Home
>
Triad
>
Telephone
>
Starplus Triad Xts Digital Key Telephone System System Programming And Operation Manual
Starplus Triad Xts Digital Key Telephone System System Programming And Operation Manual
Have a look at the manual Starplus Triad Xts Digital Key Telephone System System Programming And Operation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 9 Triad manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
About This Manual2-3 Chapter 2 - Features and Operation Manual Format & Description This diagram explains how the Features/Operations are organized in the following chapters and appendices. The manual format follows the basic outline as shown, but omits those elements that do not apply to a particular Feature or Operation. Feature / Operation Narrative to explain the feature/operation. Sub-Feature / Operation Description Narrative to explain the sub-feature/operation. Related Information Programming Steps Consists of those actions required of a system administrator to program single or multiple phones in the system or system features using a 24-button digital telephone. This section assumes that you have already entered database administrative programming using the string of [ ][][3][2][2][6] (default password). DEFAULT … Shows the system default setting. Operation Describes how the user operates the digital telephone. ELECTRONIC TELEPHONE When the Electronic Telephone operation differs from digital, those differences are described. SINGLE LINE TELEPHONE When the Single Line Telephone operation differs from the digital telephone, those differences are described. Conditions » Describes any special criteria that affects the programming or operation of the feature. Quick Reference Flash XX Button X The xxxx function MUST also be enabled.
2-4911 Feature Chapter 2 - Features and Operation 911 Feature Description The 911 Feature allows stations in the system to dial 911 without using an access code. 911 calls are placed on 911 marked lines. If all lines are busy, an existing call is dropped and the 911 call is placed. When this feature is enabled, Trunk Group/LCR Access Code 9 is not available. Related Information Programming Steps To enable/disable the 911 feature: 1. Press the 911 FEATURE flexible button (FLASH 06, Button #13). The following message displays: 2. Enter a 0 or 1 on the dial pad to enable/disable the use of this feature. [0] = Disabled [1] = Enabled DEFAULT … Disabled To designate the line(s) for 911 use: 1. Press FLASH and dial [40]. The following message displays: 2. Enter a valid number for the range of lines being programmed. If only one line is being programmed, enter that number twice (001 001). Quick Reference Flash 12 To insert [9] for Centrex 911 calls (Refer to “PBX Dialing Codes” on page 2-57.) 911 FEATURE 0-1 DISABLED CO LINE ATTRIBUTES SELECT A CO LINE RANGE If HOLD is pressed without entering a CO range, ALL CO lines are selected.
911 Feature2-5 Chapter 2 - Features and Operation 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. Flexible button #19 (Page A) is lit. The following message displays to indicate current programming of that line or group of lines: XXX-XXX = CO Line Range 4. Press Button #15 to designate the line for 911 use. 5. Enter a 0 or 1 on the dial pad to enable/disable this feature. [0] = Disabled [1] = Enabled 6. Press HOLD to save the entry. A confirmation tone sounds and the display updates. DEFAULT … Disabled 911 Alert Description Any station user or attendant who programs a flexible button for 911 ALERT (feature code 608) will be alerted of internal stations placing 911 calls. The system can store the sixteen most recent 911 calls. Calling information includes the time/date of the call, as well as the station number from which the call was placed. The initial 911 Alert indications include: Audible ringing tone Green flashing 911 ALERT flexible button LED Automatic LCD display of 911 call information XX = Index number (01-16) XXX - XXX PAGE A ENTER BUTTON NUMBER 911 TRUNK 0-1 DISABLED E911 CALL XX: STA XXXX MM/DD/YY HH:MM
2-6911 Feature Chapter 2 - Features and Operation Operation Station users and attendants can press the 911 ALERT flexible button as necessary to view additional 911 calls’ information in the stored list. After a station user or attendant views the information for all 911 calls in the system list: All users’ LEDs change to a solid red indication. The audible ringing tone at all stations ceases. The LCDs at all stations revert to a normal display. The list remains available for review by pressing the 911 ALERT flexible button as necessary, until after the messages are deleted. To delete logged 911 Alert messages: An attendant uses the following steps to delete the messages on a system-wide basis. 1. Press the 911 ALERT flexible button to display the 911 call information for deletion. 2. Press FLASH to delete that message. Enhanced 911 Integration Description The E911 feature integrates the system to the Proctor PBX ANI-LINK product to provide enhanced 911 service. Loop Start lines can be connected to the Proctor unit and programmed to be 911 lines (FLASH 40, Page A, Button #15). When a 911 call is made from a station in the system, the system will send 911XXXX (XXXX=Station # that placed the 911 call) in DTMF format to the Proctor. If the station number is less than 4 digits, a leading 0 will automatically be added. The Proctor unit then accesses a call trunk and sends the information in the proper format to the 911 Center. This feature also provides a means to identify a power failure signal from the Proctor Unit. If a power failure signal is detected, the KSU routes 911 calls via trunks other than those marked for 911 use until the signal is removed. Programming Steps 1. Press the ENHANCED 911 button (FLASH 06, Button #14). The following message displays: 2. Enter a 0 or 1 on the dial pad to enable/disable the use of this feature. [0] = Disabled [1] = Enabled The E911 feature ensures access to 911 by freeing a CO Line, then making a call. If you are using Centrex lines, a 2-second setting is recommended for Guard Timer programming (Flash 40, Page C, Button #6). This avoids situations where a line is seized by the 911 call before an existing call is dropped, causing the emergency call to be conferenced with the existing call. ENHANCED 911 0-1 DISABLED
911 Feature2-7 Chapter 2 - Features and Operation DEFAULT … Disabled Conditions » The 911 Feature (FLASH 06, Button #13) must also be enabled for the Proctor Integration to work. » Only the lines connected to the Proctor should have the 911 Enable programmed (FLASH 40, Page A, Button #15). » It is recommended to have a power failure procedure in place to ensure that 911 calls are always routed. Refer to FLASH 09, Button #7 for programming information. Enhanced 911 Power Failure Station Description The power failure signal is designed to be used with the normally open (NO) power failure leads from the Proctor unit connected to an SLT port or SLA device. When the leads close in power failure, this is detected as an off hook and 911 routing ceases to the Proctor unit. 911 calls are sent via trunks other than those marked for 911 use until the power failure lead opens, which is detected as an on hook. 911 calls are then routed again to the Proctor unit. Programming Steps 1. Press the E911 POWER FAILURE STATION button (FLASH 09, Button #7). The following message displays: 2. Enter a valid SLT station number (100-8999) to be used as the power failure station. 3. Press HOLD to save the entry. A confirmation tone sounds. Conditions » During a power failure, 911 calls are sent via trunks other than those marked for 911. » During a power failure, the station’s digit information is not sent. » The feature requires either an SLT port or an SLA port for the integration to work. PROCTOR 911 P/F #### ####
2-8Account Code Chapter 2 - Features and Operation Account Code Description An account code is the last field within Station Message Detail Recording (SMDR), that provides tracking capabilities for specific calls by entering a verified/non-verified, variable length (up to 12 digits) identifier. The use of forced Account Codes is optional, offered on a system-wide basis. SMDR must be enabled to use account codes. Related Information Operation When connected to an outside line call: 1. Press the preprogrammed ACCOUNT CODE button (feature code 627 - refer to “Flexible Button Assignment” on page 2-148). 2. Dial account code up to 12 digits. ( The other party does not hear the digits being dialed). If account code is less than 12 digits, an [] must be entered to return to the call. If account codes are forced, the account code must be entered prior to dialing the outside number. Account Codes - Forced Description The XTS allows arranging of the system so that station users must enter an account code before placing an outside call. Account codes can also be used as a Traveling Class-of-Service to upgrade a restricted station’s class-of-service for unrestricted dialing. Account codes must be entered before the call when forced. The system can force account codes on all restricted calls. When the Forced Account Code option is enabled, and the account code is entered, a station’s Class of Service is upgraded to day COS1, night COS1. If option is disabled, a station’s COS is not upgraded but the account code continues to be part of the SMDR record. Quick Reference Flash 2 1 Button 1 The SMDR func tion MUST be enabled (R efer to “SMDR Enable / Disable” on page 2-271.) SMDR must be enabled for the Account Code feature to operate. Also, SMDR must be enabled for the account code to become part of the SMDR record.
Account Code2-9 Chapter 2 - Features and Operation Programming Steps 1. Press ACCOUNT CODES flexible button (FLASH 05, Button #8) to determine whether the use of Account Codes is forced or optional. 2. Enter a 0 or 1 that corresponds with the following entries: [0] = Disabled [1] = Enabled 3. Press HOLD to save the entry. A confirmation tone sounds. DEFAULT … Account Codes are optional. Operation Prior to placing an outside line call: 1. Press the preprogrammed ACCOUNT CODE button. 2. Dial account code up to 12-digits. SINGLE LINE TELEPHONE To enter an Account Code before a call: 1. Lift the handset. 2. Dial [627]. 3. Dial the account code. 4. Dial [9] or CO Access code. Dial tone sounds. 5. Dial the desired number. To enter an Account Code during a call: 1. Depress the hookswitch momentarily. Your call will be placed on executive hold while you enter your account code. 2. Dial [627]. 3. Dial the account code. FORCED ACCOUNT CODE 0-1 DISABLED SMDR must be enabled for the Account Code feature to operate. Also, SMDR must be enabled for the account code to become part of the SMDR record. Refer to “SMDR Enable / Disable” on page 2-271. If the account code contains fewer than 12 digits, dial [] to return to the intercom dial tone. If the account code contains fewer than 12 digits, dial [] to automatically return to the call.
2-10Account Code Chapter 2 - Features and Operation Account Codes - Traveling COS ( Verified) Description The Verified Account Code/Traveling Class of Service (COS) feature provides the ability to track specific calls by entering a verified, variable length (up to 12 digits) identifier. Each account code can be assigned a day and night Class of Service for determining the dialing privileges allowed by that account code. This feature provides a means for users to override a restricted station. If the dialed account code matches the Verified Account code table, an intercom dial tone is returned, otherwise an error tone is presented. Using verified Account Codes is optional, available on a system-wide basis. SMDR must be enabled for the account code to print as part of the SMDR record. The XTS allows up to 250 12-digit account codes for verification purposes. Figure 2-1: FLASH 31 Button Mapping Related Information Programming Steps To enable or disable Verified Account Codes: 1. Press the VERIFIED ACCT CODES flexible button (FLASH 06, Button #3). The following message displays: 2. Enter 0 or 1 on the dial pad to enable/disable Verified Account Codes. [0] = Disabled [1] = Enabled ACCT CODECLASS OF SERVICEDELETE ACCT CODEERASE DIGITS 1Q2W3E4R 5T6Y7U8I 9O10 P11 A12 S 13 D14 F15 G16 H NEXTPREV 17 J18 K19 L20 ; 21 Z22 X23 C24 V Quick Reference Flash 21 Button 1 The SMDR function MUST be enabled (Refer to “SMDR Enable / Disable” on page 2-271.) VERIFIED ACCT CODES 0-1 DISABLED
Account Code2-11 Chapter 2 - Features and Operation 3. Press HOLD to save the entry. A confirmation tone sounds. DEFAULT … Verified Acct Codes are disabled. To assign Verified Account Codes: 1. Press FLASH and dial [31]. The following message displays: ACCT = Up to 12-digit account code COS = Class of Service for account codes 2. Press the ACCT CODE flexible button (FLASH 31, Button #1). Enter up to 12 digits (0-9, *, #). [*] represents a do not care digit. The system ignores all digits after this digit when entering an account code. The [#] represents a single do not care digit. 3. Press the CLASS OF SERVICE flexible button (FLASH 31, Button #2). Enter a 2-digit Class of Service Number (1-7) that corresponds to Class of Service 1-7. The first digit represents Day COS and the second digit represents Night COS. 4. Press HOLD to complete the entry. A confirmation tone sounds. DEFAULT … No Account Codes are assigned. To delete the currently displayed Verified Account Code: 1. Press the DELETE CODE flexible button (FLASH 31, Button #3) to delete the entire account code entry. 2. To display the next account code on the LCD, press the NEXT flexible button (FLASH 31, Button #18). 3. To display the previous account code on the LCD, press the PREVIOUS flexible button (FLASH 31, Button #19). To erase previously entered digits: 1. Press the ERASE DIGITS flexible button (FLASH 31, Button #4) 2. Each press of the button erases one digit. Continue until all desired digits are erased. 3. Re-enter the correct digits, then press HOLD to complete the entry. A confirmation tone sounds. ACCT COS XXXXXXXXXXXX ## (Refer to Figure 2-1 on page 2-10 for FLASH 31 button mapping.) Existing account code entries display in numerical order from lowest to highest. If an existing account code displays on the LCD when FLASH 31 is initially entered, the programming procedure creates a new account code, but does not delete the account code initially shown. If the intent is to change an existing account code from one number to another, perform the assignment procedure and delete the undesired account code entry by following the procedure in the following section.
2-12Account Code Chapter 2 - Features and Operation Operation To use Verified Account Codes: 1. Press preprogrammed ACCOUNT CODE button before accessing a CO line. 2. Dial the account code up to 12-digits. If the account code matches a verified account code, intercom dial tone is returned. Otherwise an error tone is presented. 3. Access the outside CO line or dial the LCR code and dial the desired number. SINGLE LINE TELEPHONE To enter an Account Code before a call: 1. Lift the handset. 2. Dial [627]. 3. Dial the account code. 4. Dial [9] or CO Access code. Dial tone sounds. 5. Dial the desired number. Conditions » Verified Account Codes allow use of an account code as a traveling Class of Service. » If LCR is activated in the system and verified account codes are activated, the user must enter the account code before dialing the LCR code. » When verified account codes are activated, station MUST enter an account code to dial a number that is restricted through station COS and toll restriction. An account code is not required for calls that are unrestricted through station COS and toll restriction. » When verified account codes are not forced, a station user may place a call without entering an account code. In this case, the station users COS is based on their station COS. In this case, a user can enter a verified account code to upgrade their COS. » The Redial feature does not support Verified Account Codes. » Keyset users must preprogram an ACCOUNT CODE flexible button. SMDR must be enabled for the Account Code feature to operate. Also, SMDR must be enabled for the account code to become part of the SMDR record. If the Account Code contains fewer than 12 digits, dial [✳] to return to the intercom dial tone.