FFlDoor Phone ExtensionsDoor Phones Door Phone Extensions Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 8# 3# (DoorPhone)# l# (ExtPort)# DescriptionThis program assigns the extension port that is connected to the door phone boxCPC-S and CPC-M can handle up to 4 door phones, so up to 4 extensions can be assigned (one extension per door phone box) However the extension cannot be an attendant phone (ports 1 and 2) After entering door phone ports, assign them to ring to internal extensions in the next address (FFl 8# 3# DoorPhone# 2# ExtPor#) Programming I FFl W 3## (l-4)# 1# (3-16 or 3024)## tt Door Phone Number (l-4)Extension Port NumberCPC-S 3-16 CPC-M 3-24 Related Programming Door Phone Ring AssignmentsFFl 8# 3# (l-4)# 2# (ExtPort)# (0 or l)# NotesDoor Phone Implementation. To activate door phones after setting the program addresses, the door phone must be unplugged from its port and then plugged back in Call Forwarding Restrictions for Door PhonesDoor phones cannot be set to Call Forward, also, they cannot be members of a hunt group or call coverage group Issued 3/l /95DBS 824-10-4001-123
Door Phone Ring AssignmentsFFlDoor Phone Ring Assignments Software VersionCPC-S and CPC-M, Version 1 0 and higher AddressFFl 8## 3# (DoorPhone)# 2# (ExtPort)# (0 or l)# DescriptionUse this program to determine which extension(s) will ring when a door phone caller initiates a callIt is possible to assign several or all extensions to ring for a door phone call Programming FFl 6## 3# (114)# 2# (l-16 or l-24)# (0 f+ r l)# Door Phone Number (l-4) Extension Port NumberCPC-S (l-16) CPC-M (l-24)O;Do not ring l=Ring Related Programming NotesDoor Phone Extensions FFl 8# 3# @oorPhone)# l# (ExtPort)# Door Phone Tone TypeFFl 8# 3# (DoorPhone)# 4# (0 or l)# Door Phone Ring TimerFFl 8# 3# (DoorPhone)# 5# (0-15)# Door Phone Ring Pattern FFl 8# 3# (DoorPhone)# 6# (0-5)# Interaction With SLT PhonesAn SLT phone (no speaker) can receive a door phone call (same ring pattern as a normal intercom call) Znteraction With ML KeysIf the extension is programmed as an ML key, it can receive a door phone call while the extension is on another call (the phone will “buzz”)However, the door phone call will not transfer to another extension, even if the phone is programmed to transfer (the phone will continue to buzz, until the user picks it up) Conference Calling Restrictions for Door PhonesDoor phone calls cannot be part of a conference call, nor are they subject to Busy Override1-124 DBS 824-l O-400Issued 3/l /95
FFlDoor Opener Access Code Door Opener Access Code Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 8## 3# (DoorPhone)# 3# (OOOO-9999)# DescriptionThis program establishes a 4-digit door opener access code which is entered on the keypad of the extension where the door phone call was answered Entering this code will ‘buzz’ (and unlock) the door To determine the number of seconds the door will remain open use the “DoorOpener Relay Timer” address FFl 8# 3# 7# (0-W Programming FFl 8## 3# (114)# 3# (0000-9999)# ft Door Phone NumberDoor Opener Access Code (l-4) (Def aul t=9999) Related Programming Door Phone Ring AssignmentsFF1 8# 3# (DoorPhone)# 2# (ExtPort)#(0 or l>#Door Opener Relay ‘limerFFl 8# 3# @oorPhone)# 7# (0-5)# Issued 3/l /95DBS 824-l O-4001-125
Door Phone Tone TypeFFl Door Phone Tone Type Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 8## 3# (DoorPhone)# 4## (0 or l)# DescriptionThis program specifies the type of tone that will be heard through the speaker of the designated extension s phone when a door phone caller rings to get in Programming FFl 8# 3# (114)# 4# (0 or l)#Door Phone Number (l-4)Tone Type (heard by extension)O=Door Chime 1 (slow) l=Door Chime 2 (fast) Related ProgrammingDoor Phone Ring Assignments FFl 8# 3# (DoorPhone)# 2# (ExtPort)#(0 or l)#Door Phone Ring Timer FFl 8# 3# (DoorPhone)# 5# (0-15)#Door Phone Ring Pattern FFl 8# 3# (DoorPhone)# 6# (0-5)# NotesDoor Phone ImplementationIf changing the Tone Type setting, activate thechange by unplugging the door phone from its port and plugging it back in l-126 DBS 824-l O-400Issued 3/l 195
FFlDoor Phone Ring Timer Door Phone Ring Timer Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 8# 3# (DoorPhone)# 5## (O-lS)# DescriptionThis program sets the amount of time (in seconds) that a door phone call will ring at its designated extension before it stops ringing If the door phonecaller re-initiates the call before this timer is up the timer will reset and will begin ringing again Programming FFl 8## 3# (j4)# 5#f (Oil,,,Door Phone Number Ring Timer (Default=3 (l-4)see the following table) Table l-32 Door phone ring timer values Related ProgrammingDoor Phone Ring PatternFFI 8# 3# (DoorPhone)# 6# (0-5)# NotesDoor Phone ImplementationIf changing the Ring Timer setting, activate the change by unplugging the door phone from its port and plugging it back in Issued 3/l/95DBS 824-10-4001-127
Door Phone Ring PatternFFl Door Phone Ring Pattern Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 8# 3## (DoorPhone)# 6# (O-5)## DescriptionThis program specifies the ring pattern of the tone that will be heard through the speaker of the designated extension’s phone when a door phone caller rings to get in In this programming address, you will specify the number of seconds between rings (the ring itself has a fixed duration of approximately 3 seconds) Programming FFl 8#3#/-4)# 6#J-5)## Door Phone Number’Number of Seconds Between Rings (l-4)O=Rings one time only (no repeat ringing) 1=4 seconds between rings 2=6 seconds between rings 3=8 seconds between rings 4=10 seconds between rings I5= 12 seconds between rings Related Programming Door Phone Ring TimerFFl 8# 3# (DoorPhone)# 5# (0- 15)# NotesIf changing the Ring Pattern setting, activate the change by unplugging the door phone from its port and plugging it back in l-128DBS 824-l O-400Issued 3/l /95
FFlDoor Opener Relay Timer Door Opener Relay Timer Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 8## 3# (DoorPhone)# 7# (O-5)# DescriptionUse this address to determine the number of seconds a “buzzing” (unlocked) door will remain unlocked for the door phone user to enter the building Default is 4 secondsThis timer begins immediately after the inside extension (called party) enters the Door Opener Access Code to unlock the door Programming FFl8#3#/ -4)#75)ltDoor Phone Number (l-4)Number of Seconds Door Will Remain Open0=2 seconds 14 seconds (default) 2=6 seconds 3=8 seconds 4= 10 seconds 5=12 seconds Related ProgrammingDoor Opener Access Code FFl 8# 3# (DoorPhone)# 3# (0000-9999)#
2. Trunk Programming (FF2) Use the FF2 programming addresses in this chapter to set parameters for the CO trunks of the DBS 824 system Most of these FF2 addresses require a trunk number and/or extension port entryThe acceptable range of trunks/extension ports varies according to the configuration of your DBS 824 system The basic 824 unit (no 208 Expansion Cards installed) supports 4 trunks and 8 extension portsWith one 208 EXP Card, the system will support 6 trunks and 16 extensionsWith two 208 EXP Cards installed (possible only with a CPC M card), the 824 will support 8 trunks and 24 extension ports This chapter covers the following topics TopicPage Trunk Port Operation2-3 DTMF/Pulse Dialing for Trunks2-4 1 Pooled Trunk Access for Group “9”I 2-5 I 1 Pooled Trunk Access for Groups “81-86”I 2-6 I m~iunk TypeI 2-7 I 1 DISA Auto Answer1 2-8 1 Private Trunk Line Automatic Pause for PBX Line2-9 2-10 Dial Tone Detection 2-11 Outbound DTMF Signal Duration for Auto-Dialed2-12 Digits Unsupervised Trunk Conference2-13 Inbound Ring Pattern2-14 Trunk Disconnect Detection Timer2-15 DISA Start Tie2-16 1 DISA End Tie1 2-17 1 Trunk Circuit Type2-18 CO Busy Tone Detection2-19 Issued 3/l/95DBS 824-10-4002-l
FF2I funk Port UperatlonTrunk Port Operation Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FF2 (Trunk)# 1# (0 or l)# DescriptionUse this feature to put a CO trunk in service or remove it from service Programming 1FF2 (I-6 or I-8)# 1# (0 or l)#Trunk Number CPC-S l-6 CPC-M l-8 OS0 trunk is in servicel=CO trunk is out of service NotesPrecaution on Putting Lines Out of ServiceIf a trunk is removed from service, a new incoming caller on that trunk will hear ringing, even though the trunk is not functional Issued 3/l /95DBS 824-l O-4002-3