    Have a look at the manual Starplus Triad Xts Digital Key Telephone System System Programming And Operation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 9 Triad manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 654
    							Programming TablesE-15
    Appendix E - Customer Database Programming
    FLASH 09 2 MOH Assignments Channel 4 None
    3 MOH Assignments Channel 5 None
    4 MOH Assignments Channel 6 None
    5 MOH Assignments Channel 7 None
    6 MOH Assignments Channel 8 None
    7 Proctor 911 Power Failure SLT Sta # None
    8 Node/Hub Identification 01-16 01
    9Leading Digit 0-9 0
    FLASH 10 Attendant Station Assignment STA 100
    FLASH 11 1 System Time And Date MMM/DD/YY,
    12/24MMM/DD/
    YY‚12Hr
    FLASH 12 PBX Dialing Codes 5 (2-digits) None
    FLASH 13 1 Executive/Secretary Pairs Sta #, Sta # None
    2 Executive/Secretary Pairs Sta #, Sta # None
    3 Executive/Secretary Pairs Sta #, Sta # None
    4 Executive/Secretary Pairs Sta #, Sta # None
    FLASH 14 1 Relay Programming None
    2Relay Programming None
    3Relay Programming None
    4Relay Programming None
    5Relay Programming None
    6Relay Programming None
    7Relay Programming None
    FLASH 15Baud Rate Assignments
    1 Port #1 (RS-232Cport labeled SCMI on MPB) 19.2K
    2 Port #2 (Modem - baud auto-negotiated) None N/A
    3 Port #3 (RS-232C port on optional SIU on MPB) 9600
    4 Port #4 (RS-232C port on optional SIU on MPB) 9600
    5 Port #5 (UART on MPB) 9600
    FLASH 20Access Codes
    1 DISA Access Code 100-999 100
    2 Database Admin Password 0000-9999 3226
    Table E-1: System Parameters
    Program 
    CodeFlexible
    ButtonFunction Format Default Customer Data 
    						
    							E-16Programming Tables
    Appendix E - Customer Database Programming
    FLASH 21Station Message Detail Recording
    1 SMDR Enable/Disable Disabled/Enabled Disabled
    2 Long Distance/Local Assignment LD/All LD Only
    3 Character Print Assignment 80/30 80
    5 SMDR Port Assignments 1/3/4/5 Port #1
    FLASH 22Weekly Night Mode Schedule
    1 Automatic/Manual Operation Auto/Manual Manual
    2 Day of Week Programming 08:00–17:00
    ####-####(0-4)
    (5-6)
    3 Day of Week Programming 08:00–17:00
    ####-####(0-4)
    (5-6)
    4 Day of Week Programming 08:00–17:00
    ####-####(0-4)
    (5-6)
    5 Day of Week Programming 08:00–17:00
    ####-####(0-4)
    (5-6)
    6 Day of Week Programming 08:00–17:00
    ####-####(0-4)
    (5-6)
    7 Day of Week Programming 08:00–17:00
    ####-####(0-4)
    (5-6)
    8 Day of Week Programming 08:00–17:00
    ####-####(0-4)
    (5-6)
    Table E-1: System Parameters
    Program 
    CodeFlexible
    ButtonFunction Format Default Customer Data 
    						
    							Programming TablesE-17
    Appendix E - Customer Database Programming
    FLASH 42Flexible CO Port Assignments
    1 Flexible CO Por t Por ts 1-8
    2 Flexible CO Por t Ports 9-16
    3 Flexible CO Por t Ports 17-24
    4 Flexible CO Por t Ports 25-32
    5 Flexible CO Por t Ports 33-40
    6 Flexible CO Por t Ports 41-48
    7 Flexible CO Por t (M PB2) Ports 49-56
    8 Flexible CO Por t (M PB2) Ports 57-64
    9 Flexible CO Por t (M PB2) Ports 65-72
    10 Flexible CO Por t (M PB2) Ports 73-80
    11 Flexible CO Por t (M PB2) Ports 81-88
    12 Flexible CO Por t (M PB2) Ports 89-96
    13 Flexible CO Por t (MPB2) Ports 97-104
    14 Flexible CO Por t (MPB2) Ports 105-112
    15 Flexible CO Por t (MPB2) Ports 113-120
    16 Flexible CO Por t (MPB2) Ports 121-128
    17 Flexible CO Por t (MPB2) Ports 129-136
    18 Flexible CO Por t (MPB2) Ports 137-144
    Table E-1: System Parameters
    Program 
    CodeFlexible
    ButtonFunction Format Default Customer Data 
    						
    							E-18Programming Tables
    Appendix E - Customer Database Programming
    FLASH 45ISDN Page A Programming
    1 BRI CO Type NI1 NI1
    2 PRI CO Type NI2 NI2
    3 Framing T1, ESF, D4 ESF
    4 NT/TE Mode NT, TE TE
    5 Power Disabled/Enabled Disabled
    6 Directory Number (PRI) 0-9, *, # None
    7 Max Out I-Frames 001-127 K001
    8 Leading 1 Disabled/Enabled Enabled
    9 Leading 011 Disabled/Enabled Enabled
    10 7/8 Digit Number Plan ITU, CO ITU
    11 Calling Number Disabled/Enabled Enabled
    12 Loopback Normal, Near End, 
    Fa r  E ndNormal
    13 10 Digit Number Plan ITU, CO ITU
    14 11 Digit Number Plan ITU, CO ITU
    FLASH 45ISDN Page B Programming
    1 Maximum Number Retransmission 0-9 3
    2 Maximum Octets 000-999 260
    3 Maximum TEI ID Request 000-999 003
    4 Maximum XID Retransmission 0-9 sec 3 sec
    5 T-200 00-99 sec 01 sec
    6 Minimum TEI ID Check Message 00-99 sec 01 sec
    7 Minimum TEI ID Request 00-99 sec 02 sec
    8 Message Exchange Timer 00-99 sec 15 sec
    9 Minimum XID Retransmission 0-9 sec 3 sec
    10 Inter Digit T/O 00-99 sec 25 sec
    11 Set-up Timer 00-99 sec 10 sec
    12 Disconnect Timer 00-99 sec 04 sec
    13 Release Request 00-99 sec 04 sec
    14 Link Disconnect 20-30 sec 30 sec
    15 Call Proceeding 00-99 sec 60 sec
    16 Connect Request 00-99 sec 04 sec
    Table E-1: System Parameters
    Program 
    CodeFlexible
    ButtonFunction Format Default Customer Data 
    						
    							Programming TablesE-19
    Appendix E - Customer Database Programming
    17 Restart Request Timer 120 sec
    FLASH 46VoIP Network Programming
    1 IP Address None
    2Subnet Request None
    3 Router IP Address None
    4Domain Name None
    5 Vocoder Value G.723.1
    FLASH 47T-1/ISDN Alarm Programming
    1 Carrier Loss Alarm Disabled/Enabled Enabled
    2 Blue Alarm Disabled/Enabled Enabled
    3 Yellow Alarm Disabled/Enabled Enabled
    4 Red Alarm Disabled/Enabled Enabled
    5 Bipolar Alarm Disabled/Enabled Enabled
    6 Frame Slip Alarm Disabled/Enabled Enabled
    7 Data Errors Alarm Disabled/Enabled Enabled
    11 Enable/Disable (Carrier Loss Alarm) Disabled/Enabled Enabled
    12 Clear Alarm Disabled/Enabled Enabled
    13 Minor Alarm 00-99 min 15 min
    14 Major Alarm 00-99 min 30 min
    15 Time Period 00-99 min 5 min
    16 Attendant Display Disabled/Enabled Enabled
    Table E-1: System Parameters
    Program 
    CodeFlexible
    ButtonFunction Format Default Customer Data 
    						
    							E-20Programming Tables
    Appendix E - Customer Database Programming
    FLASH 52Flexible Numbering Assignments
    21/24Station Port Flexible
    100 100
    101 101
    102 102
    103 103
    104 104
    105 105
    106 106
    107 107
    108 108
    109 109
    110 110
    111 111
    112 112
    113 113
    114 114
    115 115
    116 116
    117 117
    118 118
    119 119
    120 120
    121 121
    122 122
    123 123
    124 124
    125 125
    126 126
    127 127
    128 128
    129 129
    130 130
    Table E-1: System Parameters
    Program 
    CodeFlexible
    ButtonFunction Format Default Customer Data 
    						
    							Programming TablesE-21
    Appendix E - Customer Database Programming
    FLASH 52Flexible Numbering Assignments
    21/24Station Port Flexible
    131 131
    132 132
    133 133
    134 134
    135 135
    136 136
    137 137
    138 138
    139 139
    140 140
    141 141
    142 142
    143 143
    144 144
    145 145
    146 146
    147 147
    148 148
    149 149
    150 150
    151 151
    152 152
    153 153
    154 154
    155 155
    156 156
    157 157
    158 158
    159 159
    160 160
    161 161
    Table E-1: System Parameters
    Program 
    CodeFlexible
    ButtonFunction Format Default Customer Data 
    						
    							E-22Programming Tables
    Appendix E - Customer Database Programming
    FLASH 52Flexible Numbering Assignments
    21/24Station Port Flexible
    162 162
    163 163
    164 164
    165 165
    166 166
    167 167
    168 168
    169 169
    170 170
    171 171
    172 172
    173 173
    174 174
    175 175
    176 176
    177 177
    178 178
    179 179
    180 180
    181 181
    182 182
    183 183
    184 184
    185 185
    186 186
    187 187
    188 188
    189 189
    190 190
    191 191
    192 192
    Table E-1: System Parameters
    Program 
    CodeFlexible
    ButtonFunction Format Default Customer Data 
    						
    							Programming TablesE-23
    Appendix E - Customer Database Programming
    FLASH 52Flexible Numbering Assignments
    21/24Station Port Flexible
    193 193
    194 194
    195 195
    196 196
    197 197
    198 198
    199 199
    200 200
    201 201
    202 202
    203 203
    204 204
    205 205
    206 206
    207 207
    208 208
    209 209
    210 210
    211 211
    212 212
    213 213
    214 214
    215 215
    216 216
    217 217
    218 218
    219 219
    220 220
    221 221
    222 222
    223 223
    Table E-1: System Parameters
    Program 
    CodeFlexible
    ButtonFunction Format Default Customer Data 
    						
    							E-24Programming Tables
    Appendix E - Customer Database Programming
    FLASH 52Flexible Numbering Assignments
    21/24Station Port Flexible
    224 224
    225 225
    226 226
    227 227
    228 228
    229 229
    230 230
    231 231
    232 232
    233 233
    234 234
    235 235
    236 236
    237 237
    238 238
    239 239
    240 240
    241 241
    242 242
    243 243
    244 244
    245 245
    246 246
    247 247
    248 248
    249 249
    250 250
    251 251
    252 252
    253 253
    Table E-1: System Parameters
    Program 
    CodeFlexible
    ButtonFunction Format Default Customer Data 
    						
    All Triad manuals Comments (0)