Home > Ricoh > All in One Printer > Ricoh Mp C3000 Service Manual

Ricoh Mp C3000 Service Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Ricoh Mp C3000 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 127 Ricoh manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1312
    							 
    SM 5-163 B230/B237/D042 
    Service 
    Tables 
    002 Latest Pixel: M  *ENG
    003 Latest Pixel: C  *ENG
    004 Latest Pixel: Y  *ENG[0 to 9999 / 
    0 / 1 cm
    2/step] 
    005-008  Displays the average coverage of each color for the Vtref correction.   
    Average S is defined when the numbe
    r of developed pages does not reach 
    the number specified with SP3251-017. 
    005 Average S: Bk  *ENG
    006 Average S: M  *ENG
    007 Average S: C *ENG
    008 Average S: Y  *ENG[0 to 100 / 
    5 / 0.01 %/step] 
    009-012  Displays the average coverage of each color for the Vtref correction.   
    Average M is defined when the numbe
    r of developed pages does not reach 
    the number specified with SP3251-018. 
    009 Average M: Bk  *ENG
    010 Average M: M  *ENG
    011 Average M: C *ENG
    012 Average M: Y  *ENG[0 to 100 / 
    5 / 0.01 %/step] 
    013-016  Displays the average coverage of each color for the Vtref correction.   
    Average L is defined when the numbe
    r of developed pages does not reach 
    the number specified with SP3-251-019. 
    013  Average L: Bk  *ENG
    014  Average L: M  *ENG
    015  Average L: C *ENG
    016 Average L: Y *ENG[0 to 100 / 
    5 / 0.01 %/step] 
    017-019  Adjusts the threshold for SP3-251-005 to -016.  
    						
    							 
    B230/B237/D042 5-164 SM 
    017  Total Page Setting: S  *ENG
    [1 to 100 / 10 / 1 sheet/step] 
    018  Total Page Setting: M  *ENG
    [1 to 500 / 10 / 1 sheet/step] 
    019  Total Page Setting: L  *ENG
    [1 to 999 / 50 / 1 sheet/step] 
    024-027  Displays the latest coverage ratio for each color. 
    024  Latest Coverage: Bk  *ENG
    025  Latest Coverage: M  *ENG
    026  Latest Coverage: C  *ENG
    027 Latest Coverage: Y  *ENG [0 to 100 / - / 0.01 %/step] 
     
    [ID Sensor Detection Value: Vofset]   
    3311 
    Displays the ID sensor (regular)  offset voltage for Vsg adjustments. 
    001 Voffset reg: Bk  *ENG
    002 Voffset reg: M  *ENG
    003 Voffset reg: C *ENG
    004 Voffset reg: Y  *ENG[0 to 5.5 / 
    - / 0.01 V/step] 
    005-007  Displays the ID sensor (diffusi on) offset voltage for Vsg adjustments. 
    005 Voffset dif: M *ENG
    006  Voffset dif: C *ENG
    007 Voffset dif: Y *ENG[0 to 5.5 / 
    - / 0.01 V/step] 
    008-010  Displays the ID sensor of fset voltage for Vsg adjustments. 
    008 Voffset TM (Front)  *ENG
    009 Voffset TM (Center)  *ENG
    010 Voffset TM (Rear)  *ENG [0 to 5.5 / 
    - / 0.01 V/step] 
      
    						
    							 
    SM 5-165 B230/B237/D042 
    Service 
    Tables 
    [ID Sensor Detection Value: Vsgave]   
    3313 
    Not used 
    001  Vsgave reg: Bk  *ENG
    002  Vsgave reg: M  *ENG
    003  Vsgave reg: C *ENG
    004 Vsgave reg: Y *ENG[0 to 5.5 / 
    - / 0.01 V/step] 
    005-007 Not used 
    005 Vsgave dif: M  *ENG
    006 Vsgave dif: C *ENG
    007 Vsgave dif: Y *ENG[0 to 5.5 / 
    - / 0.01 V/step] 
    008-010 Not used 
    008 Vsgave TM (Front)  *ENG
    009 Vsgave TM (Center)  *ENG
    010 Vsgave TM (Rear)  *ENG [0 to 5.5 / 
    - / 0.01 V/step] 
     
    3321   [Vsg Adjustment: Execution]   
    010 P/TM Sensor All  - Execute the ID sensor initialization setting 
    for all sensors 
     
    [Vsg Adjustment Result: Vsg]   
    3322 
    Displays the result value of t he Vsg adjustment for each sensor. 
    001  Vsg reg: Bk  *ENG
    002  Vsg reg: M  *ENG
    003  Vsg reg: C *ENG[0 to 5.5 / 
    - / 0.01 V/step]  
    						
    							 
    B230/B237/D042 5-166 SM 
    004 Vsg reg: Y *ENG
    005  Vsg dif: M  *ENG
    006  Vsg dif: C *ENG
    007 Vsg dif: Y *ENG[0 to 5.5 / 
    - / 0.01 V/step] 
    008 Vsg TM (Front)  *ENG
    009 Vsg TM (Center)  *ENG
    010 Vsg TM (Rear)  *ENG [0 to 5.5 / 
    - / 0.01 V/step] 
     
    3323   [Vsg Adjustment Result: Ifsg] DFU  
    001 Ifsg: Bk *ENG
    002 Ifsg: M  *ENG
    003 Ifsg: C *ENG
    004 Ifsg: Y *ENG[0 to 50 / 
    - / 0.1 mA/step] 
    005 Ifsg TM (Front)  *ENG
    006 Ifsg TM (Center)  *ENG
    007 Ifsg TM (Rear)  *ENG[0 to 50 / 
    - / 0.1 mA/step] 
     
    3324   [Vsg Adjustment: Set] DFU  
    002  Vofset Error Counter  *ENG
    003  Vofset Error Counter  *ENG [0 to 99 / 
    - / 0.1 time/step] 
    004 Vofset Threshold  *ENG
    [0 to 5 / 1 / 0.01 V/step] 
    005 Vsg Upper Threshold  *ENG
    [0 to 5 / 4.5 / 0.01 V/step] 
    006 Vsg Lower Threshold  *ENG
    [0 to 5 / 3.5 / 0.01 V/step] 
      
    						
    							 
    SM 5-167 B230/B237/D042 
    Service 
    Tables 
    [Vsg Adjustment Result]   
    3325  Displays the result 
    of the Vsg adjustment. 
    The displayed numbers mean the result  of each sensor (sensor for Front, 
    sensor for Bk, sensor for  Cyan, sensor for Center, s ensor for Magenta, sensor 
    for Yellow and sensor for Rear). 
    001 Latest  *ENG
    002 Latest 1 *ENG
    003 Latest 2 *ENG
    004 Latest 3 *ENG
    005 Latest 4 *ENG
    006 Latest 5 *ENG
    007 Latest 6 *ENG
    008 Latest 7 *ENG
    009 Latest 8 *ENG
    010 Latest 9 *ENG[ 1111111  t o  
    9999999 / 9999999 / 1 /step] 
    9: Unexpected error 
    3: Offset voltage error 
    2: Vsg adjustment value error 
    1: O.K 
     
    3361   [ID Sensor Sensitivity: Display] Not Used  
    001 K2K (Latest) *ENG
    002 K5K (Latest) *ENG
    003 K2M (Latest)  *ENG
    004 K5M (Latest) *ENG
    005 K2C (Latest) *ENG
    006 K5C (Latest) *ENG
    007 K2Y (Latest)  *ENG
    008 K5Y (Latest) *ENG[0 to 5 / - / 0.0001 /step]  
    						
    							 
    B230/B237/D042 5-168 SM 
     
    3362   [ID Sensor Sensitivity: Setting] DFU  
    001 K2: Upper *ENG
    [0 to 1 /  0.32 / 0.01 /step] 
    002 K2: Lower  *ENG
    [0 to 1 /  0.22 / 0.01 /step] 
    003 K5: Upper  *ENG
    [0 to 10 /  5 / 0.01 /step] 
    004 K5: Lower  *ENG
    [0 to 10 /  0.5 / 0.01 /step] 
    005 Kn: Lower  *ENG
    [0 to 1 /  0.1 / 0.01 /step] 
    006 Kn: Upper  *ENG
    [0 to 1 /  1 / 0.01 /step] 
    007  K5 Edit Point  *ENG
    [0 to 1 /  0.15 / 0.01 /step] 
    008 K5 Target Voltage  *ENG
    [0 to 5 / 1.63 / 0.01 V/step] 
    009 K5 Approximate Method  *ENG [0 to 1 / 
    1 / 1 /step] 
    0:Linear, 1: Curve 
    010  K2: Upper/Lower Limit 
    Coefficient 1  *ENG
    [0 to 1 /  0 / 0.01 /step] 
    011  K2: Upper Limit 
    Correction  *ENG
    [–0.2 to 0.4 /  0.07 / 0.01 /step] 
    012  K2: Lower Limit 
    Correction  *ENG
    [–0.2 to 0.4 /  –0.07 / 0.01 /step] 
    013  Diffusion Correction: M  *ENG
    014  Diffusion Correction: C  *ENG
    015 Diffusion Correction: Y  *ENG [0.75 to 1.35 / 
    1 / 0.01 /step] 
    016 K2: Check: M  *ENG
    017 K2: Check: C *ENG
    018 K2: Check: Y  *ENG[0 to 1 / 
    0.25 / 0.001 /step] 
      
    						
    							 
    SM 5-169 B230/B237/D042 
    Service 
    Tables 
    3363   [ID Pattern Timing Setting] DFU  
    001 Scan YCMBk *ENGAdjusts the detection timing for the process 
    control pattern. 
    [-500 to 500 / 
    13.7 / 1 mm/step] 
    002  Paper Transfer Release 
    Start  Tim e  *ENGAdjusts the timing when the paper transfer 
    unit is kept away from the image transfer 
    belt. 
    [0 to 2500 / 
    0 / 1 msec/step] 
    003 Delay Time  *ENGAdjusts the processing timing for the 
    process control pattern. 
    [0 to 2500 / 
    600 / 1 msec/step] 
    004 MUSIC Delay Time  *ENG Adjusts the processing timing for the 
    pattern that is used for the line position 
    adjustment. 
    [-2500 to 2500 / 
    300 / 1 msec/step] 
     
    3371   [M/A Calculation] DFU  
    001  Correction Coefficient: Bk *ENG
    [0.5 to 2.0 / 1.04 / 0.01 /step] 
    002  Correction Coefficient: M  *ENG
    [0.5 to 2.0 / 0.98 / 0.01 /step] 
    003  Correction Coefficient: C  *ENG
    [0.5 to 2.0 / 1.11 / 0.01 /step] 
    004 Correction Coefficient: Y  *ENG
    [0.5 to 2.0 / 0.91 / 0.01 /step] 
     
    [Fixed Supply Mode]  
    3401 
    Adjusts the toner supply rate in the fixed toner supply mode. 
    001  Fixed Rate: Bk  *ENG
    002  Fixed Rate: M  *ENG
    003  Fixed Rate: C *ENG[0 to 100 / 
    5 / 1 %/step] 
    These SPs are used only when SP3-044 is 
    set to 1.  
    						
    							 
    B230/B237/D042 5-170 SM 
    004 Fixed Rate: Y *ENG
     
    [Toner Supply Rate: Display]  
    3411 
    Displays the current toner supply rate. 
    001 Latest: Bk  *ENG
    002 Latest: M  *ENG
    003 Latest: C *ENG
    004 Latest: Y  *ENG[0 to 100 / 
    - / 1 %/step] 
     
    3421   [Toner Supply Range]  
    001 Upper Limit: Bk  *ENG
    002 Upper Limit: M  *ENG
    003 Upper Limit: C  *ENG
    004 Upper Limit: Y *ENGAdjusts the toner supply rate during 
    printing. 
    [0 to 100 / 
    100 / 1%/step] 
    005  Minimum Supply Time: 
    Bk  *ENG
    006  Minimum Supply Time: M  *ENG
    007  Minimum Supply Time: C  *ENG
    008  Minimum Supply Time: Y  *ENG Adjusts the minimum toner supply time. 
    [0 to 1000 / 
    0 / 1 msec/step] 
     
    3451   [Toner Supply Carry Over: Display] DFU  
    001 Bk *ENG
    002 M  *ENG
    003 C *ENG
    004 Y *ENG[0 to 10000 / 
    0 / 1 msec/step]  
    						
    							 
    SM 5-171 B230/B237/D042 
    Service 
    Tables 
     
    3452   [Toner Supply Carry Over: Setting] DFU  
    001 Maximum: Bk *ENG
    002 Maximum: M *ENG
    003 Maximum: C *ENG
    004 Maximum: Y *ENG[0 to 10000 / 
    1000 / 1 msec/step] 
     
    [Process Control Target M/A]  
    3501 
    Adjusts the target M/A. 
    001  Maximum M/A: Bk  *ENG
    002  Maximum M/A: M  *ENG
    003  Maximum M/A: C  *ENG [0 to 1 / 
    0.42 / 0.001 mg/cm
    2/step] 
    004 Maximum M/A: Y  *ENG
    [0 to 1 / 0.43 / 0.001 mg/cm2/step] 
     
    [Image Quality Adj. Counter: Display]  
    3510 
    Displays the total page counter for each adjustment mode. 
    001  Potential Control: BW  *ENG
    002  Potential Control: FC  *ENG
    003  Power ON: BW  *ENG
    004  Power ON: FC *ENG
    005 MUSIC: BW *ENG
    006 MUSIC: FC *ENG
    007 Vsg Adj. *ENG
    008 Charge AC Control  *ENG [0 to 2000 / 
    0 / 1 page/step] 
      
    						
    							 
    B230/B237/D042 5-172 SM 
    [Execution Interval: Setting] 
    3511 
    Adjusts the threshold fo r each adjustment mode. 
    001 Job End: Potential 
    Control: BW  *ENG
    [0 to 2000 /  250 / 1 page/step] 
    002  Job End: Potential 
    Control: FC  *ENG
    [0 to 2000 /  100 / 1 page/step] 
    003  Interrupt: Potential 
    Control: BW  *ENG
    [0 to 2000 /  500 / 1 page/step] 
    004  Interrupt: Potential 
    Control: FC  *ENG
    [0 to 2000 /  200 / 1 page/step] 
    005  Initial: Potential Control: 
    BW  *ENG
    [0 to 2000 /  200 / 1 page/step] 
    006  Initial: Potential Control: 
    FC  *ENG
    [0 to 2000 /  100 / 1 page/step] 
    007 Vsg Adj. Counter  *ENG
    [0 to 2000 / 500 / 1 page/step] 
    008  Charge AC  Control 
    Counter  *ENG
    [0 to 2000 /  500 / 1 page/step] 
    019 Environmental Correction *ENG [0 or 1 / 
    1 / 1 /step] 
    0: Not Correct (OFF), 1: Correct (ON) 
    020 Gamma Correction  *ENG [0 or 1 / 
    1 / 1 /step] 
    0: Not Correct (OFF), 1: Correct (ON) 
    021 Non-use Time Correction  *ENG [0 or 1 / 
    1 / 1 /step] 
    0: Not Correct (OFF), 1: Correct (ON) 
    022  Correction Coefficient 1: 
    JE: BW  *ENG
    [0 to 1 /  0.2 / 0.01 page/step] 
    023  Correction Coefficient 2: 
    JE: BW  *ENG
    [0 to 1 /  1 / 0.01/step] 
    024  Correction Coefficient 1:  *ENG
    [0 to 1 / 0.5 / 0.01/step]  
    						
    All Ricoh manuals Comments (0)