Dedicated Transmission Parameters SM 109 B786 B786 Fax Option 1: On 2 MMR Compression mode for e-mail attachments 0 : Off 1: On Switches MMR compression on and off for files attached to e-mails for sending. 3-6 Not used Do not change these settings. 7 Designates the bits to reference for compression method of e-mail attachments 0 : Registered (Bit 0 to 6) 1: No registration. The 0 selection (default) references the settings for Bits 00, 01, 02 above. The 1 selection ignores the selections of Bits 00, 01, 02. Switch 01 No FUNCTION COMMENTS 0 Original width of e-mail attachment: A4 0 : Off 1: On Sets the original width of the e-mail attachment as A4. 1 Original width of e-mail attachment: B4 0 : Off 1: On Sets the original width of the e-mail attachment as B4. 2 Original width of e-mail attachment: A3 0 : Off 1: On Sets the original width of the e-mail attachment as A3. 3-6 Not used Do not change these settings. 7 Designates the bits to reference for original size of e-mail attachments 0 : Registered (Bit 0 to 6) 1: No registration. The 0 selection (default) references the settings for Bits 00, 01, 02 above. The 1 selection ignores the selections of Bits 00, 01, 02. Switch 02 No FUNCTION COMMENTS 0 Line resolution of e-mail attachment: 200 x 100 0 : Off 1: On Sets the line resolution of the e-mail attachment as 200 x100. 1 Line resolution of e-mail Sets the line resolution of the e-mail attachment as
Dedicated Transmission Parameters B786 110 SM attachment: 200 x 200 0: Off 1: On 200 x 200. 2 Line resolution of e-mail attachment: 200 x 400 0 : Off 1: On Sets the line resolution of the e-mail attachment as 200 x 400. 3 Not used Do not change these settings. 4 Line resolution of e-mail attachment: 400 x 400 0 : Off 1: On Sets the line resolution of the e-mail attachment as 400 x 400. 5-6 Not used Do not change these settings. 7 Designates the bits to reference for original size of e-mail attachments 0 : Registered (Bit 0 to 6) 1: No registration. The 0 selection (default) references the settings for Bits 00, 01, 02, 04 above. The 1 selection ignores the selections of Bits 00, 01, 02, 04. Switch 03 - Not used (do not change the settings) Switch 04 No FUNCTION COMMENTS 0 Full mode address selection 0: Full mode address 1: No full mode (simple mode) If the other ends have the addresses, which have the full mode function flag (0), this machine determines them as full mode standard machines. ƒ This machine attaches the demand of reception confirmation to a message when transmitting. ƒ This machine updates t he reception capability to the address book when receiving. 1-7 Not used Do not change these settings. Switch 05 No FUNCTION COMMENTS 0 Directr transmission selection to SMTP server 0: ON 1: OFF Allows or does not allow t he direct transmission to SMTP server. 1-7 Not used Do not change these settings.
Dedicated Transmission Parameters S M 111 B 7 86 B786 Fax Option Switch 06 - Not used (do not change the settings) Switch 07 - Not used (do not change the settings) Switch 08 - Not used (do not change the settings) Switch 09 - Not used (do not change the settings)
Service RAM Addresses B786 112 SM 4.6 SERVICE RAM ADDRESSES ƒ Do not change the settings which are marked as “Not used” or “Read only.” 680001 to 680004(H) - ROM version (Read only) 680001(H) - Revision number (BCD) 680002(H) - Year (BCD) 680003(H) - Month (BCD) 680004(H) - Day (BCD) 680006 to 680015(H) - Machine’s serial number (16 digits - ASCII) 680018(H) - Total program checksum (low) 680019(H) - Total program checksum (high) 680020 to 68003F(H ) - System bit switches 680050 to 68005F(H) - Printer bit switches 680060 to 68007F(H) - Communication bit switches 680080 to 68008F(H) - G3 bit switches 680090 to 68009F(H) - G3-2 bit switches: Not used 6800A0 to 6800AF(H) - G3-3 bit switches: Not used 6800D0(H) - User parameter switch 00 (SWUER_00) : Not used 6800D1(H) - User parameter switch 01 (SWUSR_01) : Not used 6800D2(H) - User parameter switch 02 (SWUSR_02) Bit 0: Forwarding mark printing on forwar ded messages 0: Disabled, 1: Enabled Bit 1: Center mark printing on received copies (This switch is not printed on the user parameter list.) 0: Disabled, 1: Enabled Bit 2: Reception time printing (This switch is not printed on the user parameter list.) 0: Disabled, 1: Enabled Bit 3: TSI print on received me ssages 0: Disabled, 1: Enabled Bit 4: Checkered mark printing (This switch is not printed on the user parameter list.) 0: Disabled, 1: Enabled Bit 5: Not used Bit 6: Not used Bit 7: Not used 6800D3(H) - User parameter switch 03 (SWUSR_03: Automatic report printout)
Service RAM Addresses SM 113 B786 B786 Fax Option Bit 0: Transmission result report (m emory transmissions) 0: Off, 1: On Bit 1: Not used Bit 2: Memory storage report 0: Off, 1: On Bit 3: Polling reserve report (po lling reception) 0: Off, 1: On Bit 4: Polling result report (polli ng reception) 0: Off, 1: On Bit 5: Transmission result report (immediate transmissions) 0: Off, 1: On Bit 6: Not used Bit 7: Journal 0: Off, 1: On 6800D4(H) - User parameter switch 04 (SWUSR_04: Automatic report printout) Bit 0: Not used Bit 1: Automatic communication failure report and transfer result report output 0: Off, 1: On Bits 2 to 3: Not used Bit 4: Indicates the parties 0: Not indicated, 1: Indicated Bit 5: Include sender’s name on reports 0: Off, 1: On Bit 6: Not used Bit 7: Inclusion of a sample image on reports 0: Off, 1: On 6800D5(H) - User parameter switch 05 (SWUSR_05) Bit 0: Substitute reception when the base copier is in an SC condition 0: Enabled, 1: Disabled Bits 1 and 2: Condition for substitute rx when the machine cannot print messages (Paper end, toner end, jam, and during night mode) Bit 2: 0, Bit 1: 0 = The machine receives all the fax messages. Bit 2: 0, Bit 1: 1 = The machine rece ives the fax messages with RTI or CSI. Bit 2: 1, Bit 1: 0 = The machine receives the fax messages with the same ID code. Bit 2: 1, Bit 1: 1 = The machine does not receive anything. Bit 3: Not used Bit 4: Not used Bit 5: Just size printing 0: Off, 1: On Bit 6: Not used Bit 7: Add paper display when a casse tte is empty 0: Off, 1: On 6800D6(H) - User parameter switch 06 (SWUSR_06) : Not used 6800D7(H) - User parameter switch 07 (SWUSR_07) Bit 0 Ringing 0: Off, 1: On Bit1: Automatic answering message 0: Off, 1: On Bit 2: Parallel memory trans mission 0: Off, 1: On Bits 3 and 4: Not used
Service RAM Addresses B786 114 SM Bit 5: Remote control 0: Off, 1: On Bits 6 and 7: Not used 6800D8(H) - User parameter switch 08 (SWUSR_08) Bits 0 and 1: Not used. Bit 2: Authorized reception 0: Only faxes from senders whose RTIs/CSIs ar e specified for this feature are accepted. 1: Only faxes from senders whose RTIs/CSI s are not specified for this feature are accepted. Bits 3 to 7: Not used. 6800D9(H) - User parameter switch 09 (SWUSR_09) : Not used 6800DA(H) - User parameter switch 10 (SWUSR_0A) Bits 0 to 2: Not used Bit 3: Page reduction 0: Off, 1: On Bits 4 and 5: Not used Bit 6: Use both e-mail notificati on and printed reports to confir m the transmission results 0: Off, 1: On Bit 7: Not used 6800DB(H) - User parameter switch 11 (SWUSR_0B) Bits 0 and 1: Not used Bit 2: White original detection 0: Off, 1: On (alarm and alert message on the LCD) Bit 3: Receive rejection for 1300 Hz transmissi on 0: Off (receive), 1: On (not receive) Bit 5: Not used Bit 6: Printout of messages received while ac ting as a forwarding station 0: Off, 1: On Bit 7: Not used 6800DC(H) - User parameter switch 12 (SWUSR_0C) : Not used 6800DD(H) - User parameter switch 13 (SWUSR_0D) : Not used 6800DE(H) - User parameter switch 14 (SWUSR_0E) Bit 0: Message printout while the machine is in Night Printing mode 0: On, 1: Off Bit 1: Maximum document length detection 0: Double letter, 1: Longer than double-letter (well log) – up to 1,200 mm Bit 2: Not used Bit 3: Fax mode settings, such as resolution, before a mode key (Copy/Fax/Printer/Scanner) is pressed 0: Not cleared, 1: Cleared Bits 4 to 6: Not used Bit 7: Not used 6800DF(H) - User parameter switch 15 (SWUSR_0F)
Service RAM Addresses SM 115 B786 B786 Fax Option (This switch is not printed on the user parameter list.) Bits 0, 1 and 2: Cassette for fax printout Bit 2: 0, Bit 1: 0, Bit 0: 1 = 1st paper feed station Bit 2: 0, Bit 1: 1, Bit 0: 0 = 2nd paper feed station Bit 2: 0, Bit 1: 1, Bit 0: 1 = 3rd paper feed station Bit 2: 1, Bit 1: 0, Bit 0: 0 = 4th paper feed station Bit 2: 1, Bit 1: 0, Bit 0: 1 = LCT Other settings Not used Bits 3 and 4: Not used Bit 5: Using the cassette specified by bits 0, 1 and 2 above only 0: On, 1: Off Bits 6 and 7: Not used 6800E0(H) – User parameter switch 16 (SWUSR_10) (This switch is not printed on the user parameter list.) Bits 0 and 1: Not used Bit 2: Paper size selection priority for an A4 size fax message when A4/LT size paper is not available. 0: A3 has priority, 1: B4 has priority Bits 3 to 7: Not used 6800E1(H) – User parameter switch 17 (SWUSR_11) Bit 0: Not used Bit 1: Not used Bit 2: Inclusion of the “Add” button when a sequence of Quick/Speed dials is selected for broadcasting 0:Not needed, 1: Needed Bits 3 to 6: Not used Bit 7: Press “Start” key without an original when using the on hook dial or the external telephone, 0: displays “Cannot detect original size”. 1: Receives fax messages. 6800E2(H) - User parameter switch 18 (SWUSR_12) Bit 0: TTI date 0: Off, 1: On Bit 1: TTI sender 0: Off, 1: On Bit 2: TTI file number 0: Off, 1: On Bit 3: TTI page number 0: Off, 1: On Bits 4 to 6: Not used Bit 7: Japan only 6800E3(H) - User parameter switch 19 (SWUSR_13) Bit 0: Not used Bit 1: Journal format
Service RAM Addresses B786 116 SM 0: The Journal is separated into transmissions and receptions 1: The Journal is separated into G3-1, G3-2, and G3-3 communications Bit 2: Not used Bit 3: 90 ° image rotation during B5 portrait Tx (T his switch is not printed on the user parameter list.) 0: Off, 1: On Bit 4: Reduction of sample images on reports to 50% in the main scan and sub-scan directions. (This switch is not printed on the user parameter list.) 0: Technician adjustment (printer switch 0E bits 3 and 4), 1: 50% reduction Bit 5: Use of A5 size paper for reports (Thi s switch is not printed on the user parameter list.) 0: Off, 1: On Bits 6 and 7: Not used 6800E4(H) - User parameter switch 20 (SWUSR_14) Bit 0: Automatic printing of the LAN fax result report 0: Off, 1: On Bit 1: Not used. Bits 2 to 5: Store documents in memory whic h could not be printed from PC fax (LAN fax) driver Bit 5 Bit 4 Bit 3 Bit 2 Setting 0 0 0 0 0 min. 0 0 0 1 1 min. 1 1 1 0 14 min. 1 1 1 1 15 min. Bits 6 and 7: Not used. 6800E5(H) - User parameter switch 21 (SWUSR_15) Bit 0: Print results of sending reception not ice request message 0: Disabled (print only when error occurs), 1: Enabled Bit 1: Respond to e-mail reception acknow ledgment request 0: Disabled, 1: Enabled Bit 2: Not used Bit 3: File format for forwarded folders 0: TIFF, 1:PDF Bit 4: Transmit Journal by E-mail 0: Disabled, 1: Enabled Bit 5: Not used Bit 6: Network error display 0: Displayed, 1: Not displayed Bit 7: Transmit error mail notification 0: Enabled, 1: Disabled 6800E6(H) - User parameter switch 22 (SWUSR_16) (This switch is not printed on the user parameter list.)
Service RAM Addresses SM 117 B786 B786 Fax Option Bit 0: Dial tone detection (PST N 1) 0: Disabled, 1: Enabled Bits 1 to 7: Not used 6800E7(H) – User parameter switch 23 (SWUSR_17) : Not used 6800E8(H) - User parameter switch 24 (SWUSR_18) : Not used 6800E9(H) - User parameter switch 25 (SWUSR_19) Bit 0: Not used Bit 1: Reception mode switch timer 0: Of f, 1: On (switching Fax or Fax/Tel) Bit 2: Mode priority switch 0: Fax first, 1: Tel first Bit 3: Dial in function (Japan Only) Bit 4: RDS operation 0: Not acceptable, 1: Ac ceptable for the limit specified by system switch 03 ƒ This bit is only effective when RDS op eration can be selected by the user (see system switch 02). Bits 5 to 7: Not used 6800EA(H) and 6800EB(H) - User parameter switches 26 and 27 (SWUSR_1A and 1B) : Not used 6800EC(H) - User parameter switch 28(SWUSR_1C) Xxxxx 6800ED(H) - User parameter switch 29(SWUSR_1D) xxxxxx 6800EE(H) and 6800EF(H) - User parameter switches 30 and 31 (SWUSR_1E and 1F) : Not used 6800F0(H) - User parameter switch 32 (SWUSR_20) Bit 0: Quotation priority for a destination when there is no destination of the specified type 0: Paper output priority = Priority order: 1. IP-fax destination, 2. Fax Number, 3. E-mail address, 4. Folder 1: Electric putout order = Priority order: 1. E- mail address, 2. Folder, 3. IP-fax destination, 4. Fax number Bits 1 to 7: Not used 6800F1(H) - User parameter switch 33 (SWUSR_21): Not used 6800F2(H) - User parameter switch 34 (SWUSR_22) Bit 0: Gatekeeper server used with IP-Fax 0: Disabled, 1: Enabled Bit 1: SIP server used with IP -Fax 0: Disabled, 1: Enabled Bits 2 to 7: Not used 680100 to 68010F(H) - G4 Parameter Switches – Not used
Service RAM Addresses B786 118 SM 680110 to 68012F(H) - G4 Internal Switches – Not used 680130 to 68016F(H) - Service Switches 680170 to 68017F(H) - IFAX Switches 680180 to 68018F(H) - IP-FAX Switches 680190 to 6801AF(H) - Service station’s fax number (SP3-101) 6801B0 to 6801B9(H) - Own fax PABX extension number 6801BA to 6801C3(H) - Own fax number (PSTN) – Not used 6801C4 to 6801D7(H) - Own fax number (ISDN G4) – Not used 6801D8 to 6801E3(H) - The first subscriber number (ISDN G3) – Not used 6801E4 to 6801EF(H) - The second subscriber number (ISDN G3) – Not used 6801F0 to 6801FB(H) - The first subscriber number (ISDN G4) – Not used 6801FC to 680207(H) - The second subscriber number (ISDN G4) – Not used 680208 to 68021B(H) - PSTN-1 RTI (Max. 20 characters - ASCII) - See the following note. 68021C to 68022F(H) - PSTN-2 RTI (Max. 20 characters - ASCII) - Not used 680230 to 680246(H) - PSTN-3 RTI (Max. 20 characters - ASCII) - Not used 680247 to 680286(H) - TTI 1 (Max. 64 characters - ASCII) - See the following note. 680287 to 6802C6(H) - TTI 2 (Max. 64 characters - ASCII) - Not used 6802C7 to 680306(H) - TTI 3 (Max. 64 characters - ASCII) - Not used 680307 to 68031A(H) - PSTN-1 CSI (Max. 20 characters - ASCII) 68031B to 68032E(H) - PSTN-2 CSI (Max.20 characters - ASCII) - Not used 68032F to 680342(H) - PSTN-3 CSI (Max.20 characters - ASCII) - Not used 680343(H) - Number of PSTN-1 CSI characters (Hex) 680344(H) - Number of PSTN-2 CSI characters (Hex) - Not used 680345(H) Number of PSTN-3 CSI characters (Hex) - Not used ƒ If the number of characters is less th an the maximum (20 for RTI, 64 for TTI), add a stop code (00[H]) after the last character. 680380 to 680387(H) - Last power off time (Read only) 680380(H) - 01(H) - 24-hour clock, 00(H) - 12-hour clock (AM), 02(H) - 12-hour clock (PM) 680381(H) - Year (BCD) 680382(H) - Month (BCD) 680383(H) - Day (BCD) 680384(H) – Hour 680385(H) – Minute 680386(H) – Second 680387(H) - 00: Monday, 01: Tuesday , 02: Wednesday, /// , 06: Sunday