    							LCR PROGRAMMING (Cont’d) 
    L. Default LCR Data Base 
    Programming Steps Description 
    In an effort to decrease installation and set up time, 
    usually associated with LCR, a default LCR data 
    base has been incorporated. The default LCR data 
    base will provide basic routing for local and long 
    distance dialing. Default entries have been made in 
    the Three Digit Table for local office codes (NNX’s) 
    and all area codes (NPA’s). Two routes have been 
    established with the default data base for routing of 
    all calls under default. The entire default data base 
    is shown in Table 665.7. 
    The three digit tables contain a default where all 
    Long distance (numbers requiring an area code) with 
    a leading digit “1” are routed to Route table 00. 
    Route Table 00 will route calls on lines in group 1 for 
    all time periods. All Local calls (numbers that are 
    dialed without an area code) with or without a leading 
    digit “1’ are routed to route list table 01. Route list 
    table 01 also routes calls using lines in line group 1 
    for all time periods. 
    655-l 2 Issue 1, November 1991  
    						
    							sTARPLUS@ SPD 1428 & 2856 
    Digital Key Telephone Systems 
    SECTION 660 
    -  INITIALIZE DATA BASE PARAMETERS 
    A. Introduction 
    Programming Steps 
    If the system is in the programming mode, continue 
    using the program codes. If starting to program here, 
    enter the programming mode. (Refer to Sec. 600.2). 
    If Data Base Parameters need to be initialized: 
    1. Press FLASH and dial [80]. The following mes- 
    sage will be shown on the display of a display 
    phone: Description 
    This section describes the procedures and steps 
    necessary to initialize the system data base retum- 
    ing any programmed data to its original or default 
    value. The entire system data base may be initial- 
    ized or various portions of the data base may be 
    individually initialized. In addition to initialization of 
    the entire data base, a system reset (Button 8) 
    command is also included in this section for clearing 
    meantime errors. 
    The buttons on the programming terminal are de- 
    fined as shown below when initializing or resetting 
    the system data base. 
    Issue 1, November 1991 660-l  
    						
    							Digital Key Telephone Systems sTARPLUS@ SPD 1428 & 2866 
    Initialize Data Base Parameters 
    B. Initialize System Parameters 
    Programming Steps 
    If System Parameters need to be initialized: 
    1. Press the System Parameters flexible button 
    (Button #l). The following message will be 
    shown on the display phone: Description 
    The system parameters may be initialized setting all 
    data fields to their original, default values. The fol- 
    lowing data fields are returned to their default values 
    upon initializing the System parameters; 
    2. To initialize the system parameters, press the 
    HOLD button. Confirmation tone is heard. 
    666-2 
    Issue 1, November 1991  
    						
    							Initialize Data Base Parameters (Cont’d) 
    Initialize System Parameters (Cont’d) 
    , 
    Programming Steps Description 
    Issue 1, November 1991 660-3  
    						
    							Digital Key Telephone Systems sTARPLUS@ SPD 1428 & 2656 
    Initialize Data Base Parameters (Cont’d) 
    C. initialize CO Line Attributes 
    Programming Steps 
    If CO tine Attributes need to be initialized: 
    1. Press the CO Line Attributes flexible button 
    (Button #2). The following message will be 
    shown on the display phone: Description 
    The CO Line parameters may be initialized setting 
    all data fields to their original, default values. The 
    following data fields are returned to their default 
    value upon initializing the CO Line parameters; 
    2. To initialize the CO Line Attributes, press the 
    HOLD button. Confirmation tone will be heard. 
    DEFAULT VALUE 
    660-4 
    Issue 1, November 1991  
    						
    							sTARPLUS@ SPD 1428 & 2858 Digital Key Telephone Systems 
    Initialize Data Base Parameters (Cont’d) 
    D. Initialize Station Attributes 
    Programming Steps 
    If Station Attributes need to be initialized: 
    1. Press the Station Attributes flexible button (But- 
    ton #3). The following message will be shown 
    on the display phone: Description 
    The Station parameters may be initialized setting all 
    data fields to their original, default values. The fol- 
    lowing data fields are returned to their default value 
    upon initializing the Station parameters; 
    2. To initialize the Station Attributes, press the 
    HOLD button. Confirmation tone will be heard. 
    Off-Hook Preference 
    Issue 1, November 1991 660-5  
    						
    							Digital Key Telephone Systems sTARPLUS@ SPD 1428 & 2868 
    1 
    ZAMP ON 
    DND 
    CONF 
    HTP 
    7, r SPKRVOL 
    FUNGVOL 
    Figure 660-l Default Button Mapping 
    660-6 
    Issue 1, November 1991  
    						
    							Initialize Data Base Parameters (Cont’d) 
    E. Initialize Group Parameters 
    Programming Steps 
    If Group Parameters need to be initialized: 
    1. Press the Group Parameters flexible button 
    (Button #4). The following message will be 
    shown on the display phone: Description 
    Hunt, UCD and Voice Mail Group parameters may 
    be initialized setting all data fields to their original, 
    default values. The following data fields are returned 
    to their default value upon initializing Group parame- 
    ters: 
    2. To initialize the Group parameters, press the 
    HOLD button. Confirmation tone will be heard. 
    PROGRAMCODE FLEX 
    BUT-TON FEATURE DEFAULT VALUE 
    (after initializing) 
    FLASH 30 l-8 Hunt Groups 330337 
    No Hunt Groups established 
    9 Station or Pilot Hunting All Hunt Groups default using Pilot 
    Hunting 
    FLASH 60 1-8 UCD Groups 550-557 
    No UCD groups established 
    9 Alternate UCD Group Assign No UCD Alternates group 
    assignments is made 
    10 I Overflow Assignment 1 No Overflow assignment is made 
    11 1 UCD Station Assignments 
    No stations are assigned 
    12 Announcement Table Assign 
    No RAN tables are specified 
    1 UCD Ring Timer 
    060seconds 
    2 UCD Message Interval Timer 
    060 seconds 
    3 
    UCD Overflow Timer 060seconds 
    4 UCD Wrap-Up Timer 
    004seconds 
    5 UCD No Answer Timer 
    000 seconds (disabled) 
    1-2 RAN Tables 1 and 2 
    No RAN parameters set  FLASH 61 
    FLASH 62 
    FLASH 65 1-8 Voice Mail Groups 440447 No Voice Mail groups are 
    established 
    9 Alternate VM Group Assign No Alternate VM group assignmeni 
    is made 
    10 Leave Table No outpulsing table is 
    referenced 
    FLASH 66 11 Retrieve Table No outpulsing table is 
    referenced 
    12 VM Station Assignments 
    NO stations are assigned 
    l-7 Voice Mail Out-Pulsing Tables Out-pulse tables are empty 
    for in-band signaling by default 
    8 Voice Mail Disconnect Table Disconnect table is empty 
    FLASH 67 1 In-Band Digits for Incoming 
    CO Calls Disabled by default 
    I 
    Issue 1, November 1991 660-7  
    						
    							Initialize Data Base Parameters (Cont’d) 
    F. Initialize Toll Tables 
    Programming Steps 
    If Exception Tables need to be initialized: 
    1. Press the Toll Tables flexible button (Button 
    #5). The following message will be shown on 
    the display phone: Description 
    The Toll Table parameters including the Allow/Deny 
    Tables and the Special Tables may be initialized 
    setting all tables to their original, default values. The 
    following Tables are cleared returning to their default 
    value upon initializing the Exception Tables parame- 
    , 
    2. To initialize the Toll Tables, press the HOLD 
    button. Confirmation tone will be heard. 
    TABLE DEFAULT VALUE 
    (after initializing) 
    ALLOW TABLE - A Table Cleared (no entries 
    DENY TABLE - A Table Cleared (no entries) 
    ALLOW TABLE - B Table Cleared (no entries) 
    DENY TABLE - B Table Cleared (no entries) 
    SPECIAL TABLE Table Cleared (no entries allowed, no 
    1 area code specified) 
    SPECIAL TABLE Table Cleared (no entries allowed, no 
    2 area code specified) 
    SPECIAL TABLE Table Cleared (no entries allowed, no 
    3 area code specified) 
    SPECIAL TABLE 
    4 Table Cleared (no entries allowed) 
    666-6 Issue 1, November 1991  
    						
    							STARPLUS@ SPD 1428 & 2856 Digital Key Telephone Systems 
    Initialize Data Base Parameters (Cont’d) 
    G. Initialize System Speed 
    Programming Steps Description 
    If System Speed bins need to be initialized: 
    1. Press the System Speed flexible button (Button 
    #6). The following message will be shown on 
    the display phone: 
    2. To initialize the System Speed bins, press the 
    HOLD button. Confirmation tone will be heard. Numbers entered into the System Speed dial Table 
    may be initialized clearing all bins to their original, 
    default value (empty). All bins 20 through 99 are 
    cleared returning to their default value (empty) upon 
    initializing the Speed Dial Table. 
    Issue 1, November 1991 660-9  
    						