Have a look at the manual Starplus Triad Xts Digital Key Telephone System System Programming And Operation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 9 Triad manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ISDN Programming - Page A2-183 Chapter 2 - Features and Operation DEFAULT … ITU (ISDN plan) Nortel DMS 100 Only 1. Change Flash 45, button 10 (Numbering Plan) to CO by dialing 1 HOLD. 2. Set the definition in the DMS 100 Central Office Switch. The DMS 100 Office refers to this switch as National or N12 Standard so they know not to look at this parameter in their switch. LTDEF should be set to NI PRI N12 V1. Calling Number Description 0 disables the calling party number from being sent to the CO. 1 will enable the calling party number feature and the number will be sent to the CO. Programming Steps 1. Press the CALLING NUMBER flexible button (FLASH 45, Page A, Button #11). 2. Enter a 0 or 1 on the dial pad to enable/disable this feature. [0] = Disabled [1] = Enabled 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Calling Number is enabled. Loopback Description Do not change the Loopback setting unless advised to do so by Technical Support. Programming Steps 1. Press the LOOPBACK flexible button (FLASH 45, Page A, Button #12). When connecting a PRI to a Nortel DMS 100, enter a 1 for the number plan. CALLING NUMBER 0-1 ENABLED LOO PB ACK 0-2 NORMAL
2-184ISDN Programming - Page A Chapter 2 - Features and Operation 2. Enter a valid number (0-2) on the dial pad. [0] = Normal mode [1] = Near end mode [2] = Far end mode 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Loopback setting is normal. BRI 10-Digit Number Plan Description The BRI 10-Digit Number Plan is the specific plan that a particular Central Office uses for 10-digit BRI calls. Programming Steps 1. Press the BRI 10 DIGIT No PLAN flexible button (FLASH 45, Page A, Button #13). 2. Enter a 0, 1, or 2 on the dial pad to select the desired Number Plan. [0] = Selects ITU number plan [1] = Selects CO number plan [2] = Unknown 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … BRI 10-Digit Number Plan setting is ITU. BRI 11-Digit Number Plan Description The 11-Digit Number Plan is the specific plan that a particular Central Office uses for 11-digit BRI calls. Programming Steps 1. Press the BRI 11 DIGIT No PLAN flexible button (FLASH 45, Page A, Button #14). 2. Enter a 0, 1, or 2 on the dial pad to select the desired Number Plan. [0] = Selects ITU number plan [1] = Selects CO number plan [2] = Unknown 3. Press the HOLD button. A confirmation tone sounds and the display updates. BRI 10 DIGIT No PLAN 0-2 ITU BRI 11 DIGIT No PLAN 0-2 ITU
ISDN Programming - Page B2-185 Chapter 2 - Features and Operation DEFAULT … BRI 11-Digit Number Plan setting is ITU. ISDN Programming - Page B Description When entering the ISDN attributes portion of the database, the programmer may decide to enter information for a range of slots or one specific slot. Range programming lets the programmer change a specific parameter or a few parameters for an entire range of slots, leaving intact the remaining data fields that do not require change. Those data fields continue to operate with the previously programmed data. Programming Steps 1. Press FLASH and dial [45]. The following message displays: 2. Enter a valid number for the range of slots being programmed. If only one slot is being programmed, enter that number twice (02 02 = Slot 2, Cabinet 0). 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. Flexible button #19 (Page A) is lit. IMPORTANT -- These timers should not be adjusted UNLESS working with Technical Support or your telephone company. MAX # OF RETRANSMISSIONSMAX OCTETSMAX TEI RQSTMAX XID RETRANSMISSION 1Q2W3E4R T-200MIN TEI ID CHK MSGMIN TEI ID RQSTMSG EXCHANGE TIMER 5T6Y7U8I MIN XID RETRANSMINTER-DIGIT T/OSET UP TIMERDISCONNECT TIMER 9O10 P11 A12 S RELEASE REQUESTLINK DISCONNECTCALL PROCEEDINGCONNECT REQUEST 13 D14 F15 G16 H RESTART REQ TIMERPAGE APAGE B 17 J18 K19 L20 ; PAGE CPREVIOUSNEXTNEW RANGE 21 Z22 X23 C24 V ISDN ATTRIBUTES SELECT A SLOT RANGE
2-186ISDN Programming - Page B Chapter 2 - Features and Operation 4. Press button #20 to select Page B. The following message displays to indicate current programming of that slot or group of slots: XY-XY = Slot Range X = Cabinet (0, 1, 2) Y = Slot (0-8) NOTE -- Slot 8, Cabinet 0 is reserved for the MISB Maximum Number Retransmission Description The Maximum Number of Retransmissions of a frame (N200) is a system parameter. Do not change the Maximum Number Retransmission setting unless advised to do so by Technical Support. Programming Steps 1. Press the MAX # RETRANSMSN flexible button (FLASH 45, Page B, Button #1). 2. Enter a valid number (0-9) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Maximum Number Retransmission is 3. Maximum Octets Description The maximum number of octets in an I-Frame/information field (N201) is a system parameter. Do not change the Maximum Octets setting unless advised to do so by Technical Support. Programming Steps 1. Press the MAX OCTETS flexible button (FLASH 45, Page B, Button #2). 2. Enter a valid number (000-999) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. (000 = Disable) DEFAULT … Maximum Octet setting is 260. XY - XY PAGE B ENTER BUTTON NUMBER MAX # RETRANSMSN 0-9 N200 3 MAX OCTETS 000-999 N201 260
ISDN Programming - Page B2-187 Chapter 2 - Features and Operation Maximum TEI Request Description This feature is reserved for future use. Programming Steps 1. Press the MAX TEI RQST flexible button (FLASH 45, Page B, Button #3). 2. Enter a valid number (000-999) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Maximum TEI Request setting is 003. Maximum XID Retransmission Description Do not change the Maximum number of XID Retransmissions setting unless advised to do so by Technical Support. Programming Steps 1. Press the MAX XID RETRANSMISSION flexible button (FLASH 45, Page B, Button #4). 2. Enter a valid number (0-9 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Maximum XID Retransmission setting is 3 seconds. T- 2 0 0 Description The T-200 timer is used to set the time to wait for an I-Frame acknowledgement. Do not change the T-200 timer setting unless advised to do so by Technical Support. Programming Steps 1. Press the T-200 flexible button (FLASH 45, Page B, Button #5). 2. Enter a valid number (00-99 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … T200 setting is 1 second. MAX TEI RQST 000-999 N202 003 MAX XID RETRANSMSN 0-9 N204 3 T200 00-99 01
2-188ISDN Programming - Page B Chapter 2 - Features and Operation Minimum TEI ID Check Message Description The Minimum TEI ID Check Message feature sets the minimum time between retransmission of the TEI identity check messages. Do not change the Minimum TEI ID Check Message setting unless advised to do so by Technical Support. Programming Steps 1. Press the MIN TEI ID CHK MSG flexible button (FLASH 45, Page B, Button #6). 2. Enter a valid number (00-99 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Minimum TEI ID Check Message setting is 1 second. Minimum TEI ID Request Description This feature is reserved for future use. Programming Steps 1. Press the MIN TEI ID RQST flexible button (FLASH 45, Page B, Button #7). 2. Enter a valid number (00-99 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Minimum TEI ID Request setting is 2 seconds. Message Exchange Timer Description The Message Exchange Timer setting establishes the maximum time allowed without frames being exchanged. Do not change the Message Exchange Timer setting unless advised to do so by Technical Support. MIN TEI ID CHK MSG 00-99 T201 01 MIN TEI ID RQST MSG 00-99 T202 02
ISDN Programming - Page B2-189 Chapter 2 - Features and Operation Programming Steps 1. Press the MSG EXCHANGE TIMER flexible button (FLASH 45, Page B, Button #8). 2. Enter a valid number (00-99 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Message Exchange Timer setting is 15 seconds. Minimum XID Retransmission Description The Minimum XID Retransmission setting establishes the minimum time between XID messages. Do not change the Minimum XID Retransmission setting unless advised to do so by Technical Support. Programming Steps 1. Press the MIN XID RETRANSMSN flexible button (FLASH 45, Page B, Button #9). 2. Enter a valid number (0-9 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Minimum XID Retransmission setting is 3 seconds. Inter-Digit T / O Description Do not change the Inter-digit time out setting unless advised to do so by Technical Support. Programming Steps 1. Press the INTER-DIGIT T/O flexible button (FLASH 45, Page B, Button #10). 2. Enter a valid number (00-99 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Inter-digit Timeout setting is 25 seconds. MSG EXCHANGE TIMER 00-99 T203 15 MIN XID RETRANSMSN 0-9 T204 3 INTER-DIGIT T/O 00-99 T302 25
2-190ISDN Programming - Page B Chapter 2 - Features and Operation Set-Up Timer Description The Set-up Timer setting establishes the response time to setup message. Do not change the Set-up Timer setting unless advised to do so by Technical Support. Programming Steps 1. Press the SET UP TIMER flexible button (FLASH 45, Page B, Button #11). 2. Enter a valid number (00-99 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Set-up Timer setting is 10 seconds Disconnect Timer Description The Disconnect Timer setting establishes the response time to a disconnect message. Do not change the Disconnect Timer setting unless advised to do so by Technical Support. Programming Steps 1. Press the DISCONNECT TIMER flexible button (FLASH 45, Page B, Button #12). 2. Enter a valid number (00-99 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Disconnect Timer setting is 4 seconds. SETUP TIMER 00-99 T303 10 DISCONNECT TIMER 00-99 T305 04
ISDN Programming - Page B2-191 Chapter 2 - Features and Operation Release Request Description Do not change the Release Request setting unless advised to do so by Technical Support. Programming Steps 1. Press the RELEASE REQUEST flexible button (FLASH 45, Page B, Button #13). 2. Enter a valid number (00-99 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Release Request Timer setting is 4 seconds. Link Disconnect Description Do not change the Link Disconnect Timer setting unless advised to do so by Technical Support. Programming Steps 1. Press the LINK DISCONNECT flexible button (FLASH 45, Page B, Button #14). 2. Enter a valid number (20-30 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Link Disconnect setting is 30 seconds. Call Proceeding Description Do not change the Call Proceeding setting unless advised to do so by Technical Support. Programming Steps 1. Press the CALL PROCEEDING flexible button (FLASH 45, Page B, Button #15). 2. Enter a valid number (00-99 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Call Proceeding setting is 60 seconds. RELEASE REQUEST 00-99 T308 04 LINK DISCONNECT 20-30 T309 30 CALL PROCEEDING 00-99 T310 60
2-192ISDN Programming - Page B Chapter 2 - Features and Operation Connect Request Description Do not change the Connect Request Timer setting unless advised to do so by Technical Support. Programming Steps 1. Press the CONNECT REQUEST flexible button (FLASH 45, Page B, Button #16). 2. Enter a valid number (00-99 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Connect Request setting is 4 seconds. Restart Request Timer Description Do not change the Restart Request Timer setting unless advised to do so by Technical Support. Programming Steps 1. Press the RESTART REQ TIMER flexible button (FLASH 45, Page B, Button #17). 2. Enter a valid number (0-200 seconds) on the dial pad. 3. Press the HOLD button. A confirmation tone sounds and the display updates. DEFAULT … Restart Request Timer setting is 120 seconds. CONNECT REQUEST 00-99 T313 04 RESTART REQ TIMER 0-200 T 3 16 120