 165 / 1°C/step] 062 Special 1: BW: Simplex *ENG [120 to 200 / 165 / 1°C/step] 064 Special 1: BW: Duplex *ENG [120 to 200 / 165 / 1°C/step] 066 Special 2: FC: Simplex *ENG [120 to 200 / 165 / 1°C/step] 068 Special 2: FC: Duplex *ENG [120 to 200 / 165 / 1°C/step] 070 Special 2: BW: Simplex *ENG [120 to 200 / 165 / 1°C/step] 072 Special 2: BW: Duplex *ENG [120 to 200 / 165 / 1°C/step] 074 Special 3: FC: Simplex *ENG [120 to 200 / 165 / 1°C/step] 076 Special 3: FC: Duplex *ENG [120 to 200 / 165 / 1°C/step] 078 Special 3: BW: Simplex *ENG [120 to 200 / 165 / 1°C/step] 080 Special 3: BW: Duplex *ENG [120 to 200 / 165 / 1°C/step] 082 Ta r g e t Te m p . A f t e r Ready *ENG [120 to 180 / 170 / 1°C/step] 083 Recovery Target Temp. *ENG [120 to 180 / 160 / 1°C/step] 084 Ta r g e t Te m p . A f t e r Recovery *ENG [120 to 180 / 170 / 1 °C/step] 085 Print Start: Offset *ENG Specifies the paper feed start temperature. This value is the offset temperature in relation to the target temperature for the ready condition.
B230/B237/D042 5-14 SM [0 to 30 / 10 / 1 °C/step] 089 Thick 3: FC: Simplex *ENG [120 to 180 / 180 / 1°C/step] 091 Thick 3: BW: Simplex *ENG [120 to 180 / 170 / 1°C/step] 109 Middle Thick: FC: Simplex *ENG [120 to 180 / 170 / 1°C/step] 110 Middle Thick: FC: Duplex *ENG [120 to 180 / 170 / 1°C/step] 111 Middle Thick: BW: Simplex *ENG [120 to 180 / 170 / 1°C/step] 112 Middle Thick: BW: Duplex *ENG [120 to 180 / 170 / 1°C/step] [Fusing Temperature Display] Fusing Temperature Display (Heating or Pressure) 11 0 6 Displays the current temperature of the heating and pressure rollers. 001 Fusing: Center - 002 Fusing: Ends - 003 Pressure - [–20 to 250 / - / 1 °C/step] The heating roller has two lamps. One heats the center of the heating roller and the other heats both ends of the heating roller. 11 0 9 [Fusing Nip Band Check] 001 Execute - Executes the ni p band measurement between fusing belt and pressure roller. If the nip band width is not 8 mm, and fusing is not good, replace the pressure roller or install a new fusing unit. Pre-Idling Time *ENG [0 to 120 / 0 / 1 sec/step] 002 Specifies the fusing rotation ti me before executing SP1109-001.
SM 5-15 B230/B237/D042 Service Tables Stop Time * ENG [5 to 30 / 10 / 1 sec/step] 003 Specifies the time fo r measuring the nip. 111 2 [Environmental Correction: Fusing] Temp.: Threshold: Low *ENG [10 to 23 / 17 / 1 °C/step] 001 Specifies the threshold temperatur e for low temperature condition. Temp.: Threshold: High *ENG [24 to 40 / 30 / 1 °C/step] 002 Specifies the threshold temperature for high temperature condition. Low Temp. Correction *ENG [0 to 15 / 5 / 1 °C/step] 003 Specifies the temperature correction for the heating roller. When the low temperature condition (specif ied with SP1112-001) is detected, the value of this SP is added to the heating roller temperature. High Temp. Correction *ENG [0 to 15 / 5 / 1 °C/step] 004 Specifies the temperature correction for the heating roller. When the high temperature condition (specif ied with SP1112-002) is detected, the value of this SP is subtracted from the heating roller temperature. 111 3 [Stand-by Time] After Ready *ENG [0 to 60 / 10 / 1 sec/step] 001 Specifies the interval from the ready mode to the stand-by mode. If the machine does not do any printing job for the time specified with this SP after the heating roller has reached t he ready temperature, the machine returns to the stand-by mode. 002 Recovery Target Temp. *ENG [0 to 60 / 10 / 1 sec/step] Not used After Recovery *ENG [0 to 60 / 10 / 1 sec/step] 003 Specifies the interval from the recovery to the stand-by mode. If the machine does not do any printing job for the time specified with this SP
B230/B237/D042 5-16 SM after the machine has recovered from the energy save mode, it returns to the stand-by mode. 111 4 [First Print Correction] Correction Temp. *ENG [0 to 30 / 10 / 1 °C/step] 001 Specifies the additional temperat ure for the first print job. This temperature is added to the heati ng roller for the time specified with SP1114-002. Operation Time *ENG [0 to 60 / 2 / 1 sec/step] 002 Specifies the time for adding the first print additional temperature, which is specified with SP1114-001. Shift Time *ENG [0 to 5 / 0 / 0.1 sec/step] 003 Specifies the start time for adding the first print additional temperature at 138 mm/s line speed. The machine starts to add the first print additional temperature when the time specified with this SP ha s passed after feeding paper. Shift Time: Half Speed *ENG [0 to 5 / 0 / 0.1 sec/step] 004 Specifies the start time for adding the first print additional temperature at 77 mm/s line speed. The machine starts to add the first print additional temperature when the time specified with this SP ha s passed after feeding paper. 111 5 [Stand-by Idling] Interval *ENG [1 to 240 / 60 / 1 min/step] 001 Specifies the interval between idling during stand-by mode. This idling during the stand-by m ode prevents the roller deformation. Idling Time *ENG [1 to 60 / 2 / 0.1 sec/step] 002 Specifies the length of each idli ng operation during stand-by mode.
SM 5-17 B230/B237/D042 Service Tables 003 Idling Speed *ENG [0 to 3 / 1 / 1 mm/sec /step] Not used 111 6 [Ends Temp. Correction] Center Temp. 1: 226– *ENG [–30 to 0 / 0 / 1 °C/step] 010 Specifies the temperature correction for the heating roller (center) when the paper width is 226 mm or more. The start time of this SP can be adjusted with SP1116-018. Ends Temp. 1: 226– *ENG [–30 to 0 / 0 / 1 °C/step] 011 Specifies the temperature correction for the heating roller (ends) when the paper width is 226 mm or more. The start time of this SP can be adjusted with SP1116-018. Center Temp. 2: 226– *ENG [–30 to 0 / 0 / 1 °C/step] 012 Specifies the temperature correction for the heating roller (center) when the paper width is 226 mm or more. The start time of this SP can be adjusted with SP1116-019. Ends Temp. 2: 226– *ENG [–30 to 0 / 0 / 1 °C/step] 013 Specifies the temperature correction for the heating roller (ends) when the paper width is 226 mm or more. The start time of this SP can be adjusted with SP1116-019. Center Temp. 3: –226 *ENG [–30 to 0 / –5 / 1 °C/step] 014 Specifies the temperature correction for the heating roller (center) when the paper width is less than 226 mm. The start time of this SP can be adjusted with SP1116-020. Ends Temp. 3: –226 *ENG [–30 to 0 / –5 / 1 °C/step] 015 Specifies the temperature correction for the heating roller (ends) when the paper width is less than 226 mm. The start time of this SP can be adjusted with SP1116-020. 016 Center Temp. 4: –226 *ENG [–30 to 0 / –5 / 1 °C/step]
B230/B237/D042 5-18 SM Specifies the temperature correction for the heating roller (center) when the paper width is less than 226 mm. The start time of this SP can be adjusted with SP1116-021. Ends Temp. 4: –226 *ENG [–30 to 0 / –10 / 1°C/step] 017 Specifies the temperature correction for the heating roller (ends) when the paper width is less than 226 mm. The start time of this SP can be adjusted with SP1116-021. Control Time 1: 226– *ENG [0 to 250 / 0 / 1 sec/step] 018 Specifies the start time of the tem perature correction that is set with SP1116-010 and -011. The temperature correction is added when t he time specified with this SP has passed after feeding the paper. Control Time 2: 226– *ENG [0 to 250 / 0 / 1 sec/step] 019 Specifies the start time of the tem perature correction that is set with SP1116-012 and -013. The temperature correction is added when t he time specified with this SP has passed after feeding the paper. Control Time 3: –226 *ENG [0 to 250 / 30 / 1 sec/step] 020 Specifies the start time of the tem perature correction that is set with SP1116-014 and -015. The temperature correction is added when t he time specified with this SP has passed after feeding the paper. Control Time 4: –226 *ENG [0 to 250 / 60 / 1 sec/step] 021 Specifies the start time of the tem perature correction that is set with SP1116-016 and -017. The temperature correction is added when t he time specified with this SP has passed after feeding the paper. 022 Center Temp. 1 Duplex: 226– *ENG [–30 to 0 / 0 / 1 °C/step]
SM 5-19 B230/B237/D042 Service Tables Specifies the temperature correction for the heating roller (center) when the paper width is 226 mm or more in duplex mode. The start time of this SP can be adjusted with SP1116-026. Ends Temp. 1 Duplex: 226– *ENG [–30 to 0 / 0 / 1 °C/step] 023 Specifies the temperature correction for the heating roller (ends) when the paper width is 226 mm or more in duplex mode. The start time of this SP can be adjusted with SP1116-026. Center Temp. 2 Duplex: 226– *ENG [–30 to 0 / 0 / 1 °C/step] 024 Specifies the temperature correction for the heating roller (center) when the paper width is 226 mm or more in duplex mode. The start time of this SP can be adjusted with SP1116-027. Ends Temp. 2 Duplex: 226– *ENG [–30 to 0 / 0 / 1 °C/step] 025 Specifies the temperature correction for the heating roller (ends) when the paper width is 226 mm or more in duplex mode. The start time of this SP can be adjusted with SP1116-027. Control Time 1 Duplex: 226– *ENG [0 to 250 / 0 / 1 sec/step] 026 Specifies the start time of the tem perature correction that is set with SP1116-022 and -023. The temperature correction is added when t he time specified with this SP has passed after feeding the paper. Control Time 2 Duplex: 226– *ENG [0 to 250 / 0 / 1 sec/step] 027 Specifies the start time of the tem perature correction that is set with SP1116-024 and -025. The temperature correction is added when t he time specified with this SP has passed after feeding the paper.
B230/B237/D042 5-20 SM 111 7 [Idling Time After Heater OFF] After Ready *ENG [0 to10 / 4 / 1 sec/step] DFU 001 Specifies the idling time without t he lamp on after reaching the ready temperature. After Job End *ENG [0 to10 / 4 / 1 sec/step] 002 Specifies the idling time without the lamp on after job end. This idling prevents the heating roller overheating after job end. 11 5 9 [Fusing Jam Detection] SC Display *ENG[0 or 1 / 0 / 1 /step] 0: Disable, 1: Enable 001 Enables or disables the fusi ng consecutive jam detection. If this SP is set to 1 (default: 0), SC559 occurs when the machine detects the paper jam three times consecutively at the fusing unit. 1801 [Motor Speed Adj.] FA 001 Registration: 77 *ENG 002 Registration: 138 *ENG 003 Registration: 150 *ENG [–4 to 4 / 0 / 0.05 %/step] 004 Bk PCU Drive: 154 *ENG [–4 to 4 / 0 / 0.01 %/step] Not used 005 Bk PCU Drive: 138 *ENG [–4 to 4 / 0.3 / 0.01 %/step] 006 Bk PCU Drive: 77 *ENG [–4 to 4 / 0.28 / 0.01 %/step] 007 MCY PCU Drive: 154 *ENG [–4 to 4 / 0 / 0.01 %/step] Not used 008 MCY PCU Drive: 138 *ENG [–4 to 4 / 0.3 / 0.01 %/step] 009 MCY PCU Drive: 77 *ENG [–4 to 4 / 0.28 / 0.01 %/step]
SM 5-21 B230/B237/D042 Service Tables 010 MCY Development: 154 *ENG [–4 to 4 / 0 / 0.01 %/step] Not used 011 MCY Development: 138 *ENG [–4 to 4 / 0 / 0.01 %/step] 012 MCY Development: 77 *ENG [–4 to 4 / 0 / 0.01 %/step] 013 Fusing: 154 *ENG [–4 to 4 / 0 / 0.01 %/step] Not used 014 Fusing: 138 *ENG 015 Fusing: 77 *ENG[–4 to 4 / 0.4 / 0.01 %/step] 016 Image Transfer: 154 *ENG [–4 to 4 / 0 / 0.01 %/step] Not used 017 Image Transfer: 138 *ENG [–4 to 4 / 0.3 / 0.01 %/step] 018 Image Transfer: 77 *ENG [–4 to 4 / 0.28 / 0.01 %/step] 043 Registration: 77: Thin *ENG 044 Registration: 77: Middle thick *ENG[–4 to 4 / 0 / 0.05 %/step] 045 Registration: 77: Thick 1 *ENG 046 Registration: 77: Thick 2 *ENG 047 Registration: 77: Thick 3 *ENG [–4 to 4 / –0.4 / 0.05 %/step] 048 Registration: 138: Thin *ENG 049 Registration: 138: Middle Thick *ENG[–4 to 4 / 0 / 0.05 %/step] 1901 [Recovery Temp. Ope. Time] 004 - *ENG [0 to 60 / 10 / 1 sec/step] Not used 1903 [Drive Current Setting] 001 Duplex Motor Clockwise *ENG 002 Duplex Motor *ENG[0 or 1 / 0 / 1 /step] 0: Large Current, 1: Small Current
B230/B237/D042 5-22 SM Counterclockwise 1907 [Paper Feed Timing Adj.] DFU 003 Feed Clutch OFF: Plain *ENG [–10 to 10 / 0 / 1 mm/step] 004 Feed Clutch ON: Plain *ENG [–10 to 10 / 0 / 1 mm/step] 005 Inverter Stop Position *ENG [–10 to 10 / 0 / 1 mm/step] 006 Exit Stop Position: 3rd Sheet *ENG [–10 to 10 / 0 / 1 mm/step] 011 Entrance Stop Position *ENG [–7 to 10 / 0 / 1 mm/step] 013 Feed Clutch OFF: Thick *ENG [–10 to 10 / 0 / 1 mm/step] 014 Feed Clutch ON: Thick *ENG [–10 to 10 / 0 / 1 mm/step] 015 Exit Stop Position: 1st/2nd Sheet *ENG [–10 to 10 / 0 / 1 mm/step] 016 By-pass Solenoid ON: Plain *ENG [–10 to 10 / 0 / 1 mm/step] 017 By-pass Solenoid ON: Thick *ENG [–10 to 10 / 0 / 1 mm/step] 1908 [Paper Bank Feed Timing Adj.] DFU 001 Paper Pre-Feed *ENG [0 or 1 / 0 / 1 /step] 002 Feed Solenoid ON: Plain *ENG [–10 to 40 / 0 / 2.5 mm/step] 003 Feed Solenoid ON: Thick *ENG [–10 to 40 / 0 / 2.5 mm/step] 004 Feed Clutch OFF: Plain *ENG [–10 to 10 / 0 / 1 mm/step] 005 Feed Clutch OFF: Thick *ENG [–10 to 10 / 0 / 1 mm/step] 006 Feed Clutch ON: Plain *ENG [–10 to 10 / 0 / 1 mm/step]