    							Bit Switches 
    SM 89 B786 
    B786 
    Fax Option 
    IP Fax Switch 03 [SP No. 1-111-004]  
    No.  FUNCTION  COMMENTS 
    0 Effective field limitation for G3 
    standard function information 
    0: OFF, 1: 4byte (DIS)  Limits the effective field for standard G3 
    function information. 
    1 
    Switching between G3 standard 
    and G3 non standard 
    0: Enable switching 
    1: G3 standard only  Enables/disables switching between G3 
    standard and G3 non-standard. 
    2  Not used. 
    Do not change this setting. 
    3 ECM frame size selection at 
    transmitting 
    0: 256byte, 1: 64byte  Selects the ECM frame size for sending. 
    4 DIS detection times for echo 
    prevention 
    0: 1 time, 1: 2 times  Sets the number of times for DIS to detect 
    echoes.  
    5 
    CTC transmission selection 
    0: PPRx1 
    1: PPRx4  When 0 is selected, the transmission 
    condition is decided by error frame numbers.
    When 1 is selected, the transmission 
    condition is based on the ITU-T method. 
    6 
    Shift down setting at receiving 
    negative code 
    0: OFF, 1: ON  Selects whether to shift down when negative 
    codes are received. 
    7 
    Not used   Do not change this setting. 
     
    IP Fax Switch 04 [SP No. 1-111-005]  
    No.  FUNCTION  COMMENTS 
    0 
    1 
    2 
    3 TCF error threshold 
    Sets the TCF error threshold level. 
    [00 to 0f] 
    The default is 1111 (0fH). 
    4-7 
    Not used   Do not change these settings. 
     
    IP Fax Switch 05 [SP No. 1-111-006]   
    No.  FUNCTION  COMMENTS 
    0-3 Modem bit rate setting for transmission 
    Sets the modem bit rate for transmission. The default is 0110 (14.4K bps).  
    						
    							Bit Switches 
    B786 90  SM 
    Bit 3  Bit 2  Bit 1  Bit 0   
    0 0  0 1 2400 bps 
    0 0  1 1 4800 bps 
    0 0  1 1 7200 bps 
    0 1  0 0 9600 bps 
    0 1  0 1 12.0 Kbps 
    0 1  1 0 14.4 Kbps 
    0 1  1 1 16.8 Kbps 
    1 0  0 0 19.2 Kbps 
    1 0  0 1 21.6 Kbps 
    1 0  1 0 24.0 Kbps 
    1 0  1 1 26.4 Kbps 
    1 1  0 0 28.8 Kbps 
    1 1  0 1 31.2 Kbps 
    1 1  1 0 33.6 Kbps 
    4-5 Modem setting for transmission 
    Sets the modem for transmission. 
    The default is 00 (V29). 
    Bit 5: 0, Bit 4: 0 = V29 
    Bit 5: 0, Bit 4: 1 = V17 
    Bit 5: 1, Bit 4: 0 = V34* 
    Bit 5: 1, Bit 4: 1 =
     Not used 
    *V34 is not supported for IP-Fax communication. 
    6-7  Not used   Do not change these settings. 
     
    IP Fax Switch 06 [SP No. 1-111-007]  
    No.  FUNCTION  COMMENTS 
    Modem bit rate setting for reception 
    Sets the modem bit rate for reception.  The default is 0110 (14.4K bps). 
    Bit 3  Bit 2   Bit 1  Bit 0   
    0 0  0 1 2400  bps 
    0 0  1 0 4800 bps 
    0 0  1 1 7200 bps 
    0-3 
    0 1  0 0 9600 bps  
    						
    							Bit Switches 
    SM 91 B786 
    B786 
    Fax Option 
    0 1  0 1 12.0  Kbps 
    0 1  1 0 14.4 Kbps 
    0 1  1 1 16.8 Kbps 
    1 0  0 0 19.2 Kbps 
    1 0  0 1 21.6 Kbps 
    1 0  1 0 24.0 Kbps 
    1 0  1 1 26.4 Kbps 
    1 1  0 0 28.8 Kbps 
    1 1  0 1 31.2 Kbps 
    1 1  1 0 33.6 Kbps 
            
    Modem setting for reception 
    Sets the modem type for reception. The default is 0100 (V27ter, V29, V17). 
    Bit 7  Bit 6   Bit 5  Bit 4   
    0 0  0 1 V27ter 
    0 0  1 0 V27ter,  V29 
    0 0  1 1 V27ter, V29, V33 
    (invalid) 
    0 
    1  0 0  V27ter, V29, V17 
    0 1  0 1  V27ter, V29, V17, 
    V34* 
    4-7 
    *V34 is not supported for IP-Fax communication. 
     IP Fax Switch 07 [SP No. 1-111-008]  
    No.  FUNCTION  COMMENTS 
    0 TSI information  
    0: Not added, 1: Added  Adds or does not add TSI information to 
    NSS(S). 
    1 DCN transmission setting at T1 
    timeout 
    0: Not transmitted, 1: Transmitted  Transmits or does not transmit DCN at T1 
    timeout. 
    2 
    Not used   Do not change this setting. 
    3 Hang up setting at DIS reception 
    disabled 
    0: No hang up  Sets whether the machine disconnects after 
    DIS reception.  
    						
    							Bit Switches 
    B786 92  SM 
    1: Hang up after transmitting DCN 
    4 Number of times for training  
    0: 1 time, 1: 2 times  Selects the number of times training is done 
    at the same bit rate. 
    5 
    Space CSI transmission setting at 
    no CSI registration 
    0: Not transmitted, 1: Transmitted  When 0 is selected, frame data is enabled. 
    When 1 is selected, the transmitted data is 
    all spaces. 
    6-7 
    Not used   Do not change these settings. 
     
    IP Fax Switch 08 [SP No. 1-111-009]  
    No.  FUNCTION  COMMENTS 
    0-1 T1 timer adjustment 
    Adjusts the T1 timer. 
    The default is 00 (35 seconds). 
    Bit 1: 0, Bit 0: 0 = 35 sec 
    Bit 1: 0, Bit 0: 1 = 40 sec 
    Bit 1: 1, Bit 0: 0 = 50 sec 
    Bit 1: 1, Bit 0: 1 =
     60 sec  - 
    2-3 
    T4 timer adjustment 
    Adjust the T4 timer. 
    The default is 00 (3 seconds). 
    Bit 3: 0, Bit 2: 0 = 3 sec 
    Bit 3: 0, Bit 2: 1 = 3.5 sec 
    Bit 3: 1, Bit 2: 0 = 4 sec 
    Bit 3: 1, Bit 2: 1 =
     5 sec  - 
    4-5 
    T0 timer adjustment  
    Bit 5: 0, Bit 4: 0 = 75 sec 
    Bit 5: 0, Bit 4: 1 = 120 sec 
    Bit 5: 1, Bit 4: 0 = 180 sec 
    Bit 5: 1, Bit 4: 1 =
     240 sec  Adjusts the fail safe timer. This timer sets the 
    interval between setup data transmission 
    and T.38 phase decision. 
    If your destination 
    return is late on the network or G3 fax return 
    is late, adjust the longer interval timer. 
    The default is 00 (75 seconds). 
    6-7  Not used   Do not change these settings. 
      
    						
    							NCU Parameters 
    SM 93 B786 
    B786 
    Fax Option 
    4.4 NCU PARAMETERS 
    The following tables give the RAM addresses  and the parameter calculation units that the 
    machine uses for ringing signal  detection and automatic dialing. The factory settings for 
    each country are also given. Most of these must be changed by RAM read/write (SP2-
    102), but some can be changed using NCU Parameter programming (SP2-103, 104 and 
    105); if SP2-103, 104 and 105 can be used, this  will be indicated in the Remarks column. 
    The RAM is programmed in hex code unless  (BCD) is included in the Unit column. 
     
    ƒ  The following addresses describe settings for the standard NCU. 
    ƒ  Change the fourth digit from “5” to “6” (e.g. 680500 to 680600) for the settings for 
    the first optional G3 interfac e unit and from “5” to “7” (e.g. 680700) for the settings 
    for the second optional G3 interface unit. 
    Address Function  
    Country/Area code for NCU parameters 
    Use the Hex value to program the count ry/area code directly into this 
    address, or use the decimal value  to program it using SP2-103-001 
    Country 
    /Area   Decimal
     Hex  Country
     
    /Area   Decimal
     Hex 
    France    00  00  USA    17  11 
    Germany    01  01  Asia    18  12 
    UK   02  02  Hong Kong  20  14 
    Italy    03  03  South Africa  21  15 
    Austria    04  04  Australia    22  16 
    Belgium    05  05  New Zealand 26  17 
    Denmark    06  06  Singapore    24  18 
    Finland    07  07  Malaysia    25  19 
    Ireland    08  08  China    26  1A 
    Norway    09  09  Taiwan    27  1B 
    Sweden    10  0A  Korea  28  1C 
    Switzerland    11  0B  Turkey  32  20 
    Portugal    12  0C  Greece    33  21 
    680500 
    Holland    13  0D  Hungary  34  22  
    						
    							NCU Parameters 
    B786 94  SM 
    Address Function 
    Spain    14  0E  Czech  35  23 
    Israel    15  0F  Poland  36  24 
     
    Address Function Unit Remarks 
    680501  Line current detection time  
    680502  Line current wait time  
    680503  Line current drop detect time  20 ms 
    Line current detection is 
    disabled. 
    Line current is not 
    detected if 680501 
    contains FF. 
    680504 
    PSTN dial tone frequency upper 
    limit (high byte) 
    680505 PSTN dial tone frequency upper 
    limit (low byte)  Hz (BCD) 
    If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680506 
    PSTN dial tone frequency lower 
    limit (high byte) 
    680507 PSTN dial tone frequency lower 
    limit (low byte)  Hz (BCD) 
    If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680508  PSTN dial tone detection time 
    680509  PSTN dial tone reset time (LOW) 
    68050A  PSTN dial tone reset time (HIGH) 
    68050B 
    PSTN dial tone continuous tone 
    time 
    68050C PSTN dial tone permissible drop 
    time  If 680508 contains 
    FF(H), the machine 
    pauses for the pause 
    time (address 68050D / 
    68050E). 
    Italy: See Note 2. 
    68050D  PSTN wait interval (LOW) 
    68050E  PSTN wait interval (HIGH) 
    20 ms 
    - 
    68050F  PSTN ring-back tone detection time 20 ms  Detection is disabled if 
    this contains FF. 
    680510 PSTN ring-back tone off detection 
    time  20 ms  - 
    680511 PSTN detection time for silent 
    period after ring-back tone detected 
    (LOW)  20 ms  - 
    680512 
    PSTN detection time for silent 
    period after ring-back tone detected 
    (HIGH)  20 ms  -  
    						
    							NCU Parameters 
    SM 95 B786 
    B786 
    Fax Option 
    Address Function  Unit Remarks 
    680513  PSTN busy tone frequency upper 
    limit (high byte) 
    680514 PSTN busy tone frequency upper 
    limit (low byte)  Hz (BCD) 
    If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680515 
    PSTN busy tone frequency lower 
    limit (high byte) 
    680516 PSTN busy tone frequency lower 
    limit (low byte)  Hz (BCD) 
    If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680517 
    PABX dial tone frequency upper 
    limit (high byte) 
    680518 PABX dial tone frequency upper 
    limit (low byte)  Hz (BCD) 
    If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680519 
    PABX dial tone frequency lower 
    limit (high byte) 
    68051A PABX dial tone frequency lower 
    limit (low byte)  Hz (BCD) 
    If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    68051B  PABX dial tone detection time 
    68051C  PABX dial tone reset time (LOW) 
    68051D  PABX dial tone reset time (HIGH) 
    68051E 
    PABX dial tone continuous tone 
    time 
    68051F PABX dial tone permissible drop 
    time  If 68051B contains FF, 
    the machine pauses for 
    the pause time (680520 
    / 680521). 
    680520  PABX wait interval (LOW) 
    680521  PABX wait interval (HIGH) 20 ms 
    - 
    680522  PABX ringback tone detection time  20 ms 
    680523 PABX ringback tone off detection 
    time  20 ms If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680524 
     PABX detection time for silent 
    period after ringback tone detected 
    (LOW)  20 ms 
    680525  PABX detection time for silent 
    period after ringback tone detected 
    (HIGH)  20 ms If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680526 
    PABX busy tone frequency upper 
    limit (high byte)  Hz (BCD) 
    If both addresses 
    contain FF(H), tone  
    						
    							NCU Parameters 
    B786 96  SM 
    Address Function Unit Remarks 
    680527  PABX busy tone frequency upper 
    limit (low byte)  detection is disabled. 
    680528 
    PABX busy tone frequency lower 
    limit (high byte) 
    680529 PABX busy tone frequency lower 
    limit (low byte)  Hz (BCD) 
    If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    68052A  Busy tone ON time: range 1 
    68052B  Busy tone OFF time: range 1 
    68052C  Busy tone ON time: range 2 
    68052D  Busy tone OFF time: range 2 
    68052E  Busy tone ON time: range 3  20 ms 
    68052F  Busy tone OFF time: range 3 
    680530  Busy tone ON time: range 4 
    680531  Busy tone OFF time: range 4 
    680532 
    Busy tone continuous tone 
    detection time  20 ms - 
    680533 
    Busy tone signal state time tolerance 
    for all ranges, and number of cycles 
    required for detection (a setting of 4  cycles means that ON-OFF-ON or OFF-
    ON-OFF must be detected twice). 
    Tolerance (±) 
    Bit 1: 0, Bit 0: 0 = 75% Bits 2  and 3 must always be kept at 0. 
    Bit 1: 0, Bit 0: 0 = 50% Bits 2  and 3 must always be kept at 0. 
    Bit 1: 0, Bit 0: 0 = 25% 
    Bit 1: 0, Bit 0: 0 = 12.5%  
    Bits 7, 6, 5, 4 - number of cy cles required for cadence detection 
    680534 International dial tone frequency 
    upper limit (high byte) 
    680535 International dial tone frequency 
    upper limit (low byte)  Hz (BCD) 
    If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680536 
    International dial tone frequency 
    lower limit (high byte) 
    680537 International dial tone frequency 
    lower limit (low byte)  Hz (BCD) 
    If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680538 
    International dial tone detection 
    time  
    680539 International dial tone reset time 
    (LOW)  20 ms 
    If 680538 contains FF, 
    the machine pauses for 
    the pause time (68053D 
    / 68053E).  
    						
    							NCU Parameters 
    SM 97 B786 
    B786 
    Fax Option 
    Address Function  Unit Remarks 
    68053A  International dial tone reset time 
    (HIGH) 
    68053B International dial
     tone continuous 
    tone time 
    68053C  International dial tone permissible 
    drop time  Belgium: See Note 2. 
    68053D 
    International dial wait interval 
    (LOW) 
    68053E International dial wait interval 
    (HIGH)  - 
    68053F 
    Country dial tone upper frequency 
    limit (HIGH) 
    680540 Country dial tone upper frequency 
    limit (LOW)  If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680541 
    Country dial tone lower frequency 
    limit (HIGH) 
    680542 Country dial tone lower frequency 
    limit (LOW)  Hz (BCD) 
    If both addresses 
    contain FF(H), tone 
    detection is disabled. 
    680543  Country dial tone detection time 
    680544  Country dial tone reset time (LOW) 
    680545  Country dial tone reset time (HIGH) 20 ms 
    If 680543 contains FF, 
    the machine pauses for 
    the pause time (680548 
    / 680549). 
    680546 
    Country dial t
    one continuous tone 
    time  - - 
    680547 
    Country dial tone permissible drop 
    time 
    680548  Country dial wait interval (LOW) 
    680549  Country dial wait interval (HIGH)  20 ms  - 
    68054A 
    Time between opening or closing 
    the DO relay and opening the OHDI 
    relay  1 ms See Notes 3, 6 and 8. 
    SP2-103-012 
    (parameter 11). 
    68054B  Break time for pulse dialing  1 ms  See Note 3.  
    SP2-103-013 
    (parameter 12). 
    68054C  Make time for pulse dialing  1 ms See Note 3.  
    SP2-103-014 
    (parameter 13).  
    						
    							NCU Parameters 
    B786 98  SM 
    Address Function Unit Remarks 
    68054D  Time between final OHDI relay 
    closure and DO relay opening or 
    closing  1 ms See Notes 3, 6 and 8.  
    SP2-103-015 
    (parameter 14). 
    This parameter is only 
    valid in Europe. 
    68054E 
    Minimum pause between dialed 
    digits (pulse dial mode)  See Note 3 and 8. SP2-
    103-016 (parameter 15).
    68054F 
    Time waited when a pause is 
    entered at the operation panel  20 ms 
    SP2-103-017 
    (parameter 16). See 
    Note 3. 
    680550  DTMF tone on time  SP2-103-018 
    (parameter 17). 
    680551  DTMF tone off time 1 ms 
    SP2-103-019 
    (parameter 18). 
    680552 Tone attenuation level of DTMF 
    signals while dialing  -N x 0.5  –
    3.5 dBm SP2-103-020 
    (parameter 19).  
    See Note 5. 
    680553 Tone attenuation value difference 
    between high frequency tone and 
    low frequency tone in DTMF 
    signals  -dBm x 0.5 SP2-103-021 
    (parameter 20). 
    The setting must be less 
    than –5dBm, and should 
    not exceed the setting at 
    680552h above. 
    See Note 5. 
    680554 
    PSTN: DTMF tone attenuation level 
    after dialling  -N x 0.5  –
    3.5 dBm SP2-103-022 
    (parameter 21). See 
    Note 5. 
    680555 
    ISDN: DTMF tone attenuation level 
    after dialling  -dBm x 0.5  See Note 5 
    680556 Not used 
    - Do not change the 
    settings. 
    680557 Time between 68054Dh (NCU 
    parameter 14) and 68054Eh (NCU 
    parameter 15)  1 ms This parameter takes 
    effect when the country 
    code is set to France. 
    680558 Not used 
    - Do not change the 
    setting. 
    680559 Grounding time (ground start 
    mode)  20 ms 
    The Gs relay is closed 
    for this interval. 
    68055A  Break time (flash start mode)  1 ms  The OHDI relay is open 
    for this interval.  
    						