    Have a look at the manual Starplus Triad Xts Digital Key Telephone System System Programming And Operation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 9 Triad manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 654
    							ISDN Programming - Page A2-183
    Chapter 2 - Features and Operation
    DEFAULT … ITU (ISDN plan)
    Nortel DMS 100 Only
    1. Change Flash 45, button 10 (Numbering Plan) to CO by dialing 1 HOLD.
    2. Set the definition in the DMS 100 Central Office Switch.
    The DMS 100 Office refers to this switch as National or N12 Standard so they know 
    not to look at this parameter in their switch.
    LTDEF should be set to NI PRI N12 V1.
    Calling Number
    Description
    0 disables the calling party number from being sent to the CO. 1 will enable the calling party 
    number feature and the number will be sent to the CO.
    Programming Steps
    1. Press the CALLING NUMBER flexible button (FLASH 45, Page A, Button #11).
    2. Enter a 0 or 1 on the dial pad to enable/disable this feature.
    [0] = Disabled
    [1] = Enabled
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Calling Number is enabled.
    Loopback
    Description
    Do not change the Loopback setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the LOOPBACK flexible button (FLASH 45, Page A, Button #12).
    When connecting a PRI to a Nortel DMS 100, enter a 1 for the number plan.
    CALLING NUMBER 0-1
    ENABLED
    LOO PB ACK 0-2
    NORMAL 
    						
    							2-184ISDN Programming - Page A
    Chapter 2 - Features and Operation
    2. Enter a valid number (0-2) on the dial pad.
    [0] = Normal mode
    [1] = Near end mode
    [2] = Far end mode
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Loopback setting is normal.
    BRI 10-Digit Number Plan
    Description
    The BRI 10-Digit Number Plan is the specific plan that a particular Central Office uses for 
    10-digit BRI calls.
    Programming Steps
    1. Press the BRI 10 DIGIT No PLAN flexible button (FLASH 45, Page A, Button #13).
    2. Enter a 0, 1, or 2 on the dial pad to select the desired Number Plan.
    [0] = Selects ITU number plan
    [1] = Selects CO number plan
    [2] = Unknown
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … BRI 10-Digit Number Plan setting is ITU.
    BRI 11-Digit Number Plan
    Description
    The 11-Digit Number Plan is the specific plan that a particular Central Office uses for 11-digit 
    BRI calls.
    Programming Steps
    1. Press the BRI 11 DIGIT No PLAN flexible button (FLASH 45, Page A, Button #14).
    2. Enter a 0, 1, or 2 on the dial pad to select the desired Number Plan.
    [0] = Selects ITU number plan
    [1] = Selects CO number plan
    [2] = Unknown
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    BRI 10 DIGIT No PLAN 0-2
    ITU
    BRI 11 DIGIT No PLAN 0-2
    ITU 
    						
    							ISDN Programming - Page B2-185
    Chapter 2 - Features and Operation
    DEFAULT … BRI 11-Digit Number Plan setting is ITU.
    ISDN Programming - Page B
    Description
    When entering the ISDN attributes portion of the database, the programmer may decide to 
    enter information for a range of slots or one specific slot. Range programming lets the 
    programmer change a specific parameter or a few parameters for an entire range of slots, 
    leaving intact the remaining data fields that do not require change. Those data fields 
    continue to operate with the previously programmed data.
    Programming Steps
    1. Press FLASH and dial [45]. The following message displays:
    2. Enter a valid number for the range of slots being programmed. If only one slot is being 
    programmed, enter that number twice (02 02 = Slot 2, Cabinet 0).
    3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. 
    Flexible button #19 (Page A) is lit.
    IMPORTANT --
    These timers should not be adjusted UNLESS working with Technical Support or your 
    telephone company.
    MAX # OF
    RETRANSMISSIONSMAX
    OCTETSMAX TEI
    RQSTMAX XID
    RETRANSMISSION
    1Q2W3E4R
    T-200MIN TEI ID
    CHK MSGMIN TEI
    ID RQSTMSG EXCHANGE
    TIMER
    5T6Y7U8I
    MIN XID
    RETRANSMINTER-DIGIT
    T/OSET UP
    TIMERDISCONNECT
    TIMER
    9O10 P11 A12 S
    RELEASE
    REQUESTLINK
    DISCONNECTCALL
    PROCEEDINGCONNECT
    REQUEST
    13 D14 F15 G16 H
    RESTART
    REQ TIMERPAGE APAGE B
    17 J18 K19 L20 ;
    PAGE CPREVIOUSNEXTNEW RANGE
    21 Z22 X23 C24 V
    ISDN  ATTRIBUTES
    SELECT  A  SLOT  RANGE 
    						
    							2-186ISDN Programming - Page B
    Chapter 2 - Features and Operation
    4. Press button #20 to select Page B. The following message displays to indicate current 
    programming of that slot or group of slots:
    XY-XY = Slot Range
    X = Cabinet (0, 1, 2)
    Y = Slot (0-8)
    NOTE -- Slot 8, Cabinet 0 is reserved for the MISB
    Maximum Number Retransmission
    Description
    The Maximum Number of Retransmissions of a frame (N200) is a system parameter. Do not 
    change the Maximum Number Retransmission setting unless advised to do so by Technical 
    Support.
    Programming Steps
    1. Press the MAX # RETRANSMSN flexible button (FLASH 45, Page B, Button #1).
    2. Enter a valid number (0-9) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Maximum Number Retransmission is 3.
    Maximum Octets
    Description
    The maximum number of octets in an I-Frame/information field (N201) is a system parameter. 
    Do not change the Maximum Octets setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the MAX OCTETS flexible button (FLASH 45, Page B, Button #2).
    2. Enter a valid number (000-999) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    (000 = Disable)
    DEFAULT … Maximum Octet setting is 260.
    XY - XY  PAGE  B
    ENTER  BUTTON  NUMBER
    MAX  #  RETRANSMSN 0-9
    N200    3
    MAX  OCTETS 000-999
    N201    260 
    						
    							ISDN Programming - Page B2-187
    Chapter 2 - Features and Operation
    Maximum TEI Request
    Description
    This feature is reserved for future use.
    Programming Steps
    1. Press the MAX TEI RQST flexible button (FLASH 45, Page B, Button #3).
    2. Enter a valid number (000-999) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Maximum TEI Request setting is 003.
    Maximum XID Retransmission
    Description
    Do not change the Maximum number of XID Retransmissions setting unless advised to do so 
    by Technical Support.
    Programming Steps
    1. Press the MAX XID RETRANSMISSION flexible button (FLASH 45, Page B, Button #4).
    2. Enter a valid number (0-9 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Maximum XID Retransmission setting is 3 seconds.
    T- 2 0 0
    Description
    The T-200 timer is used to set the time to wait for an I-Frame acknowledgement. Do not 
    change the T-200 timer setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the T-200 flexible button (FLASH 45, Page B, Button #5).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … T200 setting is 1 second.
    MAX  TEI   RQST 000-999
    N202    003
    MAX  XID  RETRANSMSN 0-9
    N204    3
    T200 00-99
    01    
    						
    							2-188ISDN Programming - Page B
    Chapter 2 - Features and Operation
    Minimum TEI ID Check Message
    Description
    The Minimum TEI ID Check Message feature sets the minimum time between retransmission 
    of the TEI identity check messages. Do not change the Minimum TEI ID Check Message 
    setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the MIN TEI ID CHK MSG flexible button (FLASH 45, Page B, Button #6).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Minimum TEI ID Check Message setting is 1 second.
    Minimum TEI ID Request
    Description
    This feature is reserved for future use.
    Programming Steps
    1. Press the MIN TEI ID RQST flexible button (FLASH 45, Page B, Button #7).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Minimum TEI ID Request setting is 2 seconds.
    Message Exchange Timer
    Description
    The Message Exchange Timer setting establishes the maximum time allowed without frames 
    being exchanged. Do not change the Message Exchange Timer setting unless advised to do 
    so by Technical Support.
    MIN  TEI ID  CHK  MSG 00-99
    T201    01
    MIN  TEI ID  RQST MSG 00-99
    T202    02 
    						
    							ISDN Programming - Page B2-189
    Chapter 2 - Features and Operation
    Programming Steps
    1. Press the MSG EXCHANGE TIMER flexible button (FLASH 45, Page B, Button #8).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Message Exchange Timer setting is 15 seconds.
    Minimum XID Retransmission
    Description
    The Minimum XID Retransmission setting establishes the minimum time between XID 
    messages. Do not change the Minimum XID Retransmission setting unless advised to do so 
    by Technical Support.
    Programming Steps
    1. Press the MIN XID RETRANSMSN flexible button (FLASH 45, Page B, Button #9).
    2. Enter a valid number (0-9 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Minimum XID Retransmission setting is 3 seconds.
    Inter-Digit T / O
    Description
    Do not change the Inter-digit time out setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the INTER-DIGIT T/O flexible button (FLASH 45, Page B, Button #10).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Inter-digit Timeout setting is 25 seconds.
    MSG  EXCHANGE  TIMER 00-99
    T203    15
    MIN  XID  RETRANSMSN 0-9
    T204    3
    INTER-DIGIT T/O 00-99
    T302    25 
    						
    							2-190ISDN Programming - Page B
    Chapter 2 - Features and Operation
    Set-Up Timer
    Description
    The Set-up Timer setting establishes the response time to setup message. Do not change the 
    Set-up Timer setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the SET UP TIMER flexible button (FLASH 45, Page B, Button #11).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Set-up Timer setting is 10 seconds
    Disconnect Timer
    Description
    The Disconnect Timer setting establishes the response time to a disconnect message. Do not 
    change the Disconnect Timer setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the DISCONNECT TIMER flexible button (FLASH 45, Page B, Button #12).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Disconnect Timer setting is 4 seconds.
    SETUP  TIMER 00-99
    T303    10
    DISCONNECT  TIMER 00-99
    T305 04 
    						
    							ISDN Programming - Page B2-191
    Chapter 2 - Features and Operation
    Release Request
    Description
    Do not change the Release Request setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the RELEASE REQUEST flexible button (FLASH 45, Page B, Button #13).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Release Request Timer setting is 4 seconds.
    Link Disconnect
    Description
    Do not change the Link Disconnect Timer setting unless advised to do so by Technical 
    Support.
    Programming Steps
    1. Press the LINK DISCONNECT flexible button (FLASH 45, Page B, Button #14).
    2. Enter a valid number (20-30 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Link Disconnect setting is 30 seconds.
    Call Proceeding
    Description
    Do not change the Call Proceeding setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the CALL PROCEEDING flexible button (FLASH 45, Page B, Button #15).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Call Proceeding setting is 60 seconds.
    RELEASE  REQUEST 00-99
    T308    04
    LINK  DISCONNECT 20-30
    T309    30
    CALL PROCEEDING 00-99
    T310    60 
    						
    							2-192ISDN Programming - Page B
    Chapter 2 - Features and Operation
    Connect Request
    Description
    Do not change the Connect Request Timer setting unless advised to do so by Technical 
    Support.
    Programming Steps
    1. Press the CONNECT REQUEST flexible button (FLASH 45, Page B, Button #16).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Connect Request setting is 4 seconds.
    Restart Request Timer
    Description
    Do not change the Restart Request Timer setting unless advised to do so by Technical 
    Support.
    Programming Steps
    1. Press the RESTART REQ TIMER flexible button (FLASH 45, Page B, Button #17).
    2. Enter a valid number (0-200 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT … Restart Request Timer setting is 120 seconds.
    CONNECT REQUEST 00-99
    T313    04
    RESTART  REQ  TIMER 0-200
    T 3 16 120 
    						
    All Triad manuals Comments (0)

    Related Manuals for Starplus Triad Xts Digital Key Telephone System System Programming And Operation Manual