Have a look at the manual Starplus Triad Xts Digital Key Telephone System System Programming And Operation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 9 Triad manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Programming TablesE-15 Appendix E - Customer Database Programming FLASH 09 2 MOH Assignments Channel 4 None 3 MOH Assignments Channel 5 None 4 MOH Assignments Channel 6 None 5 MOH Assignments Channel 7 None 6 MOH Assignments Channel 8 None 7 Proctor 911 Power Failure SLT Sta # None 8 Node/Hub Identification 01-16 01 9Leading Digit 0-9 0 FLASH 10 Attendant Station Assignment STA 100 FLASH 11 1 System Time And Date MMM/DD/YY, 12/24MMM/DD/ YY‚12Hr FLASH 12 PBX Dialing Codes 5 (2-digits) None FLASH 13 1 Executive/Secretary Pairs Sta #, Sta # None 2 Executive/Secretary Pairs Sta #, Sta # None 3 Executive/Secretary Pairs Sta #, Sta # None 4 Executive/Secretary Pairs Sta #, Sta # None FLASH 14 1 Relay Programming None 2Relay Programming None 3Relay Programming None 4Relay Programming None 5Relay Programming None 6Relay Programming None 7Relay Programming None FLASH 15Baud Rate Assignments 1 Port #1 (RS-232Cport labeled SCMI on MPB) 19.2K 2 Port #2 (Modem - baud auto-negotiated) None N/A 3 Port #3 (RS-232C port on optional SIU on MPB) 9600 4 Port #4 (RS-232C port on optional SIU on MPB) 9600 5 Port #5 (UART on MPB) 9600 FLASH 20Access Codes 1 DISA Access Code 100-999 100 2 Database Admin Password 0000-9999 3226 Table E-1: System Parameters Program CodeFlexible ButtonFunction Format Default Customer Data
E-16Programming Tables Appendix E - Customer Database Programming FLASH 21Station Message Detail Recording 1 SMDR Enable/Disable Disabled/Enabled Disabled 2 Long Distance/Local Assignment LD/All LD Only 3 Character Print Assignment 80/30 80 5 SMDR Port Assignments 1/3/4/5 Port #1 FLASH 22Weekly Night Mode Schedule 1 Automatic/Manual Operation Auto/Manual Manual 2 Day of Week Programming 08:00–17:00 ####-####(0-4) (5-6) 3 Day of Week Programming 08:00–17:00 ####-####(0-4) (5-6) 4 Day of Week Programming 08:00–17:00 ####-####(0-4) (5-6) 5 Day of Week Programming 08:00–17:00 ####-####(0-4) (5-6) 6 Day of Week Programming 08:00–17:00 ####-####(0-4) (5-6) 7 Day of Week Programming 08:00–17:00 ####-####(0-4) (5-6) 8 Day of Week Programming 08:00–17:00 ####-####(0-4) (5-6) Table E-1: System Parameters Program CodeFlexible ButtonFunction Format Default Customer Data
Programming TablesE-17 Appendix E - Customer Database Programming FLASH 42Flexible CO Port Assignments 1 Flexible CO Por t Por ts 1-8 2 Flexible CO Por t Ports 9-16 3 Flexible CO Por t Ports 17-24 4 Flexible CO Por t Ports 25-32 5 Flexible CO Por t Ports 33-40 6 Flexible CO Por t Ports 41-48 7 Flexible CO Por t (M PB2) Ports 49-56 8 Flexible CO Por t (M PB2) Ports 57-64 9 Flexible CO Por t (M PB2) Ports 65-72 10 Flexible CO Por t (M PB2) Ports 73-80 11 Flexible CO Por t (M PB2) Ports 81-88 12 Flexible CO Por t (M PB2) Ports 89-96 13 Flexible CO Por t (MPB2) Ports 97-104 14 Flexible CO Por t (MPB2) Ports 105-112 15 Flexible CO Por t (MPB2) Ports 113-120 16 Flexible CO Por t (MPB2) Ports 121-128 17 Flexible CO Por t (MPB2) Ports 129-136 18 Flexible CO Por t (MPB2) Ports 137-144 Table E-1: System Parameters Program CodeFlexible ButtonFunction Format Default Customer Data
E-18Programming Tables Appendix E - Customer Database Programming FLASH 45ISDN Page A Programming 1 BRI CO Type NI1 NI1 2 PRI CO Type NI2 NI2 3 Framing T1, ESF, D4 ESF 4 NT/TE Mode NT, TE TE 5 Power Disabled/Enabled Disabled 6 Directory Number (PRI) 0-9, *, # None 7 Max Out I-Frames 001-127 K001 8 Leading 1 Disabled/Enabled Enabled 9 Leading 011 Disabled/Enabled Enabled 10 7/8 Digit Number Plan ITU, CO ITU 11 Calling Number Disabled/Enabled Enabled 12 Loopback Normal, Near End, Fa r E ndNormal 13 10 Digit Number Plan ITU, CO ITU 14 11 Digit Number Plan ITU, CO ITU FLASH 45ISDN Page B Programming 1 Maximum Number Retransmission 0-9 3 2 Maximum Octets 000-999 260 3 Maximum TEI ID Request 000-999 003 4 Maximum XID Retransmission 0-9 sec 3 sec 5 T-200 00-99 sec 01 sec 6 Minimum TEI ID Check Message 00-99 sec 01 sec 7 Minimum TEI ID Request 00-99 sec 02 sec 8 Message Exchange Timer 00-99 sec 15 sec 9 Minimum XID Retransmission 0-9 sec 3 sec 10 Inter Digit T/O 00-99 sec 25 sec 11 Set-up Timer 00-99 sec 10 sec 12 Disconnect Timer 00-99 sec 04 sec 13 Release Request 00-99 sec 04 sec 14 Link Disconnect 20-30 sec 30 sec 15 Call Proceeding 00-99 sec 60 sec 16 Connect Request 00-99 sec 04 sec Table E-1: System Parameters Program CodeFlexible ButtonFunction Format Default Customer Data
Programming TablesE-19 Appendix E - Customer Database Programming 17 Restart Request Timer 120 sec FLASH 46VoIP Network Programming 1 IP Address None 2Subnet Request None 3 Router IP Address None 4Domain Name None 5 Vocoder Value G.723.1 FLASH 47T-1/ISDN Alarm Programming 1 Carrier Loss Alarm Disabled/Enabled Enabled 2 Blue Alarm Disabled/Enabled Enabled 3 Yellow Alarm Disabled/Enabled Enabled 4 Red Alarm Disabled/Enabled Enabled 5 Bipolar Alarm Disabled/Enabled Enabled 6 Frame Slip Alarm Disabled/Enabled Enabled 7 Data Errors Alarm Disabled/Enabled Enabled 11 Enable/Disable (Carrier Loss Alarm) Disabled/Enabled Enabled 12 Clear Alarm Disabled/Enabled Enabled 13 Minor Alarm 00-99 min 15 min 14 Major Alarm 00-99 min 30 min 15 Time Period 00-99 min 5 min 16 Attendant Display Disabled/Enabled Enabled Table E-1: System Parameters Program CodeFlexible ButtonFunction Format Default Customer Data
E-20Programming Tables Appendix E - Customer Database Programming FLASH 52Flexible Numbering Assignments 21/24Station Port Flexible 100 100 101 101 102 102 103 103 104 104 105 105 106 106 107 107 108 108 109 109 110 110 111 111 112 112 113 113 114 114 115 115 116 116 117 117 118 118 119 119 120 120 121 121 122 122 123 123 124 124 125 125 126 126 127 127 128 128 129 129 130 130 Table E-1: System Parameters Program CodeFlexible ButtonFunction Format Default Customer Data
Programming TablesE-21 Appendix E - Customer Database Programming FLASH 52Flexible Numbering Assignments 21/24Station Port Flexible 131 131 132 132 133 133 134 134 135 135 136 136 137 137 138 138 139 139 140 140 141 141 142 142 143 143 144 144 145 145 146 146 147 147 148 148 149 149 150 150 151 151 152 152 153 153 154 154 155 155 156 156 157 157 158 158 159 159 160 160 161 161 Table E-1: System Parameters Program CodeFlexible ButtonFunction Format Default Customer Data
E-22Programming Tables Appendix E - Customer Database Programming FLASH 52Flexible Numbering Assignments 21/24Station Port Flexible 162 162 163 163 164 164 165 165 166 166 167 167 168 168 169 169 170 170 171 171 172 172 173 173 174 174 175 175 176 176 177 177 178 178 179 179 180 180 181 181 182 182 183 183 184 184 185 185 186 186 187 187 188 188 189 189 190 190 191 191 192 192 Table E-1: System Parameters Program CodeFlexible ButtonFunction Format Default Customer Data
Programming TablesE-23 Appendix E - Customer Database Programming FLASH 52Flexible Numbering Assignments 21/24Station Port Flexible 193 193 194 194 195 195 196 196 197 197 198 198 199 199 200 200 201 201 202 202 203 203 204 204 205 205 206 206 207 207 208 208 209 209 210 210 211 211 212 212 213 213 214 214 215 215 216 216 217 217 218 218 219 219 220 220 221 221 222 222 223 223 Table E-1: System Parameters Program CodeFlexible ButtonFunction Format Default Customer Data
E-24Programming Tables Appendix E - Customer Database Programming FLASH 52Flexible Numbering Assignments 21/24Station Port Flexible 224 224 225 225 226 226 227 227 228 228 229 229 230 230 231 231 232 232 233 233 234 234 235 235 236 236 237 237 238 238 239 239 240 240 241 241 242 242 243 243 244 244 245 245 246 246 247 247 248 248 249 249 250 250 251 251 252 252 253 253 Table E-1: System Parameters Program CodeFlexible ButtonFunction Format Default Customer Data