STARPLUS@ SPD 1428 & 2858 Digital Key Telephone Systems 320.22 320.23 320.24 320.25 330.1 SECTION 400 400.1 400.2 400.3 400.4 400.5 400.6 400.7 400.8 400.9 SECTION 500 500.1 500.2 500.3 500.4 500.5 500.6 FLEXIBLE BUT-l-ON PROGRAMMING .......................................................... 320-6 MEET ME PAGE ............................................................................................ 320-6 PAGING.. ........................................................................................................ 320-7 A. External Paging ............................................................................. 320-7 B. Internal Paging.. ............................................................................. 320-7 C. All Call Paging (Internal/External). ................................................. 320-7 RELEASE BUTTON ....................................................................................... 320-7 LCD DISPLAYS.. ........................................................................................... 330-I GENERAL DESCRIPTION .................................................................... 400-l SYSTEM TECHNOLOGY.. ............................................................................. 400-l SPD 1428 COMMON EQUIPMENT.. ............................................................. 400-2 A. Basic Key Service Unit with Power Supply (BKSU) ....................... 400-2 B. SPD 1428 Expansion KSU with Power Supply (EKSU) ................ 400-4 C. 2x4 CO/Station Expander Module ................................................. 400-6 D. 4x8 CO/Station Expander Module ................................................. 400-7 SPD 2856 SYSTEM COMPONENTS ............................................................. 400-8 A. Equipment Cabinet With Power Supply (KSU) .............................. 400-8 B. Central Processor Board (CPB) ..................................................... 400-8 C. 4 x 8 CO/Station Key Interface Board (CKB). .............................. 400-l 1 D. 4x8 CO/SLT Interface Board (CSB) (Future). .............................. 400-l 2 APPLICATION MODULES ........................................................................... 400-l 3 A. SPD 1428 Expansion I/O Module (IOM). ..................................... 400-13 B. SPD 2856 Expansion I/O Module (IOM). ..................................... 400-13 C. 1200 Baud Modem Module (MM) ................................................ 400-13 D. DTMF Receiver Module (RM) ...................................................... 400-l 3 SPD 1428 & SPD 2856 TERMINALS.. ......................................................... 400-14 A. 34 Button Digital Terminal (Enhanced) ........................................ 400-l 4 B. 34 Button Digital Display Terminal (Executive). ........................... 400-l 6 C. Digital DSS/DLS Console ............................................................ 400-17 SLT ADAPTER / OFF-PREMISE EXTENSION MODULE.. ......................... 400-18 RELAY / SENSOR INTERFACE MODULE.. ................................................ 400-18 POWER FAILURE TRANSFER UNIT (PFTU) ............................................. 400-18 SYSTEM SPECIFICATIONS AND CAPACITY ............................................ 400-19 INSTALLATION ........................................................................................ 500-l SITE PLANNING ............................................................................................ 500-l A. System Grounding ......................................................................... 500-l B. Lightning Protection ....................................................................... 500-I SPD 1428 INSTALLATION PLANNING ......................................................... 500-l SPD 1428 COMMON EQUIPMENT.. ............................................................. 500-2 A. Basic Key Service Unit with Power Supply (BKSU). ...................... 500-2 B. Expansion KSU with Power Supply (EKSU). ................................. 500-8 C. 2x4 CO/STA Expander Module ................................................... 500-l 0 D. 4x8 CO/STA Expander Module ................................................... 500-l 2 SPD 2856 INSTALLATION PLANNING ....................................................... 500-14 SPD 2856 SYSTEM COMPONENTS.. ......................................................... 500-14 A. Equipment Cabinet With Power Supply (KSU) ............................ 500-l 4 B. Cabinet Installation ...................................................................... 500-l 6 C. Central Processor Board (CPB) ................................................... 500-l 7 D. 4 x 8 CO/Station Key Interface Board (CKB):. ............................. 500-21 E. 4x8 CO/SLT Interface Board (CSB) (Future). .............................. 500-23 APPLICATION MODULE(S) INSTALLATION:. ............................................ 500-26 A. SPD 1428 Expansion I/O Module (IOM). ..................................... 500-26 Issue 1, November 1991 ix
, Digital Key Telephone Systems STARPLUS@ SPD 1428 & 2856 500.7 500.8 500.9 SECTION 600 600.1 600.2 600.3 600.4 600.5 600.6 600.7 SECTION 610 610.1 610.2 610.3 610.4 610.5 610.6 610.7 B. SPD 2856 Expansion I/O Module (IOM) ..................................... .500-26 C. 1200 Baud Modem Module (MM). ................................................ 500-26 D. Installing the DTMF Receiver Module (RM) ................................ .500-30 SPD 1428 & SPD 2856 TERMINALS .......................................................... .500-31 A. Digital Terminal Installation: ........................................................ .500-31 B. Digital DSS/DLS Installation ......................................................... 500-31 C. Wall Mounting the Telephone.. .................................................... .500-31 D. Single Line Telephone Installation: (future). ................................ .500&l E. SLT Adapter / Off-Premise Extension Module ............................ .500-34 POWER FAILURE TRANSFER ................................................................... .500-36 A. Relay / Sensor Interface Module ................................................. .500-36 B. Stat-plus Power Failure Transfer Unit (PFTU) .............................. 500-36 INSTALLING RECORDED ANNOUNCEMENT DEVICE (RAN). ................ .500-40 CUSTOMER DATA BASE PROGRAMMING .................................. 600-l INTRODUCTION ............................................................................................ .600-l PROGRAM MODE ENTRY (Key Station). ..................................................... .600-l PROGRAM MODE ENTRY (Data Terminal or PC) ....................................... .600-8 BEGINNING TO PROGRAM ......................................................................... .600-8 INITIALIZATION ............................................................................................. .600-8 CUSTOMER DATA WORKSHEETS ............................................................. -600-8 DATA BASE FIELDS ..................................................................................... .600-8 SYSTEM PARAMETERS PROGRAMMING .................................... 61 O-l SYSTEM TIMERS .......................................................................................... .61 O-l A. System Hold Recall Timer ............................................................. -61 O-2 B. Exclusive Hold Recall Timer .......................................................... .61 O-2 C. Attendant Recall Timer ................................................................... 610-3 D. Transfer Recall Timer .................................................................... .61 O-3 E. Preset Forward Timer .................................................................... 610-4 F. Call Forward No/Answer Timer ..................................................... .61 O-4 G. Pause Timer .................................................................................. .610-5 H. Call Park Recall Timer ................................................................... .61 O-5 I. Conference/DISA Timer ................................................................ .610-6 J. Paging Timeout Timer.. ................................................................. .61 O-6 K. CO Ring Detect Timer ................................................................... .610-7 L. SLT DTMF Receiver Timer ........................................................... .61 O-7 M. Message Wait Reminder Tone.. .................................................... .610-8 N. SLT Hook Flash Timer .................................................................. .61 O-8 0. SLT Hook Flash Debounce Timer ................................................. .61 O-9 SYSTEM FEATURES PROGRAMMING ..................................................... .610-10 A. Attendant Override ...................................................................... .610-l 1 B. Hold Preference .......................................................................... .610-l 1 C. External Night Ring ..................................................................... .610-12 D. Exec Override Warning Tone.. .................................................... .61 O-12 E. Page Warning Tone .................. i.. ............................................... .610-13 F. Music Channel ............................................................................. 61 O-13 G. LCR Enable ................................................................................. .610-14 H. Account Codes - Forced ............................................................. .61 O-14 ATTENDANT STATION ASSIGNMENT ...................................................... .61 O-15 SEl-fING SYSTEM TIME AND DATE ...................................... I................... 610-15 PBX DIALING CODES ................................................................................. .610-16 EXECUTIVE/SECRETARY PAIRS .............................................................. .610-16 RELAY/SENSOR PROGRAMMING ............................................................ ;610-17 X Issue 1, November 1991
sTARPLUS@ SPD 1428 & 2856 Digital Key Telephone Systems 610.8 610.9 610.10 610.11 610.12 SECTION 620 620.1 620.2 SECTION 630 630.1 A. Programming relay for External Paging: ...................................... 61 O-1 8 B. Programming relay for RAN Starting: .................................... h.. .. 61 O-1 8 C. Programming relay for Power Failure Transfer:. .......................... 61 O-1 8 D. Programming relay for Loud Bell Control:. ................................... 61 O-1 9 E. Programming relay for CO Line Control: ..................................... 61 O-1 9 F. Assign Relay/Sensor Interface Module to a station: .................... 61 O-20 G. Program sensing ciruit as a RAN Sensing (RAN END) circuit: .... 610-20 BAUD RATE ASSIGNMENTS.. .................................................................... 610-21 ACCESS CODES ......................................................................................... 61 O-22 A. DISA Access Code ...................................................................... 61 O-22 B. Set Data Base Admin. Password.. ............................................... 610-22 STATION MESSAGE DETAIL RECORDING (SMDR). ................................ 610-23 A. SMDR Enable/Disable.. ............................................................... 61 O-23 B. Long Distance/Local Assignment ................................................ 61 O-23 C. Character Print Assignment.. ....................................................... 61 O-24 D. Baud Rate Display.. ..................................................................... 610-24 E. SMDR Port Assignment.. ............................................................. 61 O-24 WEEKLY NIGHT MODE SCHEDULE.. ........................................................ 610-25 A. Automatic/Manual Operation ....................................................... 61 O-25 B. Day of Week programming .......................................................... 61 O-25 HUNT GROUPS ........................................................................................... 61 O-26 A. Hunt Group Programming.. .......................................................... 610-26 B. Station/Pilot Hunting Assignment ................................................ 61 O-26 CO LINE ATTRIBUTES PROGRAMMING ...................................... 620-l INTRODUCTION ............................................................................................ 620-l A. DTMWDial Pulse Programming.. ................................................... 620-2 B. CO/PBX Programming.. ................................................................. 620-2 C. UNA Programming.. ....................................................................... 620-2 D. DISA Trunk-to-Trunk (Per CO Line) .............................................. 620-3 E. Privacy ........................................................................................... 620-4 F. Loop Supervision Programming .................................................... 620-5 G. DISA Programming.. ...................................................................... 620-5 H. Flash Timer Programming ............................................................. 620-6 I. Line Group Programming .............................................................. 620-6 J. Class of Service (COS) Programming.. ......................................... 620-7 K. CO Line Ringing Assignment.. ....................................................... 620-8 DIAL PULSE PARAMETERS.. ....................................................................... 620-9 STATION AlTRIBUTES PROGRAMMING ..................................... 630-l INTRODUCTION ............................................................................................ 630-l A. Paging Access.. ............................................................................. 630-2 B. Do Not Disturb ............................................................................... 630-3 C. Conference Enable/Disable (Per Station). ..................................... 630-3 D. Executive Override ........................................................................ 630-4 E. Privacy (Per Station). ..................................................................... 630-5 F. Speed Dialing Access.. .................................................................. 630-6 G. Line Queuing ................................................................................. 630-6 H. Preferred Line Answer.. ................................................................. 630-7 I. Off-Hook Voice Over (Future). ....................................................... 630-7 J. Call Forwarding ............................................. . ................................ 630-8 K. Forced Least Cost Routing ............................................................ 630-8 L. Station Identification .................................................................... 630-10 M. Station Class of Service (COS) ...................................... I.. .......... 630-12 Issue 1, November 1991 xi
SECTION 640 UNIFORM CALL DISTRIBUTION (UCD) . . . . . . . . . . . . . . . . ..-................-...... 640-l N. Speakerphone Programming ....................................................... 630-13 0. Pick-Up Group(s) Programming.. ................................................. 630-13 P. Paging Zone(s) Programming ..................................................... .630-l 4 cl. Preset Call Forward Programming.. ............................................ .630-l 5 R. CO Line Group Access ............................................................... .630-16 S. LCR Class of Service.. ................................................................ .630-l 6 T. Off-Hook Preference Programming.. ............................................ 630-17 U. Flexible Button Programming ...................................................... .630-l 8 v. Display Flexible Buttons .............................................................. .630-20 640.1 640.2 640.3 UCD GROUP PROGRAMMING .................................................................... .640-l A. Alternate UCD Group Assignment ................................................ .640-l B. Overflow Station Assignment ........................................................ .640-2 C. UCD Station Assignment(s) .......................................................... .640-2 D. Recorded Announcement Assignment(s) ..................................... .640-2 UCD TIMERS ................................................................................................. .640-3 A. UCD Ring Timer ............................................................................ .640-3 B. UCD Message Interval Timer.. ...................................................... .640-4 C. UCD Overflow Timer ..................................................................... -640-4 D. UCD Auto Wrap-Up Timer ............................................................ .640-4 E. UCD No-Answer Timer ................................................................. .640-5 UCD RAN ANNOUNCEMENT TABLES ........................................................ .640-6 SECTION 645 VOICE MAIL GROUPS (VM) . . . . . . . . . . . . ..~............................*..............-.*... 645-1 645.1 645.2 645.3 SECTION 650 VOICE MAIL PROGRAMMING ...................................................................... .645-l A. Alternate Voice Mail Group ........................................................... .645-2 B. “Leave” Mail Index Entry ................................................................ 645-2 C. “Retrieve” Mail Index Entry ............................................................ .645-2 D. Station Assignment(s) ................................................................... -645-3 VOICE MAIL OUTPULSING TABLE .............................................................. .645-4 A. Voice Mail In-Band Signaling* ........................................................ .645-4 B. Voice Mail Disconnect Table:. ....................................................... .645-5 VOICE MAIL IN-BAND DIGITS ...................................................................... .645-6 EXCEPTION TABLES PROGRAMMING .......................................... 650-l 650.1 650.2 650.3 INTRODUCTION ........................................................................................... ..650- 1 RELATED ITEMS TO TOLL RESTRICTION ................................................. .650-2 A. CO/PBX Lines ............................................................................... .650-2 B. Forced Account Codes .................................................................. .650-2 C. SLT DTMF Receivers .................................................................... .650-2 D. LCR VS. Toll Restriction ............................................................... .650-2 TOLL RESTRICTION PROGRAMMING ........................................................ -650-4 A. Entering Toll Table Programming.. ................................................ .650-4 B. Allow Table Programming ............................................................. .650-5 C. Deny Table Programming ............................................................. .650-7 D. Special Table Programming.. ........................................................ .650-8 E. Displaying Toll Table Entries.. ....................................................... .650-g SECTION 655 LEAST COST ROUTING PROGRAMMING .0...............~......~.~......... 655-l A. B. C. D. Introduction .............................................................. :. ................... -655-l LCR Operation .............................................................................. .655-l LCR Programming ........................................................................ .655-3 3-Digit Area/Off ice Code Table ....................................................... 655-4 xii Issue 1, November 1991
STARPLUS@ SPD 1428 & 2856 Digital Key Telephone Systems SECTION 660 SECTION 665 PRINTING SYSTEM DATA BASE PARAMETERS . . . . . . . . . . . . . . . . . ..s.. 665-l SECTION 700 700.1 700.2 700.3 SECTION 800 800.1 800.2 800.3 E. F. G. H. I. J. K. L. 6-Digit Office Code Table .............................................................. 655-5 Exception Code Table -. ............................................................ ...... 655-6 Route List Table.. ........................................................................... 655-7 Insert/Delete Table ........................................................................ 655-8 Daily Start Time Table ................................................................... 655-9 Weekly Schedule Table.. ............................................................. 655-l 0 LCR Routing for Toll Information ................................................. 655-l 1 Default LCR Data Base ............................................................... 655-l 2 INITIALIZE DATA BASE PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 660-l A. B. C. D. E. F. G. H. I. J. Introduction.. .................................................................................. 660-i Initialize System Parameters ......................................................... 660-2 Initialize CO Line Attributes ........................................................... 660-4 Initialize Station Attributes ............................................................. 660-5 Initialize Group Parameters ........................................................... 660-7 Initialize Toil Tables ....................................................................... 660-8 Initialize System Speed ................................................................. 660-9 Initialize LCR Tables.. .................................................................. 660-I 0 Initialize Entire System and Reset (all parameters). .................... 660-l 1 Initialize ICLID Table.. .................................................................. 660-l 2 A. Introduction.. .................................................................................. 665-l B. Printing System Parameters.. ........................................................ 665-2 C. Printing CO Line Attributes ............................................................ 665-4 D. Printing Station Attributes .............................................................. 665-6 E. Printing Group Parameters.. .......................................................... 665-8 F. Printing Toll Tables ...................................................................... 665-l 0 G. ‘Printing System Speed Bins ........................................................ 665-i 2 H. Printing LCR Tables.. ................................................................... 665-l 4 I. Printing Entire System Data Base ............................................... 665-24 SYSTEM CHECKOUT ............................................................................ 700-l INTRODUCTION ............................................................................................ 700-l PRELIMINARY PROCEDURES.. ................................................................... 700-l POWER UP SEQUENCE.. ............................................................................. 700-l MAINTENANCE AND TROUBLESHOOTING ................................ 800-l PRINTED CIRCUIT BOARD (PCB) TROUBLESHOOTING CHARTS .......... 800-l REMOTE MAINTENANCE.. ........................................................................... 800-4 A. General Overview .......................................................................... 800-4 B. Overview of Maintenance Commands.. ......................................... 800-4 C. Maintenance Password ................................................................. 800-4 D. Exit Maintenance ........................................................................... 800-4 E. System Configuration .................................................................... 800-5 F. CO/Station Configuration ............................................................... 800-6 G. Event Trace Buffer.. ....................................................................... 800-7 REMOTE SYSTEM MONITOR ...................................................................... 800-8 A. General Overview.. ........................................................................ 800-8 B. Monitor Password .......................................................................... 800-8 C. Help Menu (?) ............................................... .‘................................ 800-8 D. Dump Memory Data.. ..................................................................... 800-8 E. Event Trace Mode ......................................................................... 800-9 F. Modify Memory command ............................................... . ........... 800-l 0 Issue 1, November 1991 .-. XIII
Digital Key Telephone Systems STARPLUS@ SPD 1428 & 2856 G. H. Baud Rate Command ................................................................. ..800-10 Exit the Monitor mode .................................................................. 800-l 0 APPENDIX A CUSTOMER DATABASE PROGRAMMING . . . . . . . ..s.........D.m.m..n.m.q..s..m. A-l APPENDIX B DIGITAL SYSTEMS PART NUMBERS .*..................m........................... B-l APPENDIX C ICLID GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..-..........*...~.....~.~.~~ C-l c.1 c.2 c.3 c.4 C.5 C.6 c.7 C.8 introduction ........................................................................................................ C-l System Configuration ......................................................................................... C-l Functional Performance ..................................................................................... C-l C.3.1 Calling Number/Name Display.. ........................................................ C-2 C.3.2 Incoming Number/Name SMDR.. ...................................................... C-2 C.3.3 Unanswered Call Management.. ....................................................... C-2 C.3.4 Local Name Translation .................................................................... c-3 C.3.5 ICLID Display Phone Operation ........................................................ C-3 Implementation Plan .......................................................................................... c-4 C.4.1 ICLID KTU Display Phone.. ............................................................... C-4 C.4.2 Table Structures ................................................................................ c-5 C.4.3 Logic Operation ................................................................................. C-6 C.4.4 ICLID Input Device Data Format.. ..................................................... C-6 Potential Additional Features for Later Implementation ..................................... C-7 Direction of Specific Numbers to Special Handling (Favored Customer Treatment).C-7 Features Implemented External to the KSU Software ....................................... C-7 ICLID Programming ........................................................................................... C-8 C.8.1 Local Name Translation .................................................................... C-8 C.8.2 ICLID Features ................................................................................ C-l 0 xiv Issue 1, November 1991
STARPLUS@ SPD 1428 & 2856 Digital Key Telephone Systems LIST OF FIGURES SECTION 100 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100-l SECTION 200 KEY STATION FEATURE DESCRIPTIONS .............................. 200-l Figure 200-l Default Button Mapping ......................................................................................... 200-l 1 SECTION 210 SINGLE LINE TELEPHONE FEATURE DESCRlPTlON...........210- 1 SECTION 220 All-ENDANT FEATURE DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220-l SECTION 300 STATION FEATURE OPERATION ............................................ 300-l Figure 300-l 34 Button Digital Display Terminal.. .......................................................................... 300-2 SECTION 310 SLT FEATURE OPERATION ..................................................... 310-l SECTION 320 ATTENDANT FEATURE OPERATION ...................................... 320-l Figure 320-l 34 Button Attendant Digital Terminal.. ...................................................................... 320-2 SECTION 400 GENERAL DESCRIPTION ......................................................... 400-l Figure 400-l Starplus Basic KSU & Main Key Service Board ....................................................... 400-3 Figure 400-2 Starplus Expansion KSU (EKSU) ............................................................................ 400-5 Figure 400-3 2x4 Expander Module.. ............................................................................................. 400-6 Figure 400-4 4x8 Expander Module.. ............................................................................................. 400-7 Figure 400-5 Starplus SPD 2856 Equipment Cabinet (KSU). ........................................................ 400-9 Figure 400-6 Central Processing Board (CPB) ............................................................................ 400-l 0 Figure 400-7 4x8 CO/Station Interface Board (CKB) ................................................................... 400-l 1 Figure 400-8 4x8 CO/SLT Interface Board (CSB) ....................................................................... 400-l 2 Figure 400-9 Digital 34 Button Terminal ...................................................................................... 400-l 5 SECTION 500 INSTALLATION .......................................................................... 500-l Figure 500-i SPD 1428 Mounting Arrangements.. ........................................................................ 500-3 Figure 500-2 SPD 1428 Mounting Dimensions.. ............................................................................ 500-4 Figure 500-3 SPD 1428 RS-232C Connections ............................................................................ 500-6 Figure 500-4 Expansion KSU & Main Key Service Bd (EKSU) ..................................................... 500-9 Figure 500-5 SPD 2856 Basic Cabinet with Power Supply ......................................................... 500-15 Figure 500-6 SPD 2856 Mounting Dimensions ............................................................................ 500-l 6 Figure 500-7 Central Processor Board (CPB) ............................................................................. 500-l 8 Figure 500-8 SPD 2856 CPB RS-232C Connections.. ................................................................ 500-I 9 Figure 500-9 SPD 2856 Shielded Cable Terminations ................................................................ 500-20 Figure 500-l 0 CO/STA Interface Board (CKB) ............................................................................ 500-22 Figure 500-l 1 CO/SLT Interface Board (CSB) ............................................................................ 500-24 Figure 500-12 SPD 1428 Basic KSU Plug-in Card Locations.. .................................................... 500-27 Figure 500-l 3 SPD 1428 Expansion I/O Module Pin-outs.. ......................................................... 500-28 Figure 500-l 4 SPD 2856 Expansion I/O Module Pin-outs.. ......................................................... 500-29 Figure 500-l 5 Station Modular Block Wiring.. .............................................................................. 500-32 Figure 500-16 Wall Mounting the Starplus Digital Terminal.. ....................................................... 500-33 Figure 500-l 7 Off-Premise Extension (OPX) Module.. ................................................................ 500-35 Figure 500-l 8 Relay / Sensor Interface Module .......................................................................... 500-37 Figure 500-i 9 Power Failure Transfer Wiring Options.. ............................... .I .............................. 500-39 Figure 500-20 CO and SLT RAN Connections.. .......................................................................... 500-41 Issue 1, November 1991 xv
Digital Key Telephone Systems STARPLUS@ SPD 1428 & 2856 SECTION 600 CUSTOMER DATA BASE PROGRAMMING . ..m.......m.m*D....m.m.m..m 606-l Figure 600-l Data Terminal Program Codes Cross Reference .................................................... .600-2 Figure 600-2 Starplus SPD Programming Button Mapping ........................................................... .600-3 SECTION 610 SYSTEM PARAMETERS PROGRAMMING ............................. 610-l Figure 61 O-1 Hook Switch Activity ................................................................................................. .610-g Figure 61 O-2 Example of System Parameters Pgmng Form.. ..................................................... .61 O-l 0 SECTION 620 CO LINE ATTRIBUTES PROGRAMMING ................................ 620-l SECTION 630 STATION AlTRIBUTES PROGRAMMING . . . . . . . . . . . . . . . . . . . ..m......... 630-l SECTION 640 UNIFORM CALL DISTRIBUTION (UCD) D...........m*n.....m*..e..,.a.... 646-l 4 SECTION 645 VOICE MAIL GROUPS (VM) . . . . ..~.......................................~...... 645-l SECTION 650 EXCEPTION TABLES PROGRAMMING . . . . . . . . . . . . ..rn...B........‘...... 650-l SECTION 655 LEAST COST ROUTING PROGRAMMING .............................. 655-l Figure 655-l Ex: 3-Digit Area/Office Code Table Pgm Form ........................................................ .655-4 Figure 655-2 Ex: 6-Digit Office Code Table Pgm Form ................................................................. .655-5 Figure 655-3 Ex: Exception Code Table Pgm Form ...................................................................... .655-6 Figure 655-4 Ex: Insert/Delete Pgm Form ..................................................................................... .655-8 Figure 655-5 Ex: LCR Toll Information Routing Pgm Form.. ....................................................... .655-l 1 SECTION 660 INITIALIZE DATA BASE PARAMETERS ................................. 660-l Figure 660-l Default Button Mapping ............................................................................................ .660-6 SECTION 665 PRINTING SYSTEM DATA BASE PARAMETERS .................. 665-l Figure 665-i DB Printout of System Parameters .......................................................................... .665-3 Figure 665-2 DB Printout of CO Line Attributes ............................................................................ .665-5 Figure 665-3 DB Printout of Station Attributes .............................................................................. .665-7 Figure 665-4 DB Printout of Group Parameters ............................................................................ .665-g Figure 665-5 DB Printout of Exception Tables ............................................................................ .665-l 1 Figure 665-6 DB Printout of System Speed Numbers ................................................................. .665-l 3 Figure 665-7 DB Printout of LCR Default ..................................................................................... 665-l 5 SECTION 700 SYSTEM CHECKOUT ................................................................ 700-l SECTION 800 MAINTENANCE AND TROUBLESHOOTING ........................... 800-l Figure 800-l Remote Maintenance Help Menu ............................................................................. .800-4 Figure 800-2 System Configuration w/LCR ................................................................................... .800-5 Figure 800-3 CO/Station Configuration .......................................................................................... 800-6 Figure 800-4 Event Trace as it appears on Display .................................................................... .800-l 0 APPENDIX A CUSTOMER DATABASE PROGRAMMING ................................ A-l APPENDIX B DIGITAL SYSTEMS PART NUMBERS . . . . . . . . . . . . . . . . . . . . ..mm......e......m.. B-l APPENDIX C ICLID GENERAL DESCRIPTION ................................................. C-l Figure C-l ICLID System Configuration ............................................................................................ c-i xvi Issue 1, November 1991
LIST OF TABLES SECTION 100 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..~.. 100-l SECTION 200 KEY STATION FEATURE DESCRIPTIONS ..,........................... 200-l Table 200-l Alphabetical Feature Index ........................................................................................ 200-2 SECTION 210 SINGLE LINE TELEPHONE FEATURE DESCRlPTlON...........21o- I Table 21 O-l SLT Alphabetical Feature Index.. ............................................................................... 21 O-2 SECTION 220 ATTENDANT FEATURE DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220-l Table 220-l Attendant(s) Alphabetical Feature Index.. .................................................................. 220-2 SECTION 300 STATION FEATURE OPERATION ............................................ 300-l Table 300-l Star-plus Digital Terminal Numbering Plan.. ............................................................... 300-3 Table 300-2 Flex Button Programming Codes.. ........................................................................... 300-10 SECTION 310 SLT FEATURE OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..~~......... 310-l Table 310-l Starplus Digital SLT Numbering Plan ........................................................................ 31 O-2 SECTION 320 A-ITENDANT FEATURE OPERATION ...................................... 320-l Table 320-l Starplus Digital Attendant Numbering Plan.. .............................................................. 320-3 Table 330-l Liquid Crystal Displays (LCD). ................................................................................... 330-l SECTION 400 GENERAL DESCRIPTION ......................................................... 400-l Table 400-l . SPD 1428 and SPD 2856 System Capacities.. ..................................................... 400-20 Table 400-2 . Electrical Specifications.. ....................................................................................... 400-22 Table 400-3 . Environmental Specifications.. ............................................................................... 400-22 Table 400-4 - Loop Limits ............................................................................................................ 400-23 Table 400-5 Dialing Specifications .............................................................................................. 400-23 Table 400-6 . FCC Registration Numbers for SPD 1428.. ........................................................... 400-23 Table 400-7 . FCC Registration Numbers for SPD 2856.. ........................................................... 400-23 Table 400-8 . Dimensions and Weight ......................................................................................... 400-24 Table 400-9 . Miscellaneous Specifications.. ............................................................................... 400-24 Table 400-l 0 . Digital Terminal Audible Signals .......................................................................... 400-25 Table 400-l 1 . Single Line Telephone Audible Signals ............................................................... 400-25 Table 400-12 . OPX Telephone Audible Signals ......................................................................... 400-26 Table 400-l 3 . DSS/BLF Button Visual Indicators.. ..................................................................... 400-27 Table 400-14 . CO Line Button Visual Indicators.. ....................................................................... 400-27 Table 400-l 5 . Function Button Visual Indicators ........................................................................ 400-27 SECTION 500 INSTALLATION .......................................................................... 500-l Table 500-l SPD 1428 Basic KSU Jl 1 Station Connections ....................................................... 500-7 Table 500-2 SPD 1428 EKSU Jl 1 Station Connections.. ........................................................... 500-l 1 Table 500-3 SPD 1428 4x8 Expander Module Connection ........................................................ 500-l 1 Table 500-4 4x8 CO/Station Interface Board (CKB) .................................................................... 500-25 Table 500-5 4x8 CO/SLT Interface Board (CSB). ........................................................................ 500-25 Table 500-6 PFTU Conn A Connecting Block ............................................................................. 500-38 Table 500-7 PFTU Conn A Connecting Block .............................................. . .............................. 500-38 Table 500-8 SMDR Printout ......................................................................................................... 500-42 SECTION 600 CUSTOMER DATA BASE PROGRAMMING ............................ 600-l Table 600-l Default Values ........................................................................................... ..~...............600- 4 lssuel,November1991 xvii
Digital Key Telephone Systems STARPLUS@ SPD 1428 & 2856 SECTION 610 SYSTEM PARAMETERS PROGRAMMING ..m.....m..........*...mmmm.. 610-l SECTION 620 CO LINE AlTRIBUTES PROGRAMMING ................................ 628-l Table 620-l Class of Service (COS) ............................................................................................. .620-7 SECTION 630 STATION ATTRIBUTES PROGRAMMING ............................... 638-l Table 630-l Class of Service (COS) ........................................................................................... .630-12 Table 630-2 Flexible Button Display Designations ...................................................................... .630-20 SECTION 640 UNIFORM CALL DISTRIBUTION (UCD) .................................. 640-l SECTION 645 VOICE MAIL GROUPS (VM) ..................................................... 645-l , SECTION 650 EXCEPTION TABLES PROGRAMMING .................................. 650-l Table 650-l Class of Service (COS) .............................................................................................. 650-l Table 650-2 Allow/Deny Toll Table ................................................................................................ .650-2 SECTION 655 LEAST COST ROUTING PROGRAMMING .............................. 655-l Table 655-l LCR Class of Service Table ...................................................................................... .655-7 Table 655-2 Daily Start Time & Weekly Schedule Tables ............................................................. .655-g Table 655-3 Ex: Daily & Weekly Start Time Tables ..................................................................... .655-10 SECTION 660 INITIALIZE DATA BASE PARAMETERS ................................. 660-l SECTION 665 PRINTING SYSTEM DATA BASE PARAMETERS ..m . . ..s.......... 665-1 SECTION 700 SYSTEM CHECKOUT . . ..~............~.....................~.............~.....~.... 700-l SECTION 800 MAINTENANCE AND TROUBLESHOOTING ........................... 800-l Table 800-l SPD 1428 Basic KSU ............................................................................................... .800-l Table 800-2 SPD 1428 EPROM Memory Size .............................................................................. .800-l Table 800-3 SPD 1428 Static RAM Memory Size ......................................................................... .800-l Table 800-4 SPD 2856 Central Processing Board (CPB) ............................................................. .800-2 Table 800-5 SPD 2856 CPB Static RAM Memory Size ................................................................ .800-2 Table 800-6 SPD 2856 CPB EPROM Memory Size ..................................................................... .800-2 Table 800-7 4x8 CO/Station Interface Board (CKB). ..................................................................... .800-3 Table 800-8 4x8 CO/SLT Interface Board (CSB) .......................................................................... .800-3 Table 800-9 DTMF Receiver Module (RM) ................................................................................... .800-3 Table 800-10 I/O Module (IOM) ..................................................................................................... .800-3 Table 800-l 1 Single Line Telephone Adapter (OPX) .................................................................... .800-3 APPENDIX A CUSTOMER DATABASE PROGRAMMING ................................ A-l Appendix A-l System Parameters ..................................................................................................... A-l Appendix A-2 UCD and Hunt Group Parameters ............................................................................... A-3 Appendix A-3 Voice Mail Group Parameters ...................................................................................... A-4 Appendix A-4 CO tine Programming (Flash 40) ................................................................................ A-5 Appendix A-5 CO Line Ringing Assignment Chart ............................................................................ A-7 Appendix A-6 Station Programming (Flash 50) .................................................................................. A-8 Appendix A-7 Button Assignment Chart (Flash 50) ............................................................................ A-9 Appendix A-8 System Speed Dial Numbers ..................................................................................... A-10 Appendix A-9 Exception Tables (Flash 70) ...................................................................................... A-12 Appendix A-l 0 Least Cost Routing (Flash 75) ................................................................................. A-14 Appendix A-l 1 Route List Table ................................................................................................. .;. ... A-15 . . . XVIII Issue 1, November 1991