    Have a look at the manual Vodavi Starplus Spd 4896 Hybrid Key Telephone System Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 543
    							STARPLUS @ SPD 4696
    Digital Key Telephone SystemPRINTING SYSTEM DATABASE PARAMETERS
    System 
    DataBase Printouts (Cont’d)
    K.Printing Hunt Group Parameters
    Programming Steps
    If a printout of Hunt Group Parameters is desired:
    1. Press the HUNT GROUP PARAMETERS
    flexible button (Button 
    #ll). The following
    message will be shown on the display phone:
    2. To print data for Hunt Group Parameters,
    press the HOLD button. The following display
    will be shown on the display phone:
    When the system has finished sending the re-
    quested information to the printer, confirmation tone
    will be heard.Description
    With a printer connected to the RS-232C port (future)on the-Central Processor Unit (CPU) or to either Port
    #3 or Port #4 on ttie I/O’ Expansion Module, the
    currently stored customer database can be printed
    or “uploaded” into a file. This command allows either
    a range of station data or all stations data informationto be “‘dumped” as a permanent record which can
    serve as a hard copy of the station attribute data-
    base.The system Baud rate must match that of the printer
    or receiving device.
    Refer to the following Figure for an example of the
    Hunt Group Parameter database printout.
    Default: None
    Related Programming: Refer to Sec. 610.8, Baud
    Rate Assignments, for setting the baud rate of the
    RS-232C port on the Central Processor Unit (CPU),
    Port 
    #3 or Port $4 on the I/O Expansion Module.
    issue 1, March 1994
    675-29 
    						
    							PRINTING SYSTEM DATABASE PARAMETERSSTARPLUS ’ SPD 4996
    Digital Key Telephone System
    iXTNT GXOUPS
    HGO..450
    :iG1..451
    !iG2..452
    XG3..453
    :%a..454
    ZG5..455
    iiG6..456
    EiG7..457
    =TLOT XJNT--
    TLOT IFIUNT--
    3TTOT XJNT_ --1
    ?ILOT :3UNT
    xLOT 3mT_-
    ?ILOT :mNTPILOT 
    :XJNT
    =TLOT --XUNTFigure 675-13 DB Printout of Hunt Group Parameters
    675-30Issue 1, March 1994 
    						
    							STARPLUS @ SPD 4896
    Digital Key Telephone SystemPRINTING SYSTEM DATABASE PARAMETERS
    System 
    DataBase Printouts (Cont’d)
    L.Printing ACD or UCD Group Parameters
    Programming Steps
    If a printout of ACD* or UCD Groups is desired:
    1. Press the ACD* or UCD GROUPS flexible
    button (Button 
    #12). The following message
    will be shown on the display phone:
    PRINT ACD GROUP
    PRESS HOLD
    2. To print data for the 
    ACD* or UCD Group
    Parameters, press the HOLD button. The fol-
    lowing display will be shown on the display
    phone:
    PRINTING ACD GROUP
    When the system has finished sending the re-
    quested information to the printer, confirmation tone
    will be heard.Description
    This feature is available with optional software.
    With a printer connected tothe RS-232C port (future)
    on the Central Processor Unit (CPU) or to either Port
    #3 or Port #4 on the I/O Expansion Module, the
    currently stored customer database can be printed
    or “uploaded” into a file. This command allows either
    a range of station data or all stations data informationto be “dumped” as a permanent record which can
    serve as a hard copy of the station attribute data-
    base.The system Baud rate must match that of the printer
    or receiving device.
    Referto the following Figure for an example of ACD*
    or UCD Group Parameter database printout.
    Default: None
    Related Programming: Refer to Sec. 610.8, Baud
    Rate Assignments, for setting the baud rate of the
    RS-232C port on the Central Processor Unit (CPU),
    Port 
    #3 or Port #4 on the I/O Expansion Module.
    *Features available with optional software.
    issue 
    1, March 1994675-31 
    						
    							PRINTING SYSTEM DATABASE PARAMETERSSTARPLUS @ SPD 4696
    Digital Key Telephone System
    ACD ALT OVR AN0 SUP STN#
    550
    ACD TIMERS
    RING MIT OVER 
    WRAP NAT NAR FRT606060
    403005
    551ANNOUNCEMENT TABLE556
    558
    TABLE TYPZINDEXTIME
    1#######.
    28888$##I
    3##+I++###48######
    5##if####
    6#######
    7######a
    8#######
    ACD SMDR REPORTING
    CO ICM EV? I/OBAUDN N N 
    12400
    Figure 675-14 
    06 Printout oi ACD Group Parameters
    67532
    lssu~ 1, March 1994 
    						
    							STARPLUS @ SPD 4896
    Digital Key Telephone SystemPRINTING SYSTEM DATABASE PARAMETERS
    System 
    DataBase Printouts (Cont’d)
    M.Printing Voice Mail Group ParametersProgramming Steps
    If a printout of Voice Mail Group Parameters is
    desired:
    1.Press the VM* GROUP PARAMETERS flex-
    ible button (Button 
    #13). The following mes-
    sage will be shown on the display phone:
    PRESS HOLD
    2.To print data for Voice Mail* Group Parame-
    ters, press the HOLD button. The following
    display will be shown on the display phone:
    PRINTING VM GROUPWhen the system has finished sending the re-
    quested information to the printer, confirmation tone
    will be heard.Description
    This feature is available with optional software.
    With a printer connected to the RS-232C port (future)on the Central Processor Unit (CPU) or to either Port
    #3 or Port #4 on the I/O Expansion Module, the
    currently stored customer database can be printed
    or “uploaded” into a file. This command allows either
    a range of station data or all stations data informationto be “dumped” as a permanent record which can
    serve as a hard copy of the station attribute data-
    base.The system Baud rate must match that of the printer
    or receiving device.
    When printing the VM Group Parameters, the follow-
    ing data is printed;l Voice Mail* Group Parameters
    l Voice Mail* Outpulsing Table (including the
    disconnect table)
    l Voice Mail* Options
    Refer to the following Figure for an example of the
    VM Group Parameter database printout.
    Default: None
    Related Programming: Refer to Sec. 610.8, BaudRate Assignments, for setting the baud rate of the
    RS-232C port on the Central Processor Unit (CPU),
    Port 
    #3 or Port #4 on the l/O Expansion Module.
    *Features available with optional software.
    Issue 1, March 1994675-33 
    						
    							PRINTING SYSTEM DATABASE PARAMETERSSTARPLlJ;- SPD 4696
    Digital Key Telephone System
    cVM 
    ALT LZV RET STN#
    440### #
    441####
    442# #if #443 
    ### ::444
    it## #
    445
    ### #446
    a## a
    447+ izVITT+I1
    Figure 675-15 
    DB Printout of Voice Mail Group Parameters
    675-34Issue 
    1, March 1994 
    						
    							STARPLUS @ SPD 4896Digital Key Telephone SystemPRINTING SYSTEM DATABASE PARAMETERS
    System 
    DataBase Printouts (Co&d)N. Abort Printing
    Programming Steps
    If you need to abort a printout:
    1.Press the ABORT PRINTING flexible button
    (Button 
    #20).2. Press the HOLD button. The message cur-
    rently on the display phone wiil remain un-
    changed, however the printing will be
    aborted.Description
    Issue 
    1, March 1994675-35 
    						
    							STARPLUS @ SPD 4896
    Digital Key Telephone SystemSYSTEM CHECK-OUT
    SECTION 700
    SYSTEM CHECK-OUT
    700.1INTRODUCTION700.3POWER UP SEQUENCE
    Prior to actual power up and initialization, the 
    Star-The power up sequence involves the proper appli-
    pius Digital Key Telephone System should be
    cation of AC power to the System, and CPB LEDs.checked over to avoid start up delays or improperA successful power up is assured if the installation
    loading. A step-by-step checklist is provided for thischecklist has been followed.
    purpose.1.700.2PRELIMINARY PROCEDURES
    m
    1.
    2.
    3.
    4.
    5.L.Make sure that the Basic Key Service Unit
    (BKSU) is properly grounded.
    Verify that all 
    PCB’s are firmly plugged into
    the correct card slot positions or expander
    modules are firmly seated onto their connec-
    tors.Inspect the MDF for shorted wiring and im-
    proper polarity that would affect the Digital
    Terminal or DSS console.
    Make certain that the nicad battery jumper on
    the Central Processor Unit (CPU) is set be-
    tween pins 2 
    8( 3 to enable Battery Backup
    option.
    Make sure that plug-ended MDF cables con-
    nected to the KSU are secure and are pluggedinto the correct position.
    3.
    4.
    F.4.Plug the AC power cord of the Key Service
    Unit into the dedicated 
    117V ac outlet.
    Turn the power switch of the KSU to ON.
    The Central Processor Unit (CPU) has two
    red 
    LEDs located on the front of the card. If
    the power up is successful, both red LEDs willflash.
    Press the reset button on the CPU. The aboveLED indications will repeat. Initialization may
    be required prior to programming.
    The system is ready for programming. If any
    problems have occurred, Refer to Section
    800, Maintenance and Troubleshooting.
    Table 700-l Power Supply Tests
    I
    VOLTAGE
    VOLTAGEI
    I
    IDESIGNATIONSTEST POINT i
    READINGLOCATION
    REMARKSI
    1
    /
    717 VAC+117 VAC 510%Commercial Power /
    ,
    SourceI
    						
    							STARPLUS @ SPD 4696
    Digital Key Telephone SystemMAINTENANCE AND TROUBLESHOOTING
    SECTION 800
    MAINTENANCE AND TROUBLESHOOTING
    800.1PRINTED CIRCUIT BOARD (PCB)
    TROUBLESHOOTING CHARTS
    Table 800-l Central Processor Unit (CPU)
    I
    FUNCTION
    :Iminn.
    1. Central Processor board
    (CPU) to control system
    operation.
    2. Read Only Memory
    (ROM) with factory set I
    I
    instructions.I
    1  3. Random Access Mem- j
    I
    ory (RAM) protected by a/
    nicad battery.I
    I  4. Halt switch for manual ~
    system restart.I
    5. Provides RS-232C port /
    for SMDR and 
    Termi- I
    nal/Remote Program-,CONTROLOPTIONSIIIFAULT OPTIONS
    /1 .Completesystem
    failure.
    2.Erroneous callprocessing.
    I  
    3.lnoperative features in
    /system operation.
    /  
    4.Partial failures in
    /j  system operation.
    i  
    5Continual system
    ;  restarts.
    I/  6,Failure of SMDR.
    //  
    7.10s~ of unique cust-I1omer data base
    1
    /j  programming.
    Table 800-2 CPU Static RAM Memory Size
    SIZE OF CHIPS
    (in Bits)
    1 Megabit chipj
    (2048 bytes)
    4 Megabit chipsi
    (4096 bytes) :RAM MEMORY SIZE(in bytes)2 
    - 1 Meg chips= 256K bytes
    4 
    - 1 Meg chips= 512K bytes
    2 
    - 4 Meg chips= 1024 bytes
    4 
    - 4 Meg chips= 2048K bytes
    Issue 1, March 1994800-l 
    						
    							MAINTENANCE AND TROUBLESHOOTING
    STARPLUS @ SPD 4896
    Digital Key Telephone System
    Table 8003 CPU EPROM Memory SizeSIZE OF CHIPSSW1 SWITCH POSITIONS
    EPROM MEMORY SIZE
    (in Megabits)
    1 (SA)2 (SB)3 (SC) 4 (not used)(in bytes)
    1 Megabit chips
    OFFOFF
    OFFOFF
    2 - 1 Meg chips = 256K bytes
    (1024 bytes)
    (open) (open) (open)(open)4 
    - Meg chips = 512K bytes
    2 Megabit chips
    j  ONOFF
    (2048 bytes)OFF /  OFF j
    !  (closed) (open)1  2 
    - 2 Meg chips = 512K bytes
    (open)I(open)!  4 
    - 2 Meg chips = 1024K bv-tes4 Megabit chips
    ONONOFFOFF2 - 4 Meg chips = 1024K bytes
    (4096 bytes)
    (closed) (closed) (open)(open)4 
    - 4 Meg chips = 2048K bytes
    8 Megabit chips
    1  
    (cizstd) (ctzstd) (cifstd) (fp:)2 
    - 8 Meg chips = 2048K bytes
    (8192 bytes)4 
    - 8 Meg chips 2 4096K bytes
    OFF= OPEN, ON= CLOSED
    Table 8004 Single Line Board (SL12)
    FUNCTION!
    CONTROLI
    OPTIONSI
    /IFAULT OPTIONS
    Provides interface for 12 /Two 
    LEDs that indicate INone11 .SLT can’t receive dial
    Singie Line Telephones.1  the presence of 
    +5V dc i
    tone.
    Also provides for 
    SLTs /  and -5V dc
    /’  2.Poor transmission
    with 
    M/W liahts.!
    , chamcttariditirsTable 
    800-5 Key Telephone Board (KTl2)
    FUNCTIONI
    CONTROL /OPTIONS
    ‘rovides interface for 12 jTwo LEDs that indicate /  None
    Digital
    Terminals, /  the presence of 
    +5V dc’
    DSS/DLS Consoles or !  and -5V dc
    SLA (OPX) modules.jFAULT OPTIONS
    1 .Unable to receiveintercom dial tone.
    2.Poor transmission
    characteristics,
    3.Key telephone set
    inoperative.
    4.Key telephone w-ableto invoke feat-
    ures
    5.No LED indications.1
    800-2
    Issue 1, March 1994 
    						