    							STAFIPLUS~ Digital Systems TF NO: 43 
    VOICE MAIL GROUPS (Cont’d) 
    A Uave” Mall Index Entry 
    Desaiptbm 
    The “Leave” mail index specifies the outpulsing Table where the ‘in-band” digits required to connect a caller, 
    forwarded into Voice Mall, to the called stations mail box are stored. Refer to Sec. 645.2 for programming entries 
    into an outpulsing table. 
    .._ 
    To delete a ‘Leave” mail index entry, enter one pound [#] in the desired location on the keypad and press the 
    HOLD button.(i.e.: Tables-l ,2,3 entered. To delete only Table 2, enter 1,#,3 and press HOLD). 
    OpeIMOIX 
    None 
    Programming: 
    To specify the “Leave” mail index (outpulsing table) to be accessed by a Voice Mail group: 
    1. Press the LEAVE flexible button (Button #lo). 
    2. Enter the three-digit “Leave” mail index on the dial pad. 
    - 1st Digit = Standard Leave Table number (O-7). 
    - 2nd Digit = Leave Table to utilize when station is forwarded to VM in a “No-Answer” condition. 
    - 3rd Digit = Leave Table to utilize when station is forwarded to VM in a “Busy” condition. 
    3. Press the HOLD button to save the entry. 
    Confirmation tone is heard and the display will now update. 
    Vodavi Communicalions Systems 
    Page 56 d 56 TF NO. 43 
    8300 E. Raintree Drive swttedaie, AZ 85260 (@a 443-6m  
    						
    							TECHNICAL FACT NOTICE 
    Starplus Dlgltal Systems 
    -TF NO: 33 
    2/l/93 
    2x4 SLT Expander Module 
    Description: 
    The 2x4 SLT Expander Module is a two CO by four single line telephone Interface module that plugs onto the main 
    key service board of the Basic KSU or the main key service board of the Expansion KSU through the use of two 
    ribbon cables. This module is a combination board that contains the necessary circuitry to connect two 
    CO/Centrex/PBX loop start lines and four single line telephones to the system. This card also contains a connector 
    for adding one application module (i.e. DTMF Receiver) to the system. 
    Message Waiting capability comes installed on the 2x4 SLT Expander Module. This circuitry provides message 
    waiting voltage to single line telephones equipped with message waiting lamps, and supports up to four single line 
    telephones message waiting lamps at 9OV dc typically across tip and ring. 
    LEDs & Indicators: Two green LEDs indicate the presence of +5V & -5V dc. An extinguished LED indicates the 
    absence of the associated voltage. 
    CO Llne/Statlon Interfaces: The 2x4 SLT Expander Module provides the interface for two Central Office, Centrex 
    or PBX loop start, lines. The protection circuitry necessary to allow the system to be classified as a fully protected 
    system are located on the card for each CO circuit. The CO circuits are equipped with current sensing circuitry that 
    identifies distant end disconnect (loop supervision). The module design also provides proper fusing or protection 
    to comply with the requirements of UL 1459 Second Edition and CSA C22.2 No. 225 standards. CO lines are 
    connected to the system via RJ-11 modular connectors mounted on the bottom edge of the board. 
    The 2x4 SLT Expander module also provides the interface for four standard on-premise single line telephones 
    (2500 type). Four 36V dc single line circuits are provided on the printed circuit board. These single line telephones 
    can be equipped with a standard message waiting lamp (9OV T&R) that operate on the “tip” and “ring” leads. 
    Additionally, each circuit may be individually optioned (software controlled) to provide a loop interrupt 
    to the 
    connected SLT or device. The card will support single line telephones up to 2000 feet from the Basic KSU. 
    On-premise single line telephones should present a load to the port totaling a maximum ringer equivalence of 2.5. 
    A molex connector (J4) is located on the 2x4 SLT Expander Module to provide ring generator capabilities. It is 
    recommended that the Tellabs 8101, 30 Hz, SOVAC Ring Generator be used with this board. 
    Vodavi Communications Systems 
    Page1 of 11 
    6300 E. Raintree Drive Scottsdale, AZ 85260 
    TF NO. 33 
    (602) 443-6000  
    						
    							STARPLUS TECHNICAL FACT NOTICE STARPLUS DIGITAL SYSTEMS 
    2 X 4 SLT EXPANDER MODULES (cont’d) 
    CO Lines Connections: 
    CO Lines are connected to the system via modular RJ-11 connectors mounted on the 
    2x4 SLT Expander Module and accessed on the bottom of the Basic KSU. The 2x4 SLT Expander Module connects 
    CO Line ports 5 and 6 (when installed on the Basic KSU) or ports 13 and 74 (when installed in the Expansion KSU) 
    to the system through modular connectors J21 and J22 respectively. The pinouts of the modular connector are as 
    follows. 
    CO1 TIP 1 1 CO1 RING 
    Figure 1 - CO 
    Lines Connectlons 
    NOTE: Currently ALL CO Line modular cables must pass through a 1.2” thick,, 2-3/a” diameter,, round ferrite core 
    fhree times prior to exiting the KSU in order to comply with FCC regulations. Up to five cables can be wrapped 
    Gd one ferrite core. 
    *If the 2x4 Station or SLT Expander Module is NOT installed in the Basic KSU and an Expansion 
    KSU is part of the system configuration, CO Ports 5-6 and Station Ports 9-12 can be re-assigned 
    Refer to Techfact Notice #TFN 27A for Flexible Port Assignment features. 
    Statlons Connectlons: The station ports of the 2x4 SLT Expander Module are wired to the main distribution frame 
    via a 25pair, (50-pin) male amphenol-type connector located on the main key service board or expansion key 
    service board, connector Jl 1. A 25-pair cable with a 50-pin female amphenol-type connector is required to extend 
    the station ports to the main distribution frame. The pinouts for the stations on the 2x4 SLT Expander Module 
    activate ports 009 through 012 on connector Jl 1 as shown in Table 1 when installed on the main key service board 
    in the Basic KSU. Also refer to Table 1 Basic KSU Jl 1 Station Connections. 
    Page 2 of 11 TF NO. 33 
    Vodavi Communications Systems 8300 E. Raintree Drive Scottsdale, AZ 65260 (602) 443-6000  
    						
    							STARPLUS TECHNICAL FACT NOTICE STARPLUS DIGITAL SYSTEMS 
    Table 1 - 2 x 4 SLT Expander Module Jll BKSU Connections 
    PAIR 
    17 
    18 
    19 
    20 
    21 
    22 
    23 
    .24 
    25 PIN COLOR 
    42 YUOR 
    17 
    OFvfL 
    43 YIJGN 
    18 GNNL 
    44 YUBN 
    19 BNNL 
    45 YUSL 
    20 SINL 
    46 VI/BL 
    21 BWI 
    47 VI/OR 
    22 OFVVI 
    48 VI/GN 
    23 GNNI 
    49 VI/BN 
    24 BNNI 
    50 VIISL 
    25 SWI DESIG 
    Port 009 SLT Tip 
    SLT Ring 
    Port 010 SLT Tip 
    SLT Ring 
    Port 011 SLT Tip 
    SLT Ring 
    Port 012 SLT Tip 
    SLT Ring 
    External Page Tip 
    External Page Ring 
    Page3of 11 TF NO. 33 
    Vodavi Communications Systems 8300 E. Raintree Drive Scottsdale, AZ 86260 (602) 443-6000  
    						
    							STARPLUS TECHNICAL FACT NOTICE 
    STARPLUS DIGITAL SYSTEMS 
    2 x 4 SLT EXPANDER MODULE (cont’d) 
    The pinouts for the stations on the 2x4 SLT Expander Module activate ports 025 through 028 on connector Jl 1 
    are shown in Table 2 2x4 SLT Expander Module Jl 1 EKSU Connections when installed on the main key service 
    board in the Expansion KSU. Also refer to Table 2 Expansion KSU Jll Station Connections. Only the Xmit Tip (SLT 
    Tip) and Xmit Ring (SLT Ring) leads are used when connecting SLT stations to the 2x4 SLT Expansion Module. 
    Table 2 - 2 x 4 SLT Expander Module Jll EKSU Connections 
    PAIR 
    I PIN 
    I COLOR 
    I DESIG 
    17 
    18 
    19 
    20 
    21 
    22 
    23 
    24 
    25 42 
    17 
    43 
    18 
    44 
    19 
    45 
    20 
    46 
    21 
    47 
    22 
    48 
    23 
    49 
    24 
    50 
    25 YUOR 
    OR/YL 
    YUGN 
    GNNL 
    YUBN 
    BNNL 
    YUSL 
    SlNL 
    VIn3L 
    BWI 
    O&l 
    VI/GN 
    GNNI 
    VI/BN 
    BNNI 
    VIISL 
    SWI Port 021 SLT Tip 
    SLT Ring 
    Port 022 SLT Tip 
    SLT Ring 
    Port 023 SLT Tip 
    SLT Ring 
    Port 024 SLT Tip 
    SLT Ring 
    External Page Tip 
    External Page Ring 
    Appllcatlon Module(s) Connections: The Ji connector on the 2x4 SLT Expander Module allows the installation 
    of one application module (i.e. DTMF receiver) to the system. Refer to Application Module(s) Installation for a 
    description of the available application modules. 
    Vodavi Communications Systems 
    Page4of 11 
    8300 E. Raintree Drive Scottsdale, AZ 85260 
    TF NO. 33 
    (602) 443-6000  
    						
    							STARPLUS TECHNICAL FACT NOTICE 
    STARPLUS DIGITAL SYSTEMS 
    Installation: 
    1. 
    2. Remove power from both the Basic KSU and Expansion KSU, if installed. 
    Locate the Meaage Waiting Module and remove the two screws holding it to the 2x4 SLT Expander 
    Module. Remove the Message Wafting Module to expose the hold down screw underneath. 
    3. Locate the J9 connector on the main service board of the Basic KSU or main key service board of the 
    Expansion KSU and the Pl connector on the 2x4 SLT Expander Module. Refer to Figure 2 Basic KSU 
    Application Card Locations. 
    4. Gently push the cable from the Pl connector on the 2x4 SLT Expander Module onto the J9 connector on 
    the main key service board of the Basic KSU or main key service board of the Expansion KSU. 
    5. Locate the JlO connector on the main key service board of the Basic KSU or main key service board of 
    the Expansion KSU and the P2 connector on the 2x4 SLT Expander Module. Refer to Figure 500-18 Basic 
    KSU Application Card Locations. 
    6. Gently push the cable from the P2 connector on the 2x4 SLT Expander Module onto the JlO connector 
    on the main key service board of the Basic KSU or main key service board of the Expansion KSU. 
    7. Secure the four screws attached to the 2x4 SLT Expander module to the main key service board of the 
    Basic KSU or main key service board of the Expansion KSU. 
    8. Re-install the Message Waiting Module and secure it with the two mounting screws. 
    9. Restore power to both the Basic KSU and Expansion KSU, if installed. 
    Page5of 11 TF NO. 33 
    Vodavi Communications Systems 8300 E. Raintree Drive Scottsdale, AZ 85260 (602) 443-6000  
    						
    							J 
    ’ 
    STARPLUS TECHNICAL FACT NOTICE STARPLUS DIGITAL SYSTEMS 
    DSI 0 
    DS2 0 
    0 
    1 
    Pl 
    _ _ _ _ _ _ - - - _ - 
    Figure 2 - 2 x 4 SLT Expander Module 
    Page6of 11 TF NO. 33 
    Vodavi Communications Systems 8300 E. Raintree Drive Scottsdale, AZ 85260 (602) 443-6000  
    						
    							STARPLUS TECHNICAL FACT NOTICE 
    STARPLUS DIGITAL SYSTEMS 
    4x8 SLT Interface Board (CSB) 
    Description: 
    The 4x8 SLT Interface Board (CSB) is a four CO Line by eight single line telephone interface board. The card is 
    a combination card that contains the necessary circuitry to connect four CO/Centrex/PBX loop start lines and eight 
    standard on-premise single line telephones (2500 type) to the system. This card also contains one additional voice 
    (transmit) path for external paging and a connector for adding one application module (i.e. DTMF Receiver or Dual 
    DTMF/Taik-Back Page Module) to the system. The 4x8 SLT interface Board can be removed or inserted with power 
    on the KSU. Refer to Figure 5 Basic KSU Equipment Cabinet for component layout and location of connectors. 
    A moiex connector is located on the 4x8 SLT Interface Board (CSB) to provide ring generator capabilities. It is 
    recommended that the Teiiabs 8101, 30 Hz, SOVAC Ring Generator be used with this board. 
    NOTE: Only one Ring Generator is required per system. At least one DTMF Receiver MUST be installed in the 
    system. 
    Message Waiting capability is installed onto the 4x8 SLT interface Board. This circuitry provides message waiting 
    lamps to single line telephones equipped with message waiting lamps, and supports up to eight single line 
    telephone Message Waiting lamps at 9OV ac typically across tip and ring. 
    LEDs & indicators: Five red LEDs are located along the front edge of the 4x8 SLT interface Board, one for each 
    CO Line to indicate when it is in use and one LED that monitors the contact operation of the multi use relay located 
    on the board. Two green LEDs also located along the front edge of the 4x8 SLT Interface Board (CSB) indicate 
    the presence of +5V & -5V dc. 
    CO Line/Station Interfaces: The 4x8 SLT interface Board (CSB) provides the interface for four Central Office, 
    Centrex or PBX loop start,, lines. The protection circuitry necessary to allow the system to be classified as a fully 
    protected system are located on the card for each CO circuit. The CO circuits are equipped with current sensing 
    circuitry that identifies distant end disconnect (loop supervision). The card also provides proper fusing or protection 
    to comply with the requirements of UL 1459 Second Edition and CSA C22.2 No. 225 standards. The 4x8 SLT 
    interface Board does not support data devices for data switching. 
    The 4x8 SLT Interface Board (CSB) provides the control and interface for eight standard single line telephones 
    (2500 type). Eight 36V dc single line circuits are provided on the printed circuit board. These single line telephones 
    can be equipped with a standard Message Waiting Lamp (9OV T & R) that operate on the “tip” and “ring” leads. 
    Additionally each circuit may be individually “optioned” (software controlled) to provide a loop interrupt to the 
    connected SLT or device. The card will support single line telephones up to 2000 feet from the Basic KSU cabinet. 
    On-premise single line telephones should present a load to the port totaling a maximum ringer equivalence of 2.5. 
    Page7of 11 TF NO. 33 
    Vodavi Communications Systems 6300 E. Raintree Drive Scottsdale, AZ 65260 (602) 443-6000  
    						
    							STARPLUS TECHNICAL FACT NOTICE 
    STARPLUS DIGITAL SYSTEMS a 
    4 x 8 SLT EXPANDER MODULES (cont’d) 
    . 
    CO Lines Connections: CO Lines are connected to the system via modular RJ-14 connectors mounted to the 
    front edge of the 4x8 SLT Interface Board and accessed through the bottom of the Basic KSU cabinet. Each 4x8 
    SLT Interface Board connects four CO Line ports to the system through modular connectors J2 and J3 found on 
    each card. The pinouts of the modular connector are as follows: 
    4x8 SLT Interlace Board (CSS) W-14 Modular Jack Pinout 
    Flgure 3 - 4 x 8 SLT Interface Board 
    (CSB) RJ-14 Modular Jack Plnout 
    NOTE: Currently ALL CO Line modular cables must pass through a 1.2” thick,, 2-3/8” diameter,, round ferrite core 
    three times prior to exiting the KSU in order to comply with FCC regulations, Up to five cables can be wrapped 
    around one ferrite core. 
    c-tomour~ 
    m 4X8 in- cd 
    ‘Q::.. 
    “:::;; 
    ..:::., 
    .: . ...:,, ‘7. 
    b ..,:,, ‘.. 
    hull RJ,,cj& .:.:.: .:...:,:,:., “‘” k”r*m~ 
    m MOF 
    Vodavi Communications Systems 
    Page8of 11 
    8300 E. Raintree Drive Scottsdale, AZ 85260 
    TF NO. 33 
    (602) 443-6000  
    						
    							STARPLUS TECHNICAL FACT NOTICE STARPLUS DIGITAL SYSTEMS 
    0 
    $ 
    Station 
    0 Connects 
    Message 
    Wait 
    Circuitry 
    (FUTURE) 
    Optional- 
    Dual DTMF/ 
    Talk-Back Page 
    Module 
    _------- Jqg# ----------- 
    Optional 
    Single DTMF 
    Receiver 
    Module 
    514 
    I I 
    CJJ Pin #1 (blue) - N/C 
    1 Pin #2 (black) +f?i~@- 
    1 
    I 1 Pin #3 (red) - Ring I 
    I 
    I 
    I 
    C-5 1 Pin #4 (green) - Tip 1 
    Pin #5 (yellow) Gp-% 
    I 
    Pin #6 (brown) - N/C 
    4x8 SLT Interface Board RJ-14 Modular Jack Pinouts 
    Figure 5 - 4 x 8 SLT Interface Board (CSB) 
    Page 9 of 11 TF NO. 33 
    Vodavi Communications Systems 8300 E. Raintree Drive Scottsdale, AZ 65260 (662) 443-6000  
    						