Panasonic Dbs 824 Instructions Manual
Have a look at the manual Panasonic Dbs 824 Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Maximum Dialed Digits For TRS Types 3-6FF7 Maximum Dialed Digits For TRS Types 3-6 Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FF7 l# 3# (l-15)# DescriptionThe maximum number of dialed digits on trunks assigned TRS types 3-6 can be set from 15 to 29, or it can be unlimited Programming IFF7 1# 3## (l-15)# tMaximum Number of Digits That Can Be Dialed Note: The default setting is ** (unlimited)To change the setting to a limited number of digits, enter 1-15 (see the following table for values)To revert to the **default, press FM l# 3# CONF Table 7-2Maximum number of dialed digits for TRS types 3-6Setting 1Maximum Number of Digits15 216 317 418 519 6 20 721 822 923 1024 1125 1226 1327 1428 15297-8 DBS 824-l O-400issued 3/l /95
FF73-Digit Toll Restriction For TRS Types 2-6 3-Digit Toll Restriction For TRS Types 2-6 Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FF7 l# (4-lO)# (0 or l)# DescriptionUse this program to restrict dialing of special 3-digit numbers (211-811) on trunks assigned TRS types 2-6(“911” is permitted in all cases ) Programming FF7 l#(/O)# (0 jr l)# Special NumbersO=Permit 4=211l=Restrict 5=311 6==411 7=511 8=611 9=711 lo=811 Issued 3/l /95DBS 824-l O-4007-9
7-Digit Toll Restriction For TRS Types 2-6FF7 7-Digit Toll Restriction For TRS Types 2-6 Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FR l# (li-15)# (0 or l)# DescriptionUse this program to restrict dialing of specified 7-digit numbers on trunks assigned TRS types 2-6If this feature is enabled (default setting), the system checks the number dialed against a table of restricted 7-digit numbers (see “Special 7-Digit Table For TRS Types 2-6” on page 7-21) Programming FF7715)# (0 jr I)#TRS Types O=Does not check the 7-digit table ll=TRS type 2l=Checks the 7-digit table 12=TRS type 3 13=TRS type 4 14=TRS type 5 15=TRS type 6 NotesAnalysis of Final DigitsSeven-digit toll restriction considers the last seven digits dialed, so that permitted area codes can be denied access to specific telephone numbers, such as 555-1212 7-10DBS 824-l O-400Issued 3/l /95
FF7Dialing Plan Switch Dialing Plan Switch Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FR l# 16# (0 or l)# DescriptionThis address allows you to choose between the new North American Numbering Plan (NANP) and the old dialing plan Selecting the new NANP dialing plan provides greater flexibility for “exceptions to the rule”, by applying/removing toll restriction to/from individual extensions, and to dialed area codes, offke codes and country codesSpecific differences between the dialing plans are listed in the table belowSome of the FF7 addresses in this chapter apply only to the new NANP dialing plan, this is noted in the explanations for these addresses Other FM addresses apply to both dialing plans, but the value of their settingsdiffers depending on the dialing plan selected -- this too is noted in the explanations of these addresses ProgrammingI O=Old. dialing planl=New NANP dialing plan Table 7-3Differences between old and new dialing plans SubjectOffice CodesOld Plan NNX-XxXx New (NANP) PlanNxx-XxXx Long-Distance Calls NO/lx-NNX-XXXXlax-Nxx-XxXxEqual Access Code Format 10xXx1OlXXXXInternational Numbers 9 digits in length15 digits in length (N=digits 2 thru 9X=digits 0 thru 9) Related ProgrammingAll Toll Restriction Addresses (FF7) Issued 3/l /95DBS 824-l O-4007-11
Operator AccessFF7 Operator Access Software VersionCPC-S and CPC-M, Version 1 0 and higher AddressFF7 l# 17# (ExtPort)# (0 or l)# DescriptionThis Operator Access switch works only if the system is programmed to use the new NANP dialing plan (FF7 l# 16# l#)Also, this switch applies only to TRS types 2-6 (TRS types 0 and 1 do not allow outbound dialing, TRS type 7 allows all dialing) Use this address to block extension(s) from being able to access a trunk and dialing “O”, “OO”, “1OXXXO” or “1OlXXXXO” to reach an operatorThiswould prevent a user from being able to circumvent a TRS restriction by asking the operator to place a long-distance call If this switch is set to “Restrict” (default) and an extension user accesses a trunk and dials the operator, the system will wait 6 seconds before automatically disconnecting the call, if the user dials additional digits within 6 seconds, the system will check other switches (if programmed) to allow or restrict the call, such as “International Calling On Extensions” (FF7 l# lS#),“7-Digit Toll Restriction” (FF7 l# ll-15#), etc Programming IIFF7 l# 17# (1-16 or l-24)# (0 or l)# f4Extension Port O=Restrict operator callsCPC-S 1-16 l=Permit operator calls CPC-M, l-24 Related ProgrammingDialing Plan SwitchFF7 l# 16# (0 or l)#Equal Access Code Format FF7 l# 20# (0 or l)# 7-12 DBS 824-l O-400 Issued 3/l /95
FF7International Calling on Extensions International Calling on Extensions Software Version CPC-S and CPC-M, Version 1 0 and higher AddressFF7 l# 18## (ExtPort)# (0 or l)# DescriptionThis address applies only to systems programmed to use the new NANP dialing plan (FF7 l# 16#)It also applies only to TRS types 3-6 (TRS types O-2 do not allow international dialing, TRS type 7 allows all dialing) Use this address to allow or restrict international calling on individual extension(s) that are “exceptions to the rule”When an extension attempts an overseas call (trunk access + 01 or 011) on a trunk assigned TRS type 3-6, thesystem checks the setting in this address (default=restrict call)However, if this address is set to ‘ l”, the system checks the “International Calling For TRS Types 3-6” (FF7 l# l#) to see if the dialed country code should be checked against the Country Code Table (FF7 l# 19#) before allowing the callIf so, and if the dialed country code is included in the table, the call is allowed ProgrammingFF7 l# 18# (l-16 orl-24)# (0 or l)# ft Extension PortO=RestrictCPC-S 1-16l=Check the International CPC-M. l-24Calls Switch (FF7 l# l#) Related ProgrammingInternational Calling For TRS Types 3-6 FF7 l# l# (0 or l)#Dialing Plan SwitchFF7 l# 16# (0 or l>#Country Code Table FF7 1# 19# (Table)+! (Code)++ NotesRestticted callsIf the system determines the call is restricted during any stage of the process, it sends a busy tone to the user and displays “Restricted” on the phone Interaction with TRS tVpesThe “International Calling on Extensions” setting is not checked for TRS types O-2 or 7International calls are always restricted for TRS types O-2, and always allowed for type 7 Issued 3/l /95DBS 824-l O-4007-13
Country Code TableFF7 Country Code Table Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FR I# 19# (Table)# (Code)# DescriptionThis address applies only to systems programmed to use the new NANP dialing plan (FF7 I# 16#)It also applies only to TRS types 3-6 (TRS types O-2 do not allow international dialing TRS type 7 allows all dialing) In this address, the DBS 824 system provides a Country Code Table of up to 10 allowable country codes for placing international calls Each defined country code can be 1 to 3 digits long, and can include wild-card characters When a phone user accesses a trunk assigned TRS type 3-6 and then dials 01 or 0 11, the system first checks the international calling restriction (if any) assigned to that extension (in FF7 l# 18#)The DBS 824 then checks the system-wide international calling restriction (in FF7 l# l#) to see if international calling is allowed, or if the Country Code Table should be checked firstIf so, and if the country code is included in the table, the call is allowedIf the country code is not included in the table, the user will hear a busy tone and “Restricted” will be displayed on the phone ProgrammingFF7 1# 19# (l;O)# (0$9)# Table EntryCountry Code Entry Related ProgrammingDialing Plan SwitchFF7 l# 16# (0 or l)# NotesInternational Calling on Extensions FF7 l# 18# (ExtPort)# (0 or l)##International Calling For TRS Types 3-6 FF7 l# l# (0 or l)#Short Country CodesWhen country codes of less than 3 digits are entered, the system will allow any country code that begins with that number or numbersFor example, an entry of “9” allows all two- and three-digit country codes beginning with “9 ”Likewise, an entry of “26” allows all three-digit country codes beginning with “26 ”Digit RestictionThe system will not accept country codes that begin with “1” (this is reserved for U S calls) 7-l 4 DBS 824-l O-400 Issued 3/l /95
FF7Equal Access Code Format Equal Access Code Format Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FF7 l# 20# (0 or l)# DescriptionThis program address determines the dialing format that will be recognized by the DBS 824 for accessing a preferred interexchange carrier This address applies only to outgoing calls that are subject to toll restriction, and to DBS 824 systems that are programmed to use the new NANP dialing plan (see program address FF7 l# 16#)Under the old dialing plan, callers can dial 10xXx to reach their preferred interexchange carrier Within this dial sequence, the “XXX” indicates the carrier identification code (CIC) In the new North American Numbering Plan, the preferred carrier format is being changed to 101xXxX (the CIC code is expanded to 4 digits, and “10”is replaced with “101”) ProgrammingFF7 l# 20# (0 or l)# t O=Old Format (10XxX)l=New Format (1OlXXXX) Related ProgrammingDialing Plan Switch FF7 l# 16# (0 or l)# NotesAllowing Both CZC Formats During Transition PeriodThe public network is currently providing a transition period during which both preferred-carrier formats are recognized for choosing the preferred carrier Likewise, the DBS 824 system will also allow both formats, as long as the extension or dialed number does not have any toll restrictions assigned to it, and the system is programmed to use the new NANP dialing plan issued 3/l /95DBS 824-l O-400 7-15
Office Code Restriction Table For TRS Types 2-6FF7 Office Code Restriction Table For TRS Types 2-6 Sofhtvare Version CPC-S and CPC-M, Version 1 0 and higherAddress FR 1# 21# (l-lO)# (000-999)# DescriptionThis address applies only to systems programmed to use the new NANP dialing plan (FM l# 16#)This Office Code Restriction Table allows up to 10 office codes to be restricted system-wide for all trunks assigned TRS types 2-6 The system willcheck this table before checking the individual office code(s) assigned to individual TRS type(s) in FF7 3# These office codes are not tied to any area codesTherefore, whenever one of these office codes is dialed, it is restricted regardless of the area code Applications for this feature include 555,950, and 976 calls ProgrammingFF7 I# 21# (11lO)# (0001999)# ftOffice Code l-10 Office Code To Be Restricted 7-l 6 DBS 824-l O-400 Issued 3/l /95
FF7Area Code Table For TRS Types 3-6 Area Code Table For TRS Types 3-6 Sofhnrare VersionCPC-S and CPC-M, Version 1 0 and higherAddress IT7 2# (3-6)# (000-999)# (0 or l)# DescriptionUse this program to set area code dialing restrictions based on the TRS type assigned to a trunk Callers accessing a trunk assigned to TRS types 3-6 are allowed or denied access to specific area codes according to the settings in this program Programming IFF7 2# (3-6)# (000-999)# (0 or l)# i’ t t TRS Type (3-6)Area CodeO=Permit dialing l=Restrict dialing Note: The default for TRS types 3 and 4 is “1 ” The default for TRS tvues 5 and 6 is “0 ” Related ProgrammingSystem Installation Area Code FFl 2# l# 17# (0 or l)# Day TRS Types O-7 for TrunksFF7 7# (ExtPort)# (Trunk)# (0-7)# Night TRS Types O-7 for TrunksFF7 8# (ExtPort)# (Trunk)++ (0-7)# Issued 3/l /95DBS 824-l O-400 7-l 7