NEC Xen Ipk Features And Specifications Manual
Have a look at the manual NEC Xen Ipk Features And Specifications Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Xen IPK Features and Specifications Manual Features and Specifications Manual S15 – 543 Doc. No. 8201 - Release 1.0 July 2003 ¶+ASSMDR Incoming/Outgoing Print Selection 1-5-26 ¶+ASSMDR Valid Call Time Assignment 1-5-25 ¶+ASSMDR Print Format 1-5-02 ¶+CSSCOM Port Baud Rate Setting Assignment 1-8-35 ¶+BMStart Time Selection 1-1-05 ¶+ASSMDR Telephone Print Selection 4-56 4When the system is at default this Memory Block must be programmed for the feature to be used. Order and Shortcut System Data NameMemory BlockFunction 1-8-07 Attendant Page-Line Key1-8-08 Station Page-Line Key
July 2003 NEC Business Solutions Ltd 544 – S15 Station Message Detail Recording (SMDR) Doc. No. 8201 - Release 1.0 July 2003 THIS PAGE INTENTIONALLY LEFT BLANK
Features and Specifications Manual S16 – 545 Doc. No. 8201 - Release 1.0 July 2003 Station Name/Number DisplayS-16 FEATURE DESCRIPTIONThis feature allows a Multiline Telephone to display on its LCD its name and/or station number. These are displayed while the telephone is idle. SYSTEM AVAILABILITYTerminal Type All Multiline Terminals with an LCD. Required Components None. OPERATING PROCEDURESData Assignment Use Memory Block 4-61 (Extension Name/Number Display Selection) to specify the type of information to be displayed on an idle multiline telephones LCD, zNone, zNumber only, zName only, or zName and Number. Use Memory Block 4-10 (Station Number Assignment) to specify a stations extension number. This may be 2, 3 or 4 digits long. Use Memory Block 4-18 (Station Name Assignment) to specify a stations name. This may be up to 6 characters long. General An idle multiline telephones LCD displays information in the following priority order. 1. LCR and related trouble 2. Printer trouble 3. System data registration in progress 4. Absent message 5. Call Back indication 6. Station number/name display in idle state
July 2003 NEC Business Solutions Ltd 546 – S16Station Name/Number Display Doc. No. 8201 - Release 1.0 July 2003 The station number and/or name is positioned to the left side of the LCD. When both number and name are to be displayed, space(s) are provided between the number and name. Examples of these are indicated below: RELATED FEATURES LIST Number only: 100 Name only: NAME Number and Name: 2 digit Station No.:10 NAME 3 digit Station No.:100 NAME 4 digit Station No.:1000 NAME Feature NumberFeature Name A-6 Alphanumeric Display
Features and Specifications Manual S17 – 547 Doc. No. 8201 - Release 1.0 July 2003 Station Outgoing LockoutS-17 FEATURE DESCRIPTIONThis feature allows a station user to temporarily restrict outgoing calls by assigning a personal code (password). SYSTEM AVAILABILITYTerminal Type All terminals. Required Components None. OPERATING PROCEDURES 1. Go off-hook; receive internal dial tone. 2. Dial Password set Access Code. (Not set at default.) 3. Dial the Password Code 0000000000 (set as default). 4. Receive confirmation tone, and hang up. 1. Go off-hook; receive internal dial tone. 2. Dial Password cancel Access Code. (Not set at default). 3. Dial the Password Code 0000000000 (set as default). 4. Receive confirmation tone, and hang up. 1. Go off-hook; receive internal dial tone. 2. Dial Password cancel Access Code from another station. (Not set at default). 3. Dial the station number. 4. Receive confirmation tone, and hang up. To set: To cancel: To cancel Telephone Password and Default Password from the Attendant Position:
July 2003 NEC Business Solutions Ltd 548 – S17Station Outgoing Lockout Doc. No. 8201 - Release 1.0 July 2003 1. Go off-hook; receive internal dial tone. 2. Dial Password change Access Code. (Not set at default). 3. Dial current Password Code. 4. Enter new Password Code. 5. Hang up. SERVICE CONDITIONSData Assignment Telephone Password can be allowed or disallowed by Station Class of Service. The ability to cancel Telephone Password and default a station password is allowed or disallowed by Attendant Class of Service. At default, when a station user sets Telephone Password, the station is outgoing restricted. This can be changed (system-wide) to a different Code Restriction Class of Service in System Programming. General Internal calls, Paging, and Feature Access are still provided when a telephone is locked out. The Password can be a maximum of 10 digits. Password Set/Cancel and Password Change do not have an Access Code at default. Service tone is not provided when setting a new password that is less than 10 digits. There is no terminal indication when Station Outgoing Lockout is set. RELATED FEATURES LIST To change the Password Code Feature NumberFeature Name C-19 Code Restriction
Xen IPK Features and Specifications Manual Features and Specifications Manual S17 – 549 Doc. No. 8201 - Release 1.0 July 2003 GUIDE TO FEATURE PROGRAMMING Order and Shortcut System Data NameMemory BlockFunction 1-8-07 Attendant Page-Line Key1-8-08 Station Page-Line Key ¶+BTSClass of Service (Attendant) Feature Selection 1 1-8-07 2-4 ¶+BTSClass of Service (Station) Feature Selection 2 1-8-08 2-3 ¶+BTTStation to Class of Service Feature Assignment 4-17 ¶+BA4Access Code (1-, 2-, or 3-Digit) Assignment1-1-46/47/ 48035 ~ 038 ¶+ACCode Restriction Class Assignment when Lockout is Set1-1-70 4When the system is at default this Memory Block must be programmed for the feature to be used.
July 2003 NEC Business Solutions Ltd 550 – S17Station Outgoing Lockout Doc. No. 8201 - Release 1.0 July 2003 THIS PAGE INTENTIONALLY LEFT BLANK
Features and Specifications Manual S18 – 551 Doc. No. 8201 - Release 1.0 July 2003 Station RelocationS-18 FEATURE DESCRIPTIONThe Station Relocation feature enables a station to be moved from one location to another without reprogramming the station data. The station set of features and extension numbers is the same after it has been moved to the new location. SYSTEM AVAILABILITYTerminal Type All terminals. Required Components None. OPERATING PROCEDURES 1. Press T. 2. Dial Access Code HD. 1. Press P. 2. Dial the Terminal Exchange Access Code _______ (not assigned at default). 3. Dial the extension number of the distant Multiline Terminal (i.e., the new Multiline Terminal). 4. Enter the telephone password of the distant Multiline Terminal (same password set for Station Lockout). 5. Press P. The Multiline Terminal is relocated. SERVICE CONDITIONSData Assignment Any Attendant can turn the feature ON and OFF, if allowed in Attendant Class of Service. To set and cancel the Terminal Exchange Mode (Attendant) To exchange two terminals
July 2003 NEC Business Solutions Ltd 552 – S18Station Relocation Doc. No. 8201 - Release 1.0 July 2003 Restrictions This feature can be used to relocate terminals among the following combinations: This feature cannot be used with the following combinations: An error tone is received and Error is displayed in the LCD under the following conditions: zEntering a station number that causes a prohibited combination (refer to the previous bullet for combinations). zEntering a station number that does not exist. zEntering the station number of the terminal being used to perform Station Relocation. zEntering a Pilot Number or CAR number. zEntering the wrong password. zEntering a station number of the terminal to be exchanged and that station is not idle. zStation Relocation Mode is not set. General The station password must be set from an individual station. The station password is the same as the password set for Station Lockout. If Feature + 84 is programmed on a One-Touch key or Feature Access key, the LED lights when this feature is turned ON and remains lit until the feature is turned OFF. Feature + 84 is used to toggle this feature ON and OFF. When this feature is set/reset using Feature + 84, the setting is retained even if a second power on is performed. The BLF indication on the One-Touch or Feature Access keys returns when the system becomes operable. If multiple Attendants have Feature + 84 stored on a One-Touch or Feature Access key, they have the same BLF indications on the key where Feature + 84 is stored. When this feature is set/reset using Feature + 84, RELO Mode ON or RELO Mode OFF is displayed for five seconds. Multiline ............................................. Multiline Single Line Telephone ...................... Single Line Telephone Single Line Telephone Adapter ....... Single Line Telephone Adapter Multiline ............................................. Single Line Telephone Multiline ............................................. Single Line Telephone Adapter Single Line Telephone...................... Single Line Telephone Adapter