    of 1312
    							  
    SM 1-79 B230/B237/D042 
    Installation 
     
     
    Diagnostic Report:  “ROM No. / Firmware 
    Version” [A] “Loading Program” [B] 
    Data Overwrite Security 
    Unit   HDD Format Option: 
    B7355060 / 0.03 GW2a_zoffy: 
    B7355060 / 0.03 
     
    ƒ  The ROM number and firmware version number change when the firmware is 
    upgraded. However, the important thing is to make sure the numbers in [A] are 
    the same as the numbers in [B]. 
    ƒ  If the ROM numbers are not the same, or  the version numbers are not the same, 
    this means the unit was not installed correctly. 
    If this happens: 
    Make sure the unit type (Type D). 
    If they do not match: 
    1) Replace the NV-RAM  on the controller board. 
    2) Replace the “Data Overwrite Security  Unit” (SD card) with the correct type. 
    3) Do the installation procedure in th is procedure again, from Step 1. 
    12.  Go into the User Tools mode, and sel ect System Settings> Administrator Tools> 
    Auto Erase Memory Setting> On. 
    13.  Exit the User Tools mode. 
     
    14.  Check the display and make sure that the overwrite erase icon [A] shows. 
    15.  Make a Sample Copy. 
    16.  Check the overwrite erase icon. 
    ƒ  The icon [C] changes to [D] when  job data is stored in the HDD. 
    ƒ  The icon goes back to its usual shape [E] after this function has completed a data  overwriting in the HDD. 
    Rev. 03/2007
    ⇒ 
    						
    							 
    B230/B237/D042 1-80 SM 
    1.20.11 USB HOST INTERFACE 
     
    ƒ  Unplug the main machine power cord before you do the following 
    procedure.  
     
    1.  If the IEEE1394 unit is installed in I/F Card Slot A, remove it. 
    2.  Remove the slot cover [A] from I/F Card Slot A (
     x 2). 
    3.  Install the USB Host Interface [B] (Knob-screw x 2) into I/F card slot A. 
    4.  Make sure that the machine can recognize the option (see ‘Check All 
    Connections’ at the end of this section).  
    						
    							  
    SM 1-81 B230/B237/D042 
    Installation 
    1.20.12 PICTBRIDGE 
     
    ƒ  Unplug the main machine power cord before you do the following 
    procedure.  
     
    ƒ  You must install the PictBridge option in SD  Card slot 2. However, the Postscript 
    option and the data overwrite security unit opt ion are also installed in SD Card slot 
    2. You must do the SD Card Appli move procedure first if you have the postscript 
    or data overwrite security unit option installed and you want to install the 
    PictBridge unit. 
    ƒ  You must install the USB Host In terface when using the PictBridge unit. 
     
    1.  Remove the slot cover [A] from SD card slot 2 (
     x 1). 
    2.  Turn the SD-card [B] label face to the rear of the machine. Then push it slowly 
    into slot 2 until you hear a click. 
    3.  Attach the slot cover [A] (
     x 1). 
    4.  Make sure that the machine can recognize the option (see ‘Check All 
    Connections’ at the end of this section).  
    						
    							 
    B230/B237/D042 1-82 SM 
    1.20.13 BROWSER UNIT TYPE B 
     
    ƒ  Unplug the main machine power cord before you do the following 
    procedure.  
    SD card slot 3 is basically used only for serv ice maintenance. Do not leave an SD card in 
    slot 3 after installing an application. 
     
    1.  Remove the slot cover [A] from SD card slot 3 (
     x 1). 
    2.  Turn the SD-card [B] label face to the rear of the machine. Then push it slowly 
    into slot 3 until you hear a click. 
    3.  Plug in and turn on the main power switch. 
    4.  Push the User Tools key. 
    5.  Push the Login/ Logout key. 
    6.  Login with the administrator user name and password. 
    7.  Touch Extended Feature Settings on the LCD. 
    8.  Touch Install on the LCD. 
    9. Touch SD Card. 
    10.  Touch the Browser line. 
    11.  Under Install to: touch Machine HDD and touch Next. 
    12.  When you see Ready to Install, check th e information on the screen to confirm 
    your previous selection. 
    13.  Touch OK. You will see Installing..., and then Completed. 
    14.  Touch Exit to go back to the setting screen. 
    15. Touch Change Allocation. 
    16.  Touch the Browser line. 
    17.  Press one of the hard keys, which you want to use for the Browser Unit.  
    						
    							  
    SM 1-83 B230/B237/D042 
    Installation 
    18. Touch OK. 
    19.  Touch Exit twice to go back to the copy screen. 
    20.  Turn off the main power switch. 
    21.  Remove the SD card from slot 3. 
    22.  Attach the slot cover [A] (
    x 1). 
     
    1.20.14 VM CARD TYPE C (JAVA PLATFORM) 
     
    ƒ  Unplug the main machine power cord before you do the following 
    procedure.  
    Do not remove the SD card from sl ot 3 after installing the platform. 
     
    1.  With the power OFF and the machine  unplugged, remove the slot cover [A] from 
    SD card slot 2 or 3 (
     x 1). 
    2.  Insert the VM-Card Type C [B] label face to the rear of the machine. Then push it 
    slowly into slot 2 or 3 until you hear a click. 
    3.  Replace the sixth key-slot cover with the appropriate “Other function” key. 
    4.  Plug in and turn ON the main power switch. The installation of the Java VM  platform will start automatically. 
    IMPORTANT : DO NOT turn the main power OFF. Also, do not open any of the covers 
    or do any machine operations. This will damage the SD card. A damaged SD card 
    cannot be repaired.  
    ⇒
    Rev. 03/2007
    ⇒
    ⇒ 
    						
    							 
    B230/B237/D042 1-84 SM 
    5.  Wait five minutes, and then press the “Other function” key. You will hear two 
    beeps. z  If the screen does not change, this means  the installation is not finished yet. 
    Wait a few more minutes and then pre ss the “Other function” key again. 
    z   When the installation is finished, the following will be displayed: 
     
     
     
     
     
     
     
     
     
     
     
    6.  Set the heap size and stack size for  the application. (In User Tools/Extended 
    Features setting, see the Ad ministrator Tools tab.) 
    7.  Install the application using the installation procedure provided with the  application. 
     
    1.20.15 CHECK  AL L CONNECTIONS 
    23.  Plug in the power cord. Then turn on the main switch. 
    24.  Enter the printer user mode. Then print the configuration page. 
    User Tools > Printer Settings > List Test Print > Config. Page 
    All installed options are shown in  the “System Reference” column. 
     
     
    Rev. 03/2007
    ⇒ 
    						
    							  
    SM 1-85 B230/B237/D042 
    Installation 
    1.21 REMOTE COMMUNICATION GATE INSTALLATION 
    1.21.1 COMPONENT CHECK 
    No. Description Q’ty 
    1  Remote Comm. Gate Interface  1 
    2 Cover  1 
    3 Screw 3 
    1.21.2 INSTALLATION PROCEDURE 
    1.  Remove one cover bracket from I/F Card Slot B ( x 2) 
    2.  Install the modem board into the card slot for the device (  x 2). 
    3.  Check the following SP settings before  starting the installation flow chart 
    ƒ  SP5-816-150 (To Select the country) 
    ƒ  SP5-816-154 (To set the telephone number for outside connection) 
    ƒ  SP5-816-161 (To set the telephone number) 
    4.  Follow the Installation Flow Chart as shown on the next page with SP mode. 
     
    ⇒
    Rev. 03/2007 
    						
    							 
    B230/B237/D042 1-86 SM 
     
    Rev. 03/2007
      
    						
    							  
    SM 1-87 B230/B237/D042 
    Installation 
    1.22 FIERY E-3000 (B889) 
    1.22.1 ENVIRONMENT 
    1. Temperature Range:  5°C to 40°C (41°F to 104°F) 
    2.  Humidity Range:  10% to 90% RH 
    3.  Ambient Illumination:  Less than 1500 lux  (do not expose to direct sunlight 
    or strong light) 
    4.  Ambient Dust:  Less than 0.10 mg/m3 
    5.  If the place of installation is ai r-conditioned or heated, do not place the 
    machine where it will be: 
    1) Subjected to sudden temperature changes 
    2) Directly exposed to cool air from an air-conditioner 
    3) Directly exposed to heat from a heater 
    6.  Do not place the machine where it will be exposed to corrosive gases. 
    7.  Do not install the machine at any  location over 3,048 m (10,000 feet) above 
    sea level.   
    8.  Place the controller on a strong and level base. 
    9.  Do not place the machine where it  may be subjected to strong vibrations. 
    10. Do not connect the machine to  a power source shared with another 
    electrical appliance. 
    11. The machine can generate an electrom agnetic field, which could interfere 
    with radio or television reception. 
     
    1.22.2 MACHINE LEVEL 
    1.  Front to back:  Within ±5 ° (0.2) away from level 
    2.  Right to left:  Within ±5 ° (0.2) away from level 
     
    ⇒
    Rev. 04/2008 
    						
    							 
    B230/B237/D042 1-88 SM 
    1.22.3  MINIMUM SPACE REQUIREMENTS 
    Place the machine near the power source, providing clearance as shown. 
    You may place the E-3000 on the rear side of the large capacity tray or finisher 
    as shown in the illustration. 
     
     
    1.22.4 POWER REQUIREMENTS 
     
    1.  Insert firmly the plug in the outlet. 
    2.  Avoid using an outlet extension plug or cord. 
    3.  Ground the machine. Avoid using  a 3-prong adapter in a 2-hole ungrounded 
    outlet. 
    4.  Use the supplied AC power cord with this product. 
     
    1.  Input voltage level:  100 – 240V, 50-60Hz; 3A 
    2.  Do not put anything on the AC power cord. 
     
    G889I103.WMF
    Front Panel Back Panel
    100 mm
    100 mm
    100 mm
    100 mm
    Left Panel
    Right Panel
    G815I906.WMF
    Rev. 04/2008 
    						
    All Ricoh manuals Comments (0)