Cabinet installationWall-Mounting the CabinetWall-Mounting the Cabinet Guidelines Installation CAUTION:1Always turn the power switch OFF before beginning installation *The DBS 824 is shipped with the cover installed to protect components Before wall-mounting the cabinet, remove the cover lHandle the cabinet carefully to avoid damage 1Remove the two screws from the front cover (see Figure 3-1) 2Take the front cover off by pulling it from the bottom and lifting it up Figure 3-1 Cover removal Issued 3/l /95DBS 824-l O-3003-3
Wall-Mounting the CabinetCabinet installation3Install two screws in the wall studs 10 7/8’ apart as shown in Figure 3 2 The screws are used to attach the mounting slots to the wall The screws should protrude from the wall j/16 in wall-mountina 4Hang the cabinet on the wall by placing the mounting openings over the screws 5Tighten the screws to secure the cabinet. 6Install a mounting screw through the lower slot in the cabinet as shown in Figure 3-2 3-4DES 824-l O-300Issued 3/l /95
Cabinet InstallationGrounding Grounding Guidelinesl Before grounding the DBS 824 read the “Lightning Protection/ Grounding requirements beginning on page l-4l The ground cable must be at least 18 AWGl Resistance to ground must be 10 Ohms or less installation 1Attach the ground cable to the ground screw on the front of the power SUPPlY 2Connect the ground cable to the building ground Figure 3-3Cabinet mound screw G rot&dScrewPower Supply issued 3/l/95DBS 824-l O-3003-5
Card InstallationCabinet InstallationCard Installation Guidelines CAUTION:1 Before handling printed circuit cards, discharge static electricity by grounding yourself Static electricity can damage components Turn off the power before installing cards Installing cards with the power on can damage components lInstall the cards in the following order - 208 EXP in left slot for trunks 5 and 6 and extension ports 9 to 16 208 EXP in 2nd slot from left for trunks 7 and 8 and extension ports 17 to 24 (The second 208 EXP card can only be used with the CPC-M card ) - CPC (See additional information following) - MFR (8 DTMF circuits) in AUX slot lInstall cards only in their dedicated slots The slot type is marked on the cabinet directly above each slot3-6 DBS 824-l O-300issued 3/l /95
Cabinet InstallationCard InstallationCPC and MFRU Optionsl Before installing the CPC card determine if the DBS 824 will be used as a KSU or PBX To use as a PBX cut Strap 53 on the CPC Cutting this strap allows use of pooled trunks as opposed to line appearances Figure 3-4 CPC strap 53 I CPC-S and CPC-Ml Before installing a CPC-M card, determine if the optional MFRU (2 DTMF) Circuit Card is to be installed (VB-4243 1) If used, attach the MFRU’ to the CPC Circuit Card as shown below Figure 3-5 MFRll circuit card attachment tn CPC ADJUSTMENT :RIJ Note: Use VRl (also labeled DRT for DISA Ring Tone) to adjust the volume for DISA internal ringing Issued 3/l 195DBS 824-l O-3003-7
Card InstallationCabinet InstallationInstallation 1With the lettering on the card pointed up, position the card within the slot guides (See Figure 3-6 ) 2Hold the card on the top and bottom edges with both hands and carefully push the card into the slot 3When the connector at the far end of the card touches the corresponding connector on the backplane, press the card in until it is firmly seated Fi 3-8 DBS 824-l O-300Issued 3/l /95
Labmet I nsrarlatronMatrefy BacKupBattery Backup Guidelinesl The DBS 824 uses two 1Zvolt batteries to maintain system operation during power failures or outages The battery backup package for the DBS 824 is VB-43 130l The backup batteries are connected in a series circuit, using cables provided with the KSUl With maximum traffic the backup batteries will last up to 40 minutes for a fully equipped DBS 824l The backup batteries should be replaced about every 3 years issued 3/l /95 DBS 824-l O-3003-9
Battery BackupCabinet InstallationInstallation Fil 1Place one battery in the top tray of the battery compartment, the other battery in the b&tom tray- Bat I II//l-l II ? ‘ II rl IBattery 208208 CPC AUX Ill I I I I I e I0 10I 2Connect the positive cable (red) to the + terminal of the top battery 3Connect the connecting cable (white) to the - terminal of the top battery 4Connect the connecting cable (white) from the top battery to the + terminal on the bottom battery 5Connect the negative cable (blue) to the - terminal of the bottom battery 3-10DBS 824- 1 O-300Issued 3/l /95
Cabinet Installation System Initialization System Initialization1Confirm that the DBS 824 power switch is OFF 2Plug the power cord into a dedicated 120V 15 amp AC wall outlet. Note: A surge protector should be installed on the power cord 3Set SW1 on the CPC card to RAM CLEARFigure 3 8 CPC memnrv clear switch__. _ - _ -_ - ._.- ____., ----- - ---~Status LED PowerSwitchCAUTION:Some early CPC cards have RAM HOLD and RAM CLEAR reversedCheck the silk screen Programming 0 Power Supply- 4Turn the power switch on As the system loads, the Status LED lamp on the Cl% card flashes 5Once the Status LED lamp on the CPC card stops flashing, set SW1 on the CPC to HOLD issued 3/l I95 DBS 824-l O-3003-11
Chapter 4. Trunks and Lines This chapter describes trunk and line installation Some peripheral equipment also requires uunk and/or line interfaces (door phones or power failure units for example) See Chapter 5 for instructions on connecting peripheral equipment through trunks or lines Issued 3/l /95 DBS 824-l O-3004-l