Home
>
Vodavi
>
Communications System
>
Vodavi Starplus Spd 4896 Hybrid Key Telephone System Installation Manual
Vodavi Starplus Spd 4896 Hybrid Key Telephone System Installation Manual
Have a look at the manual Vodavi Starplus Spd 4896 Hybrid Key Telephone System Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
STARPLUS @ SPD 4696 Digital Key Telephone SystemPRINTING SYSTEM DATABASE PARAMETERS System DataBase Printouts (Cont’d) K.Printing Hunt Group Parameters Programming Steps If a printout of Hunt Group Parameters is desired: 1. Press the HUNT GROUP PARAMETERS flexible button (Button #ll). The following message will be shown on the display phone: 2. To print data for Hunt Group Parameters, press the HOLD button. The following display will be shown on the display phone: When the system has finished sending the re- quested information to the printer, confirmation tone will be heard.Description With a printer connected to the RS-232C port (future)on the-Central Processor Unit (CPU) or to either Port #3 or Port #4 on ttie I/O’ Expansion Module, the currently stored customer database can be printed or “uploaded” into a file. This command allows either a range of station data or all stations data informationto be “‘dumped” as a permanent record which can serve as a hard copy of the station attribute data- base.The system Baud rate must match that of the printer or receiving device. Refer to the following Figure for an example of the Hunt Group Parameter database printout. Default: None Related Programming: Refer to Sec. 610.8, Baud Rate Assignments, for setting the baud rate of the RS-232C port on the Central Processor Unit (CPU), Port #3 or Port $4 on the I/O Expansion Module. issue 1, March 1994 675-29
PRINTING SYSTEM DATABASE PARAMETERSSTARPLUS ’ SPD 4996 Digital Key Telephone System iXTNT GXOUPS HGO..450 :iG1..451 !iG2..452 XG3..453 :%a..454 ZG5..455 iiG6..456 EiG7..457 =TLOT XJNT-- TLOT IFIUNT-- 3TTOT XJNT_ --1 ?ILOT :3UNT xLOT 3mT_- ?ILOT :mNTPILOT :XJNT =TLOT --XUNTFigure 675-13 DB Printout of Hunt Group Parameters 675-30Issue 1, March 1994
STARPLUS @ SPD 4896 Digital Key Telephone SystemPRINTING SYSTEM DATABASE PARAMETERS System DataBase Printouts (Cont’d) L.Printing ACD or UCD Group Parameters Programming Steps If a printout of ACD* or UCD Groups is desired: 1. Press the ACD* or UCD GROUPS flexible button (Button #12). The following message will be shown on the display phone: PRINT ACD GROUP PRESS HOLD 2. To print data for the ACD* or UCD Group Parameters, press the HOLD button. The fol- lowing display will be shown on the display phone: PRINTING ACD GROUP When the system has finished sending the re- quested information to the printer, confirmation tone will be heard.Description This feature is available with optional software. With a printer connected tothe RS-232C port (future) on the Central Processor Unit (CPU) or to either Port #3 or Port #4 on the I/O Expansion Module, the currently stored customer database can be printed or “uploaded” into a file. This command allows either a range of station data or all stations data informationto be “dumped” as a permanent record which can serve as a hard copy of the station attribute data- base.The system Baud rate must match that of the printer or receiving device. Referto the following Figure for an example of ACD* or UCD Group Parameter database printout. Default: None Related Programming: Refer to Sec. 610.8, Baud Rate Assignments, for setting the baud rate of the RS-232C port on the Central Processor Unit (CPU), Port #3 or Port #4 on the I/O Expansion Module. *Features available with optional software. issue 1, March 1994675-31
PRINTING SYSTEM DATABASE PARAMETERSSTARPLUS @ SPD 4696 Digital Key Telephone System ACD ALT OVR AN0 SUP STN# 550 ACD TIMERS RING MIT OVER WRAP NAT NAR FRT606060 403005 551ANNOUNCEMENT TABLE556 558 TABLE TYPZINDEXTIME 1#######. 28888$##I 3##+I++###48###### 5##if#### 6####### 7######a 8####### ACD SMDR REPORTING CO ICM EV? I/OBAUDN N N 12400 Figure 675-14 06 Printout oi ACD Group Parameters 67532 lssu~ 1, March 1994
STARPLUS @ SPD 4896 Digital Key Telephone SystemPRINTING SYSTEM DATABASE PARAMETERS System DataBase Printouts (Cont’d) M.Printing Voice Mail Group ParametersProgramming Steps If a printout of Voice Mail Group Parameters is desired: 1.Press the VM* GROUP PARAMETERS flex- ible button (Button #13). The following mes- sage will be shown on the display phone: PRESS HOLD 2.To print data for Voice Mail* Group Parame- ters, press the HOLD button. The following display will be shown on the display phone: PRINTING VM GROUPWhen the system has finished sending the re- quested information to the printer, confirmation tone will be heard.Description This feature is available with optional software. With a printer connected to the RS-232C port (future)on the Central Processor Unit (CPU) or to either Port #3 or Port #4 on the I/O Expansion Module, the currently stored customer database can be printed or “uploaded” into a file. This command allows either a range of station data or all stations data informationto be “dumped” as a permanent record which can serve as a hard copy of the station attribute data- base.The system Baud rate must match that of the printer or receiving device. When printing the VM Group Parameters, the follow- ing data is printed;l Voice Mail* Group Parameters l Voice Mail* Outpulsing Table (including the disconnect table) l Voice Mail* Options Refer to the following Figure for an example of the VM Group Parameter database printout. Default: None Related Programming: Refer to Sec. 610.8, BaudRate Assignments, for setting the baud rate of the RS-232C port on the Central Processor Unit (CPU), Port #3 or Port #4 on the l/O Expansion Module. *Features available with optional software. Issue 1, March 1994675-33
PRINTING SYSTEM DATABASE PARAMETERSSTARPLlJ;- SPD 4696 Digital Key Telephone System cVM ALT LZV RET STN# 440### # 441#### 442# #if #443 ### ::444 it## # 445 ### #446 a## a 447+ izVITT+I1 Figure 675-15 DB Printout of Voice Mail Group Parameters 675-34Issue 1, March 1994
STARPLUS @ SPD 4896Digital Key Telephone SystemPRINTING SYSTEM DATABASE PARAMETERS System DataBase Printouts (Co&d)N. Abort Printing Programming Steps If you need to abort a printout: 1.Press the ABORT PRINTING flexible button (Button #20).2. Press the HOLD button. The message cur- rently on the display phone wiil remain un- changed, however the printing will be aborted.Description Issue 1, March 1994675-35
STARPLUS @ SPD 4896 Digital Key Telephone SystemSYSTEM CHECK-OUT SECTION 700 SYSTEM CHECK-OUT 700.1INTRODUCTION700.3POWER UP SEQUENCE Prior to actual power up and initialization, the Star-The power up sequence involves the proper appli- pius Digital Key Telephone System should be cation of AC power to the System, and CPB LEDs.checked over to avoid start up delays or improperA successful power up is assured if the installation loading. A step-by-step checklist is provided for thischecklist has been followed. purpose.1.700.2PRELIMINARY PROCEDURES m 1. 2. 3. 4. 5.L.Make sure that the Basic Key Service Unit (BKSU) is properly grounded. Verify that all PCB’s are firmly plugged into the correct card slot positions or expander modules are firmly seated onto their connec- tors.Inspect the MDF for shorted wiring and im- proper polarity that would affect the Digital Terminal or DSS console. Make certain that the nicad battery jumper on the Central Processor Unit (CPU) is set be- tween pins 2 8( 3 to enable Battery Backup option. Make sure that plug-ended MDF cables con- nected to the KSU are secure and are pluggedinto the correct position. 3. 4. F.4.Plug the AC power cord of the Key Service Unit into the dedicated 117V ac outlet. Turn the power switch of the KSU to ON. The Central Processor Unit (CPU) has two red LEDs located on the front of the card. If the power up is successful, both red LEDs willflash. Press the reset button on the CPU. The aboveLED indications will repeat. Initialization may be required prior to programming. The system is ready for programming. If any problems have occurred, Refer to Section 800, Maintenance and Troubleshooting. Table 700-l Power Supply Tests I VOLTAGE VOLTAGEI I IDESIGNATIONSTEST POINT i READINGLOCATION REMARKSI 1 / 717 VAC+117 VAC 510%Commercial Power / , SourceI
STARPLUS @ SPD 4696 Digital Key Telephone SystemMAINTENANCE AND TROUBLESHOOTING SECTION 800 MAINTENANCE AND TROUBLESHOOTING 800.1PRINTED CIRCUIT BOARD (PCB) TROUBLESHOOTING CHARTS Table 800-l Central Processor Unit (CPU) I FUNCTION :Iminn. 1. Central Processor board (CPU) to control system operation. 2. Read Only Memory (ROM) with factory set I I instructions.I 1 3. Random Access Mem- j I ory (RAM) protected by a/ nicad battery.I I 4. Halt switch for manual ~ system restart.I 5. Provides RS-232C port / for SMDR and Termi- I nal/Remote Program-,CONTROLOPTIONSIIIFAULT OPTIONS /1 .Completesystem failure. 2.Erroneous callprocessing. I 3.lnoperative features in /system operation. / 4.Partial failures in /j system operation. i 5Continual system ; restarts. I/ 6,Failure of SMDR. // 7.10s~ of unique cust-I1omer data base 1 /j programming. Table 800-2 CPU Static RAM Memory Size SIZE OF CHIPS (in Bits) 1 Megabit chipj (2048 bytes) 4 Megabit chipsi (4096 bytes) :RAM MEMORY SIZE(in bytes)2 - 1 Meg chips= 256K bytes 4 - 1 Meg chips= 512K bytes 2 - 4 Meg chips= 1024 bytes 4 - 4 Meg chips= 2048K bytes Issue 1, March 1994800-l
MAINTENANCE AND TROUBLESHOOTING STARPLUS @ SPD 4896 Digital Key Telephone System Table 8003 CPU EPROM Memory SizeSIZE OF CHIPSSW1 SWITCH POSITIONS EPROM MEMORY SIZE (in Megabits) 1 (SA)2 (SB)3 (SC) 4 (not used)(in bytes) 1 Megabit chips OFFOFF OFFOFF 2 - 1 Meg chips = 256K bytes (1024 bytes) (open) (open) (open)(open)4 - Meg chips = 512K bytes 2 Megabit chips j ONOFF (2048 bytes)OFF / OFF j ! (closed) (open)1 2 - 2 Meg chips = 512K bytes (open)I(open)! 4 - 2 Meg chips = 1024K bv-tes4 Megabit chips ONONOFFOFF2 - 4 Meg chips = 1024K bytes (4096 bytes) (closed) (closed) (open)(open)4 - 4 Meg chips = 2048K bytes 8 Megabit chips 1 (cizstd) (ctzstd) (cifstd) (fp:)2 - 8 Meg chips = 2048K bytes (8192 bytes)4 - 8 Meg chips 2 4096K bytes OFF= OPEN, ON= CLOSED Table 8004 Single Line Board (SL12) FUNCTION! CONTROLI OPTIONSI /IFAULT OPTIONS Provides interface for 12 /Two LEDs that indicate INone11 .SLT can’t receive dial Singie Line Telephones.1 the presence of +5V dc i tone. Also provides for SLTs / and -5V dc /’ 2.Poor transmission with M/W liahts.! , chamcttariditirsTable 800-5 Key Telephone Board (KTl2) FUNCTIONI CONTROL /OPTIONS ‘rovides interface for 12 jTwo LEDs that indicate / None Digital Terminals, / the presence of +5V dc’ DSS/DLS Consoles or ! and -5V dc SLA (OPX) modules.jFAULT OPTIONS 1 .Unable to receiveintercom dial tone. 2.Poor transmission characteristics, 3.Key telephone set inoperative. 4.Key telephone w-ableto invoke feat- ures 5.No LED indications.1 800-2 Issue 1, March 1994