    SM 1-69 B230/B237/D042 
    Installation 
    1.  Press the “User Tools/Counter” key. 
    2.  On the touch panel, press “System Settings”. 
    3.  Press “Interface Settings”. 
    4. Press “IEEE1394”. 
    5.  Press the following soft keys on the touch panel. Then set up the following 
    settings: 
    ƒ  “IP Address”: Set the IP Address and Subnet Mask. 
    ƒ  “IP over 1394”: Enable or disable this  setting as required. This setting enables IP 
    over 1394 as the default setting for the printing method. 
    ƒ  “SCSI Print”: Enable or disable this sett ing as required. This setting enables SCSI 
    Print as the default setting for the printing method. 
    ƒ  “Bi-directional SCSI Print”: Switch bi-d irectional printing on or off for SCSI print. 
    SP Mode Settings for IEEE 1394 
    The following SP commands can be set for IEEE 1394. 
    SP No. Name Function 
    5839 007  Cycle Master Enables or disables cycle ma
    ster function of the IEEE 
    1394 standard bus. 
    5839 008  BCR Mode  Sets the BCR (Broadcast Channel Register) setting for 
    the Auto Node operation for the standard IEEE1394 
    bus for when IRM is not in use. The following three 
    settings are available: “Standard,” “IRM Color Copy,” 
    and “Always Effective.” 
    5839 009 
    IRM 1394a 
    Check  Determines whether an IRM check for IEEE 1394a is 
    conducted for the Auto Node when IRM is not used. 
    5839 010  Unique ID 
    Enables the “Node_Unique_I
    d” setting for enumeration 
    on the standard IEEE 1394 bus. 
    5839 011  Logout  Determines how successive initiator login requests are 
    handled during login in for SBP-2. 
    5839 012  Login 
    Enables or disables exclusive login for SBP-2. 
    5839 013  Login MAX  Sets the limit for the number of logins for SBP-2. 
    Range: 1 to 62.  
    						
    							 
    B230/B237/D042 1-70 SM 
    1.20.6 IEEE1284 
    Installation Procedure 
     
    ƒ  Unplug the main machine power cord before you do the following 
    procedure.  
    You can only install one of the following netwo rk interfaces at a time: (IEEE 802.11b 
    (Wireless LAN), IEEE1284, Bluetooth). 
     
    1.  Remove the slot cover [A] from I/F Card Slot B (
     x 2). 
    2.  Install the interface board [B] (Knob-screw x 2) into I/F card slot B. 
    3.  Make sure that the machine can recognize the option (see ‘Check All 
    Connections’ at the end of this section).  
    						
    							  
    SM 1-71 B230/B237/D042 
    Installation 
    1.20.7  IEEE 802.11B (WIRELESS LAN) 
    Installation Procedure 
     
    ƒ  Unplug the main machine power cord before you do the following 
    procedure.  
    You can only install one of the following netwo rk interfaces at a time: (IEEE 802.11b 
    (Wireless LAN), IEEE1284, Bluetooth). 
     
    1.  Remove the slot cover [A] from I/F Card Slot B (
     x 2). 
    2.  Install the wireless LAN board (Knob-screw x 2) into I/F card slot B. 
    3.  Install the wireless LAN card [B] in th e wireless LAN board [C]. Make sure the 
    card label faces to the front of the machine. 
    4.  Attach the cover [D] to the wireless LAN card. 
    5.  Make sure that the machine can recognize the option (see ‘Check All  Connections’ at the end of this section). 
    You may have to move the machine  if the reception is not clear. 
    1.  Make sure that the machine is not lo cated near an appliance or any type of equipment 
    that generates str ong magnetic fields. 
    2.  Put the machine as close as  possible to the access point. 
    UP Mode Settings for Wireless LAN 
    Enter the UP mode. Then do the procedure below  to perform the initial interface settings for 
    IEEE 802.11b. These settings take effect  every time the machine is powered on. 
     
    ƒ  You cannot use the wirele ss LAN if you use Ethernet.  
    						
    							 
    B230/B237/D042 1-72 SM 
    1.  Press the “User Tools/Counter” key. 
    2.  On the touch panel, press “System Settings”. 
     
    ƒ  The Network I/F (default: Ethernet) must  be set for either Ethernet or wireless 
    LAN.  
    3.  Select “Interface Settings” 
     “Network” (tab)  “Network I/F Setting” 
    4.  Press “IEEE 802.11b”. Only the wireless LAN options show. 
    5.  Communication Mode. Select either “802.11 Ad hoc”, “Ad hoc” or 
    “Infrastructure”. 
    6.  SSID Setting. Enter the SSID setti ng. (The setting is case sensitive.) 
    7.  Channel. You need this setting when Ad Hoc Mode is selected.  Range: 1 to 14 (default: 11) 
     
    ƒ  The allowed range for the channel setti ngs may vary for different countries. 
    8.  WEP (Encryption) Setting. The WEP  (Wired Equivalent Privacy) setting is 
    designed to protect wireless data tran smission. The same WEP key is required 
    on the receiving side in order to unlock encoded data. There are 64 bit and 128 
    bit WEP keys. 
    WEP:  
    Selects “Active” or “Inacti ve”. (“Inactive” is default.) 
    Range of Allowed Settings: 
    64 bit  10 characters 
    128 bit26 characters 
    9.  Transmission Speed. Press the Next bu tton to show more settings. Then select 
    the transmission speed for the mode: Auto , 11 Mbps, 5.5 Mbps, 2 Mbps, 1 Mbps 
    (default: Auto). This setting should match the distance between the closest 
    machine or access point. This depends on which mode is selected.   
     
    ƒ  For the Ad Hoc Mode, this is the  distance between the machine and the 
    closest PC in the network. For the Infr astructure Mode, this is the distance 
    between the machine and the closest access point. 
    11 Mbps: 140 m (153 yd.) 
    5.5 Mbps: 200 m (219 yd.) 
    2 Mbps: 270 m (295 yd.) 
    1 Mbps: 400 m (437 yd.) 
    10.  Reboot the machine for these settings to take affect. 
    ⇒
    Rev. 05/2008 
    						
    							  
    SM 1-73 B230/B237/D042 
    Installation 
    SP Mode Settings for IEEE 802.11b Wireless LAN 
    The following SP commands and UP modes can be set for IEEE 802.11b   
    SP No.  Name  Function 
    5840 006  Channel MAX Sets the maximum range of 
    the channel settings for the 
    country. 
    5840 007  Channel MIN  Sets the minimum range of
     the channels settings 
    allowed for your country. 
    5840 011  WEP Key Select  Used to select the WEP key (Default: 00). 
    UP mode  Name  Function 
     SSID  Used to confirm the current SSID setting. 
    WEP Key Used to confirm 
    the current WEP 
    key setting.   
    WEP 
    Mode Used to show the 
    maximum length 
    of the string that 
    can be used for 
    the WEP Key 
    entry.   
     
    Rev. 05/2008
    ⇒ 
    						
    							 
    B230/B237/D042 1-74 SM 
    1.20.8 BLUETOOTH 
     
    ƒ  Unplug the main machine power cord before you do the following 
    procedure.  
    You can only install one of the following netwo rk interfaces at a time: (IEEE 802.11b 
    (Wireless LAN), IEEE1284, Bluetooth). 
     
    1.  Remove the slot cover [A] from I/F Card Slot B [A] (
     x 2). 
    2.  Install the Bluetooth board [B] (Kno b-screw x 2) into I/F card slot B. 
    3.  Insert the Bluetooth card [C] into the Bluetooth card adaptor [D]. . 
    4.  Attach the antenna cap [E] to the Bluetooth card. 
    5.  Install the Bluetooth card adaptor [D] into Bluetooth board [B]. 
    6.  Make sure that the machine can recognize the option (see ‘Check All  Connections’ at the end of this section).  
    						
    							  
    SM 1-75 B230/B237/D042 
    Installation 
    1.20.9  COPY DATA SECURITY UNIT 
     
    ƒ  Unplug the main machine power cord before you do the following 
    procedure.  
     
    ƒ  If you install this option, you  cannot use scanner or fax functions. 
     
    1.  Remove the rear cover [A] of the machine (
    x 7). 
     
    1.  Loosen the eight screws.   
    2.  Slide up the controller box cover [B], and then remove it. 
    3.  Attach the ICIB-2 (copy data security board) [C] to CN 504 on the BICU (
     x 2). 
    4.  Reassemble the machine.  
    						
    							 
    B230/B237/D042 1-76 SM 
    Installing Setting 
    1.  Plug in and turn on the main power switch. 
    2.  Go into the User Tools mode, and select System Settings > Administrator Tools 
    > Copy Data Security Option > On. 
    3.  Exit the User Tools. 
    4.  Check the operation. 
     
    ƒ  The machine will issue an SC165 error if  the machine is powered on with the 
    ICIB-2 removed and the Data Security  for Copying feature set to ON. 
    5.  Make sure that the machine can recognize the option (see ‘Check All  Connections’ at the end of this section). 
    1.20.10 DATA  OVERWRITE  SE CURITY UNIT TYPE D (B735) 
    Before You Begin the Procedure 
    1.  Make sure that the following settings ar e not at their factory default values: 
    ƒ  Supervisor login password 
    ƒ  Administrator login name 
    ƒ  Administrator login password 
    If any of these settings is at a factory def ault value, tell the customer these settings 
    must be changed before you do the installation procedure. 
    2.  Make sure that “Admin. Authentication” is ON.  [System Settings] – [Administrator Tools]  – [Administrator Authentication Management] 
    - [Admin. Authentication] 
    If this setting is OFF, tell the customer  this setting must be ON before you do the 
    installation procedure. 
    3.  Make sure that “Administrator Tools” is enabled (selected).  [System Settings] – [Administrator Tools]  – [Administrator Authentication Management] 
    - [Available Settings] 
    If this setting is disabled (not selected), te ll the customer this setting must be enabled 
    (selected) before you do the installation procedure. 
    4.  When you remove this option from the  machine, first set the setting to OFF 
    with the user tool before removing this board. If you forget to do this, then 
    SC165 will appear every time the machine is switched ON, and the machine 
    cannot be used. 
    ⇒ 
    Rev. 03/2007 
    						
    							  
    SM 1-77 B230/B237/D042 
    Installation 
    Seal Check and Removal 
     
     
    ƒ  You must check the box seals to make sure that they were not removed after 
    the items were sealed in the box at the factory before you do the installation.  
    1.  Check the box seals [A] on each corner of the box.  ƒ  Make sure that a tape is attached to each corner. 
    ƒ  The surfaces of the tapes must be blank. If you see “VOID” on the tapes, do not 
    install the components in the box. 
    2.  If the surfaces of the tapes do not sh ow “VOID”, remove them from the corners 
    of the box. 
    3.  You can see the “VOID” marks [B] when  you remove each seal. In this condition, 
    they cannot be attached to the box again.  
    						
    							 
    B230/B237/D042 1-78 SM 
    Installation Procedure 
     
    ƒ  Unplug the main machine power cord before you do the following 
    procedure.  
     
    ƒ  You must install the data overwrite security  unit in SD Card slot 2. However, the 
    Postscript option and the PictBridge option are  also installed in SD Card slot 2. 
    You must do the SD Card Appli move proc edure first if you have the postscript or 
    PictBridge option installed and you want to install the data overwrite security unit.   
     
    1.  Turn off the main power switch if the machine is turned on. 
    2.  Disconnect the network cable if the NIB is installed. 
    3.  Remove the slot cover [A] of SD card slot 2 (
     x 1). 
    4.  Turn the SD-card [B] label face to the rear of the machine. Then push it slowly 
    into slot 2 until you hear a click. 
    5.  Connect the network cable if the NIB option is installed. 
    6.  Turn on the main power switch. 
    7.  Go into the SP mode and push “EXECUTE” with SP5-878. 
    8.  Exit the SP mode and turn off the oper ation switch. Then turn off the main power 
    switch. 
    9.  Turn on the machine power. 
    10.  Do SP5990-005 (SP print  mode Diagnostic Report). 
    11.  Make sure the ROM number and firmware version in area [A] of the diagnostic  report are the same as those in area [B]. 
    ƒ [A]: “ROM Number/Firmware Version” –    “HDD Format Option” 
    ƒ  [B]: “Loading Program” – “GW2a_zoffy”  
    						