    							FFlCO-to-CO Talk Mode Control
    CO-to-CO Talk Mode Control
    Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
    FFl 2# l# 38## (0 or l)#
    DescriptionUse this address to determine whether the DBS 824 system will use an
    internal conference circuit for trunk-to-trunk conference calls or whether it
    will connect the trunks directlyThe CO-to-CO Talk mode is entered via the Call Forward-Outside feature or
    the DISA Outgoing functionIf an audio loop-back problem occurs when
    trunks are connected directly, reset this program address to “Use a conference
    circuit”
    Programming
    1
    FFl 2# l# 38## (0 or l)#
    t
    O=Connect the trunks directly (Default)
    1 =Use a conference circuit.
    Related ProgrammingAutomatic DISA Callers
    FFl 2# 8# (l-lO)# (PhoneNo )#Unsupervised Conference Timer 
    FFl 3# 9# (0-15)#
    Unsupervised Trunk ConferenceFF2 (Trunk)# 16# (0 or l)#Unsupervised ConferenceFF3 
    (ExtPort)# 13# (0 or l)#
    NotesLimihdion On Availability Of Conference Citcuii?sThe system can support
    up to three conference circuits at a timeIf this programming address is set to
    “1” (use a conference circuit), and a fourth CO-to-CO call is attempted while
    three other conference calls are currently in progress, the system will connect
    the trunks in the fourth call directly to each other
    Issued 3/l/95DBS 824-10-400Page1-43 
    						
    							Parity Check (SMDR)FFl
    SMDR Data (Serial Port CNl)
    Parity Check (SMDR)
    Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
    FFl 2# 2# l# (0 or l)##
    DescriptionThis program determines whether the DBS 824 uses parity checking over
    serial port 
    CNl, which is normally dedicated for SMDR
    If this address is set to “on,” use 
    FFl 2# 2# 2# (0 or l># to select even or odd
    PetY
    Programming
    I
    I
    FFl 2# 2# l# (0 or l)#
    f
    O=Turns off the parity check
    l=Turns on the parity check
    Related ProgrammingOdd/Even Parity (SMDR) 
    FFl 2# 2# 2# (0 or l)#
    NotesChecking Communications ParametersBe sure to properly set all
    communication programming addresses when modifying any single address
    valueCommunication parameters for SMDR are set with addresses 
    FF12#
    2# 1 through 9#Page l-44
    DBS 824-l O-400Issued 3/l 195 
    						
    							FFlOdd/Even Parity (SMDR)
    Odd/Even Parity (SMDR)
    Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
    FFl 2# 2# 2# (0 or l)##
    DescriptionIf the parity check for SMDR serial port CNl has been set (FF12# 2# l#),
    this option determines whether the check is based on an even count or an odd
    count.
    Programming
    11
    FFl 2# 2# 2# (0 or l)#
    t
    O--odd parityl=Even parity
    NotesChecking Communications ParametersBe sure to properly set all
    communication programming addresses when modifying any single address
    value
    Communication parameters for SMDR are set with addressesFFl2#
    2# 1 through 9#Issued 
    3/l/95DBS 824-l O-400Page 1-45 
    						
    							Baud Rate (SMDR)FFl
    Baud Rate (SMDR)
    Software Version
    CPC-S and CPC-M, Version 1 0 and higherAddress 
    FFl 2# 2# 3# (l-4)#
    DescriptionThe data transmission speeds between SMDR serial port CNl and peripheral
    equipment can be set from 300 bits per second to 9600 bits per second
    Programming
    FFl 2W 2# 3## (54)#
    f
    1=300 bps
    2=1200 bps
    3=2400 bps
    4=9600 bps
    NotesChecking Communications ParametersBe sure to properly set all
    communication programming addresses when modifying any 
    single address
    valueCommunication parameters for SMDR are set with addresses 
    FFl 2#
    2# 1 through 9#
    Page 1-46DES 824-l O-400issued 3/l 195 
    						
    							FFlStop Bit Lenqth (SMDR)
    Stop Bit Length (SMDR)
    Software VersionCPGS and CPC-M, Version 1 0 and higherAddress 
    FFl 2# 2# 4## (l-3)#
    DescriptionThis program sets the length of the stop-bit parameter for transmitted data
    over SMDR serial port 
    CNl
    Proghmming
    FFl 2# 2# 4## (1 to 3)#
    t
    l=l bit
    2=I 5 bits
    3=2 bits
    NotesChecking Communications ParametersBe sure to properly set all
    communication programming addresses when modifying any single address
    valueCommunication parameters for SMDR are set with addresses WI 2#
    2# 1 through Y#
    Issued 3/l/95DBS 824-10-400Page 1-47 
    						
    							Data Length (SMDR)FFl
    Data Length (SMDR)
    Software VerskdPC=S and CPC-M, Version 1 0 and higherAddress 
    FFl 2# 2# 5# (3 or 4)#
    DescriptionThis program sets the length of the transmitted data string at 7 or 8 bits, over
    SMDR serial port 
    CNl
    Programming
    II
    FFl 2# 2# 5## (3 or 4)#
    t
    3=7 bits
    4=8 bits
    NotesChecking Communicaticins ParametersBe sure to properly set all
    communication programming addresses when modifying any single address
    valueCommunication parameters for SMDR are set with addresses 
    FF1 2#
    2#1through9#Page l-48
    DBS 824- 1 O-400Issued 3/l 195 
    						
    							FFlSMDR Serial Port Flow Control (XON / XOFF)
    SMDR Serial Port Flow Control (XON / XOFF)
    Software Version
    CPC-S and CPC-M, Version 1 0 and higherAddress 
    FFl 2# 2# 6# (0 or l)#
    DescriptionUse this address to determine whether the DBS 824 system will control the
    flow of data to the SMDR device connected to serial port 
    CNl
    If “XON/XOFF” is activated in this address, the DBS 824’s software will stopthe flow of data when the SMDR device 
    s memory buffer becomes full and
    resume the flow when the buffer empties
    ‘XON/XOFF ’ should be deactivated (default setting) if a flow control
    mechanism is present elsewhere in the interface (i e
    in the printer or RTS
    and CTS lines)A flow control mechanism should always be present in orderto prevent data from being lost during transmission
    Programming
    FFl 2# 2# 6## (0 or l)#
    t
    O=Turns off “XONIXOFF” (824 software
    does not control data flow)
    1 =Tums on “XON/XOFF” (824 softwarecontrols data flow)
    NotesDBS 824 Buffer SizeThe size of the DBS 824 buffer for SMDR is 1,000
    bytesThis is the maximum amount of data that the system can hold while
    the SMDR device is emptying its buffer
    Issued 
    3/l/95DBS 824-l O-400Page l-49 
    						
    							SMDR Printing Mode 1 Outbound and InboundFFl
    SMDR Printing Mode 1: Outbound and Inbound
    Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
    FFl 2# 2# 7# (0 or l)#
    DescriptionThe SMDR printer can record data for only outgoing calls or for both
    outbound and inbound calls
    Progiamming
    FFl 2# 2# 7# (0 or l)#
    f
    O=Outbound only
    kInbound and outbound
    NotesActivating SMDR Mode after Using the Bus Monitor ModeLf the DBS 824is in Bus Monitor Mode, the SMDR Mode must be reactivated to resume
    SMDR output. To reactivate SMDR mode from any extension press
    ON/OFF 
    ##90 ON/OFF (to empty buffer), then
    ON/OFF 
    ##!I3 ON/OFF (to activate SMDR mode)
    Page l-50
    DBS 824-l O-400Issued 3/l /95 
    						
    							FFlSMDR Printing Mode 2. Long-Distance and Local Calls
    SMDR Printing Mode 2: Long-Distance and Local Calls
    Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
    FFl 2# 2# 8# (0 or l)#
    DescriptionThe SMDR printer can record data on only long-distance calls or on all types
    of outbound calls
    Pro$ramming
    FFl 2# 2# 8# (0 or l)#
    t
    O=Long-distance only
    l=Local and long-distance
    Issued 3/l /95DBS 824-l O-400Page l-51 
    						
    							SMDR Printing Mode 3 Header TitleFFl
    SMDR Printing Mode 3: Header Title
    Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
    FF1 2# 2# 9# (0 or l)#
    DescriptionTitles such as “Time,” “Duration,” and “COW are printed every 60 lines on
    the SMDR report if this feature is enabled
    Programming
    FFl 2# 2# 9# (0 or l)#
    t
    O=Turns off tlie header
    l=Turns on the headerPage l-52
    DBS 824-l O-400Issued 3/l /95 
    						