    							FFlExtension Transfer Recall Timer for Intercom Calls
    Extension Transfer Recall Timer for Intercom Calls
    Software VersionCPCS and CPC-M, Version 1 0 and higherAddress 
    FFI 3## 21# (0-l2)#
    DescriptionWhen one extension transfers a call to another extension, the call will recall to
    Ihe transferring extension if it is not answeredThis timer determines how
    long the transferred call will ring before it recalls
    Programming
    FFl 3## 21# (0112)#
    f
    Timer Setting (Default=7
    see the following table)
    Table l-25Recall timer values for extension-transferred intercom calls
    NumberValue
    0No recall
    120 seconds
    Notes
    240 seconds
    360 seconds
    480 seconds
    5100 seconds
    6
    120 seconds
    7140seconds
    8160seconds
    9
    180seconds
    10200seconds
    11220seconds
    12240secondsInteraction with 
    Cal2 FowmdingIf a call is transferred to an extension that
    has Call Forwarding turned on, the call will follow the call forwarding path if
    the Call Forward--No Answer timer is set to a lesser value than the RecallTier
    Issued 3/l 195DBS 824-l O-400l-103 
    						
    							CO Delayed Ring TimerFFl
    CO Delayed Ring Timer
    Software VerGonCPCLS and CPC-M, Version 1 0 and higherAddress 
    FFl 3# 22# (0-15)#Description
    CO Delayed Ringing allows a secondary phone to ring when incoming trunk
    calls to a primary phone are not answeredThis timer determines how long
    the trunk call will ring at the primary phone before it begins ringing at the
    secondary phone(When the secondary phone begins ringing, the primary
    phone will stop ringing )
    Programming
    FFl 3## 22# (0:15)#
    Timer Setting @efault=2,
    see the following table)
    Table l-26Timer values for CO delayed ringing
    3
    4
    5
    After16seconds
    After20seconds
    After24seconds
    6After28seconds
    7After32seconds
    8After34seconds
    9After36seconds
    10After44seconds
    11After48seconds12
    After 52 seconds
    13After 56 seconds
    14After 60 seconds
    15After 64 secondsl-104
    DBS 824-l O-400Issued 3/l /95 
    						
    							FFlCO Delayed Ring Timer
    Related ProgrammingDelayed Ring 
    FFl 2# l# 21# (0 or l)#
    CO Delayed Day Ring AssignmentsFF4 5# (ExtPort)## (Trunk)#
    CO Delayed Day Ring Assignments for Hunt GroupsFF4 5# (HuntGrp)#
    (Trunk)#
    CO Delayed Night 1 Ring AssignmentsFF4 6# (Ext.Port)# (Trunk)#
    CO Delayed Night 1 Ring Assignments for Hunt GroupsFF4 6#
    (Hunffirp)# (Trunk)#
    CO Delayed Night 2 Ring Assignments FF4 9# 2# (ExtPort)# (Trunk)#
    CO Delayed Night 2 Ring Assignments for Hunt GroupsFF4 9# 2#
    (HuntGrp)# (Trunk)#
    Issued 3/l /95DBS 824-l O-400l-105 
    						
    							Extension Delayed Ring TimerFFl
    Extension Delayed Ring Timer
    Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
    FFl 3# 23# (0-15)#
    DescriptionExtension Delayed Ringing allows a secondary phone to ring when a primary
    phone is not answeredThis timer determines how long the primary phone
    will ring before the call begins ringing at the secondary phone
    Programming
    FFl 3## 23## (O+)#Timer Setting (Default=2
    see the following table)
    Table 1-27Timer values for extension delayed ringing
    Number
    0
    1
    2After4 seconds
    After
    8 seconds
    After12 seconds
    Value
    [ After 16 secondsIAfter 20 seconds
    After 24 seconds
    1 61 After 28 secondsI
    1 After 32 seconds
    1 After 34 seconds
    9After36seconds
    10After44seconds
    11After48seconds
    12After52seconds
    13After56seconds
    14After60seconds
    15After64secondsl-106
    DBS 824-l O-400Issued 3/l /95 
    						
    							FFlExtension Delayed Ring Timer
    Related ProgrammingExtension 
    (BLF) Delayed Ring FF1 2# l# 27# (0 or l)#Extension Delayed Ring Table FF4 
    8# (TargetExtPort)# (SourceExtPort)#
    Issued 3/l/95DBS 824-10-400l-107 
    						
    							Hunt Group No Answer TimerFFlHunt Group No Answer Timer
    Software VersionCPC-S and CPC-M, Version 1 0 and higher
    Address 
    FFl 3# 24# (0-15)##
    DescriptionIf a call has entered a hunt group and the first extension to ring is not
    answered, this timer determines how long the extension will ring before the
    next idle extension in the hunt group begins ringing
    Programming
    FFl 3## 24# (0-15)#
    f
    Timer Setting (Default=2,
    see the following table)
    Table l-28 Hunt group no answer timer values
    NumberValue
    0After 4 seconds
    1After 8 seconds
    2After 12 seconds
    3After 16 seconds
    4After20seconds
    5After24seconds
    6After28seconds
    7After32seconds
    8After34seconds
    9After36seconds
    10After44seconds
    11After48seconds
    12After52seconds
    13After 56 seconds
    14After 60 seconds
    15After 64 seconds
    l-108DBS 824-10-400Issued 3/l/95 
    						
    							FFlAutomatic Day Mode Start Time
    Automatic Day Mode Start Time
    Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
    FFl 3## 25# HHMM#
    DescriptionAutomatic Day Mode allows the DBS 824 to go into “Day
    modeautomatically
    Automatic Night 1 Mode (FFl 3# I#) and Automatic Night 2 Mode (FFI
    3# 29#) allow the DBS 824 to go into “Night 1” and “Night 2” mode
    automatically
    Programming
    To program automatic day mode
    Enter the time using the 24-hour format. The following example sets the time
    to830am
    FFl W 25## 0830##
    Time Setting (8 30 a m )
    (in 24-hour format)
    To turn automatic day mode off
    FFl 3# 25# CONF ON/OFFIRelated Programming
    Tiie Setting 
    FFl l# 2#
    Automatic Night 1 Mode Start Time FFl 3# l#
    Automatic Night 2 Mode Start TimeFF 1 3# 29#
    NotesNight Key OperationIf only one of the Auto modes is turned on, the
    NIGHT key is used to turn off the Auto mode
    For instance, if Night mode
    has been activated automatically, the attendant must press the NIGHT key 
    to
    go into Day mode
    Issued 3/l /95DBS 824-l O-400l-109 
    						
    							Automatic Day Mode Start TimeFFlIf both Auto Day and Auto Night modes are turned on the attendant NIGHT
    key cannot be usedWhen one Auto mode is turned on the mode cannot be reset by the NIGHT
    key until 3 minutes after the Auto mode is activated(When both Auto modes
    are set, the NIGHT key cannot be used )
    Required Intervals Between Auto Day and Night ModesIf both Auto
    modes are set, the manufacturer recommends that the starting times of the
    modes differ by at least one hour
    l-110DBS 824-10-400Issued 3/l/95 
    						
    							FFlWait Timer For Auto-Repeat Dialing
    Wait Timer For Auto-Repeat Dialing
    Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
    FFl 3# 26# (0-15)#
    DescriptionUse this program to set the amount of time the DBS 824 will wait before
    automatically redialing a 
    number
    Programming
    FFl 3# 26# (0-15)#
    +Timer Setting (Default=8
    see the following table)
    Table 1-29 Auto-Repeat dialing wait timer values
    Number
    0
    1
    2
    3
    4
    1 second
    5 seconds
    10 seconds
    15 seconds
    20 seconds
    Value
    525seconds
    630seconds
    735seconds
    840 seconds
    945 seconds
    I
    1
    101 50 secondsI
    1 55 seconds
    1 60 seconds
    1 65 seconds
    12
    13
    1470 seconds
    1575 seconds
    Related ProgrammingAuto-Repeat Dialing Count 
    FFl 2# l# 34# (0-15)#
    Issued 3/l i95DBS 824-l O-400l-111 
    						
    							Wait Timer For Auto-Repeat DialingFFlBusy Tone 
    (BT) Detection Timer FFl 3# 27#Dial Tone (DT) Detection Timer 
    FFl 3# 28#CO Busy Tone 
    (BT) Detection for Auto-Repeat Dialing
    FF2 (Trunk)# 22#l-112
    DBS 824-l O-400Issued 3/l /95 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Dbs 824 Instructions Manual