SM 5-173 B230/B237/D042 Service Tables JE: FC 025 Correction Coefficient 2: JE: FC *ENG [0 to 1 / 1 / 0.01/step] 026 Correction Coefficient 1: Interrupt: BW *ENG [0 to 1 / 0.1 / 0.01/step] 027 Correction Coefficient 2: Interrupt: BW *ENG [0 to 1 / 1 / 0.01/step] 028 Correction Coefficient 1: Interrupt: FC *ENG [0 to 1 / 0.25 / 0.01/step] 029 Correction Coefficient 2: Interrupt: FC *ENG [0 to 1 / 1 / 0.01/step] 030 Max. Number Correction Threshold *ENG [0 to 99 / 2 / 1/step] 031 Max. Number Correction Counter *ENG [0 to 255 / 0 / 1/step] [Image Quality Adj.: Interval] 3512 Adjusts the timing for execution of process control and line position adjustment. 001 During Job *ENG [0 to 100 / 30 / 1 page/step] 002 During Stand-by *ENG [0 to 100 / 10 / 1 minute/step] [PCU Motor Stop Time: Bk] 3513 Displays the last time t hat the PCU motors stopped. These are used for process control execution timing. 001 Year *ENG [0 to 99 / 0 / 1/step] 002 Month *ENG [1 to 12 / 1 / 1/step] 003 Date *ENG [1 to 31 / 1 / 1/step]
B230/B237/D042 5-174 SM 004 Hour *ENG [0 to 23 / 0 / 1/step] 005 Minute *ENG [0 to 59 / 0 / 1/step] [Environmental Display: Job End] 3514 Displays the environmental conditions for the last job. These are used for process control execution timing. 001 Temperature *ENG [-1280 to 1270 / 0 / 0.1°C/step] 002 Relative Humidity *ENG [0 to 1000 / - / 0.1%RH/step] 003 Absolute Humidity *ENG [0 to 1000 / - / 0.1 g/cm3/step] [Execution Interval: Display] 3515 Displays the current interval fo r process control execution. When the machine calculates the timing fo r process control, it uses a number of conditions. These are the results after considering all the conditions. 001 Job End: Potential Control: BW *ENG [0 to 2000 / – / 1 page/step] 002 Job End: Potential Control: FC *ENG [0 to 2000 / – / 1 page/step] 003 Interrupt: Potential Control: BW *ENG [0 to 2000 / – / 1 page/step] 004 Interrupt: Potential Control: FC *ENG [0 to 2000 / – / 1 page/step] [Refresh Mode] DFU 3516 While making prints with low coverage, t he developer is agitated with less toner consumption and the toner carrier attracti on tends to increase. This may cause low image density or poor transfer (white dots). To prevent this, the coagulated toner or overcharged toner has to be consumed by performing the refresh
SM 5-175 B230/B237/D042 Service Tables mode. 001 Dev. Motor Rotation: Display: Bk *ENG 002 Dev. Motor Rotation: Display: M *ENG 003 Dev. Motor Rotation: Display: C *ENG 004 Dev. Motor Rotation: Display: Y *ENG[0 to 1000 / 0 / 1 m/step] 005 Rotation Threshold *ENG [0 to 1000 / 1 / 1 m/step] 006 Pixel Coverage Sum: Bk *ENG 007 Pixel Coverage Sum: M *ENG 008 Pixel Coverage Sum: C *ENG 009 Pixel Coverage Sum: Y *ENG [0 to 65535 / 0 / 1 cm 2/step] 010 Required Area: Bk *ENG 011 Required Area: M *ENG 012 Required Area: C *ENG 013 Required Area: Y *ENG [0 to 65535 / 0 / 1 cm 2/step] 014 Refresh Threshold: Bk *ENG 015 Refresh Threshold: M *ENG 016 Refresh Threshold: C *ENG 017 Refresh Threshold: Y *ENG [0 to 255 / 14 / 1 cm 2/m/step] 018 Pattern Generation Number: Bk *ENG 019 Pattern Generation *ENG [0 to 255 / 0 / 1 time/step]
B230/B237/D042 5-176 SM Number: M 020 Pattern Generation Number: C *ENG 021 Pattern Generation Number: Y *ENG 022 Pattern Generation Number: Upper limit *ENG [0 to 255 / 0 / 1 time/step] 023 Toner Consumption Pattern Area *ENG [10 to 2550 / 320 / 10 cm2/step] 024 Supply Coefficient *ENG [0 to 2.55 / 1 / 0.01/step] 025 Job End Area Coefficient *ENG [0.1 to 25.5 / 1 / 0.1/step] 026 Job End Vb Coefficient *ENG [0 to 100 / 40 / 1%/step] 027 Job End Length *ENG [0 to 56 / 12 / 1mm/step] 028 Job End Supply *ENG [0 to 1 / 0.45 / 0.001 mg/cm2/step] [Blade damage prevention mode] 3517 Adjusts the threshold temperature for preventing the cleaning blade at the drum unit from being damaged. If the temperat ure is above this value, the drum reverses briefly at the end of the job to prevent the blade from flipping over. 001 Execution Temp. Threshold *ENG [0 to 50/ 40 / 1°C/step] 3518 [Image Quality Adj. Execution Flag] DFU 001 Toner End Recovery: Bk *ENG 002 Toner End Recovery: M *ENG 003 Toner End Recovery: C *ENG[0 or 1 / 0 / 1/step] 0: OFF. 1: ON
SM 5-177 B230/B237/D042 Service Tables 004 Toner End Recovery: Y *ENG 005 Vsg Adj. *ENG[0 or 1 / 0 / 1/step] 0: OFF. 1: ON 006 Developer Mixing *ENG [0 or 1 / 0 / 1/step] 0: OFF. 1: ON 007 Process Control *ENG [0 or 1 / 0 / 1/step] 0: OFF. 1: ON 008 MUSIC *ENG[0 or 1 / 0 / 1/step] 0: OFF. 1: ON 009 MUSIC (Skew Correction) *ENG [0 or 1 / 0 / 1/step] 0: OFF. 1: ON 010 Charge AC Control *ENG [0 or 1 / 0 / 1/step] 0: OFF. 1: ON 011 Blade Damage Prevention *ENG [0 or 1 / 0 / 1/step] 0: OFF. 1: ON [Toner End Prohibition Setting] 3519 Enables or disables each ad justment at toner near end. 001 Process Control *ENG 002 MUSIC *ENG 003 TC Adj. *ENG[0 or 1 / 0 / 1/step] 0: Permit (adjustment is done even toner near end condition) 1: Forbid (adjustment is not done at toner near end condition) [Initial Process Control Setting] 3522 Adjusts the threshold for the pr ocess control at power on. When the current condition has changed by more than the values of these SPs when compared with the conditions at the previous operation, the process control at power on is executed.
B230/B237/D042 5-178 SM 002 Non-use Time Setting *ENG [0 to 1440 / 360 / 1 minute/step] 003 Temperature Range *ENG [0 to 99 / 10 / 1°C/step] 004 Relative Humidity Range *ENG [0 to 99 / 50 / 1 %RH/step] 005 Absolute Humidity Range *ENG [0 to 99 / 6 / 1 g/m3/step] [Non-use Time Process Control Setting] 3531 Adjusts the threshold for the process control at stand-by. When the current condition has changed by more than the values of these SPs when compared with the conditions at the previous operation, the process control at stand-by is executed. 001 Non-use Time Setting *ENG [0 to 1440 / 360 / 1 minute/step] 002 Temperature Range *ENG [0 to 99 / 10 / 1°C/step] 003 Relative Humidity Range *ENG [0 to 99 / 50 / 1 %RH/step] 004 Absolute Humidity Range *ENG [0 to 99 / 6 / 1 g/m3/step] 005 Maximum Execution Number *ENGAdjusts the maximum execution time for the process control at stand-by. [0 to 99 / 10 / 1 time/step] 3611 [Development Gamma: Display/Set] 001 Bk (Current) *ENG 002 M (Current) *ENG 003 C (Current) *ENG 004 Y (Current) *ENGDisplays the current development gamma for each color. [0 to 5 / - / 0.01 mg/cm 2/kV /step] 005 Bk (Target Display) *ENG 006 M (Target Display) *ENG Displays the target development gamma for each color. [0 to 5 / 0.85 / 0.01 mg/cm2/kV /step]
SM 5-179 B230/B237/D042 Service Tables 007 C (Target Display) *ENG 008 Y (Target Display) *ENG Displays the target development gamma for each color. [0 to 5 / 0.8 / 0.01 mg/cm2/kV /step] 009 Bk (Standard Target Set) *ENG Displays the standard target development gamma for each color. [0 to 5 / 0.9 / 0.01 mg/cm 2/kV /step] 010 M (Standard Target Set) *ENG 011 C (Standard Target Set) *ENG 012 Y (Standard Target Set) *ENG [0 to 5 / 0.8 / 0.01 mg/cm 2/kV /step] 013 Environmental Correction *ENG Turns on or off the environmental correction for target development gamma. [0 or 1 / 1 / - ] 0: Not Correct, 1: Correct [Vk Display] 3612 Displays Vk for each color. 001 Bk *ENG 002 M *ENG 003 C *ENG 004 Y *ENG[-300 to 300 / - / 1 V/step] [Development DC Control: Display] Plain: 138 mm/sec, Thick 2 and Fin: 77 mm/sec 3621 Displays the development DC bias adjust ed with the process control for each line speed and color. 001 Plain: Bk *ENG 002 Plain: M *ENG[0 to 700 / 550 / 1 -V/step]
B230/B237/D042 5-180 SM 003 Plain: C *ENG 004 Plain: Y *ENG 009 Thick 2 & FINE: Bk *ENG 010 Thick 2 & FINE: M *ENG 011 Thick 2 & FINE: C *ENG 012 Thick 2 & FINE: Y *ENG [0 to 700 / 550 / 1 -V/step] [Charge DC Control: Display] Plain: 138 mm/sec, Thick 2 and Fin: 77 mm/sec 3631 Displays the charge DC volt age adjusted with the process control for each line speed and color. 001 Plain: Bk *ENG 002 Plain: M *ENG 003 Plain: C *ENG 004 Plain: Y *ENG[0 to 2000 / 690 / 1 -V/step] 009 Thick 2 & FINE: Bk *ENG 010 Thick 2 & FINE: M *ENG 011 Thick 2 & FINE: C *ENG 012 Thick 2 & FINE: Y *ENG [0 to 2000 / 690 / 1 -V/step] [Charge AC Control: Display] Plain: 138 mm/sec, Thick 2 and Fin: 77 mm/sec 3641 Displays the charge AC voltage adjust ed with the process control for each color. 001 Plain: Bk *ENG [0 to 3 / 1.75 / 0.01 kV/step]
SM 5-181 B230/B237/D042 Service Tables 002 Plain: M *ENG 003 Plain: C *ENG 004 Plain: Y *ENG [LD Power Control: Display] Plain: 138 mm/sec, Thick 2 and Fin: 77 mm/sec 3651 Displays the LD power adjusted for each environment. 001 Plain: Bk *ENG 002 Plain: M *ENG 003 Plain: C *ENG 004 Plain: Y *ENG[0 to 200 / 100 / 1 %/step] 009 Thick 2 & FINE: Bk *ENG 010 Thick 2 & FINE: M *ENG 011 Thick 2 & FINE: C *ENG 012 Thick 2 & FINE: Y *ENG [0 to 200 / 100 / 1 %/step] [HST Concentration Control: Set] TD Sensor: Toner Concentration Control Setting 3710 Selects the toner concentration control method by HST memory, which is in the TD sensor. 001 Control Method: Selection *ENG [0 or 1 / 1 / - ] 0: Not Use, 1: Use [HST Concentration Control: Bk] 3711 Displays the factory settings of the black PCU. 001 Vcnt *ENG [0 to 5 / 4 / 0.1 V/step]
B230/B237/D042 5-182 SM 002 Vt *ENG [0 to 5 / 2.5 / 0.1 V/step] 003 Sensitivity: HL *ENG [0 to 5 / 2.5 / 0.1 V/step] 004 Sensitivity: HM *ENG [0 to 5 / 1.3 / 0.1 V/step] 005 Sensitivity: ML *ENG [0 to 5 / 1.2 / 0.1 V/step] 006 Set Detection *ENG [0 to 5 / 1 / 0.1 V/step] 007 Without Developer *ENG [0 to 5 / 1.2 / 0.1 V/step] 008 With Developer *ENG [0 to 5 / 1.3 / 0.1 V/step] 009 Serial Number 1 *ENG 010 Serial Number 2 *ENG [0 to 255 / - / 1 V/step] 011 Adjustment: Vt *ENG [0 to 5 / 3 / 0.1 V/step] 012 Adjustment: Vtref *ENG [0 to 5 / 3 / 0.1 V/step] 013 Adjustment: Vtcnt *ENG [0 to 5 / 4 / 0.01 V/step] 014 Adjustment: Gamma *ENG [0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] 015 Adjustment: Vcnt Result *ENG [0 to 9 / 9 / 1 /step] [HST Concentration Control: M] 3712 Displays the factory settings of the magenta PCU. 001 Vcnt *ENG [0 to 5 / 4 / 0.1 V/step] 002 Vt *ENG [0 to 5 / 2.5 / 0.1 V/step] 003 Sensitivity: HL *ENG [0 to 5 / 2.5 / 0.1 V/step] 004 Sensitivity: HM *ENG [0 to 5 / 1.3 / 0.1 V/step] 005 Sensitivity: ML *ENG [0 to 5 / 1.2 / 0.1 V/step] 006 Set Detection *ENG [0 to 5 / 1 / 0.1 V/step] 007 Without Developer *ENG [0 to 5 / 1.2 / 0.1 V/step]