LCR PROGRAMMING (Cont’d) L. Default LCR Data Base Programming Steps Description In an effort to decrease installation and set up time, usually associated with LCR, a default LCR data base has been incorporated. The default LCR data base will provide basic routing for local and long distance dialing. Default entries have been made in the Three Digit Table for local office codes (NNX’s) and all area codes (NPA’s). Two routes have been established with the default data base for routing of all calls under default. The entire default data base is shown in Table 665.7. The three digit tables contain a default where all Long distance (numbers requiring an area code) with a leading digit “1” are routed to Route table 00. Route Table 00 will route calls on lines in group 1 for all time periods. All Local calls (numbers that are dialed without an area code) with or without a leading digit “1’ are routed to route list table 01. Route list table 01 also routes calls using lines in line group 1 for all time periods. 655-l 2 Issue 1, November 1991
sTARPLUS@ SPD 1428 & 2856 Digital Key Telephone Systems SECTION 660 - INITIALIZE DATA BASE PARAMETERS A. Introduction Programming Steps If the system is in the programming mode, continue using the program codes. If starting to program here, enter the programming mode. (Refer to Sec. 600.2). If Data Base Parameters need to be initialized: 1. Press FLASH and dial [80]. The following mes- sage will be shown on the display of a display phone: Description This section describes the procedures and steps necessary to initialize the system data base retum- ing any programmed data to its original or default value. The entire system data base may be initial- ized or various portions of the data base may be individually initialized. In addition to initialization of the entire data base, a system reset (Button 8) command is also included in this section for clearing meantime errors. The buttons on the programming terminal are de- fined as shown below when initializing or resetting the system data base. Issue 1, November 1991 660-l
Digital Key Telephone Systems sTARPLUS@ SPD 1428 & 2866 Initialize Data Base Parameters B. Initialize System Parameters Programming Steps If System Parameters need to be initialized: 1. Press the System Parameters flexible button (Button #l). The following message will be shown on the display phone: Description The system parameters may be initialized setting all data fields to their original, default values. The fol- lowing data fields are returned to their default values upon initializing the System parameters; 2. To initialize the system parameters, press the HOLD button. Confirmation tone is heard. 666-2 Issue 1, November 1991
Initialize Data Base Parameters (Cont’d) Initialize System Parameters (Cont’d) , Programming Steps Description Issue 1, November 1991 660-3
Digital Key Telephone Systems sTARPLUS@ SPD 1428 & 2656 Initialize Data Base Parameters (Cont’d) C. initialize CO Line Attributes Programming Steps If CO tine Attributes need to be initialized: 1. Press the CO Line Attributes flexible button (Button #2). The following message will be shown on the display phone: Description The CO Line parameters may be initialized setting all data fields to their original, default values. The following data fields are returned to their default value upon initializing the CO Line parameters; 2. To initialize the CO Line Attributes, press the HOLD button. Confirmation tone will be heard. DEFAULT VALUE 660-4 Issue 1, November 1991
sTARPLUS@ SPD 1428 & 2858 Digital Key Telephone Systems Initialize Data Base Parameters (Cont’d) D. Initialize Station Attributes Programming Steps If Station Attributes need to be initialized: 1. Press the Station Attributes flexible button (But- ton #3). The following message will be shown on the display phone: Description The Station parameters may be initialized setting all data fields to their original, default values. The fol- lowing data fields are returned to their default value upon initializing the Station parameters; 2. To initialize the Station Attributes, press the HOLD button. Confirmation tone will be heard. Off-Hook Preference Issue 1, November 1991 660-5
Digital Key Telephone Systems sTARPLUS@ SPD 1428 & 2868 1 ZAMP ON DND CONF HTP 7, r SPKRVOL FUNGVOL Figure 660-l Default Button Mapping 660-6 Issue 1, November 1991
Initialize Data Base Parameters (Cont’d) E. Initialize Group Parameters Programming Steps If Group Parameters need to be initialized: 1. Press the Group Parameters flexible button (Button #4). The following message will be shown on the display phone: Description Hunt, UCD and Voice Mail Group parameters may be initialized setting all data fields to their original, default values. The following data fields are returned to their default value upon initializing Group parame- ters: 2. To initialize the Group parameters, press the HOLD button. Confirmation tone will be heard. PROGRAMCODE FLEX BUT-TON FEATURE DEFAULT VALUE (after initializing) FLASH 30 l-8 Hunt Groups 330337 No Hunt Groups established 9 Station or Pilot Hunting All Hunt Groups default using Pilot Hunting FLASH 60 1-8 UCD Groups 550-557 No UCD groups established 9 Alternate UCD Group Assign No UCD Alternates group assignments is made 10 I Overflow Assignment 1 No Overflow assignment is made 11 1 UCD Station Assignments No stations are assigned 12 Announcement Table Assign No RAN tables are specified 1 UCD Ring Timer 060seconds 2 UCD Message Interval Timer 060 seconds 3 UCD Overflow Timer 060seconds 4 UCD Wrap-Up Timer 004seconds 5 UCD No Answer Timer 000 seconds (disabled) 1-2 RAN Tables 1 and 2 No RAN parameters set FLASH 61 FLASH 62 FLASH 65 1-8 Voice Mail Groups 440447 No Voice Mail groups are established 9 Alternate VM Group Assign No Alternate VM group assignmeni is made 10 Leave Table No outpulsing table is referenced FLASH 66 11 Retrieve Table No outpulsing table is referenced 12 VM Station Assignments NO stations are assigned l-7 Voice Mail Out-Pulsing Tables Out-pulse tables are empty for in-band signaling by default 8 Voice Mail Disconnect Table Disconnect table is empty FLASH 67 1 In-Band Digits for Incoming CO Calls Disabled by default I Issue 1, November 1991 660-7
Initialize Data Base Parameters (Cont’d) F. Initialize Toll Tables Programming Steps If Exception Tables need to be initialized: 1. Press the Toll Tables flexible button (Button #5). The following message will be shown on the display phone: Description The Toll Table parameters including the Allow/Deny Tables and the Special Tables may be initialized setting all tables to their original, default values. The following Tables are cleared returning to their default value upon initializing the Exception Tables parame- , 2. To initialize the Toll Tables, press the HOLD button. Confirmation tone will be heard. TABLE DEFAULT VALUE (after initializing) ALLOW TABLE - A Table Cleared (no entries DENY TABLE - A Table Cleared (no entries) ALLOW TABLE - B Table Cleared (no entries) DENY TABLE - B Table Cleared (no entries) SPECIAL TABLE Table Cleared (no entries allowed, no 1 area code specified) SPECIAL TABLE Table Cleared (no entries allowed, no 2 area code specified) SPECIAL TABLE Table Cleared (no entries allowed, no 3 area code specified) SPECIAL TABLE 4 Table Cleared (no entries allowed) 666-6 Issue 1, November 1991
STARPLUS@ SPD 1428 & 2856 Digital Key Telephone Systems Initialize Data Base Parameters (Cont’d) G. Initialize System Speed Programming Steps Description If System Speed bins need to be initialized: 1. Press the System Speed flexible button (Button #6). The following message will be shown on the display phone: 2. To initialize the System Speed bins, press the HOLD button. Confirmation tone will be heard. Numbers entered into the System Speed dial Table may be initialized clearing all bins to their original, default value (empty). All bins 20 through 99 are cleared returning to their default value (empty) upon initializing the Speed Dial Table. Issue 1, November 1991 660-9